首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Niu CG  Gui XQ  Zeng GM  Yuan XZ 《The Analyst》2005,130(11):1551-1556
This paper describes a novel ratiometric fluorescence sensor for pH measurement. Two pH-sensitive fluorophores, N-allyl-4-(4'-methyl-piperazinyl)-1,8-naphthalimide (AMPN) and meso-5,10,15,20-tetra-(4-allyloxyphenyl)porphyrin (TAPP), which served as referencing indicators for each other, were co-polymerized with acrylamide, hydroxyethyl methacrylate and triethylene glycol dimethacrylate on the silanized glass surface. The proposed sensor is based on the pH-dependent fluorescence intensities of the two fluorophores in different pH ranges. The sensor covers a broad dynamic range of pH 1.5-9.0. It exhibits satisfactory analytical performance in terms of selectivity, reproducibility and stability. The successful fabrication of the proposed sensor provides an alternative concept to utilizing two or more fluorophores for the development of ratiometric sensors covering a broad range of pH.  相似文献   

2.
The communication describes the synthesis and studies of 9-piperazine substituted perylene-3,4-dicarboximide (1). In aqueous solution, the ratio of fluorescence emission intensities from the localized excited state (~585 nm) to the charge transfer excited state (~695 nm) increases in the pH range of 7.5-9. Furthermore, compound 1 may be used for ratiometric detection of double-stranded DNA.  相似文献   

3.
Dual-excitation ratiometric fluorescent probes allow the measurement of fluorescence intensities at two excitation wavelengths, which should provide a built-in correction for environmental effects. However, most of the small-molecule dual-excitation ratiometric probes that have been reported thus far have shown rather limited separation between the excitation wavelengths (20-70 nm) and/or a very small molar absorption coefficient at one of the excitation wavelengths. These shortcomings can lead to cross-excitation and thus to errors in the measurement of fluorescence intensities and ratios. Herein, we report a FRET-based molecular strategy for the construction of small-molecule dual-excitation ratiometric probes in which the donor and acceptor excitation bands exhibit large separations between the excitation wavelengths and comparable excitation intensities, which is highly desirable for determining the fluorescence intensities and signal ratios with high accuracy. Based on this strategy, we created a coumarin-rhodamine FRET platform that was then employed to develop the first class of FRET-based dual-excitation ratiometric pH probes that have two well-resolved excitation bands (excitation separations>160 nm) and comparable excitation intensities. In addition, these pH probes may be considered as in a kind of "secured ratioing mode". As a further application of these pH probes, the dual-excitation ratiometric pH probes were transformed into the first examples of photocaged dual-excitation ratiometric pH probes to improve the spatiotemporal resolution. It is expected that the modular nature of our FRET-based molecular strategy should render it applicable to other small-molecule dual-dye energy-transfer systems based on diverse fluorescent dyes for the development of a wide range of dual-excitation ratiometric probes with outstanding spectral features, including large separations between the excitation wavelengths and comparable excitation intensities.  相似文献   

4.
The homeostasis of mitochondrial pH (pHm) is crucial in cell physiology. Developing small-molecular fluorescent sensors for the ratiometric detection of pHm fluctuation is highly demanded yet challenging. A ratiometric pH sensor, Mito-pH, was constructed by integrating a pH-sensitive FITC fluorophore with a pH-insensitive hemicyanine group. The hemicyanine group also acts as the mitochondria targeting group due to its lipophilic cationic nature. Besides its ability to target mitochondria, this sensor provides two ratiometric pH sensing modes, the dual excitation/dual emission mode (Dex/Dem) and dual excitation (Dex) mode, and its linear and reversible ratiometric response range from pH 6.15 to 8.38 makes this sensor suitable for the practical tracking of pHm fluctuation in live cells. With this sensor, stimulated pHm fluctuation has been successfully tracked in a ratiometric manner via both fluorescence imaging and flow cytometry.  相似文献   

5.
It is significant for cell physiology to keep the homeostasis of p H, and it is highly demanded to develop ratiometric fluorescent sensors toward p H. In this work, under mild condition, through the electrostatic interaction between carbon nanodots(CDs) and organic molecules, two novel ratiometric fluorescence hybrid nanosensors were fabricated for sensing acidic p H. These nanohybrid systems possess dual emission peaks at 455 and 527 nm under a single excitation wavelength of 380 nm in acidic p H condition.With the increasing of p H, the fluorescence of the 1,8-naphthalimide derivative completely quenches,while the blue fluorescence of CDs keeps constant. Furthermore, the CDsàorganic molecular nanohybrids exhibit excellent anti-disturbance ability, reversible p H sensing ability, and a linear response range in wide p H range respectively. Besides the ability to target lysosome, with one of the nanosensor, stimulated p H change has been successfully tracked in a ratiometric manner via fluorescence imaging.  相似文献   

6.
This article describes the design and preparation of a novel fluorescence resonance energy transfer (FRET)-based ratiometric sensor with the polymer nanoparticle as scaffold for detecting Hg2+ in aqueous media. In this study, a fluorescent dye fluorescein isothiocyanate (FITC, served as the donor) and a spirolactam rhodamine derivative (SRHB, served as mercury ion probe) were covalently attached onto polyethylenimine (PEI) and polyacrylic acid (PAA) respectively; and a ratiometric sensing system was then formed through the deposition of the donor- and probe-containing polyelectrolytes onto the negatively charged polymer particles via the layer-by-layer approach. The ratiometric fluorescent signal change of the system is based on the intra-particle fluorescence resonance energy transfer (FRET) process modulated by mercury ions. Under optimized structural and experimental conditions, the particle-based detection system exhibits stable response for Hg2+ in aqueous media. More importantly, in this newly developed particle-based detection system formed by LBL approach, varied numbers of the PAA/PEI layers which served as the spacer could be placed between the donor-containing layer and the probe-containing layer, hence the donor–acceptor distance and energy transfer efficiency could be effectively tuned (from ca. 25% to 76%), this approach has well solved the problem for many particle-based FRET systems that the donor–acceptor distance cannot be precisely controlled. Also, it is found that the ratiometric sensor is applicable in a pH range of 4.6–7.3 in water with the detection limit of 200 nM. This approach may provide a new strategy for ratiometric detection of analytes in some environmental and biological applications.  相似文献   

7.
《中国化学快报》2023,34(3):107586
Cell stress responses are associated with numerous diseases including diabetes, neurodegenerative diseases, and cancer. Several events occur under cell stress, in which, are protein expression and organelle-specific pH fluctuation. To understand the lysosomal pH variation under cell stress, a novel NIR ratiometric pH-responsive fluorescent probe (BLT) with lysosomes localization capability was developed. The quinoline ring of BLT combined with hydrogen ion which triggered the rearrangement of π electrons conjugated at low pH medium, meanwhile, the absorption and fluorescent spectra of BLT showed a red-shifts, which gived a ratiometric signal. Moreover, the probe BLT with a suitable pKa value has the potential to discern changes in lysosomal pH, either induced by heat stress or oxidative stress or acetaminophen-induced (APAP) injury stress. Importantly, this ratiometric fluorescent probe innovatively tracks pH changes in lysosome in APAP-induced liver injury in live cells, mice, and zebrafish. The probe BLT as a novel fluorescent probe possesses important value for exploring lysosomal-associated physiological varieties of drug-induced hepatotoxicity.  相似文献   

8.
A BODIPY-based ratiometric fluorescent probe for HOCl has been designed based on the transduction of thioether to sulfoxide function. This probe features a marked absorption and emission blue-shift upon the HOCl-promoted rapid transduction, enabling the highly selective and ratiometric detection. In addition, the probe works excellently within a wide pH range of 4–10, addressing the existing pH dependency issue. Living cells studies demonstrate that the probe is cell membrane permeable and can be employed successfully to image endogenous HOCl generation in macrophage cells.  相似文献   

9.
Intracellular pH affects protein structure and function, and proton gradients underlie the function of organelles such as lysosomes and mitochondria. We engineered a genetically encoded pH sensor by mutagenesis of the red fluorescent protein mKeima, providing a new tool to image intracellular pH in live cells. This sensor, named pHRed, is the first ratiometric, single-protein red fluorescent sensor of pH. Fluorescence emission of pHRed peaks at 610 nm while exhibiting dual excitation peaks at 440 and 585 nm that can be used for ratiometric imaging. The intensity ratio responds with an apparent pK(a) of 6.6 and a >10-fold dynamic range. Furthermore, pHRed has a pH-responsive fluorescence lifetime that changes by ~0.4 ns over physiological pH values and can be monitored with single-wavelength two-photon excitation. After characterizing the sensor, we tested pHRed's ability to monitor intracellular pH by imaging energy-dependent changes in cytosolic and mitochondrial pH.  相似文献   

10.
Synergistic effects arising from the conjugation of organic dyes onto non‐luminescent metal nanoparticles (NPs) have greatly broadened their applications in both imaging and sensing. Herein, we report that conjugation of a well‐known pH‐insensitive dye, tetramethyl‐rhodamine (TAMRA), to pH‐insensitive luminescent gold nanoparticles (AuNPs) can lead to an ultrasmall nanoindicator that can fluorescently report local pH in a ratiometric way. Such synergy originated from the dimerization of TAMRA on AuNPs, of which geometry was very sensitive to surface charges of the AuNPs and can be reversely modulated through protonation of surrounding glutathione ligands. Not limited to pH‐insensitive dyes, this pH‐dependent dimerization can also enhance the pH sensitivity of fluorescein, a well‐known pH‐sensitive dye, within a larger pH range, opening up a new pathway to design ultrasmall fluorescent ratiometric nanoindicators with tunable wavelengths and pH response ranges.  相似文献   

11.
Dong M  Wang YW  Peng Y 《Organic letters》2010,12(22):5310-5313
A nonsulfur probe based on a 1,8-naphthalimide and alkyne conjugate for the ratiometric fluorescent sensing for Hg(2+) and Au(3+) through the tuning of pH in different aqueous solutions is described. This work provides a novel reaction-based approach for selective recognition of these two ions with significant change of fluorescence color and constitutes the first ratiometric case for Au(3+).  相似文献   

12.
Novel ratiometric, near-infrared fluorescent pH probes with various pK(a) values have been designed and synthesized on the basis of aminocyanine bearing a diamine moiety, and their photochemical properties were evaluated. Under acidic conditions, these pH probes showed a 46- to 83-nm red shift of the absorption maximum. This change is sufficiently large to permit their use as ratiometric pH probes, and is reversible, whereas monoamine-substituted aminocyanines showed irreversible changes because of their instability under acidic conditions. Furthermore, the pK(a) values of these probes can be predicted from the calculated pK(a) values of the diamine moieties, obtained from the SciFinder database. This design strategy is very simple and flexible, and should be applicable to develop NIR pH probes for various applications.  相似文献   

13.
We have synthesized dual-fluorophore-doped core-shell silica nanoparticles used as ratiometric pH sensor. The nanoparticles were prepared with a reverse microemulsion technique by simultaneously encapsulating two different fluorophores, the pH-sensitive dye fluorescein as a pH indicator and the pH-insensitive dye phenosafranine as an internal reference for fluorescence ratiometric measurement, into silica shell. The nanoparticles prevent the fluorescence dyes leaching from the silica matrix when immersed inside water. The hydrophilic silica shells were made by hydrolysing and polymerizing tetraethoxysilane (TEOS) in water-in-oil microemulsion. The fluorescence intensity ratio of the two dyes varied linearly as a function of pH in the range from 4.0 to 8.0. The sensor was also applied to measure pH of real water samples. The results are in good agreements with that using the conventional glass electrode method. The as-prepared fluorescent nanoparticles showed rapid response, excellent stability and high reproducibility as pH sensors.  相似文献   

14.
《Tetrahedron letters》2019,60(26):1696-1701
As an important parameter of intracellular metabolism, pH plays important roles in maintaining normal physiological processes. The abnormal pH could cause disorder of cell function which may cause neurological diseases. Herein, we present two novel ratiometric fluorescent probes to detect pH changes. The probes employed 2-(2′-hydroxyphenyl)benzothiazole as fluorescent platform, and displayed desirable fluorescence response to pH on the basis of excited state intramolecular proton transfer (ESIPT) process. The probe BtyC-1 showed green fluorescence at 546 nm under acidic conditions, while it displayed strong blue fluorescence at 473 nm and weak green fluorescence at 546 nm under alkaline conditions. Biological experiments demonstrated that the probe BtyC-1 could be successfully applied for the ratiometric imaging of cellular pH and the NH4Cl-induced pH changes in living cells.  相似文献   

15.
The whole picture: Carbon nanodots labeled with two fluorescent dyes have been developed as a tunable ratiometric pH sensor to measure intracellular pH. The nanosensor shows good biocompatibility and cellular dispersibility. Quantitative determinations on intact HeLa cells and pH fluctuations associated with oxidative stress were performed.  相似文献   

16.
Tracking pH with spatiotemporal resolution is a critical challenge for synthetic chemistry, chemical biology and beyond. Over the last decade, different small probes and supramolecular systems have emerged for in cellulo or in vivo pH tracking. However, pH reporting still presents critical limitations, such as background reduction, improved sensor stability, cell targeting, endosomal escape, near- and far-infrared ratiometric pH tracking and adaption to new imaging techniques (i.e., super-resolution). These challenges will require the combined efforts of synthetic and supramolecular chemistry working together to develop the next generation of smart materials that will resolve current limitations. Herein, recent advances in the synthesis of small fluorescent probes, together with new supramolecular functional systems employed for pH tracking, are described with an emphasis on ratiometric probes. The combination of organic synthesis and stimuli-responsive supramolecular functional materials will be essential to solve future challenges of pH tracking, such as improved signal to noise ratio, on target activation and microenvironment reporting.  相似文献   

17.
A novel SciFinder-guided strategy for the preparation of pH responsive carbon dots (CDs-pH) for ratiometric intracellular imaging was developed.  相似文献   

18.
Following excitation in the range 370-405 nm, the emission spectrum of a cell permeable macrocyclic Eu(III) complex incorporating an N-methylsulfonamide moiety changes form with pH, allowing ratiometric pH measurements in the range 6 to 8.  相似文献   

19.
The pH values of lysosomes in cancer cells is slightly lower than that in normal cells, which can be used to distinguish cancer cells from normal cells. According to this, a naphthalimide-rhodamine based fluorescent probe(hereafter referred to as RBN) with a pK_a of 4.20 was designed and synthesized for ratiometric sensing of cellular pH via fluorescence resonance energy transfer(FRET), which can respond to different pH precisely through ratiometric fluorescence intensity(Ⅰ_(577)/Ⅰ_(540)). RBN can be employed to distinguish cancer cells from normal cells on the basis of different fluorescent response, in particular, RBN showed excellent water solubility and low cell toxicity, all these are quite significant for potential application in cancer diagnose and therapy.  相似文献   

20.
A color distinctive, ratiometric pH sensor was demonstrated using pH responsive and fluorescent (PyMMP-b-P2VP) diblock copolymer coated CdSe/ZnS QDs. Due to the change in the P2VP conformations in response to pH change, the color of QDs in solution changes distinctly from blue to red.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号