首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
熊国华  刘虹 《分析化学》1994,22(11):1141-1144
本研究了Mn^2+和Co^2+对7-(8-羟基-3,6-二磺基萘偶氮)-8-羟基喹啉-5-磺酸-硼砂反应体系的混合荧光增敏作用。实验条件下,荧光增敏强度满足线性加和关系的范围是:Mn^2+浓度0 ̄2.9×10^-7mol/L;Co^2+浓度0 ̄8.8~10^-7mol/L;总浓度不超过1.0×10^-6mol/L。检出限量为Mn^2+4.5×10^-9mol/L和Co^2+1.4×10^-8mo  相似文献   

2.
本报导了以玻碳电极为基体的1∶12硅钼杂多阴离子薄膜化学修,铈电极的制备及其电化学特性。并应用于导数伏安法测定。在4.0×10^-3mol/L9NH4)6Mo7O24-66.8×10^-2mol/LNa3Cit-0.48mol/L NHO3体系中,硅浓度在8.3×10^-7~1.7×10^-3mol/L。对可溶性硅(以SiO2计)为245.05mg/L的黑液,稀释10倍后,取2.00mL平行测定  相似文献   

3.
宋俊峰  高雅芳 《分析化学》1995,23(4):438-441
本报道一种测定哌仑西平的单扫描示波极谱法,在0.1mol/LNH4Cl-NH3.H2O(pH8.0±0.1)缓冲液中,哌仑西平有一极谱还原波,其峰电位为-1.51V(vs.SCE),其一阶导数峰高与哌仑西闰浓度在6.6×10^-7-4.6×10^-6mol/L(r=0.9981)和6.6×10^-6-1.6×10^-5mol/L(r=0.9991)范围内有线性关系,检测限为3.4×10-7mol  相似文献   

4.
无外加过氧化氢时氯化血红素催化性能的研究   总被引:1,自引:0,他引:1  
研究了在十二烷基苯磺酸钠胶束介质中,氯化血红素对溶解氧氧化水杨基荧光酮的催化性能,发现该体系满足Michaelis-Menten方程,在pH8.6的条件下,测得Km和Vmax值分别为7.94×10^-5mol/L和0.113s^-1。利用反应平衡法分光光度法可测定6.0×10^-8 ̄7.2×10^-7mol/L的Hemin。  相似文献   

5.
乳酸环丙沙星单扫描示波极谱法研究   总被引:3,自引:0,他引:3  
研究了乳酸环丙沙星的极谱伏安行为,在pH=8.3的0.02mol/L,NH4Cl-NH3.H2O底液中,乳酸环丙沙星能产生1个灵敏的还原峰,峰电位为-1.61V,其导数峰高与浓度在3.9×10^-8~1.8×10^-6mol/L和1.8×10^6~1.1×10^-5mol/L范围内呈现良好的线性关系,相关系数r=0.9997,检测下限为2.5×10^-8mol/L,用于乳酸环丙沙星注射液的测定,相  相似文献   

6.
王桂芬  朴元哲 《分析化学》1998,26(12):1490-1493
应用循环伏安法、微分脉冲伏安法对多菌灵在破碳电极上的电化学行为及其测定进行了研究。在pH=9.0的2mol/L NH3-NH4Cl底液中,对其进行循环伏安扫描,发现于0.61V(vs.Ag/AgCl)产生一灵敏的氧化峰。微分脉冲伏安法殉菌灵的检测限为4×10^-8mol/L。多菌灵的浓度在5.0×10^-7 ̄1.0×10^-5mol/L间与微分脉冲伏安峰电流呈线性关系(r=0.9942)。对于1×  相似文献   

7.
氨基萘磺酸盐无保护流体室温磷光的取代基位置效应   总被引:1,自引:0,他引:1  
牟兰  陈小康 《分析化学》1999,27(5):509-512
以TINO3作重原子微扰剂,Na2SO3作化学除氧剂,在无需加入任何保护介质条件下,仅需仪器光源适当照射,1-氨基4-萘磺酸盐、1-氨基5-萘磺酸盐、2-氨基1-萘磺酸盐水溶液均能产生强而稳定的室温磷光信号(RTP)。3种氨基萘磺酸盐浓度分别在4.0×10^-8 ̄1.2×10^-5mol/L;1.2×10^-6 ̄1.6×10^-5mol/L;1.6×10^-7 ̄8.0×10^-6和8.0×10^-  相似文献   

8.
于泳  毛燕宁  李启隆 《分析化学》1999,27(5):562-565
抗癌药物紫杉醇在0.2mol/L NH3-NH3-NH4Cl中,采用单扫示波极说法进行测定,形成一良好的还原峰,峰电位Ep=-1.45V(vs.SCE)。峰电流与紫杉醇的浓度在1.0×10^-7 ̄8.0×10^-6mol/l之间呈线性关系;检测限为5.0×10^-8mol/L,并将此方法应用于样品测定。用线性扫描和循环伏安法研究体系的性质,结果表明,紫杉醇的电极过程属于具有吸附性的准可逆过程。  相似文献   

9.
本文报导了以玻碳电极为基体的1:12硅钼杂多阴离子薄膜化学修铈电极的制备及其电化学特性。并应用于导数伏安法测定。在4.0×10 ̄(-3)m0l/L(NH_4)_6MO_7O_(24)-6.8×10 ̄(-2)mol/LNa_3Cit-0.48mol/LNHO_3体系中,硅浓度在8.3×10 ̄(-7)~1.7×10 ̄(-3)mol/L范围内与峰电流呈良好线性关系,检测限为8.0×10 ̄(-7)mol/L。对可溶性硅(以SiO_2计)为245.05mg/L的黑液,稀释10倍后,取2.00mL平行测定9次,RSD为0.58%,加标回收率在97.3%~104.4%间。  相似文献   

10.
铜(Ⅱ)和锌(Ⅱ)分别在0.1mol/LKH2PO4-Na2HPO4缓冲溶液(pH6.5)和0.25mol/LNH4Cl溶液中,与氟哌酸形成良好的络合吸附波,峰电位分别为-0.26V和-1.28V(vs.SCE),络合比分别为1:3和1:2,峰电流与铜(Ⅱ)和锌(Ⅱ)的浓度均在4.0×10^-7~5.0×10^-6nol/L范围内呈线性关系,检测限分别为7.0×10^-8和5.0×10^-8mol  相似文献   

11.
A highly sensitive fluorescence quenching method has been developed for selective determination of hydrogen peroxide based on the catalytic effect of hemin on theo-hydroxyphenylfluorone (a new fluorogenic substrate) and hydrogen peroxide system. Under optimum conditions, the calibration graph was linear over the range 0–1.0 × 10−6mol/liter hydrogen peroxide, with a limit of detection of 8.0 × 10−9mol/liter in a 10-min reaction period. It can easily be incorporated into the determination of biochemical substances that produce hydrogen peroxide under catalytic oxidation by their oxidase. This possibility has been tested for the determination of glucose in human sera as an example.  相似文献   

12.
A new method has been developed for the determination of myoglobin (Mb) based on its enzymatic activity for the oxidation of o-phenylenediamine (OPDA) with hydrogen peroxide. Stopped-flow spectrophotometry was used to study the kinetic behavior of the oxidation reaction. The catalytic activity of Mb was compared to other three kinds of catalyst. The time dependent absorbance of the reaction product, 2,3-diamimophenazine (DAPN), at a wavelength of 426 nm was recorded. The initial reaction rate obtained at 40 degrees C was found to be proportional to the concentration of Mb in the range of 1.0 x 10(-6) to 4.0 x 10(-9)mol L(-1). The detection limit of Mb was found to be 9.93 x 10(-10)mol L(-1). The relative standard deviations were within 5% for the determination of different concentrations of Mb. Excess of bovine serum albumin (BSA), Ca(II), Mg(II), Cu(II), glucose, caffeine, lactose and uric acid did not interfere.  相似文献   

13.
The preparation and utilization of a novel composite silica-hemin nanoparticles (CSHNs) as mimetic peroxidase are reported in this article. Experimental results showed that the composite nanoparticles had unique advantages over free hemin molecules in good stability and highly catalytic activity. By employing these nanoparticles as biocatalyst, we developed a new spectrofluorometric method for the determination of trace level glucose. The calibration graph for glucose was linear over the range 4.0 x 10(-7) mol/L - 7.0 x 10(-5) mol/L, with a detection limit of 1.0 x 10(-7) mol/L. The proposed method has been successfully applied to the determination of glucose in serum samples and offers the advantages of being rapid, stable, sensitive, and renewable.  相似文献   

14.
In an ammonium buffer medium at pH 8.9–9.5, hemin exhibits mimetic peroxidase activity, and has a catalytic effect on the oxidative decoloration of bromopyrogallol red (BPR) with hydrogen peroxide. On this basis and in presence of ethanol as an effect-enhancing agent, a spectrophotometric determination of hydrogen peroxide is described with an apparent molar absorptivity of 4.00×104?l?mol?1?cm?1 and a linear range from 3.2×10?7 to 3.2×10?5?mol?l?1. BPR has advantages over some of widely used chromogenic substrates in aspects of sensitivity, simplicity and detection wavelength, while hemin has better stability than peroxidase. The system can be easily coupled with a glucose oxidase-catalyzed reaction, and glucose in the concentration range of 6.0×10?7? 3.2×10?5?mol?l?1 is spectrophotometrically determined. The method has been applied to the analyses of synthetic water and human serum samples. The Michaelis parameters and the mechanism of the mimetic peroxidase reaction are also investigated.  相似文献   

15.
A multilayered glucose biosensor via sequential deposition of Prussian blue (PB) nanoclusters and enzyme-immobilized poly(toluidine blue) films was constructed on a bare Au electrode using electrochemical methods. The whole configuration of the present biosensor can be considered as an integration of several independent hydrogen peroxide sensing elements. In each sensing element, the poly(toluidine blue) film functioned as both the supporting matrix for the glucose oxidase immobilization and the inhibitor for the diffusion of interferences, such as ascorbic acid and uric acid. Meanwhile, the deposited Prussian blue nanocluster layers acts as a catalyst for the electrochemical reduction of hydrogen peroxide formed from enzymatic reaction. Performance of the whole multilayer configuration can be tailored by artificially arranging the sensing elements assembled on the electrode. Under optimal conditions, the biosensors exhibit a linear relationship in the range of 1 x 10(-4) to 1 x 10(-2) mol/L with the detection limit down to 10(-5) mol/L. A rapid response for glucose could be achieved in less than 3 s. For 1 mM glucose, 0.5 mM acetaminophen, 0.2 mM uric acid, and 0.1 mM ascorbic acid have no obvious interferences (<5%) for glucose detection at an optimized detection potential. The present multilayered glucose biosensor with a high selectivity and sensitivity is promising for practical applications.  相似文献   

16.
Hemoglobin can exhibit not only a direct electron transfer reacting after being entrapped in a DNA membrane, but also a greatly enhanced peroxidase activity toward the reduction of hydrogen peroxide. Based on the direct electrochemical property and nice enzymatic activity of the protein in a DNA membrane, a reagentless hydrogen peroxide biosensor was prepared. The peak current related to hydrogen peroxide was linearly proportional to its concentration in the range of 1.9 x 10(-6)-6.8 x 10(-4) mol L(-1). The detection limit was 1 x 10(-6) mol/L.  相似文献   

17.
A biosensor based on stearic acid-graphite powder modified with sweet potato (Ipomoea batatas (L.) Lam.) tissue as peroxidase source was constructed and applied in organic solvents. Several parameters were studied to evaluate the performance of this biosensor such as stearic acid-graphite powder and tissue composition, type and concentration of supporting electrolyte, organic solvents, water/organic solvent ratio (% v/v) and hydrogen peroxide concentration. After selection of the best conditions, the biosensor was applied for the determination of hydroquinone in cosmetic creams in methanol. At the peroxidase electrode hydroquinone is oxidized in the presence of hydrogen peroxide and the radical formed was reduced back electrochemically at -180 mV vs Ag/AgCl (3.0 mol L(-1) KCl). The reduction current obtained was proportional to the concentration of hydroquinone from 6.2 x 10(-5) to 1.5 x 10(-3) mol L(-1) (r = 0.9990) with a detection limit of 8.5 x 10(-6) mol L(-1). The recovery of hydroquinone from two samples ranged from 98.8 to 104.1% and an RSD lower than 1.0% for a solution containing 7.3 x 10(-4) mol L(-1) hydroquinone and 1.0 x 10(-3) mol L(-1) hydrogen peroxide in 0.10 mol L(-1) tetrabutylammonium bromide methanol-phosphate buffer solution (95:5% v/v) (n = 10) was obtained.  相似文献   

18.
高效液相色谱-荧光检测法测定环境样品中的过氧化物   总被引:9,自引:0,他引:9  
徐金荣  陈忠明 《色谱》2005,23(4):366-369
对高效液相色谱-荧光检测法测定过氧化氢和有机过氧化物的方法进行了改进,从而提高了方法的检测灵敏度。以氯化血红素(hemin)作催化剂进行柱后衍生反应,过氧化物将对羟基苯乙酸氧化生成能吸收荧光的二聚物,然后用荧光检测器检测。实验确定了最佳反应管温度和荧光检测波长。应用该法测定了大气和雨水样品中过氧化物的浓度。  相似文献   

19.
Zhou Y  Nagaoka T  Li F  Zhu G 《Talanta》1999,48(2):461-467
A novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO(4). Hydrogen peroxide can be directly determined by luminol-KIO(4)-H(2)O(2) CL system. The detection limit was 3.0x10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0x10(-7)-6.0x10(-4) mol l(-1). The relative standard deviation of H(2)O(2) was 1.1% for 2.0x10(-6) mol l(-1) (N=11). Glucose was indirectly determined through measuring the H(2)O(2) generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H(2)O(2), which, in turn, coupled with the luminol-KIO(4)-H(2)O(2) CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mug ml(-1). The relative standard deviation was 2.1% for 10 mug ml(-1) (N=11). Detection limit of glucose was 0.08 mug ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO(4)-H(2)O(2) CL system. The calibration curve was linear over the range of 1.0x10(-7)-1.0x10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0x10(-7) mol l(-1) (N=11). Detection limit of ascorbic acid was 6.0x10(-8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection.  相似文献   

20.
C Fan  H Wang  D Zhu  G Wagner  G Li 《Analytical sciences》2001,17(2):273-276
Horseradish peroxidase was incorporated in a kieselguhr membrane. The electron-transfer process of the enzyme was examined by cyclic voltammetry. It was observed that the electron-transfer reactivity of horseradish peroxidase was greatly enhanced, and that direct electrochemistry was accordingly feasible. Using the merits of the direct electron-transfer reactivity of horseradish peroxidase and its specific enzymatic catalysis towards hydrogen peroxide, an unmediated hydrogen peroxide biosensor was constructed. The calibration plot of this hydrogen peroxide sensor was linear in the range of 2.0 x 10(-6) mol/L - 6.5 x 10(-4) mol/L. The relative standard deviation was 4.1% for 6 successive determinations at a concentration of 1.0 x 10(-4) mol/L. The detection limit was 1.0 x 10(-6) mol/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号