首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Direct detection of free induction decays and electron spin echoes, and the recording of echo-detected EPR spectra and electron spin echo envelope modulation patterns at a microwave frequency of 2.5 GHz is demonstrated. This corresponds to the measurement of the transverse magnetization in the laboratory frame, rather than in the rotating frame as usually done by down-converting the signal (homodyne detection). An oscilloscope with a 6-GHz analog bandwidth, a sampling rate of 20 GigaSamples per second, and a trigger frequency of 5 GHz for the edge trigger and 750 MHz for the advanced trigger, is used in these experiments. For signal averaging a 3-GHz microwave clock divider has been developed to synchronize the oscilloscope with the frequency of the EPR signal. Moreover, direct detection of continuous wave EPR signals at 2.5 GHz is described.  相似文献   

2.
For whole body EPR imaging of small animals, typically low frequencies of 250-750 MHz have been used due to the microwave losses at higher frequencies and the challenges in designing suitable resonators to accommodate these large lossy samples. However, low microwave frequency limits the obtainable sensitivity. L-band frequencies can provide higher sensitivity, and have been commonly used for localized in vivo EPR spectroscopy. Therefore, it would be highly desirable to develop an L-band microwave resonator suitable for in vivo whole body EPR imaging of small animals such as living mice. A 1.2 GHz 16-gap resonator with inner diameter of 42 mm and 48 mm length was designed and constructed for whole body EPR imaging of small animals. The resonator has good field homogeneity and stability to animal-induced motional noise. Resonator stability was achieved with electrical and mechanical design utilizing a fixed position double coupling loop of novel geometry, thus minimizing the number of moving parts. Using this resonator, high quality EPR images of lossy phantoms and living mice were obtained. This design provides good sensitivity, ease of sample access, excellent stability and uniform B(1) field homogeneity for in vivo whole body EPR imaging of mice at 1.2 GHz.  相似文献   

3.
EPR resonators on the basis of standing-wave cavities are optimised for large samples. For small samples it is possible to design different resonators that have much better power handling properties and higher sensitivity. Other parameters being equal, the sensitivity of the resonator can be increased by minimising its size and thus increasing the filling factor. Like in NMR, it is possible to use lumped elements; coils can confine the microwave field to volumes that are much smaller than the wavelength. We discuss the design and evaluation of EPR resonators on the basis of planar microcoils. Our test resonators, which operate at a frequency of 14 GHz, have excellent microwave efficiency factors, achieving 24 ns pi/2 EPR pulses with an input power of 17 mW. The sensitivity tests with DPPH samples resulted in the sensitivity value 2.3 x 10(9) spins.G(-1) Hz(-1/2) at 300 K.  相似文献   

4.
This paper investigates basic characteristics of the electron paramagnetic resonance (EPR) signal obtained from spectrometers employing reflection resonators. General equations are presented which reveal the phase and amplitude dependence on instrumental parameters of both components of the continuous wave (CW) EPR signal (absorption and dispersion). New phase vector diagrams derived from these general equations are presented for the analysis of the EPR response. The dependence of the phase and absolute value of the CW EPR signal on the local oscillator (LO) phase and on resonator offset and coupling is presented and analyzed. The EPR spectrometer tuning procedures for both balanced and unbalanced heterodyne receivers are analyzed in detail using the new phase diagrams. Extraneous signals at the RF input of the microwave receiver (resulting from circulator leakage and reflections in the resonator transmission line) have been taken into account and analyzed. It is shown that a final tuning condition that corresponds to an extremum of the receiver output as a function of the resonator frequency is necessary and sufficient for the acquisition of pure absorption signal. This condition is universal: it applies to all spectrometer configurations in all frequency ranges. High Frequency EPR spectrometer (130 GHz) data are used to generate experimental phase diagrams that illustrate the theoretical concepts presented in the paper. Conditions are presented under which the absorption signal can be measured with complete suppression of the dispersion, independent of the mutual frequency offset between the microwave source and the EPR sample resonator. Equations describing the approximate relationship between changes of the resonator properties (Q-factor and frequency) and paramagnetic susceptibility are derived and analyzed.  相似文献   

5.
High-field/high frequency EPR spectroscopy measurements are shown. Experiments were carried out at 240- and 316-GHz frequencies. The employed apparatus uses a novel combination of far infrared molecular lasers and of probehead exploiting dielectric resonators working in the whispering gallery modes. This approach constitutes a relatively simple method of multifrequency EPR spectroscopy and opens appealing perspectives in high-sensitivity EPR spectroscopy up to the THz regime.  相似文献   

6.
Stochastic excitation with a full-width-half-maximum bandwidth of 250 MHz was used to perform Fourier-transform (FT) high-field/high-frequency electron paramagnetic resonance (EPR) at 3.4T/95 GHz (W-band). Thereby, the required microwave peak power is reduced by a factor of tau(p)/T1 as compared to equivalent pulsed FT EPR in which the spin system with spin-lattice relaxation time T1 is excited by a single microwave pulse of length tau(p). Stochastic EPR is particularly interesting under high-field/high-frequency conditions, because the limited output power of mm microwave sources, amplifiers, and mixers makes pulse FT EPR in that frequency domain impossible, at least for the near future. On the other hand, FT spectroscopy offers several advantages compared to field-swept magnetic resonance methods, as is demonstrated by its success in NMR and X-band EPR. In this paper we describe a novel stochastic W-band microwave bridge including a bimodal induction mode transmission resonator that serves for decoupling the microwave excitation and signal detection. We report first EPR measurements and discuss experimental difficulties as well as achieved sensitivity. Moreover, we discuss future improvements and the possibility for an application of stochastic W-band FT EPR to transient signals such as those of photoexcited radical pairs in photosynthetic reaction centers.  相似文献   

7.
Simulations are performed of 34- and 9-GHz EPR spectra, together with 94-GHz EPR spectra, from phospholipid probes spin-labelled at the C4-C14 positions of the sn-2 chain, in liquid-ordered and gel-phase membranes of dimyristoyl phosphatidylcholine with high and low cholesterol contents. The multifrequency simulation strategy involves: (i) obtaining partially averaged spin-Hamiltonian tensors from fast-motional simulations of the 94-GHz spectra; (ii) performing slow-motional simulations of the 34- and 9-GHz spectra by using these pre-averaged tensors with the stochastic Liouville formalism; (iii) constructing, by simulation, slow-motional calibrations for the differences, DeltaA(zz)(qx) and Deltag(zz)(qx), in effective A(zz)-hyperfine splittings and g(zz)-values between 34- (or 94-GHz) and 9-GHz spectra; (iv) using such calibrations for DeltaA(zz)(qx) and Deltag(zz)(qx) and dynamic parameters from stage (ii) as a guide to adjust the extent of pre-averaging of the spin-Hamiltonian tensors; and (v) repeating the 34- and 9-GHz simulations of stage (ii). By using this scheme it is possible to obtain consistent values of the rotational diffusion coefficients, D(R perpendicular) and D(R//), and the long-axis order parameter, S(zz), that characterize the slow axial motion of the lipid chains, from spectra at both 34 and 9GHz. Inclusion of spectra at 34GHz greatly improves precision in determining the D(R//) element of the slow diffusion tensor in these systems.  相似文献   

8.
纳米机械振子尺寸小,质量轻,可以用来制作探测力、质量等微小物理量的超灵敏探测器.石墨烯拥有质量轻、密度低和杨氏模量高等特性,被认为是制作纳米机械振子的理想材料.石墨烯纳米机械振子因其具有的谐振频率高、品质因子高和谐振频率可调性高等优势,近年来得到了人们的广泛关注.作为表征纳米机械振子性能的一个重要指标,品质因子越高,意味着纳米机械振子耗散越低,纳米机械振子的灵敏度越高.本文通过微纳加工的工艺制备出一种谐振频率随栅压可调(调节的范围为73 MHz~90 MHz)的石墨烯纳米机械振子样品,研究其在极低温高真空环境下的品质因子与栅极电压之间的关系.实验表明通过栅压调节振子的内部应力,能够使石墨烯纳米机械振子品质因子从220提高到1000.我们的结果为二维材料纳米机械振子的耗散研究提供了一种新的研究思路.  相似文献   

9.
Design strategies, system configuration, and operation of a dual-channel data acquisition system for a radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) spectrometer/imager operating at 300 MHz are described. This system wasconfigured to incorporate high-speed analog-to-digital conversion (ADC) and summation capabilities with both internal and external triggering via GPIB interface. The sampling rate of the ADC is programmable up to a maximum of 1 GS/s when operating in a dual-channel mode or 2 GS/s when the EPR data are collected in a single-channel mode. By using high-speed flash ADCs, a pipelined 8-bit adder, and a 24-bit accumulator, a repetition rate of 230 kHz is realized to sum FIDs of 4096 points. The record length is programmable up to a maximum of 8K points and a large number of FIDs (2(24)) can be summed without overflow before the data can be transferred to a host computer via GPIB interface for further processing. The data acquisition system can operate in a two-channel (quadrature) receiver mode for the conventional mixing to baseband. For detection using the single-channel mode, the resonance signals around the center frequency of 300 MHz were mixed with a synchronized local oscillator of appropriate frequency leading to an intermediate frequency (IF) which is sampled at a rate of 2 GS/s. Comparison of quadrature-mode and an IF-mode operation for EPR detection is presented by studying the FID signal intensity across a bandwidth of 10 MHz and as a function of transmit RF power. Imaging of large-sized phantoms accommodated in appropriately sized resonators indicates that IF-mode operation can be used to obtain distortion-free images in resonators of size 50 mm diameter and 50 mm length.  相似文献   

10.
Freshwater ice in a cavity was studied under heating to 0°C followed by cooling at a frequency of 6.3 GHz. Splitting of a resonant transmission line at 60–70 MHz was detected. This effect may be associated with the existence of two vibrational modes in ice, with the coupling between them increasing near 0°C. In such a medium, two waves with identical polarizations and similar wavenumbers can exist. This assumption was confirmed experimentally by measuring the 13-GHz radiation transmission through a natural freshwater ice cover. These measurements detected signal oscillations caused by the interference of two waves, with alternation of maxima and minima with a period of 4.6 m, which corresponds to a beat frequency of ~37 MHz.  相似文献   

11.
New EPR resonators were developed by using a ceramic material with a high dielectric constant, epsilon=160. The resonators have a high quality factor, Q=10(3), and enhance the sensitivity of an EPR spectrometer up to 170 times. Some advantages of the new ceramic resonators are: (1) cheaper synthesis and simplified fabricating technology; (2) wider temperature range; and (3) ease of use. The ceramic material is produced with a titanate of complex oxides of rare-earth and alkaline metals, and has a perovskite type structure. The resonators were tested with X-band EPR spectrometers with cylindrical (TE(011)) and rectangular (TE(102)) cavities at 300 and 77K. We discovered that EPR signal strength enhancement depends on the dielectric constant of the material, resonator geometry and the size of the sample. Also, an unusual resonant mode was found in the dielectric resonator-metallic cavity structure. In this mode, the directions of microwave magnetic fields of the coupled resonators are opposite and the resonant frequency of the structure is higher than the frequency of empty metallic cavity.  相似文献   

12.
The Umbella high-frequency electron paramagnetic resonance (EPR) facility is a part of the Nijmegen High Field Magnet Laboratory with special emphasis on multifrequency EPR for chemical and biological applications. At present the facility has various solid-state sources available for the frequency range between 95 and 400 GHz, combined with magnetic fields up to 30 T. For frequencies above 400 GHz a far-infrared laser is used. With superheterodyne detection techniques a typical dynamical range of 130 dB is obtained, with single-mode resonators, oversized cylindrical and Fabry-Perot resonators. Some examples will be shown to demonstrate the power of multifrequency EPR in high-spin systems.  相似文献   

13.
Electron paramagnetic resonance spectra of the S3/? radical center in ultramarine blue over a factor of about 2500 in frequency (258 MHz to 670 GHz) reveal a substantially Lorentzian shape, without resolution of g anisotropy. Variable temperature measurements found that the line width is independent of temperature, within experimental uncertainty, up to about 90 K at 9.5 GHz and between ca. 5 K and room temperature at 95 and 217 GHz, as expected for an exchange-narrowed signal. Analysis of the increase in the low-temperature line width as a function of frequency above 9 GHz is consistent with an exchange interaction of about 2· 10?2 K. The line width increases as frequency is decreased from 2.7 GHz to 258 MHz which is attributed to the contribution from nonsecular terms that has been denoted the “10/3” effect.  相似文献   

14.
Petroleum of Arabian and Colombian origin was studied by electron paramagnetic resonance (EPR) spectroscopy at X- (9 GHz), Q- (34 GHz) and W-bands (94 GHz). The experiments were performed at room temperature (about 300 K) and at 77 K (W-band only). The asymmetry in the lines corresponding to free radicals was observed more intensely in the W-band spectra. The values of the line width ΔH in the spectra increased linearly with the microwave frequency utilized in the EPR experiments. A mathematical simulation of the free radical signal for the EPR spectra in three bands with a set of parameters corresponding to a single species was attempted, but this was not exactly coincident with the experimental signals, suggesting that the hyperfine interaction of the unpaired electron with its neighborhood corresponds to more than one species of radical in the molecular structure of the petroleum asphaltene.  相似文献   

15.
We describe a frequency tunable Q-band cavity (34 GHz) designed for CW and pulse Electron Paramagnetic Resonance (EPR) as well as Electron Nuclear Double Resonance (ENDOR) and Electron Electron Double Resonance (ELDOR) experiments. The TE(011) cylindrical resonator is machined either from brass or from graphite (which is subsequently gold plated), to improve the penetration of the 100 kHz field modulation signal. The (self-supporting) ENDOR coil consists of four 0.8mm silver posts at 2.67 mm distance from the cavity center axis, penetrating through the plunger heads. It is very robust and immune to mechanical vibrations. The coil is electrically shielded to enable CW ENDOR experiments with high RF power (500 W). The top plunger of the cavity is movable and allows a frequency tuning of ±2 GHz. In our setup the standard operation frequency is 34.0 GHz. The microwaves are coupled into the resonator through an iris in the cylinder wall and matching is accomplished by a sliding short in the coupling waveguide. Optical excitation of the sample is enabled through slits in the cavity wall (transmission ~60%). The resonator accepts 3mm o.d. sample tubes. This leads to a favorable sensitivity especially for pulse EPR experiments of low concentration biological samples. The probehead dimensions are compatible with that of Bruker flexline Q-band resonators and it fits perfectly into an Oxford CF935 Helium flow cryostat (4-300 K). It is demonstrated that, due to the relatively large active sample volume (20-30 μl), the described resonator has superior concentration sensitivity as compared to commercial pulse Q-band resonators. The quality factor (Q(L)) of the resonator can be varied between 2600 (critical coupling) and 1300 (over-coupling). The shortest achieved π/2-pulse durations are 20 ns using a 3 W microwave amplifier. ENDOR (RF) π-pulses of 20 μs ((1)H @ 51 MHz) were obtained for a 300 W amplifier and 7 μs using a 2500 W amplifier. Selected applications of the resonator are presented.  相似文献   

16.
Herein, a novel double-inverse E-structured resonator metamaterial (MTM) surrounded by split-ring resonators (SRRs) is introduced and proposed. The proposed MTM has working frequency ranges of 1.62 – 1.79 GHz, 2.08 – 2.21 GHz, 4.39 – 4.99 GHz, and 5.65 – 6.09 GHz. In addition, the proposed MTM can be applied in digital cellular system uplinks (DCS) (1.736 GHz), earth exploration-satellite communication (EESC) (2.148 GHz), lower band 5G (4.8 GHz), and WiMAX (5.89 GHz) applications. The electromagnetic radiation reduction performance of the proposed MTM is investigated at 900 MHz and 1800 MHz of GSM cellular bands. The Finite Integration Technique (FIT) based on high-frequency electromagnetic software is utilised for the development of design along with a detailed investigation of the MTM properties. The proposed MTM is formed by developing a double-inverse E-structure in the middle surrounded by SRRs. The resonator structure with SRRs is implemented on an epoxy resin FR4 substrate, which has a compact size of 11.11 × 11.11 mm2. The unit cell has a high effective medium ratio of 14.82. Furthermore, the developed MTM shows a negative refractive index region from 3.124 to 6.98 GHz and double-negative region from 3.94 to 4.57 GHz, 5.26 to 5.49 GHz, and 6.29 to 6.88 GHz. In addition, SAR evaluation is also performed to test the competence of utilising the proposed MTM on modern mobile phones. The MTM has an electromagnetic absorption rate of about 44% and 43% at 900 MHz and 1800 MHz, respectively, for 1g whereas about 43% and 44% at 900 MHz and 1800 MHz, respectively, for 10g. Thus, the performance and characteristics of the developed MTM can be utilised for the above-mentioned applications.  相似文献   

17.
Loop-gap resonator (LGR) technology has been extended to W-band (94GHz). One output of a multiarm Q-band (35GHz) EPR bridge was translated to W-band for sample irradiation by mixing with 59 GHz; similarly, the EPR signal was translated back to Q-band for detection. A cavity resonant in the cylindrical TE011 mode suitable for use with 100 kHz field modulation has also been developed. Results using microwave frequency modulation (FM) at 50 kHz as an alternative to magnetic field modulation are described. FM was accomplished by modulating a varactor coupled to the 59 GHz oscillator. A spin-label study of sensitivity was performed under conditions of overmodulation and gamma2H1(2)T1T2<1. EPR spectra were obtained, both absorption and dispersion, by lock-in detection at the fundamental modulation frequency (50 kHz), and also at the second and third harmonics (100 and 150 kHz). Source noise was deleterious in first harmonic spectra, but was very low in second and third harmonic spectra. First harmonic microwave FM was transferred to microwave modulation at second and third harmonics by the spins, thus satisfying the "transfer of modulation" principle. The loaded Q-value of the LGR with sample was 90 (i.e., a bandwidth between 3 dB points of about 1 GHz), the resonator efficiency parameter was calculated to be 9.3 G at one W incident power, and the frequency deviation was 11.3 MHz p-p, which is equivalent to a field modulation amplitude of 4 G. W-band EPR using an LGR is a favorable configuration for microwave FM experiments.  相似文献   

18.
Electron spin relaxation times for four triarylmethyl (trityl) radicals at room temperature were measured by long-pulse saturation recovery, inversion recovery, and electron spin echo at 250 MHz, 1.5, 3.1, and 9.2 GHz in mixtures of water and glycerol. At 250 MHz T(1) is shorter than at X-band and more strongly dependent on viscosity. The enhanced relaxation at 250 MHz is attributed to modulation of electron-proton dipolar coupling by tumbling of the trityl radicals at rates that are comparable to the reciprocal of the resonance frequency. Deuteration of the solvent was used to distinguish relaxation due to solvent protons from the relaxation due to intra-molecular electron-proton interactions at 250 MHz. For trityl-CD(3), which contains no protons, modulation of dipolar interaction with solvent protons dominates T(1). For proton-containing radicals the relative importance of modulation of intra- and inter-molecular proton interactions varies with solution viscosity. The viscosity and frequency dependence of T(1) was modeled based on dipolar interaction with a defined number of protons at specified distances from the unpaired electron. At each of the frequencies examined T(2) decreases with increasing viscosity consistent with contributions from T(1) and from incomplete motional averaging of anisotropic hyperfine interaction.  相似文献   

19.
An electron paramagnetic resonance (EPR) probe consisting of two dielectric resonators (DRs) and a cavity (CV) is ideal for EPR experiments where both signal enhancement and tuning capabilities are required. The coupling of two DRs, resonating in their \({\text{TE}}_{01\delta }\) mode and a CV resonating in its \({\text{TE}}_{011}\) mode, is studied using energy-coupled mode theory (ECMT). The frequencies and eigenvectors of the three coupled modes are analytically derived. As predicted numerically, ECMT confirms that the \({\text{TE}}^{ + + - }\) and \({\text{TE}}^{ + - - }\) modes are indeed found to be degenerate at a specific distance between the two DRs \(d_{12}\). Additionally, the condition at which degeneracy occurs is specified. For a considerable range, the calculated frequency of the \({\text{TE}}^{ + + + }\) mode changes linearly with respect to \(d_{12}\). The \({\text{TE}}^{ + + + }\) mode showed a 500 MHz frequency change over a distance of 2 cm, when the resonance frequency is around 9.7 GHz. This enables the experimentalist to linearly tune the probe over this large frequency range. Finally the asymmetric configuration, where one of the resonators (DR2) is kept at the cavity center and the other one is allowed to move along the cavity axis, is studied. It is estimated that the frequency changes by 600 MHz over a distance of 1.5 cm. A formula for the magnitude of the magnetic field along the cavity axis, where the EPR samples are usually placed, is developed. This is crucial in determining the magnetic field in the vicinity of the sample and the probe’s filling factor.  相似文献   

20.
A frequency modulation (FM) method was developed to measure electron paramagnetic resonance (EPR) absorption. The first-derivative spectrum of 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder was measured with this FM method. Frequency modulation of up to 1.6 MHz (peak-to-peak) was achieved at a microwave carrier frequency of 1.1 GHz. This corresponds to a magnetic field modulation of 57microT (peak-to-peak) at 40.3 mT. By using a tunable microwave resonator and automatic control systems, we achieved a practical continuous-wave (CW) EPR spectrometer that incorporates the FM method. In the present experiments, the EPR signal intensity was proportional to the magnitude of frequency modulation. The background signal at the modulation frequency (1 kHz) for EPR detection was also proportional to the magnitude of frequency modulation. An automatic matching control (AMC) system reduced the amplitude of noise in microwave detection and improved the baseline stability. Distortion of the spectral lineshape was seen when the spectrometer settings were not appropriate, e.g., with a lack of the open-loop gain in automatic tuning control (ATC). FM is an alternative to field modulation when the side-effect of field modulation is detrimental for EPR detection. The present spectroscopic technique based on the FM scheme is useful for measuring the first derivative with respect to the microwave frequency in investigations of electron-spin-related phenomena.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号