共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary We have investigated to which extent retention data, acquired on single capillary columns, can be used for predicting retention factors in a coupled column system. For this purpose we utilized a model mixture of 18 lipid components with widely different vapor pressures and polarities. The sample was chromatographed on two columns, SB-biphenyl-30 (70% methyl-30% biphenylpolysiloxane) and SB-cyanopropyl-50 (50% methyl-50% cyanopropylsiloxane). Experimental retention factors, acquired in coupled column systems with two columns connected in different order, were thus compared with values calculated from runs on each single column. The agreement between calculated and experimental values generally was better than 5% without any pressure drop correction.To study the possibility of predicting retention behavior in a wide pressure range from a limited number of experiments, we also investigated the relation between solute retention and mobile phase density. We found that all data could be fitted to second order equations, which gives the possibility to optimize the resolution with respect to pressure from a limited number of runs at different pressures. 相似文献
2.
Mark W. Raynor Sianne L. Roberts Dulcie A. Mulholland 《Journal of separation science》1993,16(8):469-472
Capillary supercritical fluid chromatography (SFC) with carbon dioxide as the mobile phase has been used to separate a mixture of limonoid standards. Chromatographic conditions were optimized to enable analysis of plant extracts. The seed of Aphanamixis polystacha (Meliaceae) and the stem bark of Harpephyllum caffrum (Anacardiaceae) were extracted with hexane and the extracts were analyzed by SFC to demonstrate the potential of the technique as a screening tool. SFC analysis indicated the presence of limonoids in the hexane extract of the bark of Entandrophragma delevoyii (Meliaceae). One limonoid and two protolimonoids isolated from the extract were separated by SFC. 相似文献
3.
Summary This paper reports the qualitative and quantitative effects of the column pressure drop on the retention of lipid components in a serially coupled capillary column SFC system. The contribution of the pressure drop consists of two components, the density effect and the flow effect. The magnitude of the flow effect,i. e. the change in retention which results from changes in the flow-rate when column pressures are changed, is determined by the difference in single column analyte k values. The effect will be positive compared with the uncorrected retention values when the column with largest k value is closest to the injector. With the columns in reversed order, the effect will be negative. The contribution from the density effect always resulted in larger coupled column k values and was in most instances of more significance than the flow effect component. Values calculated with and without pressure drop correction have been compared and it has been shown that for most of the eighteen model lipid compounds investigated, the deviations from the experimental retention factors were smaller when pressure drop corrections were made. 相似文献
4.
B. W. Wright H. T. Kalinoski H. R. Udseth R. D. Smith 《Journal of separation science》1986,9(3):145-153
Capillary supercritical fluid chromatography and its combination with mass spectrometry (SFC-MS) is an important analytical methodology for the analysis of thermally labile and high molecular weight compounds. The mass spectrometer provides sensitive and highly selective detection for the chromatographic effluent. The same physical-chemical properties of supercritical fluids that provide important chromatographic advantages are also important for the transport and gas phase introduction of analyte molecules into the mass spectrometer. The low mobile phase flow rates of small diameter (< 100 μm i.d.) capillary columns allow the total chromatographic effluent to be introduced with conventional, but often slightly modified, ion source configurations for quadrupole mass spectrometers with either electron impact (EI) or chemical ionization (CI) detection. The full range of CI reagents can also be used to obtain additional selectivity and complementary structural data. The instrumentation and operating parameters for capillary SFC-MS methods are described. The applicability and usefulness of various SFC-MS analysis methods are demonstrated using a variety of samples. 相似文献
5.
Supercritical fluid chromatography (SFC) sometimes exhibits GC-like behavior and sometimes LC-like behavior, depending on conditions. However, it is not always clear whether one of these types of behavior, or a combination, operates for a particular set of conditions for every solute in a mixture. For example, some components may be partitioned mostly by their vapor pressures, while others, in the same mixture, are partitioned predominantly by solvent-like properties of the mobile phase. Plots of retetion (as log of the capacity factor) vs. reciprocal temperature at constant pressure reveal a clear change in the character of the separation of well-behaved solutes. A thermodynamic explanation of the observed behavior is given, based on the assumption that partitioning is controlled by the heats of solution of solute in the mobile and stationary phases. A model of SFC retention as it deviates from pure-GC behavior on the same column is presented. 相似文献
6.
In cases where high efficiency is required to resolve complex mixtures of either thermally labile or nonvolatile organic compounds, capillary supercritical fluid chromatography may be the most desirable analytical method. While great strides in this new technology have been made over the last few years, several problem areas are requiring increased attention. These include sample introduction systems, pressure reduction at the end of the column, column stability in various supercritical mobile phases, and migration of polar solute molecules. This paper describes the state-of-the-art in capillary SFC with emphasis on the progress made and future needs in the solutions to these specific problems. 相似文献
7.
New strategies for sample introduction in supercritical fluid chromatography are reviewed. Both open tubular and packed column systems are examined as the injection demands of each column type are addressed. In addition to advances made in solvent injection methods, supercritical fluid extraction (SFE) is discussed as a solventless injection technique for supercritical fluid chromatography. 相似文献
8.
9.
A simple interface between a capillary supercritical fluid chromatograph and an Extranuclear Simulscan mass spectrometer is described. The SFC column is directly inserted into the ion source through the existing GC-interface. The system is equipped with a splitting device which allows simultaneous EI/MS and flame ionization detection when CO2 is used as the supercritical phase. The effect of source temperature and pressure on CO2 clustering was studied for optimization of source conditions. The performance of the system was evaluated with a series of model compounds and standard mixtures. 相似文献
10.
11.
A. Farbrot Buskhe B. E. Berg O. Gyllenhaal T. Greibrokk 《Journal of separation science》1988,11(1):16-20
A splitless injection technique, allowing 0.5 μl injections on 50 μm i.d. columns, has been developed. 相似文献
12.
Summary Seven Kava lactones were extracted from Kava root using both pure and 15% ethanol modified CO2. Most of the Kava lactones were extracted employing 100% CO2 with an efficiency greater than 90% relative to conventional solvent extraction using organic solvents. Extraction efficiency
did not increase significantly when using 15% ethanol-modified CO2 as an extraction fluid. Separation of extracted Kava lactones was obtained using various packed columns and methanol-modified
CO2. An optimized separation was achieved using either an amino or protein C4 column at 125 atm and 80°C. Semi-preparative separation of Kava lactones was also obtained using two columns connected in
series. 相似文献
13.
Summary Peak compression of a dihydropyridine drug, clevidipine, is obtained in both analytical and semi-preparative scale supercritical
fluid chromatography, resulting in extremely high apparent efficiencies. The observed effect, when utilising a carbon dioxide/2-propanol
mobile phase with a bare silica stationary phase, is achieved when the retention of the clevidipine peak is controlled to
coalesce with a system peak, generated as a result of having water in the sample. Apparent efficiencies of 350,000 and 170,000
plates meter−1 were obtained when 0.25 and 0.5 mg, respectively, are directly injected to a 200×4.6 mm ID 5 μm Hypersil silica packed column.
The effect was extended to a semi-preparative system where apparent efficiencies in the region of 2,000,000 plates meter−1 were observed when 0.3 mg of a clevidipine sample containing 80% water was injected to a 250×10 mm I.D. column containing
5-μm Hypersil silica particles. 相似文献
14.
The useful combination of capillary supercritical fluid chromatography with ultraviolet multichannel detection is demonstrated by the analysis of selected pesticides and herbicides. In this application the advantages of compound identification by ultraviolet spectrometry are appended to the separating capability of capillary supercritical fluid chromatography. A pseudo oncolumn detection approach is used. Compromises from the theoretically ideal conditions for both capillary SFC and the multichannel UV detector are made to achieve a practical interfacing of the chromatographic and spectrophotometric techniques. Detection limits are at the low nanogram levels. 相似文献
15.
16.
Analysis of low concentration polymer additives has been a challenging problem. The commonly used methods of analysis involve the initial extraction of polymer additives with solvents, often in a Soxhlet apparatus, followed by liquid, size exclusion, or gas chromatography. This paper describes the on-line super-critical fluid extraction (SFE)-supercritical fluid chromatographic (SFC) determination of different additives from low density polyethylene. Cryogenic collection was used as an interface between SFE and SFC to focus the extraction eluate before transfer to an analytical SFC column for quantitative analysis. 相似文献
17.
A new analytical technique combining on-line supercritical fluid chromatography with capillary gas chromatography has been developed. The supercritical fluid sample effluent is decompressed through a restrictor directly into a conventional capillary gas chromatographic injection port. This technique allows for not only direct (100%) sample transfer from the supercritical fluid chromatograph to the gas chromatograph but also for selective or multi-step heartcutting of various sample peaks as they elute from the supercritical fluid chromatograph. Heartcut times are determined by monitoring the responses from the flame ionization or ultraviolet absorbance detectors on the supercritical fluid chromatograph. This report describes the operational setup and provides the results of heartcut reproducibility experiments using normal hydrocarbon and aromatic test mixtures. Results from studies where operational parameters were varied, such as GC injector temperature, will also be provided. The potential usefulness of this new technique for selective heartcutting will also be demonstrated using complex hydrocarbon streams. 相似文献
18.
Summary A mini extractor of 85 L void volume and a micro extractor of 3–4 L void volume have been coupled directly with a packed column SFC and used under sub- and supercritical conditions. The mini extractor is suitable for holding adsorbates which can be on-line extracted and the extract chromatographed (direct SFE-SFC). The micro extractor can be used for direct sample introduction of liquid and solid materials under SF conditions. Thus any solvent interference with the sample and the chromatographic conditions is excluded. Standard samples of wood tar residue, engine oil, and metal organic compounds have been tested. 相似文献
19.
20.
The characterization and determination of peptides is of great importance in the pharmaceutical industry as is the ability to rapidly perform targeted determinations of bioactive peptides in complex matrices. The purpose of the presented work is to assess the feasibility of packed column supercritical fluid chromatography (SFC) for the separation of two-pairs of water soluble peptides of identical mass, composition and charge that differ only in amino acid sequence. Upon evaluating a variety of conditions, trifluoroacetic acid (HTFA) in conjunction with methanol as the modifier proved to be, in general, the most successful mobile phase additive for elution of the two isomeric peptide pairs from all nitrogenous stationary phases. In contrast, water and ammonium acetate gave distorted peak shapes and therefore proved to be less satisfactory as neutral additives. The basic additive, iso-propylamine (IPAm), coupled with HA-Pyridine yielded the highest resolution factor for the complete study. Aminopropyl and HA-Pyridine columns with 5 μm particle size and 60 Å pore size were found to be best for resolution of each peptide pair. Bare silica and phenyl-hexyl stationary phases did not afford any separation. The primary roles of the carbon dioxide and methanol modifier are believed to provide (a) stationary phase solvation and (b) peptide solubility and transport; while, HTFA is postulated to fully protonate each peptide and form ion pairs between its conjugate base and cationic peptide analyte. The separation process, therefore, is best viewed as ion pair supercritical fluid chromatography (IP-SFC). For the case where IPAm gave good resolution on the HA-Pyridine column, the peptides are probably in the neutral state. 相似文献