首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We have developed a method using on-line solid-phase extraction–high-performance liquid chromatography–tandem mass spectrometry (SPE-HPLC-MS/MS) and isotope dilution quantification to measure atrazine and seven atrazine metabolites in urine. The metabolites measured were hydroxyatrazine, diaminochloroatrazine, desisopropylatrazine, desethylatrazine, desethylatrazine mercapturate, atrazine mercaturate and atrazine itself. Our method has good precision (relative standard deviations ranging from 4 to 20% at 5, 10 and 50 ng/mL), extraction efficiencies of 67 to 102% at 5 and 25 ng/mL, relative recoveries of 87 to 112% at 5, 25, 50 and 100 ng/mL limits of detection (LOD) ranging from 0.03 to 2.80 ng/mL. The linear range of our method spans from the analyte LOD to 100 ng/mL (40 ng/mL for atrazine and atrazine mercapturate) with R 2 values of greater than 0.999 and errors about the slope of less than 3%. Our method is rapid, cost-effective and suitable for large-scale sample analyses and is easily adaptable to other biological matrices. More importantly, this method will allow us to better assess human exposure to atrazine-related chemicals. Figure A schematic representation showing the elution of the analytes from the solid-phase extraction cartridge onto the analytical column for chromatographic separation prior to MS/MS analysis  相似文献   

2.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed for the simultaneous screening of 19 drugs of different classes in equine plasma using automated on-line solid-phase extraction (SPE) coupled with a triple quadrupole mass spectrometer. Plasma samples were first protein precipitated using acetonitrile. After centrifugation, the supernatant was directly injected into the on-line SPE system and analysed by a triple quadrupole LC–MS–MS in positive electrospray ionisation (+ESI) mode with selected reaction monitoring (SRM) scan function. On-line extraction and chromatographic separation of the targeted drugs were performed using respectively a polymeric extraction column (2 cm L × 2.1 mm ID, 25 μm particle size) and a reversed-phase C18 LC column (3 cm L × 2.1 mm ID, 3 μm particle size) with gradient elution to provide fast analysis time. The overall instrument turnaround time was 9.5 min, inclusive of post-run and equilibration time. Plasma samples fortified with 19 targeted drugs including narcotic analgesics, local anaesthetics, antipsychotics, bronchodilators, mucolytics, corticosteroids, sedative and tranquillisers at sub-parts per billion (ppb) to low parts per trillion (ppt) levels could be consistently detected. No significant matrix interference was observed at the expected retention times of the targeted ion transitions. Over 70% of the drugs studied gave detection limits at or below 100 pg/mL, with some detection limits reaching down to 19 pg/mL. The method had been validated for extraction recovery, precision and sensitivity, and a blockage study had also been carried out. This method is used regularly in the authors’ laboratory to screen for the presence of targeted drugs in pre-race plasma samples from racehorses.  相似文献   

3.
A validated method based on solid-phase extraction (SPE) and liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) is described for the determination of cocaine (COC) and its principal metabolites, benzoylecgonine (BE) and ecgonine methyl ester (EME), in waste and surface water. Several SPE adsorbents were investigated and the highest recoveries (95.7 +/- 5.5, 91.8 +/- 2.2 and 72.5 +/- 5.3% for COC, BE and EME, respectively) were obtained for OASIS HLB(R) cartridges (6 mL/500 mg) using 100 mL of waste water or 500 mL of surface water. Extracts were analysed by reversed-phase (RP) or hydrophilic interaction (HILIC) LC-MS/MS in positive ion mode with multiple reactions monitoring (MRM); the latter is the first reported application of the HILIC technique for drugs of abuse in water samples. Corresponding deuterated internal standards were used for quantification. The method limits of quantification (LOQs) for COC and BE were 4 and 2 ng L(-1), respectively, when RPLC was used and 1, 0.5 and 20 ng L(-1) for COC, BE and EME, respectively, with the HILIC setup. For COC and BE, the LOQs were below the concentrations measured in real water samples. Stability tests were conducted to establish the optimal conditions for sample storage (pH, temperature and time). The degradation of COC was minimal at -20 degrees C and pH = 2, but it was substantial at +20 degrees C and pH = 6. The validated method was applied to a set of waste and surface water samples collected in Belgium.  相似文献   

4.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

5.
A solid-phase extraction (SPE) LC–MS/MS method for 18 commercial drugs in secondary wastewater and product water from water recycling plants using microfiltration (MF) and reverse osmosis (RO) has been developed, optimised and validated. The method incorporates a range of multi-class pharmaceuticals including lipid lowering agents, analgesics, antipyretics, non-steroidal anti-inflammatory drugs, antidepressants, anticoagulants, tranquilizers, cytostatic agents, and antiepileptics. Method limits of quantitation (MLQs) in secondary wastewater ranged from 15 to 250 ng/L, while MLQs in post-RO water ranged from 1 to 25 ng/L. Results from analysis of secondary wastewater from Western Australia are presented, and represent the largest survey of non-antibiotic pharmaceuticals within Australia to date. Analysis of post-RO water from two MF/RO water recycling facilities also demonstrate that MF/RO treatment removes most pharmaceuticals to below the analytical limits of detection, and more importantly, up to seven orders of magnitude below health-based guideline values.  相似文献   

6.
7.
An optimised and validated method for the determination of pharmaceutical residues in blue mussels (Mytilus spp.) is presented herein, as well as an investigation of the effect of cooking (by steaming) on any potential difference in human exposure risk. Selected pharmaceuticals included two non-steroidal anti-inflammatory drugs (diclofenac and mefenamic acid), an antibiotic (trimethoprim), an anti-epileptic (carbamazepine) and a lipid regulator (gemfibrozil). An in vivo exposure experiment was set up in the laboratory in which mussels were exposed either directly by injection (10 ng) or daily through spiked artificial seawater (ASW) over 96 h. In liquid matrices, pharmaceutical residues were either determined using liquid chromatography–tandem mass spectrometry (LC-MS/MS) directly, or in combination with solid-phase extraction (SPE) for analyte concentration purposes. The extraction of pharmaceuticals from mussel tissues used an additional pressurised liquid extraction step prior to SPE and LC-MS/MS. Limits of quantification of between 2 and 46 ng L?1 were achieved for extracted cooking water and ASW, between 2 and 64 μg L?1 for ASW in exposure tanks, and between 4 and 29 ng g?1 for mussel tissue. Method linearities were achieved for pharmaceuticals in each matrix with correlation coefficients of R 2?>?0.975. A selection of exposed mussels was also cooked (via steaming) and analysed using the optimised method to observe any effect on detectable concentrations of parent pharmaceuticals present. An overall increase in pharmaceutical residues in the contaminated mussel tissue and cooking water was observed after cooking.
Figure
Pharmaceutical residues in cooked and uncooked marine bivalves  相似文献   

8.
A rapid, sensitive, and environmental-friendly multi-residue method has been developed for the simultaneous determination of seven neonicotinoid insecticides (dinotefuran, nitenpyram, thiamethoxam, imidacloprid, clothianidin, acetamiprid, and thiacloprid) residues in eel samples. Subcritical water extraction was investigated as a novel and alternative technology for the extraction of neonicotinoids from eel matrices and the results were compared with the conventional ultrasonic and shaking extraction. The target compounds were identified and quantitatively determined by ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC–MS/MS) operated in multiple reaction monitoring mode. Under the current optimized chromatographic conditions, each LC run was completed in 5 min. Average recoveries of the seven analytes from fortified samples ranged between 84.6% and 102.0%, with relative standard deviations (RSD) lower than 10.8%. The limits of detection (LODs) and quantification (LOQs) for neonicotinoids were in the ranges of 0.12–0.36 μg kg−1 and 0.42–1.12 μg kg−1, respectively. The proposed method is fast, sensitive, easy to perform, water-based thus more environmentally acceptable, making it applicable for high-throughput monitoring of insecticides residues in aquatic products.  相似文献   

9.
This study describes a procedure for determining eight benzophenone-derived compounds in surface waters and sediments. These include the pharmaceutical ketoprofen, its phototransformation products 3-ethylbenzophenone and 3-acetylbenzophenone, and five benzophenone-type ultraviolet (UV) filters. The proposed analytical method involves the pre-concentration of water samples by solid-phase extraction (SPE) and microwave-assisted extraction (MAE) of sediment samples followed by derivatization and analysis by gas chromatography–mass spectrometry. Different parameters were investigated to achieve optimal method performance. Recoveries of 91 to 96 % from water samples were obtained using HLB Oasis SPE cartridges, whereas MAE of sediments (30 min at 150 °C) gave recoveries of 80 to 99 %. Limits of detection were between 0.1 and 1.9 ng L?1 for water samples and from 0.1 to 1.4 ng g?1 for sediment samples. The developed method was applied to environmental samples and revealed the presence of UV filters in the majority of the surface waters with up to 690 ng L?1 of 2-hydroxy-4-methoxybenzophenone. By contrast, ketoprofen (≤2,900 ng L?1) and its degradation products (≤320 ng L?1) were found in only two rivers, both receiving wastewater treatment plant effluents. Sediment analysis revealed benzophenone to be present in concentrations up to 650 ng g?1, whereas concentrations of other compounds were considerably lower (≤32 ng L?1). For the first time, quantifiable amounts of two ketoprofen transformation products in the aqueous environment are reported.  相似文献   

10.
Non-steroidal anti-inflammatory drugs are widely used for treatment of animals. According to Council Directive 96/23/EC, residues of these drugs must be monitored because of the potential risk they pose to the consumers' health. For this reason an LC-MS-MS method was developed for detection of wide range of NSAIDs, including both "acidic" NSAIDs (carprofen, diclofenac, flunixin, meloxicam, phenylbutazone, oxyphenbutazone, tolfenamic acid, mefenamic acid, naproxen, ketoprofen, ibuprofen, firocoxib, rofecoxib, and celecoxib) and "basic" NSAIDs (four metamizole metabolites). Analytes were extracted from milk samples with acetonitrile in the presence of ammonium acetate. One portion of the extract was directly analyzed for the presence of metamizole metabolites; a second portion was cleaned with an amino cartridge. All NSAIDs were separated on a Phenomenex Luna C8(2) column and analyzed by LC-MS-MS in negative (acidic NSAIDs) and positive (metamizole metabolites) ion modes. The method was validated in accordance with the requirements of Commission Decision 2002/657/EC. Within-laboratory reproducibility was in the range 7-28%, and accuracy was in the range 71-116%. The method enabled detection of all the analytes with the expected sensitivity, below the recommended concentrations. The method fulfills the criteria for confirmatory methods and, because of its efficiency, may also be used for screening purposes. The procedure was also successfully verified in the proficiency test organized by EU-RL in 2010. As far as the authors are aware, this is one of the first methods capable of detecting diclofenac residues below the MRL in milk (0.1 μg kg(-1)). An additional advantage is the possibility of simultaneous determination of "acidic" NSAIDs and metamizole metabolites.  相似文献   

11.
A direct aqueous SFE system designed to extract water samples contained in vials has been coupled on-line with a reverse phase LC–MS–MS system using a single 10-port valve. An SFE trap system using C1 stationary phase connected to a C18 analytical HPLC column enabled the SFE–LC–MS–MS analysis of three polyether ionophore antibiotics in water using a step gradient. A quantitative SFE–LC–MS–MS method has been developed whereby the progress of SFE can be monitored directly on-line such that ionophore recovery profile data from a single water sample can be obtained. Using a continuous direct aqueous SFE period of 75 min, the SFE–LC–MS–MS recoveries of the ionophores were: monensin 76.2% with RSD 4.1%, lasalocid 84.6% with RSD 3.8% and narasin 91.2% with RSD 3.2%. With positive ion electrospray ionization, the SFE–LC–MS–MS system using a 4 mL water sample provided multiple reaction monitoring (MRM) limits of detection for monensin and lasalocid each equivalent to 90 ng/L whereas 30 ng/L for narasin. A two-way valve controlling carbon dioxide distribution to the SFE vessel has provided a means for the initial investigation of the recovery of ionophore sodium salts from water using static SFE.  相似文献   

12.
In this work,a reliable and sensitive method for detecting polybrominated diphenyl ethers(PBDEs) has been developed by the combination of liquid–liquid extraction and gas chromatography–mass spectrometry.PBDEs were extracted from a large volume of water by liquid–liquid extraction and purified by silica gel chromatography.In order to reduce the deviation,dibromobiphenyl was exploited as the internal standard to minimize differences among the injections.The quantification was performed using an external standard.Good linear correlation coefficients(0.991) and a wide linearity range(1.0–500.0 ng/L) indicated the steadiness of the proposed method.Moreover,the satisfactory recovery(75%)suggested that successful determination of PBDEs in river water had been achieved.Furthermore,the deduction behavior of PBDEs in river water could be inferred according to the results.  相似文献   

13.
14.
A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17β-estradiol, 17α-ethynylestradiol, estriol) and eleven progestogens (17β-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) with electrospray ionization. Among three types of extraction tested (C8 SPDE, C18 SPDE and C18 SPE), the most satisfactory result was achieved using C18 SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1 L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5–3.4 ng/L) and excellent linear dynamic range (1.0–50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17α-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.  相似文献   

15.
The development and performance evaluation of an analytical method dedicated to the comprehensive determination of the most relevant antioxidants and their metabolites in aqueous environmental samples is presented. This was achieved by a miniaturised solid-phase extraction (SPE) with 10 mg Oasis HLB cartridges, which allow to achieve a concentration factor of 200, reducing organic solvent wastes (1 mL of ethyl acetate suffices for complete elution) and SPE costs and eliminating the need for solvent evaporation that otherwise compromises the recoveries of butylated hydroxytoluene (BHT) and 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q). Analytes were then determined by gas chromatography–mass spectrometry (GC–MS) after derivatisation with N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA) in a single run. BHT-d7 and n-propyl-paraben-d4 (PrP-d4) were used as surrogate internal standards. These surrogates allowed obtaining relative recoveries in the 80–110% range for all analytes even with complex wastewater samples and LODs at the 2–44 ng L−1 level taking into account blank issues often associated to antioxidants analysis. The method was applied to sewage and river waters, showing that the seven analytes could be detected in raw wastewater. BHT and BHT-Q were the most concentrated species in that type of sample (in the 275–871 ng L−1 range). On the other hand two metabolites of BHT, 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO) and 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) appeared to be the most ubiquitous species, being found in all samples in the 10–150 ng L−1 concentration range.  相似文献   

16.
Stir-bar-sorptive extraction (SBSE) with liquid desorption (LD) and ultra-high-performance liquid chromatography–electrospray ionization triple-quadrupole tandem mass spectrometry (UHPLC–(ESI)MS–MS) were used for analysis of six personal care products in environmental water: four UV filters (2,2-dihydroxy-4-methoxybenzophenone, benzophenone-3, octocrylene, and octyldimethyl-p-aminobenzoic acid) and two antimicrobial agents (triclocarban and triclosan). Experimental conditions that affect SBSE-LD sorption efficiency (extraction time and temperature, sample pH, and ionic strength) and desorption efficiency (solvent, temperature, and time) were optimized. The method proved to be sensitive—a 50-mL sample was used to determine these compounds in environmental waters at trace levels. The detection limits of the analytical method were 2.5 ng L−1 for river water and 5–10 ng L−1 for effluent and influent sewage water. In river waters, benzophenone-3 was found at levels from 6 ng L−1 to 28 ng L−1 and triclosan at levels <LOQ. Benzophenone-3 was found between 75 and 127 ng L−1 in influent sewage, whereas concentrations of benzophenone-3 and triclosan were commonly below 25 ng L−1 in effluent sewage.  相似文献   

17.
A simple, fast and sensitive liquid chromatography–electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding l-ascorbic acid, and directly injected after filtered by 0.22 μm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 μg/L except for chlorodibromoacetic acid (1.44 μg/L) and tribromoacetic acid (8.87 μg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1–108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79–36.5 μg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO.  相似文献   

18.
An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography–tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm?×?2.1 mm, 1.7 μm Acquity UPLC CSH C18 column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.
Figure
Robotic setup for fully automated solid-phase extraction of whole blood  相似文献   

19.
This study used reversed-phase liquid chromatography–tandem mass spectrometry and supercritical fluid chromatography–tandem mass spectrometry for determination of the stereoisomers of chlorfenvinphos and dimethylvinphos in tobacco. Tobacco samples were extracted and purified with a modified quick, easy, cheap, effective, rugged, and safe technique using spherical carbon. The performance of both methodologies was comprehensively compared in terms of methods validation parameters (separation efficiency, linearity, selectivity, recovery, repeatability, sensitivity, matrix effect, etc.). Under optimized conditions, the calibration curves of the stereoisomers of chlorfenvinphos and dimethylvinphos in the range of 10–500 ng/mL showed excellent linearity with R2 ≥ 0.997 in both methods. The adequate recoveries of analytes from three different spiked tobaccos were obtained using reversed-phase liquid chromatography–tandem mass spectrometry (86.1–95.7%) as well as supercritical fluid chromatography–tandem mass spectrometry (86.5–94.0%). The relative standard deviations for spiked samples were all below 7.0%. Compared with supercritical fluid chromatography–tandem mass spectrometry, lower matrix effects and LODs can be obtained in reversed-phase liquid chromatography–tandem mass spectrometry.  相似文献   

20.
Surfactants and their metabolites can be found in aquatic environments at relatively high concentrations compared with other micropollutants due in part to the exceptionally large volumes produced every year. We have focused our attention here on the most widely used nonionic surfactants, alcohol ethoxylates (AEOs), and on nonylphenol ethoxylate (NPEO) degradation products (short-chain nonylphenol ethoxylates, NP1-3EO, nonylphenol, NP, and nonylphenol ethoxycarboxylates, NP1-2EC), which are endocrine-disrupting compounds. Our main objective in this work was to develop a methodology aimed at the extraction, isolation, and improved analysis of these analytes in environmental samples at trace levels. Extraction recoveries of target compounds were determined for sediment samples after ultrasonic extraction and purification using HLB or C18 solid-phase extraction minicolumns. Recovery percentages were usually between 61 and 102% but were lower for longer AEO ethoxymers. Identification and quantification of target compounds was carried out using a novel ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS-MS) approach, a combination that provides higher sensitivity and faster analysis than prior methods using conventional high-performance liquid chromatography–mass spectrometry. Limits of detection were usually below 0.5 ng/g, being higher for monoethoxylate species (>5 ng/g) because of poor ionization. The method was used for analyzing surface sediment samples collected at Jamaica Bay (NY) in 2008. The highest values (28,500 ng/g for NP, 4,200 ng/g for NP1-3EO, 22,400 ng/g for NP1-2EC, and 1,500 ng/g for AEOs) were found in a sampling station from a restricted water circulation area that is heavily impacted by wastewater discharges.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号