首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(18):3383-3391
Abstract

This paper developed a multivariate method of analysis of quercetin in Ginkgo biloba leaf extracts, based on reflectance NIR measurements and partial least squares regression. In order to give a better correlation with the results obtained by HPLC, multiplicative scatter correction (MSC) was utilized to correct scattering effect and interval partial least squares (iPLS) to select optimum wavelength region. In general, good calibration statistics were obtained for the prediction of quercetin content, as demonstrated by some figures of merit, namely linearity, repeatability, and accuracy. And the iPLS model was more reliable than the full model.  相似文献   

2.
Changeable size moving window partial least squares (CSMWPLS) and searching combination moving window partial least squares (SCMWPLS) are proposed to search for an optimized spectral interval and an optimized combination of spectral regions from informative regions obtained by a previously proposed spectral interval selection method, moving window partial least squares (MWPLSR) [Anal. Chem. 74 (2002) 3555]. The utilization of informative regions aims to construct better PLS models than those based on the whole spectral points. The purpose of CSMWPLS and SCMWPLS is to optimize the informative regions and their combination to further improve the prediction ability of the PLS models. The results of their application to an open-path (OP)/FT-IR spectra data set show that the proposed methods, especially SCMWPLS can find out an optimized combination, with which one can improve, often significantly, the performance of the corresponding PLS model, in terms of low prediction error, root mean square error of prediction (RMSEP) with the reasonable latent variable (LVs) number, comparing with the results obtained using whole spectra or direct combination of informative regions for a compound. Regions consisting of the combinations obtained can easily be explained by the existence of IR absorption bands in those spectral regions.  相似文献   

3.
Near-infrared (NIR) spectra in the region of 5000-4000 cm−1 with a chemometric method called searching combination moving window partial least squares (SCMWPLS) were employed to determine the concentrations of human serum albumin (HSA), γ-globulin, and glucose contained in the control serum IIB (CS IIB) solutions with various concentrations. SCMWPLS is proposed to search for the optimized combinations of informative regions, which are spectral intervals, considered containing useful information for building partial least squares (PLS) models. The informative regions can easily be found by moving window partial least squares regression (MWPLSR) method. PLS calibration models using the regions obtained by SCMWPLS were developed for HSA, γ-globulin, and glucose. These models showed good prediction with the smallest root mean square error of predictions (RMSEP), the relatively small number of PLS factors, and the highest correlation coefficients among the results achieved by using whole region and MWPLSR methods. The RMSEP values of HSA, γ-globulin, and glucose yielded by SCMWPLS were 0.0303, 0.0327, and 0.0195 g/dl, respectively. These results prove that SCMWPLS can be successfully applied to determine simultaneously the concentrations of HSA, γ-globulin, and glucose in complicated biological fluids such as CS IIB solutions by using NIR spectroscopy.  相似文献   

4.
《Analytical letters》2012,45(10):1518-1526
Abstract

This article presents a multivariate method of rapidly determining chlopyrifos residue in white radish, based on near-infrared spectroscopy and partial least squares (PLS) regression. Interval PLS (iPLS) was utilized to select the optimum wave number range. The number of PLS components and the number of intervals were optimized according to root mean square error of prediction (RMSEP) and correlation coefficient (R) in prediction set. The result showed that the iPLS model was more reliable than the full model and that near-infrared spectroscopy with iPLS algorithm could be used successfully to analyze chlorpyrifos residue in white radish.  相似文献   

5.
Ni Xin  Qinghua Meng  Yizhen Li  Yuzhu Hu 《中国化学》2011,29(11):2533-2540
This paper indicates the possibility to use near infrared (NIR) spectral similarity as a rapid method to estimate the quality of Flos Lonicerae. Variable selection together with modelling techniques is utilized to select representative variables that are used to calculate the similarity. NIR is used to build calibration models to predict the bacteriostatic activity of Flos Lonicerae. For the determination of the bacteriostatic activity, the in vitro experiment is used. Models are built for the Gram‐positive bacteria and also for the Gram‐negative bacteria. A genetic algorithm combined with partial least squares regression (GA‐PLS) is used to perform the calibration. The results of GA‐PLS models are compared to interval partial least squares (iPLS) models, full‐spectrum PLS and full‐spectrum principal component regression (PCR) models. Then, the variables in the two GA‐PLS models are combined and then used to calculate the NIR spectral similarity of samples. The similarity based on the characteristic variables and full spectrum is used for evaluating the fingerprints of Flos Lonicerae, respectively. The results show that the combination of variable selection method, modelling techniques and similarity analysis might be a powerful tool for quality control of traditional Chinese medicine (TCM).  相似文献   

6.
Near infrared (NIR) spectrometry was used for the rapid characterization of quality parameters in desi chickpea flour (besan). Partial least square regression, principal component regression (PCR), interval partial least squares (iPLS), and synergy interval partial least squares (siPLS) were used to determine the protein, carbohydrate, fat, and moisture concentrations of besan. Spectra were collected in reflectance mode using a lab-built predispersive filter-based instrument from 700 to 2500?nm. The quality parameters were also determined by standard methods. The root mean square error (RMSE) for the calibration and validation sets was used to evaluate the performance of the models. The correlation coefficients for moisture, fat, protein, and carbohydrates in chickpea flour exceeded 0.96 using PLS and PCR models using the full spectral range. Wavelengths from 2100 to 2345?nm had the lowest RMSE for quality parameters by iPLS. The error was further decreased by 0.41, 0.1, and 1.1% for carbohydrates, fats, and proteins by siPLS. The NIR spectral regions yielding the lowest RMSE of prediction were 1620–2345?nm for carbohydrates, 1180–1590?nm and 1860–2094?nm for fat, and 1700–2345?nm for proteins. The study shows that chickpea flour quality parameters were accurately determined using the optimized wavelengths.  相似文献   

7.
In the present study, boosting has been combined with partial least‐squares discriminant analysis (PLS‐DA) to develop a new pattern recognition method called boosting partial least‐squares discriminant analysis (BPLS‐DA). BPLS‐DA is implemented by firstly constructing a series of PLS‐DA models on the various weighted versions of the original calibration set and then combining the predictions from the constructed PLS‐DA models to obtain the integrative results by weighted majority vote. Coupled with near infrared (NIR) spectroscopy, BPLS‐DA has been applied to discriminate different kinds of tea varieties. As comparisons to BPLS‐DA, the conventional principal component analysis, linear discriminant analysis (LDA), and PLS‐DA have also been investigated. Experimental results have shown that the inter‐variety difference can be accurately and rapidly distinguished via NIR spectroscopy coupled with BPLS‐DA. Moreover, the introduction of boosting drastically enhances the performance of an individual PLS‐DA, and BPLS‐DA is a well‐performed pattern recognition technique superior to LDA. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
Two novel algorithms which employ the idea of stacked generalization or stacked regression, stacked partial least squares (SPLS) and stacked moving‐window partial least squares (SMWPLS) are reported in the present paper. The new algorithms establish parallel, conventional PLS models based on all intervals of a set of spectra to take advantage of the information from the whole spectrum by incorporating parallel models in a way to emphasize intervals highly related to the target property. It is theoretically and experimentally illustrated that the predictive ability of these two stacked methods combining all subsets or intervals of the whole spectrum is never poorer than that of a PLS model based only on the best interval. These two stacking algorithms generate more parsimonious regression models with better predictive power than conventional PLS, and perform best when the spectral information is neither isolated to a single, small region, nor spread uniformly over the response. A simulation data set is employed in this work not only to demonstrate this improvement, but also to demonstrate that stacked regressions have the potential capability of predicting property information from an outlier spectrum in the prediction set. Moisture, oil, protein and starch in Cargill corn samples have been successfully predicted by these new algorithms, as well as hydroxyl number for different instruments of terpolymer samples including and excluding an outlier spectrum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
遗传算法用于偏最小二乘方法建模中的变量筛选   总被引:19,自引:0,他引:19  
利用全局搜索方法-遗传算法(genetic algorithms,GA)对近红外光谱分析中的波长变量进行筛选,再用偏最小二乘方法(patrial least squares,PLS)建立分析校正模型。对两类样品的近红外光谱分析应用实例表明,这种选取变量进行校正的方法,不仅简化、优化了模型,而且增强了所建模型的预测能力,尤其适用于单纯PLS较以校正关联的体系。  相似文献   

10.
New approach for chemometrics algorithm named region orthogonal signal correction (ROSC) has been introduced to improve the predictive ability of PLS models for biomedical components in blood serum developed from their NIR spectra in the 1280-1849 nm region. Firstly, a moving window partial least squares regression (MWPLSR) method was employed to locate the region due to water as a region of interference signals and to find the informative regions of glucose, albumin, cholesterol and triglyceride from NIR spectra of bovine serum samples. Next, a novel chemometrics method named searching combination moving window partial least squares (SCMWPLS) was used to optimize those informative regions. Then, the specific regions that contained the information of water, glucose, albumin, cholesterol and triglyceride were obtained. When an interested component in the bovine serum solution, such as glucose, albumin, cholesterol or triglyceride is being an analyte, the other three interests and water are considered as the interference factors. Thus, new approach for ROSC has employed for each specific region of interference signal to calculate the orthogonal components to the concentrations of analyte that were removed specifically from the NIR spectra of bovine serum in the region of 1280-1849 nm and the highest interference signal for model of analyte will be revealed. The comparison of PLS results for glucose, albumin, cholesterol and triglyceride built by using the whole region of original spectra and those developed by using the optimized regions suggested by SCMWPLS of original spectra, spectra treated OSC for orthogonal components of 1-3 and spectra treated ROSC using selected removing the highest interference signals from the spectra for orthogonal components of 1-3 are reported. It has been found that new approach of ROSC to remove the highest interference signal located by SCMWPLS improves of the performance of PLS modeling, yielding the lower RMSECV and smaller number of PLS factors.  相似文献   

11.
A novel near infrared (NIR) modeling method—Laplacian regularized least squares regression (LapRLSR) was presented, which can take the advantage of many unlabeled spectra to promote the prediction performance of the model even if there are only few calibration samples. Using LapRLSR modeling, NIR spectral analysis was applied to the online monitoring of the concentration of salvia acid B in the column separation of Salvianolate. The results demonstrated that LapRLSR outperformed partial least squares (PLS) significantly, and NIR online analysis was applicable.  相似文献   

12.
In the present work, a fast, relatively cheap, and green analytical strategy to identify and quantify the fraudulent (or voluntary) addition of a drug (alprazolam, the API of Xanax®) to an alcoholic drink of large consumption, namely gin and tonic, was developed using coupling near-infrared spectroscopy (NIR) and chemometrics. The approach used was both qualitative and quantitative as models were built that would allow for highlighting the presence of alprazolam with high accuracy, and to quantify its concentration with, in many cases, an acceptable error. Classification models built using partial least squares discriminant analysis (PLS-DA) allowed for identifying whether a drink was spiked or not with the drug, with a prediction accuracy in the validation phase often higher than 90%. On the other hand, calibration models established through the use of partial least squares (PLS) regression allowed for quantifying the drug added with errors of the order of 2–5 mg/L.  相似文献   

13.
独立分量分析预处理法提高苹果糖度模型预测精度研究   总被引:1,自引:0,他引:1  
邹小波  赵杰文 《分析化学》2006,34(9):1291-1294
为了提高苹果近红外光谱糖度预测模型精度,利用独立分量分析方法(ICA)对苹果近红外光谱进行了预处理,并且建立了糖度的偏最小二乘(PLS)预测模型。结果表明,独立分量分析不但能分离出噪声信号,而且所分离出来的光谱信号也比原始光谱信号光滑。在预处理后的最佳PLS糖度模型校正时的相关系数rc和标准偏差SEC分别为0.9549和0.3361,用于预测时的相关系数rp和标准偏差SEP分别为0.9071和0.4355。与普通的平均处理法的PLS模型相比,其精度有所提高,且模型更加简洁。  相似文献   

14.
Two alternative partial least squares (PLS) methods, averaged PLS and weighted average PLS, are proposed and compared with the classical PLS in terms of root mean square error of prediction (RMSEP) for three real data sets. These methods compute the (weighted) average of PLS models with different complexity. The prediction abilities of the alternative methods are comparable to that of the classical PLS but they do not require to determine how many components should be included in the model. They are also more robust in the sense that the quality of prediction depends less on a good choice of the number of components to be included. In addition, weighted average PLS is also compared with the weighted average part of LOCAL, a published method that also applies weighted average PLS, with however an entirely different weighting scheme.  相似文献   

15.
《Analytical letters》2012,45(9):2073-2083
Abstract

A consensus regression approach based on partial least square (PLS) regression, named as cPLS, for calibrating the NIR data was investigated. In this approach, multiple independent PLS models were developed and integrated into a single consensus model. The utility and merits of the cPLS method were demonstrated by comparing its results with those from a regular PLS method in predicting moisture, oil, protein, and starch contents of corn samples using the NIR spectral data. It was found that cPLS was superior to regular PLS with respect to prediction accuracy and robustness.  相似文献   

16.
成忠  诸爱士 《分析化学》2008,36(6):788-792
针对光谱数据峰宽、局部效应显著、含有噪音、变量个数多及彼此间常存在严重的复共线性等问题,改进和设计一种光谱数据局部校正方法:基于窗口平滑的段式正交信号校正方法,并将之结合偏最小二乘回归,以实现光谱数据的预处理及定量分析。通过NIPALS算法初始化将滤去的正交成分,以近邻分段方式进行逐个波长点的正交信号校正。而后将去噪后的光谱矩阵作为新的自变量阵,通过偏最小二乘回归构建其与性质参变量间的校正模型。通过小麦近红外漫反射光谱数据的应用实验结果表明,本方法正交成分估计稳定,去噪明显,模型的预报性能优于其它方法,PLS成分数减少,模型更加简洁。  相似文献   

17.
Near-infrared spectroscopy (NIR) models built on a particular instrument are often invalid on other instruments due to spectral inconsistencies between the instruments. In the present work, global and robust NIR calibration models were constructed by partial least square (PLS) regression based on hybrid calibration sets, which are composed of both primary and secondary spectra. Three datasets were used as case studies. The first consisted of 72 radix scutellaria samples measured on two NIR spectrometers with known baicalin content. The second was composed of 80 corn samples measured on two instruments with known moisture, oil, and protein concentrations. The third dataset included 279 primary samples of tobacco with known nicotine content and 78 secondary samples of tobacco with known nicotine concentrations. The effect of the number of secondary spectra in the hybrid calibration sets and the methods for selecting secondary spectra on the PLS model performance were investigated by comparing the results obtained from different calibration sets. This study shows that the global and robust calibration models accurately predicted both primary and secondary samples as long as the ratios of the number of primary spectra to the number of secondary spectra were less than 22. The models performance was not influenced by the selection method of the secondary spectra. The hybrid calibration sets included the primary spectral information and also the secondary spectra; information, rendering the constructed global and robust models applicable to both primary and secondary instruments.  相似文献   

18.
用气相色谱分析值为参照,采用近红外透射光谱(NIR)技术采集相应样品的NIR光谱,研究了涂料固化剂中游离甲苯二异氰酸酯(TDI)含量的快速测定分析方法。 并从120个固化剂样品中挑选出109个代表性的样品建模,选择7320~7250 cm-1和8485~8370 cm-1波段区间,用偏最小二乘法(PLS)和完全交互验证方式建立TDI含量的预测模型。 结果表明,固化剂中游离甲苯二异氰酸酯含量和近红外光谱之间存在较好的相关性,其预测模型的校正集均方差(RMSEC)为0.0815,验证集均方差(RMSEP)为0.0715,模型性能良好。 近红外光谱法可快速准确测定游离甲苯二异氰酸酯(TDI)含量,用于固化剂样品快速分析。  相似文献   

19.
In the current study, robust boosting partial least squares (RBPLS) regression has been proposed to model the activities of a series of 4H-1,2,4-triazoles as angiotensin II antagonists. RBPLS works by sequentially employing PLS method to the robustly reweighted versions of the training compounds, and then combing these resulting predictors through weighted median. In PLS modeling, an F-statistic has been introduced to automatically determine the number of PLS components. The results obtained by RBPLS have been compared to those by boosting partial least squares (BPLS) repression and partial least squares (PLS) regression, showing the good performance of RBPLS in improving the QSAR modeling. In addition, the interaction of angiotensin II antagonists is a complex one, including topological, spatial, thermodynamic and electronic effects.  相似文献   

20.
复杂样品近红外光谱定量分析模型的构建方法   总被引:3,自引:0,他引:3  
针对复杂样品近红外光谱分析中校正集的设计问题, 探讨了标准样品参与复杂样品建模的可行性. 通过标准样品和复杂基质样品共同构建的偏最小二乘(PLS)模型, 考察了波段筛选和建模参数对预测结果的影响. 结果表明, 采用PLS方法建立定量模型时, 校正集样品性质应该尽量与预测集样品相似, 当样品的性质相差较大时, 适当增加校正集样品的差异性可使模型具有更强的预测能力. 同时, 波段优选对提高预测结果的准确性具有重要的意义.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号