首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and convenient method for the determination of trace europium ions using an oscillating chemical reaction involving Ce(IV) - KBrO3 - acetone - oxalic acid - H2SO4 was proposed. The results indicated that the changes in oscillating period (T) was linearly proportional to the negative logarithmic concentration of Eu3+ (-log C) in the range of 1.41 × 10−8 ˜ 1.41 × 10−4 mol L−1 (r = 0.9982) with a detection limit of 1.04 × 10−9 mol L−1. The recoveries were limited to the range of 99.5% to 100.8%. Under the same conditions, other rare earth ions did not interfere with the determination of Eu3+. In addition, a perturbation mechanism was also discussed briefly.   相似文献   

2.
Ibuprofen membrane electrodes based on different plasticizers: diisobutyl phthalate (DIBP), o-nitrophenyloctyl ether (o-NPOE), dioctyl sebacate (DOS) and tetraoctylammonium 2-(4-isobutylphenyl)propionate were prepared. All electrodes show: a near Nernstian slope of characteristic (58.3–60.9 mV decade−1) in the measurement range (10−4–10−1 mol L−1), limit of detection (5.0×10−5 mol L−1), really long lifetime (12 months), dependence of the electrode potential on pH (5.5–9.0), reproducibility of potential (0.6–1.2 mV) and selectivity coefficients in relation to some organic and inorganic anions. The electrodes were applied for the determination of ibuprofen in tablets by the calibration curve method and the standard addition method.   相似文献   

3.
A convenient and sensitive method for determination of sulfanilamide (SNA) was described based on the Mn(II)-catalyzed oscillating chemical reaction. Under optimum conditions, a linear relationship existed between the changes of oscillating period or amplitude and the negative of logarithm of SNA concentration in the range of 4.27 × 10−8 mol ·L−1 ∼ 7.41 × 10−6 mol ·L−1 (RSD, 0.85%) and 9.33 × 10−8 mol ·L−1 ∼ 3.02 × 10−6 mol ·L1 (RSD, 1.08%), respectively. The lower limit of detection was found to be 2.69 × 10−8 mol ·L−1 and 6.03 × 10−8 mol ·L−1, respectively.   相似文献   

4.
Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were investigated for the optimal electrode: measurement range (10−4 − 10−1 mol L−1), slope of the linear range of the calibration curve (−58.3 mV decade−1), limit of detection (6.0 × 10−5 mol L−1), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 − 9.0), reproducibility of potential (1.2 mV) and selectivity coefficients in relation to selected organic and inorganic anions. The electrode was utilized for determination of naproxen in tablets by the calibration curve method and the standard addition method.   相似文献   

5.
The construction and optimization of five new types of miniaturized flow-through electrolytic cells with lead cathode and platinum anode for electrochemical hydride generation in atomic absorption spectrometry (HG-QFAAS) were achieved during this research study. The ion-exchange membrane was not part of these cells and only one carrying electrolyte for both electrode chambers was used. Hydride generation efficiency achieved was either comparable or higher than the one recorded for the classic thin-layer generation cell. The inner volume of the cathode chamber was reduced to a quarter of the classic thin-layer flow-through cell. Compared to the commonly used thin-layer flow-through cell, higher sensitivity (7.32×103 dm3 μg−1) and better limit of detection (0.32 μg dm−3) were obtained for selenium determination using two of these new generators.   相似文献   

6.
Electrochemical oxidation of methylthiomethyleneisoquinolinium chloride (MTMIQ), the first alkylthiomethyl substituted ammonium salt, which is fully miscible with water has been investigated by voltammetric (SWV) method using glassy carbon electrode. On the electrode, MTMIQ undergoes oxidation at the potential near Ep = 0.07V (vs. Ag/AgCl/3 M KCl). The influence of the pH of buffers, amplitude, frequency, step potential on the received signal was studied. The best results were obtained with a citrate buffer at a pH of 5. The oxidation peak current used for MTMIQ voltammetric determination was in the range of 2–8×10−5 mol L−1, LOD = 3.7×10−6, LOQ = 1.2×10−5. The product of the oxidation was accumulated at the working electrode and was investigated by spectroscopic method. Mechanistic pathways of the oxidation have been proposed.   相似文献   

7.
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.   相似文献   

8.
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.   相似文献   

9.
A new amperometric titration method was developed for quantitative determination of ferrate(VI) (FeVIO4 2−) in the 7.06×10−5−5.73×10−3 M concentration range. Chromium(III) hydroxide solution was used as the titrant. The diffusion current (Id) had a linear relationship with the concentration of ferrate(VI) and slopes were dependent on the concentration of NaOH. The amperometric titration could detect a lower concentration of ferrate(VI) than could potentiometric and colorimetric titrations. The method was applied successfully to determine concentrations of ferrate(VI), generated electrochemically, in strong alkaline solutions.   相似文献   

10.
This paper described the determination of p-nitroaniline in a double organic substrate oscillating system of tartrate-acetone-Mn2+-KBrO3-H2SO4. Under the optimum conditions, temperature was chosen as a control parameter to design the bifurcation point and proposed a convenient method for determination of p-nitroaniline. Results showed that the system consisting of 3.5 mL 0.06 mol L−1 tartrate, 4.0 mL 0.7 mol L−1 H2SO4, 1.5 mL 1.5×10−4 mol L−1 MnSO4, 4.0 mL 0.4 mol L−1 acetone and 7.0 mL 0.05 mol L−1 KBrO3 was very sensitive to the surrounding at 33.5°C. A good linear relationship between the potential difference and the negative logarithm concentration of p-nitroaniline was obtained to be in the range of 2.50×10−7∼3.75×10−5 mol L−1 with a lower detection limit of 2.50×10−8 mol L−1.   相似文献   

11.
The kinetics of base hydrolysis of glycine, histidine, and methionine methyl esters in the presence of [Pd(pip)(H2O)2]2+ complex, where pip is piperazine, is studied in aqueous solutions, at T = 25°C, and I = 0.1 mol dm−3. The rate of ester hydrolysis for glycine methyl ester is studied at different temperature and dioxane/water solutions of different compositions. The kinetic data are fit under the assumption that the hydrolysis proceeds in one step. The activation parameters for the base hydrolysis of the complexes are evaluated   相似文献   

12.
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation. This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).   相似文献   

13.
In this study the application of home-made unmodified (GC) and bulk modified boron doped glassy carbon (GCB) electrodes for the voltammetric determination of the linuron was investigated. The electrodes were synthesized with a moderate temperature treatment (1000°C). Obtained results were compared with the electrochemical determination of the linuron using a commercial glassy carbon electrode (GC-Metrohm). The peak potential (E p ) of linuron oxidation in 0.1 mol dm−3 H2SO4 as electrolyte was similar for all applied electrodes: 1.31, 1.34 and 1.28 V for GCB, GC and GC-Metrohm electrodes, respectively. Potential of linuron oxidation and current density depend on the pH of supporting electrolyte. Applying GCB and GC-Metrohm electrodes the most intensive electrochemical response for linuron was obtained in strongly acidic solution (0.1 mol dm−3 H2SO4). Applying the boron doped glassy carbon electrode the broadest linear range (0.005–0.1 μmol cm−3) for the linuron determination was obtained. The results of voltammetric determination of the linuron in spiked water samples showed good correlation between added and found amounts of linuron and also are in good agreement with the results obtained by HPLC-UV method. This appears to be the first application of a boron doped glassy carbon electrode for voltammetric determination of the environmental important compounds.   相似文献   

14.
A new and convenient method for the determination of Alizarin Red S by the perturbations caused by different amounts of Alizarin Red S on a novel B-Z oscillating system is proposed. This new type Belousov-Zhabotinskii involves a macrocyclic copper(II) complex [CuL](ClO4)2 as catalyst and malic acid as the substrate. The ligand L in the complex is 5,7,7,12,14,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene. It is found that the relationship between the change in the oscillation amplitude and the logarithm of the Alizarin Red S concentration in the range of 1.5 × 10−7 to 1 × 10−3 M fits a polynomial model: ΔA = 659 + 184.2 log [Alizarin Red S]+ 12.9 log2 [Alizarin Red S]. The RSD obtained with ten samples is 4.4%. The probable mechanism involving the perturbation of Alizarin Red S on the oscillating chemical system is also discussed.   相似文献   

15.
The goal was to electrospin 2-hydroxyethyl methacrylate — based biocompatible polymers and prepare submicron fibres (nanofibers) for biomedicinal applications. Syntheses of poly(2-hydroxyethyl methacrylate) (HEMA) and its copolymer with 2-ethoxyethyl methacrylate (EOEMA), and their characterization by viscometry and molecular weight are described. Their relation to electrospinning is discussed. Electrospinning of HEMA homopolymer from water-ethanol is successful for molecular weights 6.31 × 105 and 1.80 × 106 g/mol. Electrospinning of HEMA/EOEMA copolymers is feasible from ethanol.   相似文献   

16.
Preliminary results of development of a direct and fast method of determination of antimony in samples of tap water using GFAAS are presented. The found levels of antimony were lower than permitted for human consumption. A mixture of Pd and Mg(NO3)2 (concentrations in the injected solution: 8.6 μg mL−1 and 5.8 μg mL−1 respectively) was used as the chemical modifier. The pyrolysis and atomization temperatures were 1000 and 1700°C, respectively and the mean analytical recovery 98.2%.   相似文献   

17.
Titania layers obtained by a sol-gel technique doped with redox mediator, Meldola’s Blue, were employed for construction of a new NADH senor. Optimization of preparation process as well as experimental conditions affecting the response of the sensor were examined. Under optimal conditions NADH could be determined in the wide linear range from 90 to 2300 μM with detection limit 12 μM and a high sensitivity 12.5 nA μM−1. The usefulness of developed sensor was preliminarily checked in determination of NADH forming during enzymatic oxidation of ethanol catalyzed by alcohol dehydrogenase (ADH).   相似文献   

18.
Attempts were made to plasma deposit an oriented π-conjugated polymer of pyrrole (Py) on paper surfaces in order to produce electrically conductive layers. The N/C atomic ratio of 0.13–0.24 was observed for all treatment conditions. This implies the nature of the deposition formed on the paper surface via pulsed plasma is different from that of pyrrole monomer. An increase in conductivity of all pyrrole-plasma treated papers was observed. The 50 W RF-power with 5 min plasma exposed paper sample shows 8.15 × 10−9 S·cm−1 conductivity. The conductivity measurements indicated a plasma-enhanced ring-opening reaction mechanism of pyrrole.   相似文献   

19.
A simple and sensitive dispersive liquid-liquid microextraction method for extraction and preconcentration of pentachlorophenol (PCP) in water samples is presented. After adjusting the sample pH to 3, extraction was performed in the presence of 1% W/V sodium chloride by injecting 1 mL acetone as disperser solvent containing 15 μL tetrachloroethylene as extraction solvent. The proposed DLLME method was followed by HPLC-DAD for determination of PCP. It has good linearity (0.994) with wide linear dynamic range (0.1–1000 μg L−1) and low detection limit (0.03 μg L−1), which makes it suitable for determination of PCP in water samples.   相似文献   

20.
A solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectromA solid phase extraction technique for the determination of platinum(IV) at trace levels by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The method was based on retention of platinum in a sample on silica gel modified with aminepropyl groups. The retention of platinum(IV) from the sample solution and the recovery of platinum with 1.0 mol L−1 thiourea solution were quantitative. The relative standard deviation (RSD) was calculated as 5% (n = 7) at the 10 ng L−1 level. The enrichment factor was found to be (50-fold) for 250 mL of water sample. Under optimum conditions, the method detection limit (MDL) was found to be 1 ng L−1 for platinum in water matrices. Recoveries of Pt from spike addition to atmospheric water samples were quantitative (80–95%). The present method was used for the determination of platinum in precipitation, throughfall and runoff water samples.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号