首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
A novel near infrared (NIR) modeling method—Laplacian regularized least squares regression (LapRLSR) was presented, which can take the advantage of many unlabeled spectra to promote the prediction performance of the model even if there are only few calibration samples. Using LapRLSR modeling, NIR spectral analysis was applied to the online monitoring of the concentration of salvia acid B in the column separation of Salvianolate. The results demonstrated that LapRLSR outperformed partial least squares (PLS) significantly, and NIR online analysis was applicable.  相似文献   

2.
A method has been developed for measurement of the homogeneity of analyte distribution in powdered materials by use of electrothermal vaporization with inductively coupled plasma mass spectrometric (ETV–ICP–MS) detection. The method enabled the simultaneous determination of As, Cd, Cu, Fe, Mn, Pb, and Zn in milligram amounts of samples of biological origin. The optimized conditions comprised a high plasma power of 1500 W, reduced aerosol transport flow, and heating ramps below 300?°C s–1. A temperature ramp to 550?°C ensured effective pyrolysis of approximately 70% of the organic compounds without losses of analyte. An additional hold stage at 700?°C led to separation of most of the analyte signals from the evaporation of carbonaceous matrix compounds. The effect of time resolution of signal acquisition on the precision of the ETV measurements was investigated. An increase in the number of masses monitored up to 20 is possible with not more than 1% additional relative standard deviation of results caused by limited temporal resolution of the transient signals. Recording of signals from the nebulization of aqueous standards in each sample run enabled correction for drift of the sensitivity of the ETV–ICP–MS instrument. The applicability of the developed method to homogeneity studies was assessed by use of four certified reference materials. According to the best repeatability observed in these sample runs, the maximum contribution of the method to the standard deviation is approximately 5% to 6% for all the elements investigated.  相似文献   

3.
A novel, simple and sensitive method for the determination of Lusutrombopag in rat plasma using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated. The determination was performed on an API4000 triple quadrupole mass spectrometry in the multiple reaction monitoring mode using the respective [M+H]+ ions m/z 593.1 → 272.3 for Lusutrombopag. The limit of detection was 0.5 ng/mL, and the lower limit of quantification was 2.0 ng/mL in rat plasma. Good linearity was obtained over the range of 2.0–150.0 ng/mL and the correlation coefficient was found to be 0.9998. The intra and inter-day precisions were found to be 3.8–6.9% and 6.8–10.5%, respectively. The intra and inter-day accuracy derived from QC samples was found to be 2.5–4.9% and 5.5–7.2%, respectively. The analyte was stable under various conditions (at room temperature, during freeze-thaw, in the autosampler and under deep-freeze conditions). The F-test and t-test at 95% confidence level were subjected on data for statistical analysis. The developed method was successfully applied to the pharmacokinetic study in rats.  相似文献   

4.
There is substantial evidence that circulating estrogens promote the proliferation of breast cancer. Consequently, adjuvant hormonal treatment strategies targeting estrogen action have been established. Such hormonal therapies include selective estrogen receptor modulators, such as tamoxifen, which interfere at the estrogen receptors directly, or non-steroidal aromatase inhibitors, such as anastrozole and letrozole, which inhibit estrogen synthesis through blocking the aromatase, a key enzyme of estrogen production. Despite considerable therapeutic success, in several cases, the use of these drugs is limited by side effects that have been described to significantly impair the adherence of patients to endocrine treatment. However, objective data concerning patient adherence and its clinical relevance are limited. One promising approach to check patient-reported adherence is drug monitoring in human plasma. Therefore, a liquid chromatography–tandem mass spectrometry method to determine the plasma concentrations of tamoxifen, anastrozole, and letrozole has been developed and fully validated according to guidelines for clinical and forensic toxicology. The validation criteria evaluated were selectivity, linearity, accuracy and precision, limit of quantification, recovery and matrix effects, sample stability, and carryover. The six-point calibration curves showed linearity over the range of concentrations from 25 to 500 ng/ml for tamoxifen, 5 to 200 ng/ml for anastrozole, and 10 to 300 ng/ml for letrozole. The intra- and inter-day precision and accuracies were always better than 15%. The validated procedure was successfully applied to a clinical study (Patient-Reported Outcomes in Breast Cancer Patients undergoing Endocrine Therapy, PRO-BETh). A major aim of PRO-BETh study is the comprehensive evaluation of adherence to treatment in pre- and post-menopausal women with breast cancer. Plasma samples of 310 breast cancer patients undergoing anti-estrogen therapy were analyzed. Eight samples did not contain a quantifiable amount of drug, strongly indicating non-adherence of the corresponding patients to adjuvant breast cancer treatment. Furthermore, plasma concentrations at the lower end of the observed plasma level distribution might represent a hint but not a confirmation for non-adherence in terms of non-daily and irregular intake of the prescribed drug.  相似文献   

5.
Remdesivir (RDV), a phosphoramidate prodrug, has broad-spectrum antiviral activity. It is the first antiviral drug approved by the US Food and Drug Administration (FDA) for the treatment of COVID-19. Remdesivir is rapidly metabolized in the body to produce derivatives: alanine metabolite (RM-442) and RDV C-nucleoside (RN). Here, the phosphatase inhibitor PhosSTOP and carboxylesterase inhibitor 5,5′-dithiobis-2-nitrobenzoic acid were used to improve stability of RDV in mouse blood. We developed a rapid and sensitive LC–MS/MS method to simultaneously quantify RDV, RM-442 and RN in mouse blood. Chromatographic separation was achieved by gradient elution on an Acquity HSS T3 column. The run time was 3.2 min. The linearity ranges of the analytes were 0.5–1,000 ng/ml for RDV and 5–10,000 ng/ml for both RM-442 and RN. The method had an acceptable precision (RSD < 8.4% for RDV, RSD < 10.7% for RM-442 and RSD < 7.2% for RN) and accuracy (91.0–106.3% for RDV, 92.5–98.6% for RM-442 and 87.5–98.4% for RN). This method was successfully applied to analyze RDV, RM-442 and RN in the blood of normal and diabetic nephropathy DBA/2 J mice after intravenous injection of RDV at 20 mg/kg. The area under the concentration–time curve of RN between the normal and diabetic nephropathy mice showed a significant difference (P < 0.01).  相似文献   

6.
An analytical method was developed using ultra-high-pressure liquid chromatography–triple quadrupole-tandem mass spectrometry (UHPLC–TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in 6 min. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryover was observed even after high analyte concentrations. The instrumental detection limit based on signal-to-noise ratio (S/N) > 3, was below 1 pg/μL (5 pg on column) for all SAs except sulfachloropyridazine. Surface water, ground water, soil, and slurry manure contained in storage ponds in and around swine [Sus scrofa domesticus] rearing facilities were analyzed. Sample cleanup for ground water and surface water included using solid phase extraction (SPE) using Oasis® hydrophilic–lipophilic balance (HLB) cartridges. The soil and slurry manure required tandem strong anion exchange (SAX) and HLB solid phase extraction cartridges for sample cleanup. With few exceptions, the recoveries ranged from 60 to 100% for all matrices. The minimum detectable levels were below 2.0 ng/L for water, 30 ng/L for slurry manure, and 45 ng/kg for soil except for sulfachloropyridazine. The coefficient of variation (CV) was within 20% for most of the compounds analyzed. Using this method, sulfamethazine concentrations of 2250–5060 ng/L, sulfamethoxazole concentrations of 108–1.47 × 106 ng/L, and sulfathiazole concentrations of 785–1700 ng/L were found in the slurry manure. Sulfadimethoxine (2.0–32 ng/L), sulfamethazine (2.0–5.1 ng/L), and sulfamethoxazole (20.5–43.0 ng/L) were found in surface water and ground water. In top soil (0–15 cm), sulfamethazine ranged 34.5–663 ng/kg dry weight in those locations that received slurry manure as a nutrient; no SAs were found in the soil depths between 46 and 61 cm. The speed makes the method practical for medium to high throughput applications. The sensitivity and positive analyte identification make the method suitable for the demanding requirements for real world applications.  相似文献   

7.
We report on the first label-free electrochemiluminescence (ECL) immunosensor for α-fetoprotein (AFP). It is based on the use of CdSe quantum dots that were electrodeposited directly on a gold electrode from an electrolyte (containing cadmium sulfate, EDTA and selenium dioxide) by cycling the potential between 0 and -1.2?V (vs. SCE) for 60?s. The electrodeposited dots were characterized by scanning electron microscopy and energy dispersive spectroscopy. Under optimal conditions, the specific immunoreaction between AFP and anti-AFP resulted in a decrease of the ECL signal because of the steric hindrance and the transfer inhibition by peroxodisulfate. The quenching effect of the immunoreaction on the intensity of the ECL was used to establish a calibration plot which is linear in the range from 0.05 to 200?ng?mL?1. The detection limit is 2?pg?mL?1. The assay is highly sensitive and satisfactorily reproducible. In our opinion it opens new avenues to apply ECL in label-free biological assays.
Figure
We report on the first label-free electrochemiluminescence (ECL) immunosensor for α-fetoprotein (AFP). It is based on the use of CdSe quantum dots that were electrodeposited directly on a gold electrode from an electrolyte. Under optimal conditions, the specific immunoreaction between AFP and anti-AFP resulted in a decrease of the ECL signal because of the steric hindrance and the transfer inhibition by peroxodisulfate  相似文献   

8.
Structure–activity relationship (SAR) models are recognized as powerful tools to predict the toxicologic potential of new or untested chemicals and also provide insight into possible mechanisms of toxicity. Models have been based on physicochemical attributes and structural features of chemicals. We describe herein the development of a new SAR modeling algorithm called cat-SAR that is capable of analyzing and predicting chemical activity from divergent biological response data. The cat-SAR program develops chemical fragment-based SAR models from categorical biological response data (e.g. toxicologically active and inactive compounds). The database selected for model development was a published set of chemicals documented to cause respiratory hypersensitivity in humans. Two models were generated that differed only in that one model included explicate hydrogen containing fragments. The predictive abilities of the models were tested using leave-one-out cross-validation tests. One model had a sensitivity of 0.94 and specificity of 0.87 yielding an overall correct prediction of 91%. The second model had a sensitivity of 0.89, specificity of 0.95 and overall correct prediction of 92%. The demonstrated predictive capabilities of the cat-SAR approach, together with its modeling flexibility and design transparency, suggest the potential for its widespread applicability to toxicity prediction and for deriving mechanistic insight into toxicologic effects.  相似文献   

9.
A new method has been developed to analyze current–potential curves. The treatment was applied to determine the kinetic parameters of oxygen reduction. The reduction of oxygen was studied on thin-film platinum electrodes in alkaline solution. For the purpose of comparison the kinetic parameters were determined by the traditional method of constructing Tafel plots.  相似文献   

10.
Amlexanox, an anti-inflammatory and anti-allergic agent, has been widely used clinically for the treatment of canker sores, asthma, and allergic rhinitis. Recently, amlexanox has received considerable attention in curing nonalcoholic fatty liver diseases and hepatitis virus infection. Herein, we first established a sensitive high-performance liquid chromatography-tandem mass spectrum (LC–MS/MS) method for the determination of amlexanox in rat plasma. Propranolol was used as the internal standard (IS). Using a simple protein precipitation method, the amlexanox and IS were separated with Capcell Pak C18 column (2.0 × 50 mm, 5 μm) and eluted with water and acetonitrile each containing 0.1% formic acid using gradient elution condition at a flow rate of 0.4 mL·min−1. Amlexanox and IS were detected by a triple quadrupole mass in multiple reactive monitoring (MRM) under the transitions of m/z 299.2 → 281.2 and m/z 259.9 → 116.1 with positive electrospray ionization, respectively. The calibration curves of amlexanox were established with the range of 50 to 2000 ng·mL−1 (r2 > 0.99). The validation method consisted of selectivity, accuracy, precision, carryover effect, matrix effect, recovery, dilution effect, and stability. The fully validated method was successfully applied to the pharmacokinetic study of amlexanox in Wistar rats.  相似文献   

11.
A new sorbent, thorium oxalate incorporated in silica gel matrix was prepared. This material was characterized by X-ray, Thermo-gravimetric Analysis, surface area and porosity analysis. The material was obtained in the form of granular particles in the mesh size range of 80–150 American Standard of Testing Materials, yielding good liquid flow, when packed in ion exchange column. This sorbent was investigated for the sorption of americium from various aqueous media such as nitric acid, oxalic acid and sulphuric acid by distribution coefficient studies. Column experiments were carried out to study the practical application of this sorbent for removal of americium from oxalic acid-nitric acid solutions. Elution studies were also carried out for the recovery of americium.  相似文献   

12.
Furosemide is a diuretic drug used to increase urine flow in order to reduce the amount of salt and water in the body. It is commonly utilized to treat preterm infants with chronic lung disease of prematurity. There is a need for a simple and reliable quantitation of furosemide in human urine. We have developed and validated an ultra-high performance liquid chromatography–tandem mass spectrometry method for furosemide quantitation in human urine with an assay range of 0.100–50.0 μg/ml. Sample preparation involved solid-phase extraction with 10 μl of urine. Intra-day accuracies and precisions for the quality control samples were 94.5–106 and 1.86–10.2%, respectively, while inter-day accuracies and precision were 99.2–102 and 3.38–7.41%, respectively. Recovery for furosemide had an average of 23.8%, with an average matrix effect of 101%. Furosemide was stable in human urine under the assay conditions. Stability for furosemide was shown at 1 week (room temperature, 4, −20 and −78°C), 6 months (−78°C), and through three freeze–thaw cycles. This robust assay demonstrates accurate and precise quantitation of furosemide in a small volume (10 μl) of human urine. It is currently being implemented in an ongoing pediatric clinical study.  相似文献   

13.
Recent studies have revealed that the combination therapy of atorvastatin (ATV) with naringenin (NG) can offer meaningful benefits in the treatment of hypercholesterolemia, while decreasing adverse side effects. To investigate whether there are pharmacokinetic interactions among ATV, its metabolite 2-hydroxy atorvastatin (2-ATV), and NG, in the current study, we developed and validated a simple, rapid, and specific UPLC–MS/MS method to simultaneously determine the concentrations of these analytes in the rat plasma. Sample preparation was performed using simple protein precipitation. Chromatographic analysis was carried out on an Acquity UPLC BEH C18 column (1.7 μm, 2.1 × 100 mm) using gradient elution mode, and these three analytes were detected using a Xevo® TQD triple quadrupole tandem mass spectrometer, in the positive ion electrospray ionization interface. The developed method showed good linearity over the following concentrations in rat plasma samples: 3–1200 ng/ml (r = 0.9965) for ATV, 1.5–600 ng/ml (r = 0.9934) for 2-ATV, and 3–1200 ng/ml (r = 0.9964) for NG. The assays were validated and satisfied the acceptance criteria recommended by U.S. Food and Drug Administration guidelines. Upon successful application of the method to a pharmacokinetic interaction study, the results indicated that NG significantly enhanced the bioavailability of ATV and 2-ATV.  相似文献   

14.
In (I), we describe a numerical method for determining the relaxation distribution function from decay curves. The distribution function is expanded in a series of appropriate polynomials and the best values of the coefficients are determined by the method of least squares. In order to examine its applicability and limit, we apply it to some artificial decay curves constructed with different types of distribution functions. According to the results, our method is more adequate for the continuous distribution than for the discrete one. Accurate calculation is very effective so long as the original decay data are accurate, while rough calculation is good when the original decay data are rough or include some noise. Therefore, rough calculation is practical for analysis of experimental decay data which are not free from errors.In (II), we apply our method to the decay process of electric birefringence of several concentrated poly-γ-benzyl-L-glutamate solutions. It is sometimes necessary to modify the experimental data because of improper selection of the base line. The semi-logarithmic plot is effective for modification. In order to make our physical image clearer, the length distribution function is introduced. Field strength dependence, time dependence and concentration dependence of the length distribution curve have been obtained. Our method is powerful for investigating a systematic change of the distribution function with changes of external or internal conditions.  相似文献   

15.
Hydride generation (HG) coupled with AAS, ICP–AES, and AFS techniques for the speciation analysis of As, Sb, Se, and Te in environmental water samples is reviewed. Careful control of experimental conditions, offline/online sample pretreatment methods employing batch, continuous and flow-injection techniques, and cryogenic trapping of hydrides enable the determination of various species of hydride-forming elements without the use of chromatographic separation. Other non-chromatographic approaches include solvent extraction, ion exchange, and selective retention by microorganisms. Sample pretreatment, pH dependency of HG, and control of NaBH4/HCl concentration facilitate the determination of As(III), As(V), monomethylarsonate (MMA), and dimethylarsinate (DMA) species. Inorganic species of arsenic are dominant in terrestrial waters, whereas inorganic and methylated species are reported in seawater. Selenium and tellurium speciation analysis is based on the hydrides generation only from the tetravalent state. Se(IV) and Se(VI) are the inorganic selenium species mostly reported in environmental samples, whereas speciation of tellurium is rarely reported. Antimony speciation analysis is based on the slow kinetics of hydride formation from the pentavalent state and is mainly reported in seawater samples.  相似文献   

16.
Polyphyllin II, a major steroidal saponin isolated from Paris polyphylla, exhibits significant pharmacological activities. In this study, a rapid and sensitive liquid chromatography–tandem mass spectrometry method was established and validated for the determination of polyphyllin II in plasma. Polyphyllin II and polyphyllin VII (internal standard) were separated on a Waters Acquity™ HSS T3 column and the mass analysis was performed in a triple quadrupole mass spectrometer equipped with an electrospray ionization ion source. Results showed that the method was sensitive (lower limit of quantitation 0.5 ng/ml), precise (<15%) and linear in the range of 0.5–500 ng/ml (r > 0.99). Interestingly, the sensitivity in current study was ~10 times higher than that in the previous study. The results of the pharmacokinetic study of polyphyllin II in rats suggested that polyphyllin II was poorly absorbed into blood and reached its highest concentration at ~3.67–5.00 h with a slow elimination half-life of 8.34–13.37 h. The bioavailability was 6.1–8.2%. The results indicated that the absorption of polyphyllin II may primarily occur via passive diffusion in rats. This study provides valuable information that can be used as a reference for the pharmacokinetic investigation of other steroidal saponins.  相似文献   

17.
The quasirelativistic (QR) generalized unrestricted Hartree-Fock method for the magnetic shielding constant [R. Fukuda, M. Hada, and H. Nakatsuji, J. Chem. Phys. 118, 1015 (2003); R. Fukuda, M. Hada, and H. Nakatsuji, J. Chem. Phys.118, 1027 (2003)] has been extended to include the electron correlation effect in the level of the second-order M?ller-Plesset perturbation theory (MP2). We have implemented the energy gradient and finite-perturbation methods to calculate the magnetic shielding constant at the QR MP2 level and applied to the magnetic shielding constants and the NMR chemical shifts of 125Te nucleus in various tellurium compounds. The calculated magnetic shielding constants and NMR chemical shifts well reproduced the experimental values. The relations of the chemical shifts with the natures of ligands, and the tellurium oxidation states were investigated. The chemical shifts in different valence states were explained by the paramagnetic shielding and spin-orbit terms. The tellurium 5p electrons are the dominant origin of the chemical shifts in the Te I and Te II compounds and the chemical shifts were explained by the p-hole mechanism. The tellurium d electrons also play an important role in the chemical shifts of the hypervalent compounds.  相似文献   

18.
19.
In this research, we developed and validated a liquid chromatography coupled to mass spectrometry (LC–QToF–MS) method for simultaneous quantification of the anti-tuberculosis drugs ethambutol, isoniazid, pyrazinamide and rifampicin in human plasma. Plasma samples spiked with cimetidine (internal standard) were extracted using protein precipitation with acetonitrile containing 1% formic acid. Separation was performed using a C18 column under flow gradient conditions with water and acetonitrile, both containing 5 mm ammonium formate and 0.1% formic acid. The method was validated according to the ANVISA and US Food and Drug Administration guidelines for bioanalytical method validation. The calibration curve was linear over a concentration range of 0.2–5 μg ml−1 for ethambutol, 0.2–7.5 μg ml−1 for isoniazid, 1–40 μg ml−1 for pyrazinamide and 0.25–2 μg ml−1 for rifampicin, all with adequate precision and accuracy. The method was reproducible, selective and free of carryover and matrix effects. The validated LC–QToF–MS method was successfully applied to real samples and shown to be applicable to future therapeutic and pharmacokinetic monitoring studies.  相似文献   

20.
We developed an ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method to determine four antibacterial drugs in human plasma for clinical usage. Samples were prepared using protein precipitation with methanol. Chromatographic separation was accomplished in 4.5 min on a BEH C18 column (2.1 × 50 mm, 1.7 μm) using a gradient elution of methanol and water (containing 7.71 g/L concentrated ammonium acetate, adjusted to pH 6.5 with acetic acid) at a flow rate of 0.4 mL/min. Positive electrospray was used for ionization. The method was linear in the concentration range 1–100 μg/mL for vancomycin, norvoncomycin, and meropenem; and 0.5–50 μg/mL for R-isomer of moxalactam and S-isomer of moxalactam. For all analytes, the intra- and inter-day accuracies and precisions were −8.47%–10.13% and less than 12%, respectively. The internal standard normalized recoveries and matrix effect were 62.72%–105.78% and 96.67%–114.20%, respectively. All analytes were stable at six storage conditions, with variations of less than 15.0%. The method was applied in three patients with central nervous system infection. The validated method might be useful for routine therapeutic drug monitoring and pharmacokinetic study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号