首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites.  相似文献   

2.
The determination of a group of eighteen pollutants in waters, including polycyclic aromatic hydrocarbons and substituted phenols, is conducted in direct-immersion solid-phase microextraction (SPME) using the polymeric ionic liquid (PIL) poly(1-vinyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl]imide as a novel coating material. The performance of the PIL fiber coating in the developed IL-SPME-gas chromatography (GC)–mass spectrometry (MS) method is characterized by average relative recoveries of 92.5% for deionized waters and 90.8% for well waters, average precision values (as relative standard deviations, RSD%) of 11% for deionized waters and 12% for well waters, using a spiked level of 5 ng mL−1. The detection limits oscillate from 0.005 ng mL−1 for fluoranthene to 4.4 ng mL−1 for 4-chloro-3-methylphenol, when using an extraction time of 60 min with 20 mL of aqueous sample. The extraction capabilities of the PIL fiber have been compared with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 μm, PDMS 100 μm and polyacrylate (PA) 85 μm. The PIL fiber is superior to the PDMS 30 μm for all analytes studied. A qualitative study was also carried out to compare among the nature of the coating materials by normalizing the coating thickness. The PIL material was shown to be more efficient than the PDMS material for all analytes studied. The PIL coating was also adequate for nonpolar analytes whereas the PA material was more sensitive for polar compounds.  相似文献   

3.
The evaluation of a novel medium‐polarity ionic‐liquid‐based gas chromatography column, SLB‐IL60, towards the analysis of a complex essential oil, namely, a peppermint essential oil sample, is reported. The SLB‐IL60 30 m column was subjected to bleeding measurements, by means of conventional gas chromatography with mass spectrometry. The SLB‐IL60 column was then evaluated in the analysis of pure standard compounds, chosen as typical constituents of peppermint essential oil. Resolution and peak symmetry (expressed as tailing factors at 10% of peak height) were measured and the results were compared to those obtained on the most widely used columns in such an application, namely a medium‐polarity [100% poly(ethyleneglycol)] stationary phase, and an apolar 5% diphenyl/95% dimethyl siloxane. The final part of the evaluation was dedicated to the gas chromatography with mass spectrometry analysis of a peppermint essential oil sample and again the data were compared to those obtained on the 100% poly(ethyleneglycol) and the 5% diphenyl/95% dimethyl siloxane phase. Linear retention indices were determined for all the identified components on the ionic liquid capillary.  相似文献   

4.
聚合离子液体毛细管气相色谱固定相的性能评价   总被引:1,自引:0,他引:1  
陈晓燕  卢凯  齐美玲  傅若农 《色谱》2009,27(6):750-754
离子液体作为毛细管气相色谱固定相的选择性和热稳定性是近年人们关注的课题。本文合成了1-烯基-3-苄基咪唑-二(三氟甲基磺酰)亚胺盐(VBIm-NTf2)离子液体并经毛细管柱内聚合制得了聚合离子液体PVBIm-NTf2色谱柱。与VBIm-NTf2色谱柱相比,PVBIm-NTf2色谱柱具有良好的色谱选择性和热稳定性。PVBIm-NTf2色谱柱对Grob试剂、醇混合物、酯混合物和苯系物等都表现了很好的分离能力,并且色谱峰峰形窄且对称。该聚合色谱柱在250 ℃下老化6 h后仍具有良好的分离能力和选择性。本文还测定了PVBIm-NTf2的Abraham溶剂化参数,解析了该固定相与溶质间的相互作用,相关研究国内尚未见报道。研究表明,对常规离子液体进行柱内聚合是改善常规离子液体气相色谱固定相的热稳定性和选择性的有效途径。  相似文献   

5.
Summary The analysis of the volatile fraction from honey requires the sugar matrix to be separated prior to the analysis by GC-MS. In this study, three extraction techniques, simultaneous extraction-distillation, liquid-liquid extraction and solid-phase extraction, were compared to the extraction of the volatile compounds of a rosemary honey. Analysis of these fractions by gas chromatography—mass spectrometry enabled the tentative identification of up to 122 volatile compounds (alcohols, ketones, aldehydes, acids, esters, terpenes, hydrocarbons, phenol, furan and pyran compounds). SDE extracts were rich in terpenes and esters, while the other two techniques avoided the formation of artefacts due to heating the sample.  相似文献   

6.
Summary Thermal desorption is a valuable method for the fractionation of plant volatile components, which can be carried out on-line with GC analysis. The use of coupled GC-MS affords additional qualitative information, of special interest for plant species whose composition has not been previously studied. Some examples of the application of automatic thermal desorption, coupled to GC-MS to the identification and characterization of volatile components of plants of different families are given.  相似文献   

7.
Determination of drugs of abuse in blood is of great importance in clinical and forensic toxicology. This review describes procedures for detection of the following drugs of abuse and their metabolites in whole blood, plasma or serum: Δ9-tetrahydrocannabinol, 11-hydroxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol glucuronide, heroin, 6-monoacetylmorphine, morphine, morphine-6-glucuronide, morphine-3-glucuronide, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, N-ethyl-3,4-methylenedioxyamphetamine, 3,4-methylenedioxyamphetamine, cocaine, benzoylecgonine, ecgonine methyl ester, cocaethylene, other cocaine metabolites or pyrolysis products (norcocaine, norcocaethylene, norbenzoylecgonine, m-hydroxycocaine, p-hydroxycocaine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, ethyl ecgonine, ecgonine, anhydroecgonine methyl ester, anhydroecgonine ethyl ester, anhydroecgonine, noranhydroecgonine, N-hydroxynorcocaine, cocaine N-oxide, anhydroecgonine methyl ester N-oxide). Metabolites and degradation products which are recommended to be monitored for assessment in clinical or forensic toxicology are mentioned. Papers written in English between 2002 and the beginning of 2007 are reviewed. Analytical methods are assessed for their suitability in forensic toxicology, where special requirements have to be met. For many of the analytes sensitive immunological methods for screening are available. Screening and confirmation is mostly done by gas chromatography (GC)–mass spectrometry (MS) or liquid chromatography (LC)–MS(/MS) procedures. Basic information about the biosample assayed, internal standard, workup, GC or LC column and mobile phase, detection mode, and validation data for each procedure is summarized in two tables to facilitate the selection of a method suitable for a specific analytic problem.  相似文献   

8.
Summary We studied the possibility of direct GC-MS determination of amphetamine hydrochloride. In order to avoid the double peak we determined the optimal injector temperature (260°C) and heating rate (40°C min−1). In the direct analysis of amphetamine hydrochloride containing samples, calibration for fragmentm/z=59 (originating from amphetaminium ion fragmentation; the calibrating agent is amphetamine hydrochloride) gave better results than calibration form/z=44 (derived from both free amphetamine and amphetaminium ion; calibration agents were amphetamine or amphetamine hydrochloride). We also compared the mass spectra of amphetamine and amphetamine hydrochloride taken by ion-trap GC-MS. The fragmentation path was cleavage of the C-C bond at benzyl position for the free base or between the phenyl group and the aliphatic moiety, in the case of free base and amphetaminium ion, respectively.  相似文献   

9.
Polyphenols belonging to the class of secondary metabolites of plants and microorganisms play an important role as bioactive food constituents as well as contaminants. Structure elucidation of polyphenols in plant extracts or polyphenol metabolites, especially those arising during biotransformation, still represents a challenge for analytical chemistry. Various approaches have been proposed to utilize fragmentation reactions in connection with mass spectrometry (MS) for structural considerations on polyphenolic targets. We compiled and applied specific liquid chromatography (LC)–electrospray ionization in positive mode [ESI(+)]–tandem MS (MS/MS) and gas chromatography (GC)–(electron impact, EI)–MS/MS fragmentation reactions with a special focus on the analysis of isoflavones, whereby this technique was also found to be extendable to determine further polyphenols. For ESI(+)-MS the basic retro-Diels–Alder (rDA) fragmentation offers information about the substitution pattern in the A- and B-rings of flavonoids and the elimination of a protonated 4-methylenecyclohexa-2,5-dienone (m/z = 107) fragment can be used as a diagnostic tool for many isoflavanones. For GC-(EI)-MS/MS analysis after derivatization of the analytes to their trimethylsilyl ethers, the elimination of methyl radicals, tetramethylsilane groups or the combined loss of two methyl groups can be shown to be specific for certain substitution patterns in polyphenols. The applicability of the fragmentation reactions presented is demonstrated exemplarily for three derivatives of the isoflavone irilone. With the help of these fragmentation reactions of the two MS techniques combined, a reliable identification of polyphenols is possible. Especially in such cases where NMR cannot be utilized owing to low analyte amounts being available or prior to purification, valuable information can be obtained. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users. Ronald Maul and Nils Helge Schebb contributed equally to this work.  相似文献   

10.
Liquid chromatography–tandem mass spectrometry (LC-MS/MS) and gas chromatography–mass spectrometry (GC-MS) have been compared for the analysis of 2-isopropyl thioxanthone (ITX) and 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB). Pressurized liquid extraction (PLE) was applied for the extraction of ITX and EHDAB from milk and milk-based beverages. Samples were homogenized with sea sand and anhydrous sodium sulfate, and were extracted with ethyl acetate at 100 °C and 10.3 × 106 Pa in one cycle of 10 min at 90% flush. Both, GC-MS and LC-MS/MS were suitable to determine these photoinitiators in the PLE extracts, providing appropriate identification and quantification. The recoveries obtained ranged from 70 to 99% for ITX and from 70 to 95% for EHDAB. These recoveries were equal as those obtained by a conventional liquid–liquid partitioning with acetonitrile and tert-butyl methyl ether–hexane. The quantification limits using GC-MS, based on a signal-to-noise ratio of 10, were 0.5 μg/L for ITX and 1 μg/L for EHDAB. The repeatability of the method, as indicated by the relative standard deviations, was within the range 0.9–16.1%. The same parameters calculated using LC-MS/MS result in quantification limits of 0.1 μg/L for ITX and 0.02 μg/L for EHDAB and repeatability within the range 5.2–19.4%. These results pointed out that both techniques are appropriate to determine these compounds in food samples. The method was applied to milk and milk-based beverages from different supermarkets. The ITX and EHDAB contents ranged from 2.5 to 325 μg/L and from 8 to 126 μg/L, respectively. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

11.
Ionic liquids (ILs) are a class of ionic, nonmolecular solvents which remain in liquid state at temperatures below 100 °C. ILs possess a variety of properties including low to negligible vapor pressure, high thermal stability, miscibility with water or a variety of organic solvents, and variable viscosity. IL-modified silica as novel high-performance liquid chromatography (HPLC) stationary phases have attracted considerable attention for their differential behavior and low free-silanol activity. Indeed, around 21 surface-confined ionic liquids (SCIL) stationary phases have been developed in the last six years. Their chromatographic behavior has been studied, and, despite the presence of a positive charge on the stationary phase, they showed considerable promise for the separation of neutral solutes (not only basic analytes), when operated in reversed phase mode. This aspect points to the potential for truly multimodal stationary phases. This review attempts to summarize the state-of-the-art about SCIL phases including their preparation, chromatographic behavior, and analytical performance.  相似文献   

12.
The interest of using ionic liquids (ILs) as stationary phases in gas chromatography (GC) has increased in recent years. This is largely due to the fact that new classes of ILs are being developed that are capable of satisfying many of the requirements of GC stationary phases. This review highlights the major requirements of GC stationary phases and describes how molten salts/ILs can be designed to largely meet these needs. The retention characteristics of organic solutes will be discussed for ammonium, pyridinium, and phosphonium-based molten salts followed by imidazolium, pyridinium, pyrollidinium, and phosphonium-based IL stationary phases. The versatility of ILs allows for the development of stationary phases based on dicationic ILs, polymeric ILs, and IL mixtures. To aid in choosing the appropriate IL stationary phase for a particular separation, the reader is guided through the different types of stationary phases available to identify those capable of providing the desired separation selectivity of organic solutes while allowing for flexibility in ranges of temperature used throughout the separation.  相似文献   

13.
The vaporization of a dicationic ionic liquid at moderate temperatures and under reduced pressures —recently studied by line‐of‐sight mass spectrometry—was further analyzed using an ion‐cyclotron resonance mass spectroscopy technique that allows the monitoring of the different species present in the gas phase through the implementation of controlled ion–molecule reactions. The results support the view that the vapour phase of an aprotic dicationic ionic liquid is composed of neutral ion triplets (one dication attached to two anions). Molecular dynamics simulations were also performed in order to explain the magnitude of the vaporization enthalpies of dicationic ionic liquids vis‐à‐vis their monocationic counterparts.  相似文献   

14.
Highest heat of vaporization yet: The dicationic ionic liquid [C3(C1Im)2][Tf2N]2 evaporates as a neutral ion triplet. These neutral ion triplets can then be ionised to form singly and doubly charged ions. The mass spectrum exhibits the dication attached to one remaining anion, and the naked dication itself (see picture).

  相似文献   


15.
The influence of confinement on the ionic liquid crystal (ILC) [C(18)C(1)Im][OTf] is studied using differential scanning calorimetry (DSC), polarized optical microscopy (POM), and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). The ILC studied is supported on Si-based powders and glasses with pore sizes ranging from 11 to 50 nm. The temperature of the solid-to-liquid-crystalline phase transition seems mostly unaffected by the confinement, whereas the temperature of the liquid-crystalline-to-liquid phase transition is depressed for smaller pore sizes. A contact layer with a thickness in the order of 2 nm is identified. The contact layer exhibits a phase transition at a temperature 30 K lower than the solid-to-liquid-crystalline phase transition observed for the neat ILC. For applications within the "supported ionic liquid phase (SILP)" concept, the experiments show that in pores of diameter 50 nm a pore filling of α>0.4 is sufficient to reproduce the phase transitions of the neat ILC.  相似文献   

16.
陈刚  赵晓洁  邢钧  姚玉华  郑京京 《色谱》2014,32(10):1117-1123
纤维素是液相色谱中应用十分广泛的一类固定相,可是由于涂渍性能不佳,纤维素在气相色谱中的应用鲜有报道。本论文首先通过酯化反应合成了脂溶性较好的三醋酸纤维素(CTA),然后与自制的聚硅氧烷离子液体(PIL-C12-NTf2)混配,制备了含纤维素的气相色谱固定相(CTA@PIL-C12-NTf2),并涂渍了毛细管柱。其柱效为3165 plates/m(110 ℃,萘,k=4.95)。麦氏常数及溶剂化参数模型的测试结果证明,该固定相属中强极性固定相,主要作用力是氢键碱性作用和偶极作用。值得注意的是,引入纤维素可明显改善三取代芳香化合物位置异构体及壬烷(C9)同分异构体的分离选择性。此外,该固定相对正构烷烃、醇、脂肪酸酯及邻苯二甲酸酯等也具有良好的分离选择性。该研究不仅初步展现了纤维素在分离选择性上的特点,而且也为探索纤维素衍生物在气相色谱中的应用提供了一条新的途径。  相似文献   

17.
1‐Butyl‐3‐[(3‐trimethoxysilyl)propyl]imidazolium chloride ionic liquid was synthesized and chemically modified onto the inner wall of a fused capillary column as a stationary phase for gas chromatography. The 1‐butyl‐3‐[(3‐trimethoxysilyl)propyl]imidazolium chloride ionic liquid bonded capillary column was evaluated in detail. The results revealed that the ionic liquid bonded capillary column exhibited high column efficiency of 1.08 × 104 plates/m, and good chromatographic separation selectivity (α ) for polar and non‐polar substances, and a good thermal stability between room temperature and 400°C. Moreover, the determination of thermodynamic parameters and the linear solvation energy relationship were further carried out. The results indicated that the chromatographic retention of each probe molecule on the ionic liquid bonded stationary phase was an enthalpy‐driven process, and the system constants of the linear solvation energy relationship signified that the dispersion interaction, the hydrogen bonding acidity and hydrogen bonding basicity were dominant interactions between probes and stationary phase among five interactions during the chromatographic separation. However, the contribution of each specific interaction for the stationary phase is ranked as the dispersion interaction > the hydrogen bonding basicity > the hydrogen bonding acidity.  相似文献   

18.
In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography–mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-μm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons. Figure SPDE Principle  相似文献   

19.
Summary In the gas chromatographic determination of polycyclic aromatic hydrocarbons (PAHs), internal standards (ISs) are frequently used in order to correct for losses and fluctuating experimental parameters. In this study eight monofluorinated PAHs (F-PAHs) are used to this end. Analysis was by means of large-volume injection-gas chromatography with mass spectrometric detection (LVI-GC-MS). Relevant experimental results and performance data are presented, and it is demonstrated that the use of at least one F-PAH as IS improves the repeatability dramatically. As a brief application, F-PAHs were used as ISs for the trace-level determination of PAHs in soil, after extraction by means of pressurized liquid extraction (PLE) and liquid partitioning (LP). The suitability of the approach was demonstrated with naphthalene and pyrene as test compounds.  相似文献   

20.
A novel method was developed for the determination of two endocrine‐disrupting chemicals, bisphenol A and 4‐nonylphenol, in vegetable oil by dispersive liquid–liquid microextraction followed by ultra high performance liquid chromatography with tandem mass spectrometry. Using a magnetic liquid as the microextraction solvent, several key parameters were optimized, including the type and volume of the magnetic liquid, extraction time, amount of dispersant, and the type of reverse extractant. The detection limits for bisphenol A and 4‐nonylphenol were 0.1 and 0.06 μg/kg, respectively. The recoveries were 70.4–112.3%, and the relative standard deviations were less than 4.2%. The method is simple for the extraction of bisphenol A and 4‐nonylphenol from vegetable oil and suitable for routine analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号