首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Hasebe Y  Nawa K  Ujita S  Uchiyama S 《The Analyst》1998,123(8):1775-1780
The principle of the signal amplification of a uric acid sensor based on dithiothreitol (DTT)-mediated intermediate regeneration of uricase was applied to a flow-injection system with an immobilized uricase reactor and a DTT-containing carrier. Highly sensitive detection for nM to microM order of uric acid was achieved when 10 mM TRIS-HCl buffer (pH 10.0) containing 20 mM DTT was used as a carrier at 0.6 ml min-1 and 37 degrees C. The sensitivity of the uric acid was much improved over a batch method using a uricase membrane-coupling electrode, and the detection limit (ca. peak current 8 nA) of uric acid was found to be down to 3 x 10(-10) M (amplification factor; more than 10,000). This chemically amplified flow-system is very useful for the direct assay of uric acid in highly diluted biological fluids (urine and serum) without complicated pretreatment of the samples, because this sensor has the potential to detect trace amounts (nM to microM) of uric acid in highly diluted body fluids in which the concentration of interfering constituents was decreased to negligible levels. Good correlation was observed between this system and conventional spectrophotometry. The immobilized uricase reactor could be re-used for at least 4 months of repeated analysis without loss of activity and was stable if stored at 4 degrees C in 10 mM TRIS-HCl buffer, pH 9.0.  相似文献   

2.
Potential cycling in the range from -0.2 to +1.2 V is used for the electrodeposition of hydrous iridium oxide films onto a screen-printed electrode from a saturated solution of alkaline iridium(III) solution. The iridium oxide redox couple shows a stable and obvious reversible redox, with the formal potential being pH dependent in the range 1-14. The properties, stability and electrochemical properties of iridium oxide films were investigated by cyclic voltammetry. A modified electrode showed excellent catalytic activity toward the oxidation of neurotransmitters (catecholamines) over a wide pH range (2-8). The electrocatalytic behavior is further exploited as a sensitive detection scheme for adrenaline and dopamine by hydrodynamic amperometry. Under the optimized conditions, the calibration curves are linear in the concentration range 0.1-70 and 0.1-15 microM for dopamine and adrenaline determination, respectively. The detection limit and sensitivity are 30 nM and 30 nA/microM for adrenaline and 15 nM and 80 nA/microM for dopamine. Finally, the analytical performance of the modified electrode was demonstrated for the elimination of interference by uric acid in catecholamines determination when present in a 1000-fold concentration excess.  相似文献   

3.
Plasma and blood xanthine and hypoxanthine levels were assayed using a sensitive and specific method involving gas chromatography-mass spectrometry, associated with an optimized sample preparation procedure. Physiological variation was studied in 224 subjects with no purine metabolism disorders. An age dependency for both compounds was found, comparable with that known for uric acid. The mean plasma levels for the 224 subjects were 0.65 +/- 0.24 microM for xanthine and 1.65 +/- 0.78 microM for hypoxanthine. Corresponding mean blood levels were 0.59 +/- 0.21 microM for xanthine and 1.72 +/- 0.74 microM for hypoxanthine. Plasma and blood levels were significantly different, by ca. 10%. Rapid in vitro release of hypoxanthine from erythrocytes and continuation of intraerythrocytal metabolism lead to overestimation exceeding 10% within half an hour after sample blood collection. Hence samples must be deproteinized promptly. Blood can therefore be conveniently used for oxypurine assay instead of plasma when prompt spinning of samples is difficult to manage, as is usually encountered in clinical practice.  相似文献   

4.
A liquid chromatographic (LC) method was developed for the determination of allantoin, uric acid, and indoxyl sulfate in mammalian urine contaminated packaging material including paper bagging, corrugated cardboard, grayboard, and burlap bagging. The procedure involves solvent extraction and isolation of the 3 analytes by reversed-phase LC with ultraviolet detection at 225 nm for allantoin and 286 nm for uric acid and indoxyl sulfate. The composition of authentic mammalian urine such as mouse, rat, cat, dog, and human were also determined with regard to the 3 compounds of interest. A linear concentration range of 0.11-20.4, 0.02-10.0, and 0.04-30.0 microg/mL was obtained for allantoin, uric acid, and indoxyl sulfate, respectively. Limits of detection (LOD) and quantitation (LOQ) were 0.0104 and 0.0345 microg/mL for allantoin; 0.0018 and 0.0060 microg/mL for uric acid; and 0.0049 and 0.0165 microg/mL for indoxyl sulfate, respectively. Interday relative standard deviation values for a mixture of standard allantoin, uric acid, and indoxyl sulfate (n = 5) were 0.97, 0.80, and 0.94%, respectively. Analyte composition for 5 types of authentic mammalian urine varied from 0.19-6.88 mg/mL allantoin; 0.08-0.57 mg/mL uric acid; and 0.03-0.78 mg/mL indoxyl sulfate. Analyte content for 8 samples including 2 samples each for paper, cardboard, grayboard, and burlap bagging each contaminated with mouse or rat urine ranged from 相似文献   

5.
An electrochemical method suitable for the simultaneous measurement of cerebral glucose, lactate, L-glutamate and hypoxanthine concentrations from in vivo microdialysis sampling has been successfully performed for the first time using a neutral red-doped silica (NRDS) nanoparticle-derived enzyme sensor system. These uniform NRDS nanoparticles (about 50±3 nm) were prepared by a water-in-oil (W/O) microemulsion method, and characterized by a TEM technique. The neutral red-doped interior maintained its high electron-activity, while the exterior nano-silica surface prevented the mediator from leaching out into the aqueous solution, and showed high biocompability. These nanoparticles were then mixing with the glucose oxidase (GOD), lactate oxidase (LOD), L-glutamate oxidase (L-GLOD) or xanthine oxidase (XOD), and immobilized on four glassy carbon electrodes, respectively. A thin Nafion film was coated on the enzyme layer to prevent interference from molecules such as ascorbic acid and uric acid in the dialysate. The high sensitivity of the NRDS modified enzyme electrode system enables the simultaneous monitoring of trace levels of glucose, L-glutamate, lactate and hypoxanthine in diluted dialysate samples from a rat striatum.  相似文献   

6.
A column-switching liquid chromatographic method for the simultaneous determination of uric acid and creatinine in human serum and urine was developed. Creatinine and uric acid were separated by size-exclusion chromatography on a hydrophilic gel column (C1) and creatinine eluted from Cl was separated from proteins by filtration through a longer hydrophilic gel column (C2). The creatinine fraction eluted from C2 was transferred to a weakly acidic cation-exchange column (C3) and then to a strongly acidic cation-exchange column (C4). Uric acid eluted from Cl after creatinine was transferred to an anion-exchange column (C5) and then to a hydrophilic gel column (C6). The mobile phase was a mixed buffer of pH 5.1 (propionic acid-succinic acid-NaOH, 60:15:60 mmol/1 in water). Diluted serum and urine could be injected onto C1, and Cl was backflushed after the transfer of uric acid from Cl to C5.

Creatinine and uric acid in the eluate were determined by measuring their ultraviolet absorption at 234 and 290 nm, respectively. The recovery of uric acid and creatinine added to diluted serum (20-fold dilution, concentration 20 and 5 μmol/1, respectively) was 98.9±0.56% and 100.9±1.29%, respectively. The recovery of uric acid and creatinine added to diluted urine (100-fold dilution, concentration 50 and 100 μmol/l, respectively) was 99.4±0.72% and 98.7±1.45%, respectively (mean±R.S.D., n=6).  相似文献   


7.
A procedure is described for the rapid and simultaneous determination of allantoin, creatinine, uric acid, hypoxanthine and xanthine in sheep urine. Separation was achieved on a Novapak C18 column under isocratic conditions. The mobile phase was potassium phosphate buffer (10 mM, pH 4.0). A flow-rate of 0.5 ml/min, detection at 218 nm and a column temperature of 25 degrees C were employed with a total analysis time of less than 15 min. Detection limits for allantoin, creatinine, uric acid, hypoxanthine and xanthine were 1.0, 0.5, 0.5, 0.5 and 0.2 micrograms/ml, respectively, at a signal-to-noise ratio of 3 in a 20-microliters injection volume of tenfold-diluted urine. This sensitivity permits the precise determination of these compounds in ruminants' urine.  相似文献   

8.
A new high-performance capillary zone electrophoretic assay for creatine (Cr), creatinine (Cn), urea (U) and uric acid (Ua), markers of human diabetic nephropathy, both in plasma and urine has been developed with UV detection at 200 nm. The plasma sample was deproteinized with trichloroacetic acid and centrifuged at 10 000 rpm for 10 min. The urine sample was diluted 20-fold with buffer before analysis. The optimum separation conditions for the markers was investigated with respect to the concentration of the buffer, the pH, the voltage and the capillary temperature. Baseline separation was achieved in 25 mmol/L phosphate buffer (pH 3.45) using a 21 cm x 75 microm I.D. fused-silica capillary at 40 degrees C with an electric field of 1190 V/cm. The calibration curves showed good linearity in the range 3.5-1000, 0.18-700, 500-5000 and 2-800 microM (r2 min > 0.998) for Cr, Cn, U and Ua, respectively. The proposed method also has a high reproducibility (peak area RSD max < 3%) and has been successfully applied to the determination of clinical samples.  相似文献   

9.
A novel chemiluminescence (CL) flow sensor for the determination of uric acid in human urine and serum has been developed by using controlled-reagent-release technology. The reagents involved in the chemiluminescence (CL) reaction, luminol and periodate, are immobilized on anion-exchange resin packed in a column. After injection of water, chemiluminescence generated by released luminol and periodate in alkaline media is inhibited in presence of uric acid. By measuring the decreased chemiluminescence (CL) intensity the uric acid is sensed. The decreased response is linear in the 5.0-500.0 ng mL(-1) range, with a detection limit of 1.8 ng mL(-1). The flow sensor showed remarkable operational stability and could be easily reused for over 80 h with sampling frequency of 100 h(-1). The proposed sensor was applied to the determination of uric acid in human urine and serum, and monitoring metabolic uric acid in human urine with RSD less than 3.0%.  相似文献   

10.
Poly(dimethylsiloxane) microfluidic channels alternately modified by poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate) were successfully used to separate uric acid and ascorbic acid. Results show that uric acid and ascorbic acid can be well separated and detected simultaneously in modified microchips coupled with in-channel electrochemical detection. Under the optimal conditions, the linear ranges of uric acid and ascorbic acid were both from 25 to 600 microM, with the correlation coefficients of 0.997 and 0.996, respectively. The detection limits were 8 microM for uric acid and 5 microM for ascorbic acid. Factors influencing separation and detection, including buffer solution, detection potential and separation voltage, were investigated and optimized. In addition, the dependences of the current response on sensitivity and reproducibility were studied, and the stability of the device was also evaluated in detail. This method was successfully used to determine uric acid and ascorbic acid in human urine.  相似文献   

11.
Clinical studies have linked irregular concentrations of uric acid in urine to several diseases. Conventional methods for the measurement of uric acid are however temperature-dependent, expensive, and require labile reagents. The miniaturization of analytical techniques, specifically capillary electrophoresis, offers an ideal alternative for clinical analyses such as uric acid determination. The added benefits include reduced reagent and analyte consumption, decreased maintenance costs, and increased throughput and portability. A microchip capillary electrophoresis-electrochemical system for the analysis of uric acid in urine is described. The poly(dimethylsiloxane) (PDMS)/glass microchip utilizes amperometric detection via an off-chip platinum working electrode. Linear responses from 1 to 165 microM and 15 to 110 microM were found for dopamine and uric acid, respectively. The limit of detection for both compounds was 1 microM. Once characterized, the system was used to measure the concentration of uric acid in a dilute urine sample in less than 30 s. The measured uric acid concentration was verified with the uricase reaction and found to be acceptable. Six additional urine samples were evaluated with the microchip device and the uric acid concentration for each sample was found to be in the expected clinical concentration range.  相似文献   

12.
The coulometric determination of uric acid in human urine is done using porous carbon felt electrodes containing electrolyte. The diluted human urine is dropped on the carbon felt surface and uric acid is completely electrically oxidized in a few minutes. The coulombs consumed by interferences contained in human urine are determined by measuring the electrolytic oxidation of the same diluted human urine to which uricase is added. The current efficiencies of uric acid are nearly 100% (RSD < 1%). The results are in fairly good agreement with those obtained by sepectrophotometry.  相似文献   

13.
Electrodes for the dopamine (DA) determination in biological samples have been developed with improved selectivity and sensitivity in an excess of ascorbic acid (AA). Negatively charged Ni(II) complex was synthesized and electropolymerized on the glassy carbon electrode to impart the surface with anionic characteristics that could act both as a catalyst and as a discriminating layer against AA based on the electrostatic interaction. Thus prepared electrodes enabled selective determination of DA even in a large excess of AA by differential pulse voltammetry at physiological pH. Linear response was found down to 1.0 x 10(-7) M with 5.0 x 10(-9) M of LOD (Limit of Detection). In a flow injection analysis performed in an amperometric mode, the detection limit was lowered by two orders of magnitude down to 1.0 x 10(-9) M with a linear range of 1.0 x 10(-9) to 1.0 x 10(-6) M. The relative standard deviation was found to be 3.36% from 25 independent measurements for 1.0 x 10(-5) M of DA. Stable oxidation current of DA was observed even after 30 days storage in air. The recoveries of DA in the 100-fold diluted human urine samples were 97.7% for 4 measurements. The rate constant for the DA oxidation was 1.3 x 10(-3) cm s(-1) from hydrodynamic experiments using a rotating disk electrode.  相似文献   

14.
As an important biomarker in urine, the level of uric acid is of importance for human health. In this work, a Cu(II) functionalized metal–organic framework (Cu2+@Tb-MOFs) is designed and developed as a novel fluorescence probe for wide-range uric acid detection in human urine. The study shows that this fluorescence platform demonstrated excellent pH-independent stability, high water tolerance, and good thermal stability. Based on the strong interaction between metal ions and uric acid, the designed Cu2+@Tb-MOFs can be employed as efficient turn-on fluorescent probes for the detection of uric acid with wide detection range (0~104 µM) and high sensitivity (LOD = 0.65 µM). This probe also demonstrates an anti-interference property, as other species coexisted, and the possibility for recycling. The sensing mechanisms are further discussed at length. More importantly, we experimentally constructed a molecular logic gate operation based on this fluorescence probe for intelligent detection of uric acid. These results suggest the Cu(II) functionalized metal–organic framework can act as a prominent candidate for personalized monitoring of the concentration of uric acid in the human urine system.  相似文献   

15.
Fabrication and characterization of miniature, flexible, planar biosensors for monitoring l-lactate accumulation in an ischemic myocardium are described. Three configurations of Au-based electrodes were fabricated by a photolithographic technique on flexible polyimide Kapton((R)) foil. All sensors are based on an immobilized lactate oxidase with amperometric detection of the enzymatically produced hydrogen peroxide at a platinum-electroplated-gold base electrode polarized at 0.5 V versus Ag/AgCl. An inner electropolymeric layer is used to prevent electrode fouling and to reject the interference effects of easily oxidizable molecules. In addition, a diffusion controlling outer layer that greatly enhances the linear dynamic range of the sensor, is obtained by casting a polyurethane external film. The developed sensor was evaluated in vitro and proved to have high selectivity, good operational stability, good accuracy and precision (average recovery = 102.3 +/- 0.4% for control sera), fast response time (t(95) = 20 s) and high upper limit of the linear dynamic range (25-80 mM, with sensitivity of 1.7-0.4 nA mM(-1) respectively at PO(2) = 15 mmHg). Subsequently, the sensor was brought into direct contact with the surface of the rabbit papillary muscle and used for continuous quantitative monitoring of extracellular lactate accumulation during no-flow ischemia.  相似文献   

16.
基于酸性条件下甲醛对尿酸-KMnO4发光反应的增敏作用,建立了在线稀释顺序注射化学发光联用技术测定人体液中尿酸的新方法。在选定的实验条件下的7个浓度梯度范围内,尿酸浓度在5.0×10-6mol/L~1.0×10-3mol/L范围内与发光强度呈良好线性关系,相关系数0.9942~0.9998,RSD在2.0%~3.5%之间,回收率为98.0%~103.0%。每小时可分析80个样品,在线稀释测定结果与手工稀释法一致。  相似文献   

17.
Salimi A  Mamkhezri H  Hallaj R 《Talanta》2006,70(4):823-832
A sol-gel carbon composite electrode (CCE) has been prepared by mixing a sol-gel precursor (e.g. methyltrimethoxysilane) and carbon powder without adding any electron transfer mediator or specific reagents. It was demonstrated that this sensor can be used for simultaneous determination ascorbic acid, neurotransmitters (dopamine and adrenaline) and uric acid. Direct electrochemical oxidation of ascorbic acid, uric acid and catecholamines at a carbon composite electrode was investigated. The experimental results were compared with other common carbon based electrodes, specifically, boron doped diamond, glassy carbon, graphite and carbon paste electrodes. It was found that the CCE shows a significantly higher of reversibility for dopamine. In addition, in comparison to the other electrodes used, for CCE the oxidation peaks of uric acid, ascorbic acid and catecholamines in cyclic and square wave voltammetry were well resolved at the low positive potential with good sensitivity. The advantages of this sensor were high sensitivity, inherent stability and simplicity and ability for simultaneous determination of uric acid, catecholamines and ascorbic acid without using any chromatography or separation systems. The analytical performance of this sensor has been evaluated for detection of biological molecules in urine and serum as real samples.  相似文献   

18.
Electroanalytical methods can be used for the reliable detection of the toxic heavy metal lead in drinking water samples. Inkjet printed electrodes have potential for the rapid and affordable assessment of drinking water. Researchers have shown the electrochemical sensing applicability of inkjet printed electrodes. In this work, Pb2+ was detected using an inkjet printed multi‐walled carbon nanotube (IJP‐MW‐CNT) electrode with silver tracks printed underneath. The silver tracks provide the sensor with the conductivity needed for sensitive measurements. MW‐CNT were dispersed in water using bile salts as a surfactant to prepare the ink. The IJP‐MW‐CNT electrode was used as the working electrode with a platinum wire and Ag/AgCl as auxiliary and reference electrode, respectively. The electrodes performance was optimized in 0.1 M acetate buffer (pH=4.3) and had two linear ranges of 5 to 20 ppb (R2=0.99) with a sensitivity of 38 nA/ppb and 20 to 50 ppb (R2=0.98) with a sensitivity of 15 nA/ppb and a limit of detection (LOD) of 1.0 ppb for Pb2+. The analytical applicability of electrode was determined by constructing a calibration curve in an unaltered drinking water sample (i. e.) Cincinnati tap water with two linear ranges of 15 to 40 ppb (R2=0.99) with a sensitivity of 1.5 nA/ppb and 40 to 70 ppb (R2=0.99) with a sensitivity of 3.5 nA/ppb and a LOD of 1.0 ppb for Pb2+. Effects of copper and cadmium as potential interferents are reported.  相似文献   

19.
We fabricated a sensitive and selective electrochemical carbon monoxide (CO) sensor for physiological conditions based on the Pt-Ru system. At a bare Pt-Ru electrode, a linear amperometric response to CO concentration was obtained in the range of 0.9-9 μM. However, significant current response to model electroactive interferents for physiological conditions, uric acid (UA), ascorbic acid (AA) and hydrogen peroxide (HP), was also recorded at the Pt-Ru electrode. The response to UA and AA was highly suppressed by coating the Pt-Ru electrode surface with a Nafion layer, and the response to HP was almost completely eliminated by the additional coating with a MnO(2)/chitosan layer. Finally, at the Pt-Ru/Nafion/MnO(2) electrode, amperometric CO detection with a sensitivity of 173 nA cm(-2) μM(-1) was obtained in the concentration range of 0.9-9 μM with the UA, AA and HP signal being below 1.7% at the same concentration of CO.  相似文献   

20.
For the purpose of rapid drug monitoring, methods have been developed for the determination of 2,8-dihydroxyadenine, allopurinol, oxypurinol, adenine, hypoxanthine, hippuric acid and xanthine in urine with and without sodium dodecyl sulfate as additive in sodium tetraborate running buffer. No sample preparation is necessary. 6-methylmercaptopurine and etofylline have been used as the internal standards. The limit of detection is 5 microM and the range of quantification stretches from 20 to 2000 microM. The capillary electrophoresis methods are simple, fast and robust.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号