首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cheben P  Powell I  Janz S  Xu DX 《Optics letters》2005,30(14):1824-1826
We propose a new type of arrayed waveguide grating (AWG) device that operates as a Fourier-transform (FT) spectrometer without the need of scanning elements. The large input aperture size typical of a FT spectrometer eliminates the requirement for a narrow single-mode input waveguide while still achieving high spectral resolution with a markedly increased light-gathering capability (etendue). An example of the device with a resolution of 0.07 nm (approximately 10 GHz) and designed for a silicon-on-insulator platform is presented. The calculated spectra show no noticeable deterioration for aperture widths as large as 40 microm, yielding more than a 50-fold increase in aperture size compared with conventional AWG or echelle grating based devices at the equivalent resolution.  相似文献   

2.
A spectrometer based on the effect of freely decaying polarization in the frequency range 500–700 GHz has been designed. Radiation sources are harmonics from a quantum semiconductor superlattice frequency multiplier. The receiving system of this spectrometer is constructed using a superconducting integrated receiver based on a superconductor-insulator-superconductor mixer and a flux-flow oscillator operating as a heterodyne oscillator. The spectrometer has been used to measure absorption lines of NH3 in a sample of expired air (572 GHz).  相似文献   

3.
The T-gate stem height of In Al As/In Ga As In P-based high electron mobility transistor(HEMT) is increased from165 nm to 250 nm. The influences of increasing the gate stem height on the direct current(DC) and radio frequency(RF)performances of device are investigated. A 120-nm-long gate, 250-nm-high gate stem device exhibits a higher threshold voltage(Vth) of 60 m V than a 120-nm-long gate devices with a short gate stem, caused by more Pt distributions on the gate foot edges of the high Ti/Pt/Au gate. The Pt distribution in Schottky contact metal is found to increase with the gate stem height or the gate length increasing, and thus enhancing the Schottky barrier height and expanding the gate length,which can be due to the increased internal tensile stress of Pt. The more Pt distributions for the high gate stem device also lead to more obvious Pt sinking, which reduces the distance between the gate and the In Ga As channel so that the transconductance(gm) of the high gate stem device is 70 m S/mm larger than that of the short stem device. As for the RF performances,the gate extrinsic parasitic capacitance decreases and the intrinsic transconductance increases after the gate stem height has been increased, so the RF performances of device are obviously improved. The high gate stem device yields a maximum ft of 270 GHz and fmax of 460 GHz, while the short gate stem device has a maximum ft of 240 GHz and the fmax of 370 GHz.  相似文献   

4.
A pulsed ENDOR spectrometer operating at a microwave frequency of 275 GHz is described. The results demonstrate that this type of spectroscopy can now be performed routinely at this high microwave frequency. The advantages compared to conventional EPR frequencies are the high spectral resolution, time resolution, and sensitivity.  相似文献   

5.
Miniature digitising electronics have been coupled to a detector based on an organic liquid scintillator to form a digital neutron and gamma spectrometer. The electronics used are small enough to be packaged with a detector to form an easily portable unit. This miniaturisation has some impact on the achievable sampling rate and resolution, in comparison with the bulkier devices often used for such an application, so it is not clear which of the many pulse shape discrimination algorithms reported in the literature is best suited for use with this device. To explore this, the spectrometer was exposed to a selection of the radiation fields available at NPL, and three different neutron/gamma discrimination algorithms were compared on an equal footing. The energy resolution of the device, and its ease of use, were compared with those of a conventional analogue system.  相似文献   

6.
李金洋  逯丹凤  祁志美 《物理学报》2015,64(11):114207-114207
研究了铌酸锂波导静态傅里叶变换微光谱仪分辨率的影响因素, 并在此基础上提出了一种采用端面反射铌酸锂波导结构提高微光谱仪光谱分辨率的方法. 该方法容许在减小铌酸锂波导静态傅里叶变换微光谱仪尺寸的同时, 使两干涉臂间最大光程差增大1倍, 从而使其光谱分辨率实现倍增. 采用商业化铌酸锂波导电光调制器构建了一个傅里叶变换光谱仪原理样机, 并对样机在不同波长下的光谱分辨率进行了测量, 结果指出对调制器加载端面反射结构后获得的光谱分辨率是加载端面反射结构前的2倍, 与理论分析结果完全一致. 这种光波导端面反射结构制作工艺简单, 易于实现, 是一种提高集成光波导静态傅里叶微光谱仪分辨率的有效手段.  相似文献   

7.
A 96-element plastic-scintillator detector array has been constructed to improve the energy resolution and tagged-photon flux over a moveable energy range of up to 60MeV in the Glasgow photon tagging spectrometer at Mainz. Test results are presented which demonstrate that this device improves the resolution by a factor of about 6 compared to the main detector array. It is also shown that it is possible to achieve accurate energy calibration by using electron beams of several different accurately known energies from the Mainz accelerator.  相似文献   

8.
We overview recent achievements in the field of cryogenic submillimeter-wave receivers based on superconductor–insulator–superconductor (SIS) tunnel junctions. The main attention is paid to the novel superconducting integrated receivers (SIRs) with an on-chip superconducting local oscillator. The single-chip microcircuit of the receiver, which integrates a quantum mixer based on the nonlinearity of a quasi-particle current in the SIS junction, a planar superconducting receiving antenna, and a cryogenic local oscillator, is described. Being dc-powered only by batteries, such a microcircuit operates as a submillimeter-wave superheterodyne receiver without any additional microwave equipment. Such receivers are very attractive for radioastronomical research, space communication systems, and monitoring of the environment from satellites, balloons, and special aircraft. A breadboard of a superconducting spectrometer with a phase-locked flux-flow oscillator (FFO) has been developed and tested. A frequency resolution better than 10 kHz was reached at a frequency of 365 GHz. We describe a balloon-borne 500-650 GHz integrated spectrometer for oblique atmospheric sounding, developed for the international Terahertz Limb Sounder (TELIS) project. The first flight is scheduled for 2005.  相似文献   

9.
We have recently described a molecular beam millimeter sidebands Fourier transform spectrometer (MB-MMSBFT) (1). Basically this spectrometer makes use of a sidebands technic to move the delicate switching problem towards the centimeter range.This brief communication, reports an enhancement of the previously described spectrometer. In the actual version the molecular sample is injected along the cavity axis instead of perpendicular to this axis. The time spent by the molecules in the field is then enlarged, contributing to the enhancement in resolution. Trials have been driven with propyne and methyl cyanide, showing an ultimate linewidth of 10 kHz (HWHM) at 51 GHz.  相似文献   

10.
The development of a high frequency electron spin resonance (ESR) spectrometer with a wide frequency range using a gyrotron as the radiation power source is described.GYROTRON FU-E, optimized for use in an ESR spectrometer in the millimeter wave range, was developed in Fukui University. In order to test the normal operation of the spectrometer, the ESR of two standard samples, single crystal and polycrystalline DPPH, has been measured, in the pulsed mode over the frequency range from 65 GHz to 135 GHz.  相似文献   

11.
We describe the ESR spectrometer we developed. Our aim was twofold: i) to reach the highest possible frequency and ii) to devise a frequency tunable spectrometer. The tunable source is an optically pumped far infrared laser which has been used from 160 GHz up to 525 GHz with magnetic fields of up to 19 T. We present measurements performed in semiconductor physics and in molecular chemical physics. These measurements allowed us to distinguish electric dipolar transitions from magnetic dipolar transitions. The increase ing-factor resolution was used to discriminate between entities withg-factors differing by a few 10?5. This property together with the study of the line-width frequency dependence was used in geophysics. We studied the spin relaxation mechanisms of the model system Phosphorus doped Silicon. The variation of the spin relaxation time with temperature shows the importance of two-phonon mechanisms. High frequency tunable ESR makes possible the study of compounds with large zero field splitting which are ESR silent at standard frequencies.  相似文献   

12.
The sensitivity of a high-frequency electron spin resonance (ESR) spectrometer depends strongly on the structure used to couple the incident millimeter wave to the sample that generates the ESR signal. Subsequent coupling of the ESR signal to the detection arm of the spectrometer is also a crucial consideration for achieving high spectrometer sensitivity. In previous work, we found that a means for continuously varying the coupling was necessary for attaining high sensitivity reliably and reproducibly. We report here on a novel asymmetric mesh structure that achieves continuously variable coupling by rotating the mesh in its own plane about the millimeter-wave transmission-line optical axis. We quantify the performance of this device with nitroxide spin label spectra in both a lossy aqueous solution and a low-loss solid-state system. These two systems have very different coupling requirements and are representative of the range of coupling achievable with this technique. Lossy systems, in particular, are a demanding test of the achievable sensitivity and allow us to assess the suitability of this approach for applying high-frequency ESR, e.g., to the study of biological systems at physiological conditions. The variable coupling technique reported on here allows us to readily achieve a factor of ca. 7 improvement in the signal-to-noise ratio at 170 GHz and a factor of ca. 5 at 95 GHz over what has previously been reported for lossy samples.  相似文献   

13.
程知群  周肖鹏  胡莎  周伟坚  张胜 《物理学报》2010,59(2):1252-1257
对新型复合沟道AlxGa1-xN/AlyGa1-yN/GaN高电子迁移率晶体管(HEMT)进行了优化设计.从半导体能带理论与量子阱理论出发,自洽求解了器件层结构参数对器件导带能级以及二维电子气(2DEG)中载流子浓度和横向电场的影响.用TCAD软件仿真得到了器件的层结构参数对器件性能的影响.结合理论分析和仿真结果确定了器件的最佳外延层结构Al0.31Ga0.69N/Al0.04Ga0.96N/GaNHEMT.对栅长1μm,栅宽100μm的器件仿真表明,器件的最大跨导为300mS/mm,且在栅极电压-2—1V的宽范围内跨导变化很小,表明器件具有较好的线性度;器件的最大电流密度为1300mA/mm,特征频率为11.5GHz,最大振荡频率为32.5GHz.  相似文献   

14.
A 1.55 μm InGaAsP-InP partly gain-coupled two-section DFB self-pulsation laser (SPL) with a varied ridge width has been fabricated. The laser produces self-pulsations with a frequency tuning range of more than 135 GHz. All-optical clock recovery from 40 Gb/s degraded data streams has been demonstrated. Successful lockings of the device at frequencies of 30 GHz, 40 GHz, 50 GHz, and 60 GHz to a 10 GHz sidemode injection are also conducted, which demonstrates the capability of the device for all-optical clock recovery at different frequencies. This flexibility of the device is highly desired for practical uses.  相似文献   

15.
The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for ascronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acousto-optical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J=76 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (<2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.  相似文献   

16.
The structure of an 1GeV/c wide-range magnetic spectrometer is briefly described.The spectrometer includes the magnet system and the detector & data acquisition system.The momentum formula at extended edge field case for non-focusing magnetic spectrometer has been derived.The momentum resolution,solid angle,momentum acceptance and other parameters for this spectrometer are calculated by Monte Carlo simulation.The effects of the multiple scattering and position resolution of the detectors to momentum resolution of this spectrometer are discussed.  相似文献   

17.
A novel electron paramagnetic resonance (EPR) spectrometer is reported, which has been developed to allow pulsed EPR experiments with high sensitivity and time resolution at a microwave (MW) frequency of 180 GHz (G-band) and wavelengths of approximately 1.6 mm. This corresponds to a magnetic field of about 6.4 T forg ≈ 2 signals. The “hybrid” system architecture combines components of quasioptical as well as conventional MW techniques, making it possible to achieve excellent spectrometer performance with respect to sensitivity and time resolution. Quasioptical MW components have been used to design an MW circulator allowing high sensitivity and low bias operation in the reflection mode. A miniaturized, closed-type cylindrical cavity provides a high sample filling factor and an adequate MW field strength (B1) enhancement and thus permits reasonably short MW pulses (60 ns for a π/2 pulse) even with a moderate MW input power (15 mW at the cavity). Commercial quartz capillaries (up to 0.5 mm internal diameter) can be used as sample holders for a broad range of applications.  相似文献   

18.
A submillimeter-wave/far-infrared (SMM/FIR) laser sideband heterodyne spectrometer has been built for molecular rotational spectroscopy application in the frequency range of 600–3000 GHz. Based on Gaussian optics, optical system of the spectrometer is designed to be quasi-achromatic and low losses. In this article the optical design and the performance of the spectrometer are presented.  相似文献   

19.
Conduction-electron spin resonance in thin aluminium platelets, coated with a plastic surface layer, has been studied in a reflection spectrometer at 60 GHz. It is shown that the data on linewidth and g-factor fall in line with recent measurements at 21 GHz by the present authors and partly also with earlier measurements at 1.27 GHz 9.27 GHz, 35 GHz and 79 GHz by others.  相似文献   

20.
We report a mode-locked Ti:sapphire femtosecond laser with 5GHz repetition rate. Spectral broadening of the 24 fs pulses in a microstructured fiber yields an octave-spanning spectrum and permits self-referencing and active stabilization of the emitted femtosecond laser frequency comb (FLFC). The individual modes of the 5 GHz FLFC are resolved with a high-resolution spectrometer based on a virtually imaged phased array spectral disperser. Isolation of single comb elements at a microwatt average power level is demonstrated. The combination of the high-power, frequency-stabilized 5 GHz laser and the straightforward resolution of its many modes will benefit applications in direct frequency comb spectroscopy. Additionally, such a stabilized FLFC should serve as a useful tool for direct mode-by-mode Fourier synthesis of optical waveforms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏