首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   

2.
于冰  丛海林  刘虎威  李元宗  刘锋 《色谱》2005,23(5):487-491
采用毛细管电泳技术研究了重组促红细胞生长素(rhEPO)的分离问题。用N,N-二甲基六烷基溴化铵(6,6-ionene)涂层的毛细管测定了rhEPO中唾液酸的微多相性,同时采用毛细管电泳-质谱(CE-MS)联用技术在22 min内鉴定了rhEPO 20段胰酶消化肽中的11段。该方法简单快捷,重现性好,可用于蛋白质一级结构的测定。  相似文献   

3.
Very fast GC analyses are commonly carried out by using 10 m x 0.1 mm id capillaries. In order to achieve rapid elution times (1-3 min), the latter are operated under suboptimum conditions. The present research is focused on the evaluation of use of a 0.1 mm id polar column segment (2 m), operated under near-to-optimum conditions, in very fast GC analysis. The results attained are compared with those derived from using a 10 m microbore column in very fast GC experiments. Prior to method development, the effects of gas velocity, temperature program rate, and sample amounts on analytical performance were evaluated. Following these preliminary applications, a complex lipidic sample, cod liver oil, was subjected to rapid separation (approximately 2.1 min) on the 10 m capillary through the application of a 50 degrees C/min temperature rate and a 130 cm/s gas velocity. The same matrix was analyzed on the 2 m capillary using the same temperature program rate and range, but with a close-to-ideal linear velocity. The results observed were of interest, as the separation was achieved in less time (1.45 min) with improved peak resolution. Finally, both methods were validated in terms of retention time and peak area repeatability, LOQ, and linearity.  相似文献   

4.
A capillary formed by connecting a 9.7 cm‐long separation capillary with id 25 μm with an auxiliary 22.9 cm‐long capillary with id 100 μm (coupled capillary) was tested for electrophoretic separation at high electric field intensities. The coupled capillary was placed in the cassette of a standard electrophoresis apparatus. It was used in the short‐end injection mode for separation of a mixture of dopamine, noradrenaline, and adrenaline in a BGE of 20 mM citric acid/NaOH, pH 3.2. An intensity of 2.7 kV/cm was attained in the separation part of the capillary at a separation voltage of 30 kV, which is 2.9 times more than maximum intensity value attainable in a capillary with the same length with uniform id. At these high electric field intensities, the migration times of the tested neurotransmitters had values of 12.3–13.3 s and the attained separation efficiency was between 2350 and 2760 plates/s. It is thus demonstrated that an effective separation instrument ‐ a coupled capillary ‐ can be used for very rapid separation in combination with standard, commercially available instrumentation.  相似文献   

5.
A combination of a pressure switching system with multiple columns and photoionization detectors makes possible rapid analysis of a mixture of inorganic gases and hydrocarbons. Hydrocarbons are separated by a narrow bore capillary column. An alumina PLOT column is used for the separation of lower molecular weight hydrocarbons, especially C4 isomers, while a combination of a micro-packed column with Porapak N and a PLOT capillary column with Molecular Sieve 5A is used for the fast separation of inorganic gases. A photoionization detector is a powerful additional tool for organic gas analysis.  相似文献   

6.
A fast method for the generation of permanent hydrophilic capillary coatings for capillary electrophoresis (CE) is presented. Such interior coating is effected by treating the surface to be coated with a solution of glutaraldehyde as cross-linking agent followed by a solution of poly(vinyl alcohol) (PVA), which results in an immobilization of the polymer on the capillary surface. Applied for capillary zone electrophoresis (CZE) such capillaries coated with cross-linked PVA exhibit excellent separation performance of adsorptive analytes like basic proteins due to the reduction of analyte-wall interactions. The long-term stability of cross-linked PVA coatings could be proved in very long series of CZE separations. More than 1000 repetitive CE separations of basic proteins were performed with stable absolute migration times relative standard deviation (RSD > 1.2%) and without loss of separation efficiency. Cross-linked PVA coatings exhibit a suppressed electroosmotic flow and excellent stability over a wide pH range.  相似文献   

7.
High-efficiency separations of peptide mixtures, tryptic digest and other biological compounds have been achieved using nanoscale packed capillaries and capillary zone electrophoresis (CZE). The coaxial continuous-flow fast atom bombardment design is an excellent interface for coupling these separation techniques with mass spectrometry (MS). In addition, this interface is very useful for the acquisition of MS-MS data from compounds separated by nanoscale packed capillary liquid chromatography and CZE. Structurally informative daughter-ion spectra can be obtained at the low picomole to femtomole level.  相似文献   

8.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

9.
Summary A very fast method for continous monitoring of BTEX compounds in different matrices is described. The use of a new graphite-lined (GLOT) capillary column, allows the complete separation of BTEX at isothermal conditions and very short analysis time. The same column is also able to separate polar compounds and other VOCs.  相似文献   

10.
刘玉兰  陈雅莉  肖小华  夏凌  李攻科 《色谱》2020,38(10):1197-1205
样品前处理能将待测物从复杂基质中预先分离富集出来,以提高分析方法的灵敏度、选择性和准确性,是复杂样品分析的关键步骤。样品前处理是一个非自发的、从无序到有序的熵减过程,不仅费时费力,还极易引起误差。向体系输入能量和降低体系熵值可以增强分离富集效果,加快样品制备过程。将电场引入在线样品前处理,既能向体系做功,又能驱动样品定向迁移,使前处理的熵减过程快速顺利进行,是快速样品制备的有效途径。基于电驱动的在线分离富集技术综合了多种加速策略:(1)以电场形式向体系输入能量,加速传质和传热过程;(2)采用电渗流、电泳等电驱动定向流实现样品在分离、富集、检测各步骤之间的定向迁移,保证样品前处理与检测顺利进行;(3)利用在线联用技术集成样品前处理与分析检测各步骤,从而提高自动化程度,减少人为误差;(4)通过微型化装置或微萃取方法提高样品制备效率,缩短样品制备时间。该文总结了近10年与基于电驱动的在线快速分离富集技术相关的90多篇文献,综述了该技术领域的研究进展,探讨了电驱动毛细管在线快速分离富集技术、电驱动芯片在线快速分离富集技术和电驱动膜萃取在线分离富集技术各自的优势和潜力,并展望了该类技术的发展与应...  相似文献   

11.
Electrokinetic chromatography using a fused silica capillary and sodium dodecyl sulfate (SDS) solution has been applied to the separation and determination of cefpiramide (CPM) in human plasma with the use of antipyrine (AP) as an internal standard. A plasma sample was introduced into the capillary by siphoning. The calibration plot for CPM in plasma sample showed good linearity in the concentration range over 10 to 300 micrograms/ml. This method has advantages over usual high performance liquid chromatography (HPLC) in that it needs only a very small volume (less than 10 nl) of plasma without pretreatment, and an extremely high separation efficiency (10 times or much higher plate number than usual HPLC) is obtained. The addition of SDS to the supporting electrolyte solution enabled (1) rapid release of protein-bound drug which allowed the total concentration to be determined, (2) reproducible results to be obtained by suppressing adsorption of protein onto the fused silica capillary and (3) rapid separation of drug from proteins by selective retardation of protein peaks.  相似文献   

12.
Hamer M  Yone A  Rezzano I 《Electrophoresis》2012,33(2):334-339
We report a new method of immobilization of gold nanoparticles (AuNPs) on a fused-silica capillary through covalent binding. The resulting modified capillary was applied to electrophoretic systems to improve the efficiency of separation and the selectivity of selected solutes. The immobilization of AuNPs on the capillary wall was performed in a very simple and fast way without requiring heating. The surface features of an AuNP-coated capillary column were determined using the scanning electron microscopy. The chromatographic properties of AuNP-coated capillaries were investigated through variation of the buffer pH and separation voltage. Effective separations of synthetic peptides mixture were obtained on the AuNP-coated capillaries. The method shows a remarkable stability since it was reused about 900 times. The capacity factor was duplicated. Therefore, this modification is stable and can be applied to different separation purposes. A complex mixture of tryptic peptide fragments of HSA was analyzed in both the bare- and the AuNP-coated capillaries. Better electrophoretic peptide profile was observed when using the AuNP-coated capillary.  相似文献   

13.
A rapid method for determining the separation conditions for chiral resolution of eleven beta-blocking drug substances by capillary electrophoresis is described, using an experimental design approach. An acidic phosphate-triethanolamine buffer and an uncoated fused-silica capillary were used for all experiments. Several modified cyclodextrins were applied as chiral selectors: sulfobutyl ether beta-cyclodextrin (SBE-beta CD), dimethyl beta-cyclodextrin (DM-beta CD), carboxymethyl beta-cyclodextrin (CM-beta CD), and hydroxypropyl beta-cyclodextrin (HP-beta CD). Two different fractional factorial experimental designs were applied: (1) a design examining four factors at three levels (3(4-2)) and (2) one examining three factors at two levels (2(3-1)). The factors studied were: type of cyclodextrin, cyclodextrin concentration, pH of the background electrolyte and percentage of organic modifier. Enough resolution for the separation of the enantiomers and even for their quantification was reached. The same scheme is proposed when a fast chiral separation method needs to be developed for other drug families.  相似文献   

14.
An inexpensive thread-based system for simple and rapid blood grouping   总被引:1,自引:0,他引:1  
This study investigates the use of thread as a flexible and low-cost substrate for the rapid grouping of blood. The use of a capillary substrate such as thread for blood grouping utilises the sensitivity of the flow resistance of large particles in narrow capillary channels to separate agglutinated red blood cells (RBCs) from plasma. Large and discrete particles formed in a continuous liquid phase do not provide capillary wicking driving force and fall behind the capillary wicking front, leading to their separation from the wicking liquid. The capillary substrate therefore provides a very promising but different mechanism for the separation of the agglutinated RBCs and the blood serum phase compared to most existing blood grouping methods. The principle of chromatographic separation is also exploited in this study via the use of suitable dyes to enhance the visual detection of the agglutinated RBCs and the serum phase; surprising and encouraging outcomes are obtained. Using a thread-based device, the ABO and Rh groups can be successfully determined with only 2 μL of whole blood from a pricked finger tip within 1 min and without pre-treatment of the blood sample. It is hoped that a new, inexpensive, rapid and simple method may provide an easy-to-use blood grouping platform well suited to those in developing or remote regions of the world.  相似文献   

15.
Ueda M  Kiba Y  Abe H  Arai A  Nakanishi H  Baba Y 《Electrophoresis》2000,21(1):176-180
A laser-induced fluorescence detection system coupled with a highly sensitive silicon-intensified target (SIT) camera is successfully applied to the imaging of a band for DNA fragment labeling by fluorescence dye in a microchannel, and to the visualizing of the separation process on a microfabricated chip. We demonstrated that an only 6 mm separation channel is sufficient for the separation of triplet repeat DNA fragment and DNA molecular marker within only 12 s. The separation using the microfabricated capillary electrophoresis device is confirmed to be at least 18 times faster than the same separation carried out by conventional capillary electrophoresis with 24.5 cm effective length. The use of a short capillary with 8.5 cm effective length is also efficient for fast separation of DNA; however, the microchip technology is even faster than capillary electrophoresis using a short capillary.  相似文献   

16.
A sequential injection-capillary electrophoresis (SI-CE) system for the fast and automated quantitative analysis of anions and cations is described. Because of the low sample load in capillary electrophoresis a split injection approach had to be used to achieve reliable hydrodynamic injection. The use of a capillary of 8 cm effective length allowed for the separation of five inorganic cations within 11 s. One common electrolyte solution containing 12 mM l-histidine and 2 mM 18-crown-6 whose pH value was adjusted to 4.0 with 10% v/v acetic acid was used for anions and cations, thus the analysis of both groups of analytes could be carried out in rapid sequence simply by switching the polarity of the high voltage supply. The system also allows automated flushing of the capillary. Detection limits between about 2 and 5 micromol l(-1) could be achieved with the contactless conductivity detector employed.  相似文献   

17.
A GC/FID methodology for determination of twenty-one free amino acids in quince fruit (pulp and peel) and jam is described. The sample preparation was simple, involving a SCX Solid-Phase Extraction (SPE) purification step and a fast derivatization with ethyl chloroformate for gas chromatographic analysis. The chromatographic separation was achieved using a CP-Sil 19 CB wcot fused-silica capillary column. Under the chosen conditions, with temperature and pressure programming, this capillary column was able to separate all the amino acids not only in a short time but also with good separation. The GC/FID procedure is rapid, sensitive, reproducible and accurate. The detection limit values for amino acids were low, between 0.004 and 0.115 microg/mL, and the method was precise. As a general rule, the recovery values were high. Due to its rapidity and low cost, this technique can be useful in the quality control of quince products.  相似文献   

18.
Lu M  Zhang L  Qiu B  Feng Q  Xia S  Chen G 《Journal of chromatography. A》2008,1193(1-2):156-163
A new method for rapid separation and sensitive detection of beta-blockers by pressure-assisted capillary electrochromatography (pCEC) with electrospray ionization mass spectrometry (ESI-MS) using silica-based monolithic column was studied in this paper. The proposed method has been confirmed to be very powerful since the fast mass transfer property and good permeability of silica monolithic column was used in this pCEC-ESI-MS system. In this work, a silica monolithic column was prepared with sol-gel method for simultaneous fast separation of beta-blockers. Furthermore, in order to obtain the highly selective and sensitive result of pCEC-ESI-MS, both the CEC separation and MS detection parameters were optimized in detail. Under the optimized conditions, namely 80% acetonitrile and 20% 20 mmol/L ammonium acetate (pH 6.0) as the mobile phase, 20 kV and 8 bar as the separation voltage and the assisted pressure, isopropanol/water (1:1, v/v) containing 7.5 mmol/L acetic acid as the sheath liquid, and 3 microL/min as the flow rate of sheath liquid, seven beta-blockers were well separated within 11 min with detection limits in the range of 0.15-0.80 ng/mL (defined as S/N=3). The recoveries of spiked urine samples of these beta-blockers were between 86.3 and 103% with the RSDs lower than 8.0%. The real samples from some male volunteers were successfully analyzed and confirmed with the proposed method. Comparing with GC-MS or LC-MS, the new method has some superiority (such as fast analysis capacity and simple pretreatment) in clinical practice and doping control.  相似文献   

19.
Liquid chromatography and capillary electrophoresis are unique tools for fast and efficient modeling of pharmacokinetic properties of drug candidates. Therefore numerous new separation methods and procedures have very recently been introduced to facilitate the high-throughput screening of biopartitioning features of xenobiotics. This report is a concise, up-to-date review of progress in the chromatographic assessments of data of importance for medicinal chemistry and molecular pharmacology.  相似文献   

20.
In this study, procedures based on volatile ammonium acetate buffer electrolytes of high pH value containing different organic solvent modifiers have been developed to achieve very high efficiency separations of histidine-containing synthetic peptides by high-performance capillary electrophoresis (HPCE) employing untreated fused silica capillaries. Different organic solvents, including acetonitrile, methanol and ethanol, at high volume fractions were used to modify the composition of the background buffer electrolyte. With the peptides investigated, it was found that methanol had the greatest effect in terms of enhancement of separation efficiency, as determined from the evaluation of theoretical plate numbers, N, of these HPCE systems. On the other hand, separation selectivities, e.g. the alpha(ij) values, did not change significantly as the volume fraction, psi, of the organic solvents was increased up to psi = 60% (v/v). Under these conditions, very rapid, e.g. 1-2 min, separation times could be still achieved. Compared to the effect of carrying out the separation of these peptides at constant voltage, a dramatic increase in the separation efficiency was also achieved by applying a linear voltage gradient during the HPCE experiment. Under optimal conditions of organic solvent composition and linear voltage gradient ramps, very high peak efficiencies for the studied set of synthetic peptides with N values of approximately 2-3 million theoretical plates per meter could be routinely obtained with fast analysis times. Moreover, these buffer electrolyte conditions are compatible with direct interfacing of the HPCE effluent to electrospray ionisation and ion trap mass spectrometers, thus expanding the analytical capabilities of these HPCE systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏