首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

2.
A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 mm x 4.6 mm, 10 microm) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 microm) analytical column in order to perform online sample preparation. Direct injection of 100 microL of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.  相似文献   

3.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

4.
To study the safety and potential health benefits of soy isoflavones, a rapid and simple method based on liquid chromatography combined with mass spectrometry (LC/MS) and photodiode array detector (PDA) was developed for the determination of isoflavones in rat plasma. The analytes included daidzein, genistein, glycitein, equol, 4-ethyl phenol, and biochanin A over a concentration range of 1.0-4320.0 nM using 75 microL of rat plasma. Rat plasma samples were hydrolyzed by adding an enzyme mixture from Helix pomatia containing glucuronidase and sulfatase to convert the isoflavone beta-glycosides daidzin, genistin, and glycitin to their active aglycone forms. A liquid-liquid extraction method using ethyl acetate as the extraction solvent was used to extract aglycones and the internal standards (phenolphthalein beta-D glucuronide, 4-methylumbelliferyl sulfate, and apigenin) from digested plasma samples. The extract was evaporated to dryness under a nitrogen stream, reconstituted with 0.1% formic acid in water-acetonitrile (85 + 15), and injected into a Zorbax SB-CN reversed-phase column (4.6 x 75 mm, 3.5 microm particle size). The Micromass ZQ detector was operated in the positive ion selected-ion monitoring mode. The flow rate for LC was 1.0 mL/min, with a split where 25% of the effluent was introduced into the electrospray ionization probe of the MS instrument and 75% into the PDA. The chromatographic run time was 16.0 min, with delay of 10 min/injection. The interday precision and accuracy of the standard samples were <2.6% relative standard deviation and <10% relative error, respectively. Recovery of the reported isoflavones with this method varied from 86 to 100%.  相似文献   

5.
A rapid, accurate, and selective method was developed for the forensic determination of ionophore antibiotics in animal feeds. A simple extraction procedure and liquid chromatography/tandem mass spectrometry (LC/MS/MS) in the selected reaction monitoring (SRM) mode were used for rapid identification and confirmation of monensin and lasalocid in feed samples and for quantitation of monensin. Extracts from a homogenous portion of ground feeds were prepared using liquid-solid extraction and liquid-liquid extraction techniques. Feed extracts were further purified by a simple defatting and solvent wash step and then concentrated to dryness. Feed extract residues were reconstituted in 1 mL LC mobile phase and a 2 microL aliquot injected into the SRM LC/MS system. The latter system used a C18, 100 x 2.0 mm, LC column coupled to a PE-Sciex API 2000 tandem triple quadrupole mass spectrometer equipped with a TurbolonSpray LC/MS interface. Feed samples were extracted and analyzed for the determination of monensin and lasalocid within a couple of hours. Control feed samples fortified with monensin at concentrations from 50 ppb to 5 ppm provided a linear response and calibration curve across this range with a correlation coefficient of 0.996.  相似文献   

6.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for determining tanshinone IIA in rat tissues. After a single step liquid-liquid extraction with diethyl ether, tanshinone IIA and loratadine (internal standard) was subjected to LC/MS/MS analysis using positive electro-spray ionization under selected reaction monitoring mode. Chromatographic separation of tanshinone IIA and loratadine was achieved on a Hypersil BDS C(18) column (i.d. 2.1 x 50 mm, 5 microm) with a mobile phase consisting of methanol-1% formic acid (90:10, v/v) at a flow rate of 300 microL/min. The intra-day and inter-day precision of the method were less than 10.2 and 12.4%, respectively. The intra-day and inter-day accuracies ranged from 99.7 to 109.7%. The lowest limit of quantification for tanshinone IIA was 1 ng/mL. The method was applied to a tanshinone IIA tissue distribution study after an oral dose of 60 mg/kg to rats. Tanshinone IIA tissue concentrations decreased in the order of stomach > small intestine > lung > liver > fat > muscle > kidneys > spleen > heart > plasma > brain > testes. Tanshinone IIA still could be detected in most of the tissues at 20 h post-dosing. These results indicate that the LC/MS/MS method was rapid and sensitive to quantify tanshinone IIA in different rat tissues.  相似文献   

7.
A simple, specific and sensitive LC-MS/MS assay for simultaneous determination of simvastatin (SV) and its active beta-hydroxy acid metabolite, simvastatin acid (SVA) in human plasma was developed using a statin analog as internal standard (IS). The method was validated over a dynamic linear range of 0.20-100.00 ng/mL for SV and 0.10-50.00 ng/mL for SVA with correlation coefficient r > or = 0.9987 and 0.9989, respectively. The analytes and IS were extracted from 500 microL aliquots of human plasma via liquid-liquid extraction using methyl tert-butyl ether and separated through an Aquasil C18 column (100 mm x 2.1 mm, 5 microm). Detection of analytes and IS was done by MS/MS with a turbo ion spray interface operating in positive ion and selective reaction monitoring acquisition mode. The total chromatographic run time was 3.0 min. Flash freezing of the aqueous phase was an added advantage during liquid-liquid extraction, which considerably reduced time and labour. The method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect. The method was successfully used for bioequivalence study of 40 mg SV tablet formulation in 12 human subjects under fasting condition.  相似文献   

8.
Kaletra is an important antiretroviral drug, which has been developed by Abbott Laboratories. It is composed of lopinavir (low-pin-a-veer) and ritonavir (ri-toe-na-veer). Both have been proved to be human immunodeficiency virus (HIV) protease inhibitors and have substantially reduced the morbidity and mortality associated with HIV-1 infection. We have developed and validated an assay, using liquid chromatography coupled with atmospheric pressure chemical ionization tandem mass spectrometry (LC/MS/MS), for the routine quantification of lopinavir and ritonavir in human plasma, in which lopinavir and ritonavir can be simultaneously analyzed with high throughput. The sample preparation consisted of liquid-liquid extraction with a mixture of hexane: ethyl acetate (1:1, v/v), using 100 microL of plasma. Chromatographic separation was performed on a Waters Symmetry C(18) column (150 mm x 3.9 mm, particle size 5 microm) with reverse-phase isocratic using mobile phase of 70:30 (v/v) acetonitrile: 2 mM ammonium acetate aqueous solution containing 0.01% formic acid (v/v) at a flow rate of 1.0 mL/min. A Waters symmetry C(18) guard column (20 mm x 3.9 mm, particle size 5 microm) was connected prior to the analytical column, and a guard column back wash was performed to reduce the analytical column contamination using a mixture of tetrahydrofuran (THF), methanol and water (45:45:10, v/v/v). The analytical run was 4 min. The use of a 96-well plate autosampler allowed a batch size up to 73 study samples. A triple-quadrupole mass spectrometer was operated in a positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over the concentration ranges of 19-5,300 ng/mL for lopinavir and 11-3,100 ng/mL for ritonavir. A-86093 was used as an internal standard (I.S.). The relative standard deviation (RSD) were <6% for both lopinavir and ritonavir. Mean accuracies were between the designed limits (+/-15%). The robust and rapid LC/MS/MS assay has been successfully applied for routine assay to support bioavailability, bioequivalence, and pharmacokinetics studies.  相似文献   

9.
A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.  相似文献   

10.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for the quantitative determination of cynandione A in rat plasma and tissues. The plasma samples were pretreated by liquid-liquid extraction with ethyl acetate after the internal standard (honokiol) had been spiked. The tissue samples were homogenized with physiological saline and treated further like the plasma samples. The separation was performed using a Zorbax SB-C(18) column (3.5 microm, 2.1 x 100 mm) and a C18 guard column (5 microm, 4.0 x 2.0 mm) with an isocratic mobile phase consisting of methanol-0.1% formic acid (78:22, v/v) at a flow rate of 0.2 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple-reaction monitoring mode using the electrospray ionization technique in negative mode. The nominal retention times for cynandione A and honokiol were 1.41 and 2.63 min, respectively. The method was validated within the concentration range 0.2-1000 ng/mL in plasma and homogenized tissue for cynandione A, and the calibration curves were linear with correlation coefficients >0.992. The lower limit of quantification of cynandione A was 0.2 ng/mL. The intra-day and inter-day precision and accuracy of the assay in plasma were less than 14.4%, while the intra-day and inter-day precision and accuracy of the assay in tissue homogenate were less than 14.2%. This method proved to be suitable for study of pharmacokinetics and tissue distribution of cynandione A in rat.  相似文献   

11.
We have developed a sensitive and specific liquid chromatography/mass spectrometry (LC/MS) method for the simultaneous determination of cyclosporine A (CsA) and its three main metabolites (AM1, AM4N and AM9) in human blood. Following protein precipitation, supernatant was directly injected into the LC/MS system. Chromatographic separation was accomplished on a Symmetry C8 (4.6 x 75 mm, 3.5 microm) column with a linear gradient elution prior to detection by atmospheric pressure chemical ionization (APCI) MS using selected ion monitoring (SIM) in positive mode. This method can be applied to single mass equipment. The analytical range for each analyte was set at 1-2500 ng/mL using 100 microL of blood sample. The analytical method was fully validated according to FDA guidance. Intra-day mean accuracy and precision were 95.2-113.5% and 0.9-8.9%, respectively. Inter-day mean accuracy and precision were 95.8-107.0% and 1.5-10.7%, respectively. In blood all analytes were stable during three freeze/thaw cycles, for 24 h at room temperature and for 12 months at or below -15 degrees C. Stability was also confirmed in processed samples for 24 h at 10 degrees C and for 6 months at 4 degrees C in methanol. In addition, we confirmed the method could avoid matrix effects from transplant subjects' samples. This LC/MS technique provided an excellent method for simultaneous quantitative determination of CsA and its three metabolites for evaluation of their pharmacokinetic profiles.  相似文献   

12.
A reliable and sensitive method incorporating high turbulence liquid chromatography (HTLC) online extraction with tandem mass spectrometry (MS/MS), for simultaneous determination of suberoylanilide hydroxamic acid (SAHA) and its two metabolites, SAHA-glucuronide (M1) and 4-anilino-4-oxobutanoic acid (M2), in human serum, has been developed to support clinical studies. The HTLC technology significantly reduces the time required for sample clean-up since sample extraction and analysis are performed online. Clinical samples, internal standards (IS) and buffer are transferred into 96-well plates using a robotic liquid handling system. A 20 microL aliquot of prepared sample is directly injected into the HTLC/LC-MS/MS system where the matrix is rapidly washed away to waste and the analytes are retained on the narrow-bore extraction column (0.5 x 50 mm), using an aqueous mobile phase at 1.5 mL/min. Analytes are then eluted from the extraction column and transferred to the analytical column using a gradient mobile phase prior to detection by MS/MS. Interference with determination of SAHA from in-source dissociation of M1 is eliminated by the chromatographic separation. The resolution of SAHA and M1 did not change for more than 1500 serum sample injections by applying an acid wash (15% acetic acid) on the extraction column. The linear calibration ranges for SAHA, M1, and M2 are 2-500, 5-2000, and 10-2000 ng/mL, respectively. Assay intraday validation was conducted using five calibration curves prepared in five lots of human control serum. The precision expressed as relative standard deviation (RSD) is less than 6.8% and accuracy is 94.6-102.9% of nominal values for all three analytes. Assay specificity, freeze/thaw stability, storage stability, and matrix effects were also assessed.  相似文献   

13.
A rapid and sensitive method for the quantitation of buspirone in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed. Plasma samples were treated by liquid-liquid extraction with methyl tert-butyl ether (MTBE). The chromatographic separation was performed isocratically on a reversed-phase Shiseido C18 column (50 mm x 2.0 mm, 3 microm) with a mobile phase of acetonitrile/0.1% acetic acid (1:1, v/v). The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 386 --> 122 for buspirone and m/z 409 --> 238 for amlodipine (the internal standard). The method was validated to determine its specificity, recovery, limit of quantitation, accuracy and precision. The lower limit of quantitation was 0.02 ng/mL with a relative standard deviation of less than 10%. The present method provides an accurate, precise and sensitive tool for buspirone and was successfully applied to a pharmacokinetic study in eight subjects.  相似文献   

14.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method for the determination of the P-glycoprotein and breast cancer resistance protein inhibitor Elacridar in human and dog plasma is described. The internal standard was stable isotopically labelled Elacridar. Sample pretreatment involved liquid-liquid extraction with tert-butyl methyl ether. Analysis of Elacridar and internal standard was performed by reversed-phase LC on a basic stable minibore analytical column with an eluent consisting of acetonitrile and aqueous ammonia. An API-2000 triple-quadrupole mass spectrometer with an electrospray ion source was used in the positive-ion multiple reaction monitoring mode. The run time per sample was only 6 min. The method is sensitive and specific, with a dynamic range from 1 to 500 ng ml(-1) from 100 microl of human or dog plasma. The accuracy of the method was within 15% bias and the precision was lower than 15% for all tested concentration levels and in both matrices. The method is simple and the liquid-liquid extraction produces clean samples. This method was successfully applied to support the pharmacokinetics of a clinical trial in which orally applied Elacridar was used as a bioavailability enhancer.  相似文献   

15.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published).  相似文献   

16.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-ginsenoside Rg3 in dog. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. Dioscin was used as the internal standard. The method had a lower limit of quantitation of 0.5 ng/mL for Rg3 in 200 microL of plasma or 2 ng/mL in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of Rg3 in plasma. The intra- and inter-day precisions were measured to be below 8% and accuracy between -1.5 and 1.4% for all quality control samples. This quantitation method was successfully applied to pharmacokinetic studies of Rg3 after both an oral and an intravenous administration to beagle dogs. No Rh2 and protopanaxadiol were detected in plasma.  相似文献   

17.
An LC-ESI-MS method was developed and validated for the assay of apomorphine in canine plasma using one-step liquid-liquid extraction. The analytes were separated on a Phenomenex Gemini C18 (150 mm x 2.0 mm id 3 microm) column and determined by MS in the positive ion mode. The linear range was 0.4-40 ng/mL with an LOD of 0.2 ng/mL for apomorphine in plasma. The intraday and interday precision and accuracy of quality control samples were < 5.9% RSD and < 7.5% bias for apomorphine. Extraction recoveries were > 80%. The validated method was successfully applied to analyze canine plasma samples in a pharmacokinetic study of apomorphine in dogs and detailed pharmacokinetic parameters were calculated.  相似文献   

18.
This paper describes a sensitive and selective liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for determination of the novel survivin suppressant YM155, 1-(2-methoxyethyl)-2-methyl-4,9-dioxo-3-(pyrazin-2-ylmethyl)-4,9-dihydro-1H-naphtho[2,3-d]imidazolium, which is developed for the treatment of solid tumors. This method uses a liquid-liquid extraction from 0.25 mL of dog plasma. LC separation was carried out on a Genesis Silica column (50 mm x 3.0 mm i.d.) at a flow-rate of 0.5 mL/min. Compounds were eluted using a mobile phase of 5 mm ammonium acetate and 0.1% formic acid in water-0.1% formic acid in acetonitrile, 17:83 (v/v). MS/MS detection was carried out with an MDS-Sciex API3000 triple quadrupole mass spectrometer in positive electrospray ionization mode. The standard curve was linear from 0.05 to 50 ng/mL (r > or = 0.9968). The lower limit of quantitation was 0.05 ng/mL. Good intra- and inter-day assay precision (within 7.4% RSD) and accuracy (within +/-12.3%) were obtained. The extraction recovery was 66.2%. The method was successfully applied to preclinical pharmacokinetic studies in dogs.  相似文献   

19.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

20.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method to determine levonorgestrel in human plasma was developed and fully validated. After hexane-ethyl acetate (70:30, v/v) induced extraction from the plasma samples, levonorgestrel was subjected to LC/MS/MS analysis using electro-spray ionization. The MS system was operated in the selected reaction monitoring mode. Chromatographic separation was performed on a Hypersil BDS C18 column (i.d. 2.1x50 mm, particle size 3 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 0.25-90 ng/mL for levonorgestrel. The lower limit of quantification of the method was 0.25 ng/mL for levonorgestrel. The intra- and inter-batch precision was 3.7-10.2 and 5.1-12.9%, respectively, for all quality control samples at concentrations of 0.5, 6.0 and 45.0 ng/mL. These results indicate that the method was efficient with a simple preparation procedure and a very short running time (2.0 min) for levonorgestrel compared with those methods reported in the literature and had high selectivity, acceptable accuracy, precision and sensitivity. The validated LC/MS/MS method was successfully used for a bioequivalence study of two tablet formulations of levonorgestrel in healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号