首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
A new and sensitive high-performance chromatographic method for the determination of bisphenol A and 8 alkylphenols with fluorescence detection is reported. Each phenol was derivatized by reaction with 2-(4-carboxyphenyl)-5,6-dimethylbenzimidazole at 40 degrees C for 60 min. The fluorescence derivatives were separated on a Wakosil 5C18 column (4.0 i.d. x 300 mm, 5 microm) with methanol:water (10:90) as mobile phase (detection wavelength: lambda(ex) 336 nm, lambda(em) 440 nm). The detection limits were in the range of 0.1-10.0 pg/mL in serum. The calibration graphs were linear to 1.0 microg/mL. The relative standard deviations were 7.2-8.9%, respectively. The proposed method was applied to the determination of bisphenol A in mother and infant rat serum.  相似文献   

2.
The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn (20 mm x 2.1 mm i.d., packed with 30 microm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column (125 mm x 4 mm i.d., LiChrospher 100 RP18, 5 microm), and monitored at 262 nm. The method was applied to the measurement of TMA in air in the 0.25-2.5 microg interval (equivalent to concentrations of TMA of 1.1-11 mg/m3), providing good linearity, reproducibility and accuracy. The mean recovery of TMA was (96 +/- 7%) (n = 12), and the limit of detection was 0.05 microg. The proposed procedure allows the selective determination of TMA in the presence of other primary and secondary short-chain aliphatic amines.  相似文献   

3.
An original analytical method has been developed for the determination of the antioxidants trans-resveratrol (t-RSV) and cis-resveratrol (c-RSV) and of melatonin (MLT) in red and white wine. The method is based on HPLC coupled to fluorescence detection. Separation was obtained by using a RP column (C8, 150 mm x 4.6 mm id, 5 mum) and a mobile phase composed of 79% aqueous phosphate buffer at pH 3.0 and 21% ACN. Fluorescence intensity was monitored at lambda = 386 nm while exciting at lambda = 298 nm, mirtazapine was used as the internal standard. A careful pretreatment of wine samples was developed, using SPE with C18 cartridges (100 mg, 1 mL). The calibration curves were linear over the following concentration ranges: 0.03-5.00 ng/mL for MLT, 3-500 ng/mL for t-RSV and 1-150 ng/mL for c-RSV. The LOD values were 0.01 ng/mL for MLT, 1 ng/mL for t-RSV and 0.3 ng/mL for c-RSV. Precision data, as well as extraction yield and sample purification results, were satisfactory. Thus, the method seems to be suitable for the analysis of MLT and resveratrol isomers in wine samples. Moreover, wine total polyphenol content and antioxidant activity were evaluated.  相似文献   

4.
A rapid, sensitive and specific high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the determination of oxatomide in human plasma. Flunarizine hydrochloride was employed as the internal standard (IS). The analytes were chromatographically separated on a Shimadzu Shim-pack VP-ODS C18 column (250 x 2.0 mm i.d.) with a mobile phase consisting of methanol and aqueous ammonium acetate solution (10 mm, pH 4.0; 85:15, v/v). Detection was performed on a single quadrupole mass spectrometer using an electrospray ionization interface with the selected-ion monitoring (SIM) mode. The method showed excellent linearity (r = 0.9995) over the concentration range of 0.5-500 ng/mL with good accuracy and precision. The intra- and inter-batch precisions were within 10% relative standard deviation. The recoveries were more than 90%. The validated method was successfully applied to a preliminary pharmacokinetic study of oxatomide in Chinese healthy male volunteers.  相似文献   

5.
An instrumental set up including on-line solid-phase extraction, nano-liquid chromatography, and nanospray mass spectrometry is constructed to improve the sensitivity for quantitation of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in surface water. Sample volumes of 1000 microL are loaded onto a microbore 1.0-mm i.d. x 5 mm, 5 microm Kromasil C(18) enrichment column by a carrier solution consisting of 10mM ammonium acetate in acetonitrile-water (10:90, v/v) at a flow rate of 250 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 0.1-mm i.d. x 150 mm, 3.5 microm Kromasil C(18) analytical column is conducted using an acetonitrile-10mM ammonium acetate solvent gradient from 30% to 70% acetonitrile. Water samples are added with internal standard (perfluoroheptanoic acid) and filtrated prior to injection. The mass limits of detection of PFOA and PFOS are 0.5 and 1 pg, respectively, corresponding to concentration limits of detection of 500 pg/L and 1 ng/L, respectively. The total time spent on sample preparation, chromatography, and detection is approximately 12 min per sample. The method was employed for the determination of PFOS and PFOA in urban river water.  相似文献   

6.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

7.
王晓春  王涵文  马继平  徐烨  关亚风 《色谱》2004,22(2):101-105
首次将填充毛细管高效液相色谱-毛细管气相色谱在线联用技术(μ-HPLC-CGC)用于分离分析八角茴香果实的挥发油成分。液相色谱选用氰基分析柱(250 mm×0.32 mm i.d.),正己烷-乙腈-二氯甲烷(体积比为80∶8∶12)为流动相,对挥发油样品做族组分分离,得到的5个族组分被依次存放在多位储存接口内,然后不分流分别转入毛细管气相色谱仪做详细分析。气相色谱柱由10 m×0.53 mm i.d.保留间隔柱和30 m×0.53 mm i.d.×1.0 μm SE-54分析柱组成。采用了不分流柱内进样模  相似文献   

8.
A rapid, sensitive and selective method for the simultaneous determination of bromadiolone, flocoumafen and brodifacoum in whole blood using warfarin as internal standard (IS) by high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC/ESI-MS) has been developed and validated. The target compounds were extracted from the whole blood with ethyl acetate and separated on an XDB C18 column (150 mm x 2.1 mm i.d. x 5 microm) by using a mobile phase consisting of 0.2% acetic acid/methanol (12/88, v/v) at a constant flow rate of 0.50 mL/min. The analytes were detected using negative ESI-MS in the selected ion monitoring (SIM) mode. The molecular ions [M-H]- of m/z 527, 541,523 and 307 were selected for the quantification for bromadiolone, flocoumafen, brodifacoum and the IS, respectively. The calibration curves were linear (r2 > 0.995) in the concentration range of 0.50-100.00 ng/mL. The method showed a satisfactory sensitivity (0.05-0.5 ng/mL using 200 microL blood), precision (RSD < 11.9%), accuracy (recovery: 82.0-96.1%) and selectivity. This method was successfully applied to the determination of the analytes for the diagnoses of poisoned human beings and animals.  相似文献   

9.
植物中酞酸酯的分析测定研究   总被引:5,自引:0,他引:5  
建立了二氯甲烷超声提取、小粒径硅胶住色谱项分离、UV-HPLC测定植物中酞酸酯的方法,简便、快速,可使酞酸酯与杂质有效分离,回收率为85%~101%。用于实际植物样品中酞酸酯的测定,结果满意。  相似文献   

10.
高效液相色谱法测定硝苯柳胺含量   总被引:7,自引:0,他引:7  
龙彩云  陈生田  施天益 《色谱》1998,16(1):76-77
硝苯柳胺是合成筛选出来的一种新杀螺剂。经实验探索,以3,5-二硝基苯甲酸作内标,采用并建立了高效液相色谱法测定合成物中硝苯柳胺的含量。方法简便、准确,灵敏度高。  相似文献   

11.
气相色谱法测定肌醇   总被引:9,自引:0,他引:9  
申书昌  张晓慧 《色谱》2000,18(3):265-266
 :将肌醇进行乙酰化衍生后得到肌醇六乙酯,然后用气相色谱法分析肌醇六乙酯,测得肌醇的含量。这种分析方法的变异系数为0.15%,回收率为98.2%~104.3%。方法简捷,是一种较好的测定肌醇含量的方法。  相似文献   

12.
Two on-line configurations using multiple 6- and 10-port valves were investigated for high-flow on-line extraction of a basic drug in rat plasma and human urine using a reversed-phase and a cation-exchange SPE sorbent. The first configuration studied was a single reversed-phase extraction cartridge (2.1 x 20 mm, 25 microm) using an optimized washing protocol. The results showed that up to 1.5 mL of sample (urine or plasma diluted 1:1) can be injected with limits of quantification (LOQs) as low as 100 pg/mL. The second configuration studied was the combination of a cation exchanger and a reversed-phase cartridge using at-column dilution. The results showed better LOQs than those obtained with the single cartridge at 10 pg/mL with the same injection volume. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration curves gave an average of 5% relative standard deviation (RSD).  相似文献   

13.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated to simultaneously determine mifepristone and monodemethyl-mifepristone in human plasma using levonorgestrel as the internal standard (IS). After solid-phase extraction of the plasma samples, mifepristone, monodemethyl-mifepristone and the IS were subjected to LC-MS/MS analysis using electro-spray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Chromatographic separation was performed on an XTERRA MS C(18) column (150 x 2.1 mm i.d., 5 microm). The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration ranges of 5-2000 ng/mL for mifepristone and monodemethyl-mifepristone. The recoveries of the method were found to be 94.5-103.7% for mifepristone and 70.7-77.3% for monodemethyl-mifepristone. The method had a lower limit of quantification (LLOQ) of 5.0 ng/mL and a lower limit of detection (LOD) of 1.0 ng/mL for both mifepristone and monodemethyl-mifepristone. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 10, 100 and 1000 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity. The validated LC-MS/MS method was successfully used in a pharmacokinetic study in healthy female volunteers after oral administration of 25 mg mifepristone tablet.  相似文献   

14.
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.  相似文献   

15.
A solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry for the determination of estrogens in sewage influent and effluent has been performed. The possibility of preparing estrogen derivatives directly on a solid-phase extraction bed in which the targeted analytes have been previously isolated and pre-concentrated was explored. This method uses an Oasis HLB column (2.1 mm x 20 mm i.d.) for on-line sample cleanup and derivatization support, and a Sunfire C(18) column (150 mm x 2.1 mm i.d.) with a mobile phase consisting of acetonitrile-water-formic acid for separation. After sample introduction, some matrix interferences are removed by washing up SPE column with methanol-water. Phenolic hydroxyl group of estrogens is subsequently derivatized with dansyl chloride. Reaction takes place in the on-line solid-phase extraction column. The excess of reagent and other matrix interferences are then removed by a second washing. Dansylated estrogens are further back eluted and analyzed with HPLC-MS-MS. The optimized on-line protocol is emphasized owing to a low limit of quantification (1 ng L(-1)) is achieved with only around 1 mL of sample and a low sensitive MS instrument. Developed strategy has been demonstrated to be an improvement over existing methods due to its greater sensitivity and the low volume of matrix used and the total analysis time (extraction, derivatization, analysis) is less than 17 min.  相似文献   

16.
An accurate and selective method for the simultaneous determination of triptolide, tripdiolide and tripterine in human urine using hydrocortisone as an internal standard (IS) by high-performance liquid chromatography coupled with atmospheric-pressure chemical ionization mass spectrometry in negative ion mode has been developed. After triptolide, tripdiolide and tripterine in human urine were extracted with ethyl acetate and cleaned by solid-phase extraction with C(18) cartridges, a satisfactory separation was achieved on an XDB C(18) short column (30 x 2.1 mm i.d., 3 microm) using the mobile phase of acetic acid-ammonium acetate (5 mmol/L, pH = 4.5)-acetonitrile-methanol in gradient elution. Detection was operated by APCI in selected ion monitoring mode. The target ions m/z 359, m/z 375, m/z 449 and m/z 419 were selected for the quantification of triptolide, tripdiolide, tripterine and IS, respectively. The linear range was 1.0-100.0 ng mL(-1), and the limits of quantification in human urine were found to be 0.1-0.5 ng mL(-1) for the three compounds. The precisions (CV%) and accuracies were 6.6-12.9 and 85.1-97.0%, respectively. The developed method could be applied to the determination of triptolide, tripdiolide and tripterine in human urine for diagnosis of the intoxication and for forensic purposes.  相似文献   

17.
A rapid, sensitive, and simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method for the determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using sildenafil as an internal standard (IS) was developed and validated. Udenafil, DA-8164 and IS from a 100 microL aliquot of biological samples were extracted by protein precipitation using acetonitrile. Chromatographic separation was carried on an Acquity UPLC BEH C(18) column (50 x 2.1 mm, i.d., 1.7 microm) with an isocratic mobile phase consisting of acetonitrile and containing 0.1% formic acid (75:25, v/v) at flow rate of 0.4 mL/min, and total run time was within 1 min. Detection and quantification was performed by the mass spectrometer using multiple reaction-monitoring mode at m/z 517 --> 283 for udenafil, m/z 406 --> 364 for DA-8164 and m/z 475 --> 100 for IS. The assay was linear over a concentration range of 1-600 ng/mL with a lower limit of quantification of 1 ng/mL in both human plasma and urine. The coefficient of variation of this assay precision was less than 13.7%, and the accuracy exceeded 92.0%. This method was successfully applied for pharmacokinetic study after oral administration of udenafil 100 mg to healthy Korean male volunteers.  相似文献   

18.
An on-line pre-concentration method for the analysis of five benzoylureas (diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron) in ground water samples was evaluated using two C(18) columns, and fluorescence detection after photochemical induced fluorescence (PIF) post-column derivatization. The trace enrichment was carried out with 35 mL of ground water modified with 15 mL of MeOH on a 50 mm x 4.6 mm I.D. first enrichment column (C-1) packed with 5 microm Hypersil Elite C(18). Retention properties of pesticides and humic acids usually contained in ground water were studied on C-1 at concentration levels ranging between 0.04 and 14.00 microg/L in water samples. The results obtained in this study show that the pesticides are pre-concentrated in the first short column while the humic acids contained in the ground water samples are eluted to waste. Pesticides recoveries ranged between 92.3 and 109.5%. The methodology proposed was used to determine benzoylureas in ground water samples at levels lower than 0.1 microg/L (maximum levels established by the European Union).  相似文献   

19.
In order to evaluate the pharmacokinetic (PK) profile of rabeprazole (RA) sterile powder for injection, a rapid, sensitive and specific assay for quantitative determination of RA in dog plasma was developed and validated. After a liquid-liquid extraction procedure, samples were analyzed by liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) using omepazole as the internal standard (IS). The analyte and IS was chromatographed on a ZORBAX Extend-C(18) analytical column (50 x 2 mm i.d, 5 microm, Agilent Technologies, USA). The assay was linear in the range 1-2000 ng/mL. The lower limit of quantification of RA was 1 ng/mL. The recovery of RA was greater than 70%. The within- and between-batch accuracy was 102.7-107.4% and 103.5-105.7%, respectively. The plasma samples for the PK study were collected at defined time points during and after an intravenous injection (1 mg/kg) to beagle dogs and analyzed by LC-ESI-MS method. The PK parameters, such as half-life, volume of distribution, total clearance and elimination rate constant, were determined. The PK profile of RA gave insights into the application in the clinics.  相似文献   

20.
The current study aims to develop a specific and sensitive LC-MS/MS method for determination of bis(7)-tacrine (B7T) in rat plasma. A 100 microL plasma sample was extracted with ethyl acetate. B7T and the internal standard (IS), pimozide, in the samples were then analyzed with LC-MS/MS in positive electrospray ionization condition. Chromatographic separation of B7T and IS was achieved in a C(18) reversed-phase HPLC column (150 x 2.1 mm i.d.) by isocratic elution with a mobile phase consisting of 0.05% formic acid in water and acetonitrile (1:1, v/v) at a flow rate of 0.35 mL/min. Multiple-reaction monitoring (MRM) mode was employed to measure the ion transitions: m/z 247 to 197 for B7T and m/z 462 to m/z 328 for IS, respectively. The method was linear over the studied ranges of 100-5000 and 10-100 ng/mL. The intra-day and inter-day variations of the analysis were less than 6.8% with standard errors less than 9.0%. The detection limit of B7T in rat plasma was 1 ng/mL. The developed method was successfully applied to the pharmacokinetic study of B7T after intravenous administration of 1 mg/kg B7T and further proved to be readily utilized for determination of B7T in rat plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号