首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Several parallel imaging techniques such as SMASH, SENSE, k-space inherited parallel acquisition (KIPA) and others use reference (calibration) scans to find the parameters required for image reconstruction. Reference data is used to estimate coil sensitivity profiles for image domain techniques such as SENSE or reconstruction coefficients for k-space domain methods such as SMASH and KIPA. Any motion between the reference and accelerated imaging scans can make the reconstruction coefficients determined from the reference scan data suboptimal, resulting in an artifactual reconstruction. This work aims at comparing the effects of motion on the performance of three parallel imaging methods: SENSE, variable-density SENSE and KIPA, which all require one or more reference scans for calibration.  相似文献   

2.
The purpose of this study is to evaluate the ability of T2 turbo spin echo (TSE) axial and sagittal BLADE sequences in reducing or even eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MRI examinations. Forty four patients, who had routinely undergone a lumbar spine examination, participated in the study. The following pairs of sequences with and without BLADE were compared: a) T2 TSE Sagittal (SAG) in thirty two cases, and b) T2 TSE Axial (AX) also in thirty two cases. Both quantitative and qualitative analyses were performed based on measurements in different normal anatomical structures and examination of seven characteristics, respectively. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion, pulsatile flow and cross-talk artifacts was evaluated. Based on the results of the qualitative analysis for the different sequences and anatomical structures, the BLADE sequences were found to be significantly superior to the conventional ones in all the cases. The BLADE sequences eliminated the motion artifacts in all the cases. In our results, it was found that in the examined sequences (sagittal and axial) the differences between the BLADE and conventional sequences regarding the elimination of motion, pulsatile flow and cross-talk artifacts were statistically significant. In all the comparisons, the T2 TSE BLADE sequences were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable of potentially eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MR images and producing high quality images in collaborative and non-collaborative patients.  相似文献   

3.
4.
5.
Forty-one patients with suspected cervical spine disorders were studied using multislice gradient echo imaging (GE) technique, with a 1.5-T system. The images were compared to cardiac-gated spin echo (CGSE) images in the diagnosis of suspected cord and spinal disorders. Images were graded for ability to detect cord lesion, cord-CSF contrast, CSF-bone contrast and contrast between CSF and extradural abnormality. The signal-to-noise ratio and contrast-to-noise ratio were used to compare images. There was 44% decrease in contrast between cord lesion and normal cord on GE when compared to CGSE, except for spinal cord hemorrhage. There was a 40% improvement between bone and CSF contrast on GE compared to CGSE. GE images were significantly better qualitatively as well as quantitatively in the detection of extradural lesions. This effect was more marked in axial plane where CGSE images are extremely suboptimal. CGSE images are better than GE for spinal cord lesions, while GE are superior in the diagnosis of degenerative disease in the cervical spine.  相似文献   

6.
7.
8.
In PROPELLER, raw data are collected in N strips, each locating at the center of k-space and consisting of Mx sampling points in frequency encoding direction and L lines in phase encoding direction. Phase correction, rotation correction, and translation correction are used to remove artifacts caused by physiological motion and physical movement, but their time complexities reach O(Mx × Mx × L × N), O(N × RA × Mx × L × (Mx × L + RN × RN)), and O(N × (RN × RN + Mx × L)) where RN × RN is the coordinate space each strip gridded onto and RA denotes the rotation range. A CUDA accelerated method is proposed in this paper to improve their performances. Although our method is implemented on a general PC with Geforce 8800GT and Intel Core(TM)2 E6550 2.33 GHz, it can directly run on more modern GPUs and achieve a greater speedup ratio without being changed. Experiments demonstrate that (1) our CUDA accelerated phase correction achieves exactly the same result with the non-accelerated implementation, (2) the results of our CUDA accelerated rotation correction and translation correction have only slight differences with those of their non-accelerated implementation, (3) images reconstructed from the motion correction results of CUDA accelerated methods proposed in this paper satisfy the clinical requirements, and (4) the speed up ratio is close to 6.5.  相似文献   

9.
Cortical activation in visual association areas known to be responsible for the perception of motion was investigated in two volunteers who viewed a projected animated cartoon periodically “run” and “frozen” during collection of echoplanar MR images. Ten axial, contiguous, 5 mm thick, T2-weighted, gradient-echo images (TE 40 ms, TR 3000 ms) depicting BOLD contrast were acquired through the occipital lobe using a GE Signa 1.5 T system with an advanced NMR operating console. Images were analysed by time series regression modelling estimating power in the MR signal at the ON-OFF frequency of motion. Highly significant activation in response to motion perception was identified in both subjects bilaterally in area V5.  相似文献   

10.
The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (COR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE COR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images.  相似文献   

11.
Diffusion tensor echo planar magnetic resonance imaging of the inferior brain regions and the spinal cord suffers from tissue-air and tissue-bone interfaces, which cause severe susceptibility-induced artifacts. These artifacts consist of image distortions in the phase encode direction and also affect signal intensity. To correct for these distortions, we used the reversed gradient method. We find that most in-plane voxel displacements in the inferior brain regions and the cervical spine can be corrected, yielding a good match of white matter fiber tracts with anatomical reference images. Furthermore, uninterrupted white matter fiber tracts going from the cervical spine up to cortical areas, derived from data acquired in a single acquisition, are presented.  相似文献   

12.
T2-weighted carotid artery images acquired using the turbo spin-echo (TSE) sequence frequently suffer from motion artifacts due to respiration and blood pulsation. The possibility of using HASTE sequence to achieve motion-free carotid images was investigated. The HASTE sequence suffers from severe blurring artifacts due to signal loss in later echoes due to T2 decay. Combining HASTE with parallel acquisition (PHASTE) decreases the number of echoes acquired and thus effectively reduces the blurring artifact caused by T2 relaxation. Further improvement in image sharpness can be achieved by performing T2 decay compensation before reconstructing the PHASTE data. Preliminary results have shown successful suppression of motion artifacts with PHASTE imaging. The image quality was enhanced relative to the original HASTE image, but was still less sharp than a non-motion-corrupted TSE image.  相似文献   

13.
14.
The radiologic, CT, MR, and histological features of a case of chondrosarcoma of the femur presenting in childhood are reported. This case emphasizes the use of correlative imaging in establishing the diagnosis as well as the value of MR supplemented by Gadolinium-DTPA enhancement in disclosing abundant necrosis within the tumor.  相似文献   

15.
16.
17.
Pediatric oncology patients with large metallic prostheses were imaged with one of two MR imaging techniques: 1) the "tilted view-angle" technique, 2) or a higher readout bandwidth technique. The tilted view-angle method uses an additional gradient in the slice selection direction during readout. The high bandwidth technique increases the readout bandwidth and shortens the echo time (TE). High bandwidth and short echo times were implemented in both T(1)-weighted (T(1)W) turbo spin echo and turbo short tau inversion recovery (STIR) sequences. Both imaging techniques reduced the size of metal-induced image artifacts. The tilted view-angle method reduced the artifact to a greater degree but had inherent shortcomings. The reformatted images were blurred and shifted. The area of interest was often moved outside of the field of view, unless parameters were adjusted on the basis of a pre-scan calculation. The high readout bandwidth, short echo technique required no special preparation and reduced metal artifacts without image blurring. The combination of high-bandwidth, shorter echo turbo STIR and T(1)W turbo spin echo sequences with subtraction of pre- from post-contrast images allowed effective fat suppression without local field inhomogeneity affects. This greatly improved our ability to evaluate suspected disease near metallic implants in pediatric cancer patients.  相似文献   

18.
19.
Chorioangioma: antenatal diagnosis with fast MR imaging   总被引:2,自引:0,他引:2  
We report a case of chorioangioma of the placenta, in which fast magnetic resonance imaging (MRI) was useful adjunct to ultrasonography for the antenatal diagnosis. MRI allowed clear demonstration of 6.8 x 6.0 cm solid placental mass along with hydramnios and anatomically normal fetus. On T(1)-weighted breath-hold spoiled gradient-echo (fast low-angle shot [FLASH]) images, chorioangioma was mostly isointense to the placenta, but had an area of high signal intensity near the base and at the periphery, suggestive of hemorrhage. On T(2)-weighted half-Fourier single-shot fast spin echo (HASTE) images, the mass showed heterogeneous high signal intensity, but had an area of low signal intensity near the surface.  相似文献   

20.
Cytological features such as cell size and intracellular morphology provide fundamental information on cell status and hence may provide specific information on changes that arise within biological tissues. Such information is usually obtained by invasive biopsy in current clinical practice, which suffers several well-known disadvantages. Recently, novel MRI methods such as IMPULSED (imaging microstructural parameters using limited spectrally edited diffusion) have been developed for direct measurements of mean cell size non-invasively. The IMPULSED protocol is based on using temporal diffusion spectroscopy (TDS) to combine measurements of water diffusion over a wide range of diffusion times to probe cellular microstructure over varying length scales. IMPULSED has been shown to provide rapid, robust, and reliable mapping of mean cell size and is suitable for clinical imaging. More recently, cell size distributions have also been derived by appropriate analyses of data acquired with IMPULSED or similar sequences, which thus provides MRI-cytometry. This review summarizes the basic principles, practical implementations, validations, and example applications of MR cell size imaging based on TDS and demonstrates how cytometric information can be used in various applications. In addition, the limitations and potential future directions of MR cytometry are identified including the diagnosis of nonalcoholic steatohepatitis of the liver and the assessment of treatment response of cancers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号