首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Following a review of gas chromatographic element-specific detection by microwave-induced plasma atomic emission spectrometry for the purposes of empirical-formula determination, current results for an atmospheric-pressure helium plasma are presented. Hydrocarbons and chlorinated organic compounds are used as models and compounds resulting from chlorination of fulvic acid are characterized. Accuracy and precision for carbon, hydrogen and chlorine determinations are reported. The former usually being better than ±5% and the latter in the range 1–3%. Manual and computer methods for empirical-formulae determination are presented and compared.  相似文献   

2.
The detection of methylmercury species (MeHg) in fish tissue was investigated. Samples were digested with KOH-methanol and acidified prior to extraction with methylene chloride. MeHg was back-extracted from the organic phase into water. An aliquot of this aqueous solution (buffered to pH 5) was subjected to derivatization with sodium tetraphenylborate (NaBPh4) and then extracted with toluene. The organic phase containing MePhHg was injected into a gas chromatograph (GC) which is on-line with a microwave-induced plasma atomic emission spectrometer (MIP-AED). The quantification limit was about 0.6 microg/g and 0.1 microg/g of MeHg (as Hg) for 0.08 g of freeze-dried fish powder and 0.5 g of fresh samples, respectively. Two certified reference materials, CRM 464 (tuna fish) from Community Bureau of Reference-BCR and DORM-2 (dogfish muscle) from National Research Council Canada-NRC were selected for checking the accuracy of the method. This methodology was applied to the determination of MeHg in some kinds of fish from the Carmo river with alluvial gold recovery activities ("garimpos") in Mariana, Minas Gerais, Brazil.  相似文献   

3.
The detection of methylmercury species (MeHg) in fish tissue was investigated. Samples were digested with KOH-methanol and acidified prior to extraction with methylene chloride. MeHg was back-extracted from the organic phase into water. An aliquot of this aqueous solution (buffered to pH 5) was subjected to derivatization with sodium tetraphenylborate (NaBPh4) and then extracted with toluene. The organic phase containing MePhHg was injected into a gas chromatograph (GC) which is on-line with a microwave-induced plasma atomic emission spectrometer (MIP-AED). The quantification limit was about 0.6 μg/g and 0.1 μg/g of MeHg (as Hg) for 0.08 g of freeze-dried fish powder and 0.5 g of fresh samples, respectively. Two certified reference materials, CRM 464 (tuna fish) from Community Bureau of Reference-BCR and DORM-2 (dogfish muscle) from National Research Council Canada-NRC were selected for checking the accuracy of the method. This methodology was applied to the determination of MeHg in some kinds of fish from ¶the Carmo river with alluvial gold recovery activities (“garimpos”) in Mariana, Minas Gerais, Brazil.  相似文献   

4.
In order to attain a lower detection limit with the HS GC MIP analytical method (Head-Space Gas Chromatography with Microwave-Induced Plasma detection) recently developed for the analysis of methylmercury in biological samples, the quarter-wave Evenson-type cavity used until now was replaced by a TM010 Beenakker-type cavity, which was used with both argon and helium as carrier gas. With an argon plasma, an eightfold increase in detection limit was gained compared with the argon plasma sustained by the Evenson cavity, while only a four-fold increase was gained with the helium plasma. In a second step of the study, the MIP detector was replaced by an AFS (atomic fluorescence) detector (CVAFS Model-2, Brooks Rand Ltd, Seattle, USA). With this AFS detector a detection limit of 1 ng methyl mercury per g biological tissue could be reached; i.e. measurements were 40 times more sensitive than those using the Evenson cavity. This detector has some other advantages compared with MIP detection: it is less expensive and easier to manipulate, while the same precision and accuracy are obtained. The use of AFS as detector in the headspace gas chromatographic system is therefore an important improvement for the analysis of methyl-mercury in biological samples.  相似文献   

5.
A simple, rapid, sensitive, and solvent-free method was developed for determination of plant-signalling compounds, the three C6-aldehydes hexanal, (Z)-3-hexenal, and (E)-2-hexenal, in tomato plant emission by gas chromatography-mass spectrometry (GC-MS) and solid-phase microextraction (SPME) with on-fiber derivatization. In this method, O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) in aqueous solution was first headspace adsorbed onto a 65 microm poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber at 25 degrees C for 5 min, and then the fiber with adsorbed PFBHA was used for headspace extraction of tomato plant emission at 25 degrees C for 6 min. Finally, the resulting oximes adsorbed on the fiber were desorbed and analyzed by GC-MS. Extraction conditions and method validation were studied. The proposed method had low detection limit values for the three aldehydes from 0.1 to 0.5 ng/L and good precision (RSD less than 10%). In this work, the method was applied to investigation of tomato plant defense response to Helicoverpa armigera.  相似文献   

6.
A sensitive procedure for the determination of three UV filters: ethylhexyl salicylate (EHS), 3,3,5-trimethylcyclohexyl salicylate (Homosalate, HMS), 2-hydroxy-4-methoxybenzophenone (BP-3) and two related hydroxylated benzophenones (2,4-dihydroxybenzophenone, BP-1 and 2,2′-dihydroxy-4-methoxybenzophenone, BP-8) in water samples is presented. Analytes were first concentrated on the coating of a solid-phase microextraction (SPME) fibre, on-fibre silylated and then determined using gas chromatography combined with tandem mass spectrometry (GC-MS/MS). Factors affecting the performance of extraction and derivatization steps are thoroughly evaluated and their effects on the yield of the sample preparation discussed. Under final working conditions, a PDMS-DVB coated SPME fibre was exposed directly to 10 mL of water, adjusted at pH 3, for 30 min. After that, the fibre was placed in the headspace (HS) of a 1.5 mL vial containing 20 μL of N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA). On-fibre silylation of hydroxyl groups contained in the structure of target compounds was performed at 45 °C for 10 min. The whole sample preparation process was completed in 40 min, providing limits of quantification from 0.5 to 10 ng L−1 and acceptable precision (RSDs under 13%) for samples spiked at different concentrations. All compounds could be accurately determined in river and treated wastewater (relative recoveries from 89 to 115%) using standards in ultrapure water, whereas standard addition is recommended to quantify their levels in untreated wastewater. Analysis of wastewater revealed the systematic presence of BP-3 and BP-1 in raw samples with maximum concentrations close to 500 and 250 ng L−1, respectively.  相似文献   

7.
A gas chromatography/negative chemical ionization mass spectrometry (GC/NCIMS) method using headspace solid-phase microextraction (HS-SPME) was developed for the determination of trichloroethylene (TCE) in blood, liver, kidney, lung and brain. The method was optimized with respect to several parameters including extraction time, extraction temperature, desorption time and salt addition. The method showed good linearity over the range of 0.025-25 ng/mL in blood and 0.075-75 ng/g in tissues with correlation coefficient (R2) values higher than 0.99. The precision and accuracy for intra-day and inter-day measurements were less than 10%. The relative recoveries of all matrices were greater than 52%. Samples showed no significant loss during 8 h in the autosampler and following three freeze/thaw cycles. Validation results demonstrated that selected-ion monitoring of the 35Cl and 37Cl isotopes using NCI resulted in reliable and sensitive quantitation. This validated method was successfully applied to study the toxicokinetics of TCE following oral administration of extremely low doses of this potential human carcinogen to small test animals (rats).  相似文献   

8.
Natalia Campillo 《Talanta》2007,71(3):1417-1423
A direct immersion solid-phase microextraction (SPME) procedure was used in combination with capillary gas chromatography with atomic emission detection (GC-AED) for the determination of 10 pesticides (organochlorines, organophosphorus compounds and pyrethrins) in herbal and tea infusions. Ionic strength, sample dilution and time and temperature of the absorption and desorption stages were some of the parameters investigated in order to select the optimum conditions for SPME with a 100 μm PDMS fiber-coating. Element-specific detection and quantification was carried out by monitoring the chlorine (479 nm) and bromine (478 nm) emission lines, which provided nearly specific chromatograms. Calibration was carried out by using a spiked sample infusion. The detection limits varied between 11.9 ng ml−1 for deltamethrin and 0.03 ng ml−1 for p,p′-DDE and p,p′-DDD. The recoveries ranged from 73.5% for deltamethrin to 108.3% for p,p′-DDT in a spiked white tea infusion. Two of the eight samples analyzed contained low levels of some the pesticides considered.  相似文献   

9.
The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD.  相似文献   

10.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

11.
A rapid and simple method of using solid-phase microextraction was developed for determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) in water samples. In this method, the target analyte is extracted from the sample into the polymeric coating of the fused-silica fiber. After exposure, the fiber is thermally desorbed in the heated injection port of the gas chromatograph, and a chromatographic analysis is performed by using low-resolution tandem mass spectrometry. Parameters that may affect the extension of the microextraction process, such as sampling mode, sample volume, temperature, agitation, and sampling time, were studied. Extraction efficiencies for 3 coating fibers were investigated: 100 microm poly(dimethylsiloxane) (PDMS), 65 microm PDMS-divinylbenzene, and 75 microm carboxen-PDMS. Linearity was evaluated (R = 0.999) for a 250-fold concentration range from the fg/mL to the pg/mL level. The 2,3,7,8-TCDD was detected at the fg/mL level when the headspace over the water sample was sampled for 60 min; the limit of detection obtained was better than that of Method 8280B of the U.S. Environmental Protection Agency. The proposed method performed well when applied to the analysis of tap water, lake water, and seawater samples.  相似文献   

12.
Ma J  Xiao R  Li J  Li J  Shi B  Liang Y  Lu W  Chen L 《Journal of separation science》2011,34(12):1477-1483
A simple, fast, sensitive and cost-effective method based on headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization coupled with gas chromatography-mass spectrometry was developed for the determination of six typical aldehydes, 2E-hexenal, heptanal, 2E-heptenal, 2E,4E-heptadienal, 2E-decenal and 2E,4E-decadienal in laboratory algae cultures. As derivatization reagent, O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride, was loaded onto the poly(dimethylsiloxane)/divinylbenzene fiber for aldehydes on-fiber derivatization prior to HS-SPME. Various influence factors of extraction efficiency were systematically investigated. Under optimized extraction conditions, excellent method performances for all the six aldehydes were attained, such as satisfactory extraction recoveries ranging from 67.1 to 117%, with the precision (relative standard deviation) within 5.3-11.1%, and low detection limits in the range of 0.026-0.044 μg/L. The validated method was successfully applied for the analysis of the aldehydes in two diatoms (Skeletonema costatum and Chaetoceros muelleri), two pyrrophytas (Prorocentrum micans and Scrippsiella trochoidea) and Calanus sinicus eggs (feeding on the two diatoms above).  相似文献   

13.
The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid–liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.  相似文献   

14.
A method for trace level determination of organomercury species in different biota matrixes by using aqueous-phase propylation followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography (GC) coupled to pyrolysis-atomic fluorescence spectrometry (Py-AFS) detection has been optimized. To maximize peak area and symmetry factors of methylmercury (MeHg) and ethylmercury (EtHg) analyzed as propyl derivatives, carrier and make-up flow rates were optimized by a user-defined experimental design. A multiple response simultaneous optimization was applied using the desirability function to achieve global optimal operating conditions. They were attained at 2 and 6 mL min−1 as carrier and make-up gas flow rates, respectively. In addition, pyrolyser temperature was also optimized, yielding the best value at 750 °C. Limits of detection and quantification at the optimum conditions were 0.04 ng g−1 and 0.13 ng g−1 for both, MeHg and EtHg. The developed analytical procedure was validated with a certified reference material (DORM-2) and applied to the determination of organomercury incurred in waterfowl egg and fish samples.  相似文献   

15.
Aldehydes are considered potential markers for enhanced oxidative stress and have been proposed as a diagnostic measure of cancer status. Do to their volatility and activity, it is very difficult to accurately measure aldehydes in human blood. In the present work, gas chromatography/mass spectrometry (GC/MS) and solid-phase microextraction (SPME) with on-fiber derivatization was developed for determination of aldehydes in human blood. O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) in aqueous solution was first adsorbed by a SPME fiber, and then the aldehydes in blood samples were headspace extracted by the SPME fiber and rapidly derivatized with PFBHA on the SPME fiber. Finally, the oximes formed were desorbed and detected by GC/MS in electron ionization (EI) mode. Validation of the present method was carried out, and the method was applied to quantitative analysis of the aldehydes in lung cancer blood. The results demonstrated that GC/MS and SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for the determination of aldehydes in human blood.  相似文献   

16.
An efficient and sensitive method for the determination of methylmercury in biological samples was developed based on acid leaching extraction of methylmercury into toluene. Methylmercury in the organic phase was determined by electrothermal atomic absorption spectrometry (ETAAS). The methylmercury signal was enhanced and the reproducibility increased by formation of certain complexes and addition of Pd-DDC modifier. The complex of methylmercury with DDC produced the optimum analytical signal in terms of sensitivity and reproducibility compared to complexes with dithizone, cysteine, 1,10-phenanthroline, and diethyldithiocarbamate. Method performance was optimized by modifying parameters such as temperature of mineralization, atomization, and gas flow rate. The limit of detection for methylmercury determination was 0.015 μg g−1 and the RSD of the whole procedure was 12% for human teeth samples (n=5) and 15.8% for hair samples (n=5). The method’s accuracy was investigated by using NIES-13 and by spiking the samples with different amounts of methylmercury. The results were in good agreement with the certified values and the recoveries were 88–95%.  相似文献   

17.
Paeonol is the active component in the traditional Chinese medicines (TCMs), such as Cynanchum paniculatum, which has been used to treat many diseases, such as eczema. In this work, a simple, rapid and sensitive method was developed for the determination of paeonol in rabbit plasma, which was based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The extraction parameters of fiber coating, sample temperature, extraction time, stirring rate and ion strength were systemically optimized; the method linearity, detection limit and precision were also investigated. It was shown that the proposed method provided a good linearity (0.02-20 μg mL−1, R2 > 0.990), low detection limit (2.0 ng mL−1) and good precision (R.S.D. value less than 8%). Finally, GC/MS following HS-SPME was applied to fast determination of paeonol in rabbit plasma at different time point after oral demonstration of Cynanchum paniculatum essential oil. The experimental results suggest that the proposed method provided an alternative and novel approach to the pharmacokinetics study of paeonol in the TCMs.  相似文献   

18.
Sulfur is most sensitively determined at 180.7 nm, the detection limit being 10 μg l?1. A comparison of digestion procedures shows that acid digestion in a teflon bomb gives least loss of analyte. Only calcium interferes spectrally at this wavelength. Results for various reference materials are presented.  相似文献   

19.
Fei Zheng 《Talanta》2007,73(2):372-379
A novel sol-gel 3-mercaptopropyltrimethoxysilane (MPTS) modified silica coating was developed for capillary microextraction (CME) of trace Cu, Hg and Pb prior to their on line determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES). This organic-inorganic hybrid coating was in situ created on the inner walls of fused silica capillary using a sol solution containing TMOS (tetramethoxysilane) as a precursor, MPTS as a co-precursor, ethanol as the solvent and hydrochloric acid as a catalyst. The structure of the capillary coating was characterized by FT-IR spectroscopy, Raman spectroscopy, SEM and TEM. The factors affecting on the capillary microextraction of analytes such as pH, sample flow rate and volume, elution solution and interfering ions had been investigated, and the optimized experimental parameters were obtained. Under the optimized conditions, the absorption capacity of MPTS-silica coated capillary was found to be 1.17, 1.96 and 1.19 μg m−1 for Cu, Hg and Pb, and the limits of detection were as low as 0.17 0.22 and 0.52 ng mL−1, respectively. With a sampling frequency of 12 h−1, the relative standard deviations (R.S.D.s) were 4.2, 2.6 and 3.8% (C=4 ng mL−1, n = 7, sample volume = 1 mL) for Cu, Hg and Pb, respectively. The proposed method had been successfully applied to the determination of Cu, Hg and Pb in human urine, human serum and preserved egg. To validate the proposed method, certified reference materials of BCR151 milk powder, GBW07601 (GSH-1) human hair, GSBZ 50016-90 and GSB 07-1183-2000 water samples were analyzed and the determined values were in a good agreement with the certified values.  相似文献   

20.
A new method is described for the qualitative and quantitative analysis of midazolam, a short-acting 1,4-imidazole benzodiazepine, in human plasma. It involves a plasma deproteinization step, solid-phase microextraction (SPME) of midazolam using an 85-microm polyacrylate fiber, and its detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode, using pinazepam as internal standard. The assay is linear over a midazolam plasma range of 1.5-300 ng/mL, relative intra- and inter-assay standard deviations at 5 ng/mL are below 7%, and the limit of detection is 1 ng/mL. The method is simple, fast and sufficiently sensitive to be applied in clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号