首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

2.
Capillary electrophoresis (CE) is a new, high-resolution tool for the analysis of DNA restriction fragments and DNA amplified by the polymerase chain reaction (PCR). By combining many of the principles of traditional slab gel methods in a capillary format, it is possible to perform molecular size determinations of human and plant PCR amplification products and DNA restriction fragments. DNA restriction fragments and PCR products were analyzed by dynamic sieving electrophoresis (DSE) and capillary gel electrophoresis (CGE). As part of this study, sample preparation procedures, injection modes, and the use of molecular mass markers were evaluated. Optimum separations were performed using the uPage-3 (3% T, 3% C) CGE columns with UV detection at 260 nm. Membrane dialysis and ultrafiltration/centrifugation proved to be nearly equivalent methods of sample preparation. Reproducibility studies demonstrated that blunt-ended, non-phosphorylated markers (specifically allele generated markers) provide the most accurate calibration for PCR product analysis. This study demonstrates that CE offers a high-speed, high-resolution analytical method for accurately determining molecular size and/or allelic type as compared with traditional methodologies.  相似文献   

3.
Large-scale genotyping, mapping and expression profiling require affordable, fully automated high-throughput devices enabling rapid, high-performance analysis using minute quantities of reagents. In this paper, we describe a new combination of microwell polymerase chain reaction (PCR) based DNA amplification technique with automated ultrathin-layer gel electrophoresis analysis of the resulting products. This technique decreases the reagent consumption (total reaction volume 0.75-1 microL), the time requirement of the PCR (15-20 min) and subsequent ultrathin-layer gel electrophoresis based fragment analysis (5 min) by automating the current manual procedure and reducing the human intervention using sample loading robots and computerized real time data analysis. Small aliquots (0.2 microL) of the submicroliter size PCR reaction were transferred onto loading membranes and analyzed by ultrathin-layer gel electrophoresis which is a novel, high-performance and automated microseparation technique. This system employs integrated scanning laser-induced fluorescence-avalanche photodiode detection and combines the advantages of conventional slab and capillary gel electrophoresis. Visualization of the DNA fragments was accomplished by "in migratio" complexation with ethidium bromide during the electrophoresis process also enabling real time imaging and data analysis.  相似文献   

4.
A high-performance capillary electrophoresis system with a polysiloxane-coated capillary and polymeric buffer additives was investigated for the analysis of DNA restriction fragments and polymerase chain reaction (PCR) products. Mobility data and Ferguson plots of the DNA fragments at different polymer (hydroxypropylmethylcellulose) concentrations indicated that effective molecular sieving was obtained consistent with existing data of conventional gel electrophoresis and with recent HPCE data. The precision and peak efficiency were excellent and the system was applied to the analysis of specific co-amplified DNA sequences (HIV-1 and HLA-DQ-alpha). After PCR, ultrafiltration was used in the sample preparation step to desalt the sample and to remove superfluous PCR reaction products. Electrokinetic injection was used for sample introduction into the capillary. The addition of ethidium bromide to the buffer resulted in longer migration times of DNA fragments and better peak resolution. During HPCE, an artifact associated with dilute DNA solutions leading to the appearance of extra peaks in the electropherogram was found.  相似文献   

5.
The significant demands for single nucleotide polymorphism detection and genotyping assays have grown. Most common assays are based on the recognition of the target sequence by the hybridization with its specific probe having the complementary sequence of the target. Herein, a simple, label‐free, and economical non‐hybridization assay was developed for single nucleotide polymorphism detection and genotyping, based on the direct discrimination of single base mutation by simple capillary electrophoresis separation for single‐stranded DNA in an acidic electrophoretic buffer solution containing urea. Capillary electrophoresis separation of single‐base sequential isomers of DNA was achieved due to charge differences resulting from the different protonation properties of the DNA bases. Single nucleotide polymorphism detection and genotyping were achieved by discriminating the electropherogram pattern change, that is, peak number in the electropherogram, obtained by the proposed method. The successful practical application of the proposed method was demonstrated through single nucleotide polymorphism detection and genotyping on a known gene region of 84‐mer, in which guanine to adenine single‐base mutation is commonly observed, using a human hair sample in combination with genomic DNA extraction, polymerase chain reaction amplification, DNA purification from polymerase chain reaction products, and capillary electrophoresis separation.  相似文献   

6.
DNA analysis plays a great role in genetic and medical research, and clinical diagnosis of inherited diseases and particular cancers. Development of new methods for high throughput DNA analysis is necessitated with incoming of post human genome era. A new powerful analytical technology, called microchip capillary electrophoresis (MCE), can be integrated with some experimental units and is characterized by high-speed, small sample and reagent requirements and high-throughput. This new technology, which has been applied successfully to the separation of DNA fragments, analysis of polymerase chain reaction (PCR) products, DNA sequencing, and mutation detection, for example, will become an attractive alternative to conventional methods such as slab gel electrophoresis, Southern blotting and Northern blotting for DNA analysis. This review is focused on some basic issues about DNA analysis by MCE, such as fabrication methods for microchips, detection system and separation schemes, and several key applications are summarized.  相似文献   

7.
We are demonstrating a cost-effective multichannel capillary electrophoresis system for a high-efficiency double-stranded DNA (dsDNA) fragments analysis. This bench-type high-performance DNA analysis (HDA) system uses fluorescence-type detection with inexpensive solid-state light sources and nonmoving integrated emission collection micro-optics. DNA samples are analyzed simultaneously by using a multiple usage and disposable multicapillary cartridge, which contains integrated capillary channels, optical fibers and an integrated sieving gel reservoir. Using commercially available dsDNA size markers as indicators, the HDA system provides high resolving power in 7 min separations. The system can hold a total of 192 samples in two 96-well polymerase chain reaction (PCR) plates, which can be automatically analyzed within 2.5 h. This affordable system can be used in laboratories to replace slab gel electrophoresis for routine and high-throughput dsDNA analysis.  相似文献   

8.
Gradient elution isotachophoresis (GEITP) was demonstrated for DNA purification, concentration, and quantification from crude samples, represented here by soiled buccal swabs, with minimal sample preparation prior to human identification using STR analysis. During GEITP, an electric field applied across leading and trailing electrolyte solutions resulted in isotachophoretic focusing of DNA at the interface between these solutions, while a pressure‐driven counterflow controlled the movement of the interface from the sample reservoir into a microfluidic capillary. This counterflow also prevented particulates from fouling or clogging the capillary and reduced or eliminated contamination of the delivered DNA by PCR inhibitors. On‐line DNA quantification using laser‐induced fluorescence compared favorably with quantitative PCR measurements and potentially eliminates the need for quantitative PCR prior to STR analysis. GEITP promises to address the need for a rapid and robust method to deliver DNA from crude samples to aid the forensic community in human identification.  相似文献   

9.
Alterations in global DNA methylation are implicated in several pathobiological processes. The tissues stored as paraffin blocks represent an important source of DNA for retrospective genetic and epigenetic analysis on a large scale. Therefore, we developed the first capillary electrophoresis method able to measure global methylation in formalin-fixed, paraffin-embedded (FFPE) DNA extracts. A field-amplified sample injection capillary electrophoresis method with UV detection for the separation and quantification of cytosine and 5-methylcytosine released following DNA hydrolysis by means of formic acid was employed. Analytes were baseline-separated within 8 min by using 300 mM tris(hydroxymethyl)aminomethane phosphate pH 3.75 as the running buffer. With use of electrokinetic injection the limit of detection (LOD) in real sample was 0.1 nM, thus improving by about 400-fold the LOD of the previously described methods based on capillary electrophoresis. Sample extraction and purification were optimized so that evaluation of the DNA methylation degree was possible starting from 0.5-1 μg of DNA with intra- and interassay relative standard deviations for the 5-methylcytosine to total cytosine ratio of 2.0 and 3.2%, respectively. Because of its high accuracy and throughput, our method will be useful for large-scale applications to determine the implications of genomic DNA methylation levels in tumorigenesis.  相似文献   

10.
An integrated protocol for solid-phase DNA sequencing using a robotic work station is described involving magnetic separation of DNA and analysis of the sequencing product by electrophoresis with automated detection of the fluorescently labeled fragments. The method, which is based on magnetic beads in combination with streptavidin-biotin technology, can be used for sequencing both genomic and plasmid DNA. The DNA template is obtained by the polymerase chain reaction (PCR). Protocols to prepare five and ten immobilized samples is described, giving 10 and 20 single-stranded templates, respectively. The magnetic purification steps are performed in a microtiter plate and this allows for an integrated scheme involving a subsequent procedure for automated primer annealing and sequencing reactions. Here, the procedure is examplified by direct genomic sequencing of DNA in blood sample from a human immunodeficiency virus (HIV)-infected patient and a cloned human antibody DNA fragment using fluorescently labeled sequencing primers.  相似文献   

11.
We report an accurate and reproducible DNA quantitation method using the polymerase chain reaction (PCR). The amount of PCR product is monitored after each PCR cycle by capillary electrophoresis. To ensure accurate quantitation, a non-amplified internal standard is added to each PCR-amplified electrophoresis sample to correct for variations in injection volume. Quantitation of the sample is based on the number of cycles necessary to generate a predetermined amount of PCR product. Duck hepatitis B virus genome was used as a model in this study. The genome was quantified with a linear relationship between cycle number and logarithm of sample DNA for amounts of sample DNA between 30 and 3.1 x 10(8) copies ( r(2)>0.999). The relative standard deviation for the corrected capillary electrophoresis signal was 2.7%, while the relative standard deviation for the overall assay was 3.0%. Results from a single-blind study generated a relative error of 1.3%.  相似文献   

12.
无胶筛分毛细管电泳分析几百个碱基对核酸的条件优化   总被引:1,自引:0,他引:1  
丁晓萍  廖杰  刘晓达  王全立  马立人 《色谱》1998,16(6):485-488
通过正交设计实验综合分析了内充羟丙基甲基纤维素(HPMC)无胶筛分毛细管电泳中的分离场强、HPMC浓度、柱长度和柱内径对核酸分离的影响。结果表明,柱长度越长、柱内径越小、分离场强越小,分离效果越好。考虑实际情况,为能在短时间内使几百个碱基对的核酸得到有效分离,一般选择37cm×75μmi.d.的涂壁毛细管、柱内质量浓度为8g/L的HPMC、场强为324V/cm的条件,并在此种条件下分析了ApoB100基因的低浓度聚合酶链式反应(PCR)扩增产物(710bp)。  相似文献   

13.
An integrated system for DNA sequencing based on a nanoreactor for cycle-sequencing reaction coupled with on-line capillary zone electrophoresis (CZE) for purification and capillary gel electrophoresis (CGE) for separation is presented. Less than 100 nl of premixed reagent solution, which includes dye-labeled terminator pre-mix, bovine serum albumin and template, was hydrodynamically injected into a fused-silica capillary (75 microm I.D.) inside a laboratory-made microthermocycler for cycle sequencing reaction. In the same capillary, the reaction products were purified by CZE followed by on-line injection of the DNA fragments into another capillary for CGE. Over 540 base pairs (bp) of DNA can be separated and the bases called for single-standed DNA with 0.9% error rate. The total time was about 3.5 h, or a cycle time of 2 h with staggered operation. For double-stranded DNA, a longer reaction time was required and base calling up to 490 bp with 1.2% error rate was achieved. The whole system is readily adaptable to automated multiplex operation for DNA sequencing or polymerase chain reaction analysis.  相似文献   

14.
聚合酶链反应(PCR)样品中的Cl^-、引物等小分子对单链构象多态性一毛细管电泳分析有重要影响。本文用毛细管电泳一间接紫外法测定了PCR样品中的Cl^-浓度,并对乙醇沉淀法和试剂盒纯化法用于PCR样品的纯化效果进行比较,在此基础上研究了Cl^-浓度、引物及其二聚体在SSCP-CE分析中的影响。结果表明,它们主要影响DNA进样量而对分离效率影响不大。  相似文献   

15.
A miniaturized, integrated and automated system based on capillary fluidics has been developed for nanoliter DNA analysis directly from cheek cells. All steps for DNA analysis, including injecting aqueous reagents and DNA samples, mixing the solutions together, thermal cell lysis, polymerase chain reaction (PCR), transfer and injection of PCR product, separation, sizing and detection of those products are performed in a capillary-based integrated system. A small amount of cheek cells collected by a plastic toothpick is directly dissolved in the PCR cocktail in a plastic vial or mixed on-line with a small volume of PCR cocktail (125 nl) in the capillary. After thermal cell lysis and PCR in a microthermal cycler, the DNA fragments are mixed with DNA size standards and transferred to a micro-cross for injection and separation by capillary gel electrophoresis. Programmable syringe pumps, switching valves, multiposition and freeze-thaw valves are used for microfluidic control in the entire system. This work establishes the feasibility of performing all the steps of DNA analysis from real samples in a capillary-based nanoliter integrated system.  相似文献   

16.
An automatic DNA fragment collector using capillary array gel electrophoresis has been developed. A sheath flow technique is used for not only detection but also collection of DNA fragments. In a sheath flow cell, the DNA fragments separated by 16 capillaries flow independently into corresponding sampling capillaries. The fraction collector consists of 16 sampling trays and each sampling tray is set beneath each end of the sampling capillaries to collect the flow-through DNA fragments. Certain DNA fragments are automatically sorted by controlling the movement of the sampling trays according to the signals from the system. The collector experimentally separated two mixtures of polymerase chain reaction (PCR) products: one prepared by using eight different sizes (base lengths from 161 to 562) of DNAs; and the other prepared by a differential display (DD) method with cDNA fragments. Collected DNA fragments are amplified by PCR and measured by electrophoresis. DNA fragments with base length differences of one (base lengths 363 and 364) were successfully separated. A separated DNA fragment from the DD sample was also successfully sequenced. In addition, differentially expressed DNA fragments were automatically sorted by comparative analysis, in which two similar cDNA fragment groups, labeled by two different fluorophores, respectively, were analyzed in the same gel-filled capillary. These results show that the automatic DNA fragment collector is useful for gene hunting in research fields such as drug discovery and DNA diagnostics.  相似文献   

17.
采用三重PCR反应, 同时扩增CaMV 35S启动子、 hsp70 intron1和CryIA(b)基因之间序列以及Invertase基因, 扩增产物用无胶筛分毛细管电泳-激光诱导荧光检测, 从而建立了多重PCR-毛细管电泳-激光诱导荧光快速检测转基因玉米的新方法. 对影响多重PCR扩增和毛细管电泳的因素进行了优化. 在优化的条件下, 本方法可以同时检测转基因玉米样品中3种外源基因. 经序列测试证实, 三重PCR 扩增产物的序列与原基因完全一致, 表明扩增结果可靠. 该方法能检出0.05% MON810转基因玉米成分, 远低于欧盟对转基因食品规定标识的质量分数阈值(1%). 该方法对玉米及其制品的检测结果与实时荧光PCR方法的检测结果一致, 与传统的琼脂糖凝胶电泳法相比, 具有特异性高\, 快速及灵敏等优点, 适用于玉米中转基因成分以及转基因玉米MON810品系的快速筛选、 鉴定和检测, 能满足我国实施转基因食品标签法规的要求.  相似文献   

18.
PCR is an indispensable technique used in DNA analysis. However, with the traditional methods, the time spent on amplification and the subsequent analysis of PCR products is generally long. Therefore, it is essential to improve these two steps so that the whole procedure can be made faster. In the present work, with lambda-DNA as the control template, the amplification of 300-bp fragment could be completed within 37 s with capillary reaction chambers of LightCycler, and the following analysis of PCR products could be completed within 120 s with microchip electrophoresis as the detector. Since the high detection sensitivity of microchip electrophoresis, PCR products with template concentration as low as 5 fg/microL could be detected only after 435 s of amplification. In addition, based on additional optimized conditions simulated by CoventorWare, PCR microchips with distinct structure of the reaction chambers have been designed and successfully applied to the amplification of 300-bp fragment. By comparison, those chambers with ellipse and racket shapes were found to offer very high amplification efficiency. All of these results demonstrate the promise of integrating PCR and electrophoresis on microchip for developing easy-carrying instruments for the fast in situ detection of DNA.  相似文献   

19.
This paper reports the development of a disposable, integrated biochip for DNA sample preparation and PCR. The hybrid biochip (25 × 45 mm) is composed of a disposable PDMS layer with a microchannel chamber and reusable glass substrate integrated with a microheater and thermal microsensor. Lysis, purification, and PCR can be performed sequentially on this microfluidic device. Cell lysis is achieved by heat and purification is performed by mechanical filtration. Passive check valves are integrated to enable sample preparation and PCR in a fixed sequence. Reactor temperature is needed to lysis and PCR reaction is controlled within ±1°C by PID controller of LabVIEW software. Buccal epithelial cell lysis, DNA purification, and SY158 gene PCR amplification were successfully performed on this novel chip. Our experiments confirm that the entire process, except the off‐chip gel electrophoresis, requires only approximately 1 h for completion. This disposable microfluidic chip for sample preparation and PCR can be easily united with other technologies to realize a fully integrated DNA chip.  相似文献   

20.
Huang X  Hou L  Xu X  Chen H  Ji H  Zhu S 《The Analyst》2011,136(20):4254-4259
Traditional real-time polymerase chain reaction (PCR) requires a purified DNA sample for PCR amplification and detection. This requires PCR tests be conducted in clean laboratories, and limits its applications for field tests. This work developed a method that can carry out DNA purification, amplification and detection in a single PCR tube. The polypropylene PCR tube was first treated with chromic acid and peptide nucleic acids (PNA) as DNA-capturer were immobilized on the internal surface of the tube. Cauliflower mosaic virus 35S (CaMV-35S) promoter in the crude extract was hybridized with the PNA on the tube surface, and the inhibitors, interfering agents and irrelevant DNA in the crude extract were effectively removed by rinsing with buffer solutions. The tube that has captured the target DNA can be used for the following real-time PCR (RT-PCR). By using this approach, the detection of less than 2500 copies of 35S plasmids in a complex sample could be completed within 3 hours. Chocolate samples were tested for real sample analysis, and 35S plasmids in genetically modified chocolate samples have been successfully identified with this method in situ. The novel One-PCR-tube method is competitive for commercial kits with the same time and simpler operation procedure. This method may be widely used for identifying food that contains modified DNA and specific pathogens in the field.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号