首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
To determine the composition of niobium–rare-earth ores by atomic emission spectrometry and inductively coupled plasma mass spectrometry, two procedures are developed for sample preparation based on autoclave decomposition and flux fusion. Autoclave decomposition is carried out in a mixture of HF and HNO3 at a temperature of up to 220°C and a pressure of up to 160 atm using a developed system with resistive heating. Subsequent evaporation to dry salts ensures the removal of F ions and silicon as SiF4. The residue is dissolved in a mixture of HCl and H2O2 at 160°C under elevated pressure. The resulting solutions (10% with respect to HCl with the addition of H2O2) are diluted before measurements. The dissolution process is monitored for each sample using stable highly enriched isotopes of 91Zr, 100Mo, 149Sm, and 178Hf. The second procedure is based on fusing samples with a mixture of Na2CO3 and Na2B4O7 at 1050°C in a muffle furnace and dissolving the resulting melt in a mixture of HCl and H2O2. The procedures were tested using the national (NFS-23) and foreign standard samples of composition (OREAS-462, 463, 464, 465, Australia) and real samples of niobium–rare-earth ores.  相似文献   

2.
A procedure for the determination of As, Cd, Cr, Ni, Pb, and V in phytotherapy medicines by inductively coupled plasma–tandem mass spectrometry is reported. The use of tandem mass spectrometry with oxygen into an octopole reaction system at various gas flow rates and the combination of on-mass and mass-shift modes was evaluated. Cadmium, Cr, Ni, and Pb were determined as free atomic ions while As and V were determined as the oxides AsO+ and VO+ in the same run. Samples were prepared by microwave-assisted digestion with dilute nitric acid and hydrogen peroxide. Two plant-certified reference materials (apple leaves and tomato leaves) were used to check the accuracy. For tandem mass spectrometry with 0.5?mL min?1 O2, recoveries in the 85–113% were typically obtained and no statistical differences were observed at the 95% confidence level (t-test) in comparison with the certified values. Using these conditions, the limits of detection for the method were 0.01, 0.0002, 0.008, 0.008, 0.003, and 0.002?µg g?1 for As, Cd, Cr, Ni, Pb, and V, respectively. The procedure was used for the analysis of four phytotherapic drugs and the determined concentrations were up to 0.168?µg g?1 As, 0.03?µg g?1 Cd, 0.82?µg g?1 Cr, 1.18?µg g?1 Ni, 0.52?µg g?1 Pb, and 2.4?µg g?1 V with average precision values of 8% as the relative standard deviation. The found concentrations were compared with limits proposed in official guidelines and, in most cases, the values were below the maximum limits allowed.  相似文献   

3.
A method for the precise and accurate determination of phosphorus in crude oil and middle distillate petroleum products was developed using inductively coupled plasma–optical emission spectrometry to rapidly determine phosphorus as a control method. The presence of phosphorus is undesirable in petrochemical products as it complexes with other metals generating residues that interrupt normal operation of refineries. The presence of phosphorus may be due to some anti-fouling additives or the crude oils processed. Consequently, it is necessary to control the phosphorus present at trace levels in the crude oil and in process streams that present various densities and viscosities. The instrumental power, nebulizer flow, pump rate, read time, and the sample preparation conditions were optimized. The desired level of quantification for the petrochemical industry was achieved allowing the simultaneous analysis of diverse liquid petroleum products.  相似文献   

4.
The selection of the most suitable dilution methods for determination of trace elements in human serum using inductively coupled plasma mass spectrometry is reported. The trace elements were Al, V, Cr, Fe, Mn, Co, Cu, Zn, As, Cd, Sn, Tl, and Pb. The performance of various dilution methods was assessed by precision, linearity, detection limits, quantification limits, fortified recoveries, and the analysis of reference materials. The results demonstrate that diluted solution containing only nitric acid is most suitable for As, Cr, Mn, and Co in serum. Dilute solutions containing nitric acid and Triton X-100 were most appropriate for Cu, Zn, Cd, and Tl. The optimum conditions for Al, V, Mn, Fe, Cr, Co, Sn, and Pb used tetra-n-butylammonium hydroxide, Triton X-100, and ethylenediamine tetraacetic acid.  相似文献   

5.
A zoom–time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom–time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7× over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time—compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3–5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.
Graphical Abstract ?
  相似文献   

6.
This study investigated the content of macronutrients (Ca, K, Mg, Na, P, and S), trace elements (Ba, Be, Co, Cr, Cu, Fe, Ga, Li, Mn, Ni, Rb, Se, Sr, V, and Zn), and trace toxic elements (As, Cd, In, Pb, and Tl) in chili powder from Korea, China, and Vietnam. For the analyses, inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) were used. In addition, near-infrared (NIR) spectroscopy was used to differentiate functional groups based on the chemical constituents. For the validation of the applied analytical methods, good linearity (coefficients of determination, 0.9443–0.99997), and relative standard deviations below 4% were obtained. The contents of the toxic elements were below the provisional tolerable weekly intake values. Linear discriminant analysis using elemental contents and NIR data was performed to establish and authenticate the geographical origin of chili powder, which confirmed the reliability of the obtained results.  相似文献   

7.
Procedures for the determination of aluminum in water for injections (Aqua ad iniectabilia) and high-purity water (Aqua valde purificata) at a level of several µg?L?1 using atomic-emission spectrometry with a novel microwave plasma (MP–AES) and inductively coupled plasma (ICP–AES) are proposed. Regardless of the atomic-emission technique used, the procedure for aluminum needs no sample preparation (acidification only), no preconcentration, shows high sensitivity (limits of detection of 0.4 and 0.7?µg?L?1 for ICP–AES and MP–AES with a polymeric inert concentric nebulizer, respectively, and 0.03?µg?L?1 for ICP–AES with an ultrasonic nebulizer), high precision (repeatability, relative standard deviation, <5%), and high throughput (25 samples per hour), and is considerably simpler and more expedient from the viewpoint of the analysis cost and time compared with the standard spectrofluorimetric procedure of the US and the European Pharmacopoeia.  相似文献   

8.
The advent of multiple collector–inductively coupled plasma–mass spectrometry (MC-ICP-MS) has made the high-precision determination of Ge isotopes possible, which leads to the widespread application of Ge isotopes in earth, ocean, and cosmochemistry fields. This paper reviews the history of Ge isotope analysis, chemical dissolution and purification, and mass spectrometry measurements. Concentrated HNO3 is sufficient to dissolve nearly all types of samples and HF is also involved for Si-rich samples. Low-temperature ashing prior to dissolution is an alternative way to preconcentrate Ge in organic-rich samples. For different matrices, Ge isotopes can be determined by MC-ICP-MS coupled with a traditional nebulizer system or hydride generation system after two-step separation, one step cation/anion-exchange separation, or Mg/Fe co-precipitation protocols. Ion-exchange column methods are suitable for samples with elevated matrix and Ge content such as sulfides, iron oxides, silicate rocks, and coals, whereas Mg or Fe coprecipitation methods are particularly suitable for all kinds of water. Hydride generation systems are improved over traditional nebulizer system due to the smaller sample quantity and fewer matrix-related interferences. Sample-standard bracketing, double spike, and external Ga isotope normalization are used to mass bias correction and yield consistent results. Analytical methods involving Ge-poor samples and Ge isotope analyses based on different Ge species or specific Ge compound in natural environment will be important prospects in the further study. For further applications of Ge isotopes in mineral deposits such as sulfide and iron oxide deposits, sulfides, and iron oxides reference materials should be developed in the future.  相似文献   

9.
《Analytical letters》2012,45(11):1921-1930
This paper describes a simple and sensitive method for the determination of manganese in human urine by graphite furnace atomic absorption spectroscopy (GFAAS), which includes sample preparation by microwave digestion. Matrix modifier combinations, the digestion power, pyrolysis, and atomization temperatures were optimized. A mixture of 5.0 µg Pd(NO3)2 and 3.2 µg Mg(NO3)2 modifier presented the best performance. The optimal temperatures for pyrolysis and atomization were 1500°C and 1950°C, respectively. The GFAAS method was compared to inductively coupled plasma–mass spectrometry (ICP–MS) for the determination of manganese in urine. Analytical figures of merit for GFAAS and ICP–MS were: accuracy (3.46%, 2.19%), precision (3.61%, 5.84%), LOD (0.109 µg · L?1, 0.015 µg · L?1), LOQ (0.327 µg · L?1, 0.045 µg · L?1), and recovery (80–100%, 74–89%). Both methods were employed for the determination of Mn in urine and the results were compared statistically.  相似文献   

10.
《Analytical letters》2012,45(17):3198-3209
Abstract

Six metals (cadmium, copper, nickel, lead, iron, and zinc) were determined by inductively coupled plasma–optical emission spectrometry in crawfish (tails and whole bodies) and soil in the vicinity of the crawfish, in a season of 4 months (February through May) in southwest Louisiana. Cadmium and lead were not found in the tail or whole body. Nickel was found in some samples of tail but mostly in the April and May samples. Copper, iron, and zinc were found in both tail and whole body of the crawfish. Limited soil sampling showed no cadmium, nickel, or copper in soil, but levels of iron, lead, and zinc were detected.  相似文献   

11.
Because of its high sensitivity, wide dynamic range and relative freedom from interferences, inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the determination of trace and ultra-trace levels of elements in various fields1. Due…  相似文献   

12.
《Analytical letters》2012,45(16):2639-2649
The rapid speciation of lead is reported by high performance liquid chromatography and inductively coupled plasma – mass spectrometry. The separation of inorganic lead, trimethyllead, triethyllead and triphenyllead was achieved within 3.5 minutes on a C18 column using a gradient program of methanol and water containing 5 milligrams per liter sodium 1-pentanesulfonate at pH 5. The limits of detection for inorganic lead, trimethyllead, triethyllead, and triphenyllead were 0.01, 0.02, 0.02, and 0.02 micrograms per liter, respectively. The accuracy of the method was verified by the analysis of water (GSBZ 50009-88) and seawater (GBW (E) 080040) certified reference materials. The method was also employed for the analysis of water samples; inorganic lead was measured in river water.  相似文献   

13.
Possibilities of inductively coupled plasma atomic emission spectrometry (ICP AES) as an alternative to X-ray spectrochemical analysis are estimated in the determination of matrix elements of glasses of As–Se and As–S systems. Standard solutions were prepared from pure elements As, Se and S. It was shown that the matrix elements of glasses can be determined with an expanded uncertainty of 0.05–0.1 mol %. The results of determinations by ICP AES and X-ray fluorescence spectrometry were compared; and it was found that by the attained performance characteristics, the results of ICP AES are highly competitive with the data of X-ray fluorescence spectrometry, but do not require sets of adequate solid reference samples.  相似文献   

14.
Cobalt metal has been used in the production of magnetic alloys, cobalt and nickel based superalloys and sputtering targets in the field of advanced electronic devices1. The determination of trace impurities in high purity cobalt is extremely important be…  相似文献   

15.
ICP- AEShasbecome a widely used technique formulti- elemental major,minorand traceanalyses.However,many elements such as REEsare often presentin real samples atconcen-trations too low to be accurately determined by conventional ICP,especially in biological andenvironmental samples.Moreover the spectral interferences from matrix elementsoften inter-fere with trace REEsdetermination.To determine trace and ultra- trace REEsin complex ma-trices,the separation of the matrix components and th…  相似文献   

16.
17.
lntroductionIngenera1,microwaveplasmaatomicemissionspectrometry(MWP-AES)isanexcel1enttechniqueforthedeterminationofnonmetalelements.AlthoughtheMWP-AEShasbeenextensivelyappliedtothedeterminationofnonmetals,suchasS,P,Cl,BrandI[1],therehavebeenonlyafewreportsonthedeterminationforcarbon.Mitchelletal.[2Jreportedafurnace-microwaveplasmasystemtode-termineorganicandinorganiccarbon.Samplesweredispensedintoplatinumboatsandinsertedintoafurnace.TheresultantvaporwasfedtoanArMWPandcarbonemissionatl…  相似文献   

18.
The concentrations of eight essential (Co, Cr, Cu, Mn, Ni, Se, V, and Zn) and five toxic elements (Al, As, Cd, Hg, and Pb) were determined in 457 samples of commonly consumed fresh tropical fruit including bananas (Musa acuminata), kiwi (Actinidia deliciosa), mangos (Mangifera indica), and pineapple (Ananas comosus) from supermarkets from Seoul, Busan, Gangneung, Daegu, Daejeon, and Gwangju, South Korea. The samples were digested by microwave-assisted combustion using HNO3 and H2O2 and determined by inductively coupled plasma mass spectrometry. The Hg concentrations were evaluated by furnace-gold amalgamation direct mercury analysis. The techniques were validated by linearity, limits of detection and quantification, precision, recovery, and the analysis of a NIST-1570a spinach leaves certified reference material. The concentrations of essential elements varied considerably among the tropical fruit. Overall, the tropical fruit was higher in Mn (0.027–13.2?µg/g) and Zn (0.514–2.20?µg/g), while lower in Co (0.002–0.005?µg/g) and V (0.001–0.002?µg/g). The concentrations (µg/g) of toxic elements were 0.001 (kiwi) to 0.003 (mango) for As and Cd, 0.0004 (pineapple) to 0.002 (banana) for Hg, and 0.005 (kiwi) to 0.013 (mango) for Pb. The calculated values of estimated dietary intake, target hazard quotients and hazard indices were lower than one and the safety limits established by World Health Organization. The tropical fruits were therefore safe and did not pose any threat to consumers.  相似文献   

19.
《Analytical letters》2012,45(11):2297-2306
Abstract

The performance of inductively coupled plasma–atomic emission spectrometry (ICP‐AES) for the determination of 14 lanthanides and Yttrium was evaluated by comparison with inductively coupled plasma–mass spectral (ICP‐MS) analysis. The geochemical reference samples (GRS), DNC‐1(diabase), AGV‐1(andesite), Sy‐2(syenite), MRG‐1(gabbro), AN‐G(anorthosite), AC‐E(granite), and MAG‐1(marine mud) were chosen as test materials and analyzed for checking the precision and reproducibility of the methods. The mineral garnet is separated from the black sands of the southwest coast of India, and the combined cation exchange–ICP method of AES analysis and MS analysis were carried out for the determination of rare earth elements. Both techniques are within the requirements needed for garnet minerals. The determination of rare‐earth elements in these minerals, which contain other elements as major contribution and trace distribution of rare‐earth elements, shows that ICP applied under the proper working condition lives up to the expectations. Major element analysis gives the formula of garnet of Manavalakurichi (MK) as (FeCaMg)2.79Al2.07Si3.05O12 approximated to Fe3Al2Si3O12, hence of almandine-type garnet. The enrichment of heavy lanthanides compared to the light lanthanides indicates that these lanthanides occupy the coordinaton site of Fe2+ by replacement. Both techniques are excellent in determining the very low concentration of lanthanides in geological materials, specifically garnet.  相似文献   

20.
Moscow University Chemistry Bulletin - A new approach to determine additions of chromium and study its distribution in the bulk and on the surface of SnO2-based nanocrystalline semiconductor...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号