首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-performance liquid chromatographic method combined with fluorimetric detection is described for the determination of beta-carboline (norharman) and 1-methyl-beta-carboline (harman). The analysis of foodstuffs for the identification of beta-carbolines is facilitated by clean-up samples using Bond Elut PRS cartridges. Recoveries were excellent. Further, a high-performance liquid chromatographic-mass spectrometric method was also developed for their identification. The concentration of beta-carboline among the foodstuffs and alcoholic beverages varied greatly. Also, norharman and harman were observed in uncooked foodstuffs, whereas acetaldehyde was found in most fermented food. The toxicological implication of beta-carbolines in foodstuffs is discussed.  相似文献   

2.
3.
A high-performance liquid chromatographic method for the determination of metformin, an oral antidiabetic agent, in plasma is described. Plasma samples containing the internal standard, phenformin, are eluted through Amprep extraction columns before injection into the chromatographic column, packed with microBondapak phenyl. The eluent is monitored at 236 nm. At a mobile phase flow-rate of 1.35 ml/min, the retention times of metformin and phenformin are 2.8 and 5.6 min, respectively. The intra-day coefficients of variation are 1.5 and 4.3% at metformin concentrations of 0.05 and 1 mg/l, respectively.  相似文献   

4.
High-performance liquid chromatographic methods for the determination of thiamine (vitamin B1) in foodstuffs or biological tissues and fluids are outlined and discussed. The methods are often similar and interchangeable, sample extraction and clean up procedures being the major difference. Most of the methods use either ultraviolet or fluorescence detection. Fluorescence detection requires either precolumn or postcolumn oxidation of thiamine to thiochrome. A number of methods are recommended and problems with standardization are emphasized.  相似文献   

5.
6.
Summary A highly accurate and reproducible method for the determination of aprotinin (bovine pancreatic trypsin inhibitor) by HPLC is described. In the experiments, the relative standard deviation was 1.2% and detection limit 1 FIP-U cm–3. Also, the method is quick and selective and active ingredients from difference source correlate well with enzymatic method. Analyses at different laboratories can be compared directly.  相似文献   

7.
A method for the determination of 6-methyladenine (6MA) by high-performance liquid chromatography (HPLC) has been developed. DNA bases were separated by using the strong cation-exchange resin Zipax SCX. Purine bases were obtained by hydrolysis and dialysis of DNA and analysed by HPLC. 6MA in DNA from Escherichia coli was determined by the proposed method. It is suggested that the method could be applicable to analyses of 6MA from other biological sources.  相似文献   

8.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

9.
A fluorescent reversed-phase high-performance liquid chromatographic method was developed for the analysis of carbendazim in blueberries. Recoveries of fortified blueberries at 27 and 810 ng/g were more than adequate with good precision. Forty commercial blueberry samples were analyzed and the amount of carbendazim ranged from none detected (detection limit of 15 ng/g) to 155 ng/g. Confirmation of carbendazim in the blueberry samples was made by enzyme immunoassay and UV photodiode array.  相似文献   

10.
An assay using reversed-phase high-performance liquid chromatography with electrochemical detection was developed to measure hydroxyurea in plasma at concentrations suitable for pharmacokinetic studies. The sample preparation is simple, the analysis rapid and assays can be batched. The between-run precision is excellent (coefficient of variation = 2.8-4.5%) and the limit of detection is 0.02 mmol/l. Preliminary studies have shown that the method is suitable for pharmacokinetic studies.  相似文献   

11.
A simple, accurate and precise isocratic reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of p-chloronitrobenzene (p-CNB) in rat plasma. A plasma sample was deproteinized with methanol containing the internal standard (p-bromonitrobenzene). The resulting methanol eluate obtained after centrifugation was filtered and injected into a high-performance liquid chromatograph (50 microliters each). A column packed with 5 microns octadecylsilane (ODS) spherical particles was used with isocratic elution of methanol-water (45:55, v/v) at a flow-rate of 1.0 ml/min. The compounds were detected by ultraviolet absorbance at 280 nm. The retention times of p-CNB and the internal standard were 12.5 and 15.5 min, respectively, at a column oven temperature of 30 degrees C. The results were linear from 0.05 to 100 micrograms/ml (r = 0.999), and the detection limit was 0.01 microgram/ml. The relative error and the coefficient of variation on replicate assays were less than 7 and 10%, respectively, for all concentrations studied. The overall recoveries of p-CNB were between 97 and 105%. Plasma samples could be stored for up to one month at -20 degrees C.  相似文献   

12.
Luxabendazole, a new benzimidazole, is a highly potent broad-spectrum anthelmintic. A high-performance liquid chromatographic method has been developed for its determination in serum and urine samples. In order to optimize the clean-up of samples we compared two procedures: C18 Sep-Pak cartridges and ultrafiltration through a cellulose membrane with a 30,000 relative molecular mass cut-off. In order to obtain the most suitable mobile phase, we studied the influence of pH and acetonitrile content on the capacity factor (k'). Chromatographic separation and quantification were performed on a reversed-phase column packed with 5-microns Nucleosil C18. The mobile phase was acetonitrile-0.05 M phosphate buffer (pH 7.0), (40:60, v/v). The column effluent was monitored by ultraviolet-visible spectrophotometry at 290 nm. The method shows good recovery, precision and accuracy. The lower limit of detection for luxabendazole is 15 ng/ml in serum samples and 25 ng/ml in urine samples.  相似文献   

13.
A peer-verified, solid-phase extraction (SPE)/anion exchange liquid chromatographic method is presented for the determination of niacin in milk-based and soy-based infant formula. Analysis is in 3 steps: test sample digestion, extraction/cleanup, and liquid chromatography (LC). Digestion uses a standard AOAC digestion procedure that involves autoclaving at 121 degrees C for 45 min in (1 + 1) H2SO4 to free endogenous niacin from protein and to convert added niacinamide to niacin. The digest solution is adjusted to pH 6.5 with 7.5M NaOH. Acidification to pH <1.0 with (1 + 1) H2SO4 precipitates the protein. The clarified solution is then filtered, and the filtrate is brought to volume. SPE of niacin is accomplished by passing an aliquot of the digest solution through an aromatic sulfonic acid-SPE (ArSCX-SPE) column. After the column is washed with methanol and water to remove extraneous material, the niacin is eluted with 0.25M sodium acetate/acetic acid buffer at pH 5.6. An anion-exchange polystyrene-divinylbenzene column with 0.1 M sodium acetate/acetic acid buffer at pH 4.0 is used for LC. Niacin is determined by UV detection at 260 nm. A standard curve is prepared by passing known amounts of niacin through the ArSCX-SPE columns used for niacin extraction. The following values for x and relative standard deviation (RSD) were obtained for National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1846 Infant Formula with a certified value for niacin of 63.3 +/- 7.6 microg/g: Submitting laboratory.-- x = 59.7 +/- 4.0 microg/g; RSD = >6.7%; confidence interval (CI) = +/- 1.4 microg/g; n = 27. Peer laboratory.--x = 56.6 +/- 6.6 microg/g; RSD = >11.7%; CI =+/- 4.1 microg/g; n = 8.  相似文献   

14.
15.
Sulfite, sulfate, sulfide and thiosulfate ions are separated by high-performance liquid chromatography under acidic conditions on commercial low-capacity silica-based and resin-based anion-exchange columns with potassium hydrogenphthalate as the eluent. The ions are detected by using indirect ultraviolet absorption or conductivity detectors. The effects of concentration, pH and flow rate of the eluent on the retention times of sulfur anions are reported. The resin-based column is preferable to the silica-based column for separations of sulfur anions.  相似文献   

16.
The potential of high-performance liquid chromatography (HPLC) with diode-array detection for the profiling of mycotoxins in food samples has been demonstrated. A gradient elution reversed-phase chromatographic method coupled with a suitable extraction procedure was devised for the separation and detection of major Alternaria mycotoxins in foodstuffs. Altenuene, alternariol, alternariol methyl ether (dibenzo-alpha-pyrone derivatives), altertoxin-I and altertoxin-II (perylene derivatives) were profiled in extracts of artificially infected maize, rice and tomato samples and naturally contaminated sunflower seeds. First evidence of the occurrence of a new dibenzo-alpha-pyrone derivative in Alternaria cultures is also reported.  相似文献   

17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号