首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A membrane-assisted solvent extraction (MASE) method is presented for the extraction of several non-ionic organophosphorus chemicals from wastewaters samples followed by LC-MS/MS determination. The method was developed for a variety of chlorinated phosphates (trichloroethyl, tichloropropyl) and non-chlorinated phosphates (triphenyl, tributyl) used as flame retardants and for plasticizers such as triethylhexyl and tris-butoxyethyl phosphate. Parameters such as extracting solvent, sample volume and ionic strength, extraction temperature and time were optimized. The final method provides good quantification limits (1-25 ng L(-1)) and linearity (R2>0.9978). Method precision was also good at high concentrations (5% mean RSD at the 500 ng L(-1) level) but decreased at lower concentrations (20% mean RSD at the 20 ng L(-1) level). MASE yields lower matrix effects than SPE in a successive LC-MS/MS analysis of these compounds, avoiding the need for standard addition for quantification. When applied to wastewater samples comparable results were obtained using either MASE with internal standard calibration or SPE with standard addition.  相似文献   

2.
A fast and sensitive analytical procedure has been developed for the simultaneous separation and determination of alpha-estradiol, beta-estradiol, estriol, estrone and ethynylestradiol and their sulfate, glucuronide and acetate conjugates in river sediments. The procedure includes a microwave-assisted extraction (MAE) with aqueous methanol (25:75, v/v) at 100 degrees C in 10 min, a clean-up on Oasis WAX cartridge and a high-performance liquid chromatography-ion-trap tandem mass spectrometry (HPLC-IT-MS/MS) with electrospray ionization. The recovery for each compounds ranged from 83 to 107% and the repeatability represented as RSDs ranged from 4.9 to 9.6%. The limits of detection (LODs) were down to 1 ng g(-1). The analytical performance of the method was evaluated using determination of free and conjugated estrogens in river sediments.  相似文献   

3.
An improved LC-electrospray ionization MS method was established for four estrogens (17beta-estradiol (E2), estriol (E3), estrone (E1), and ethynyl estradiol (EE)) in environmental water. Almost complete separation of all estrogens was achieved on a phenyl column with methanol/water as the mobile phase. Quantification was achieved in the negative ionization mode using selected ion monitoring. The instrumental detection limits were 20-30 ng/l for the four analytes. In Milli-Q spiked water, the recoveries of the four estrogens were 72-81%, which was similar to those found for river water spiked with the corresponding deuterated estrogens. The detection limits for the four estrogens in river water were 0.1-0.2 ng/l. The method was used to detect residual estrogens in the Tonghui River, which receives water from a municipal sewage treatment plant in Beijing; E1 (1.1 ng/l) and E2 (0.2 ng/l) were detected.  相似文献   

4.
López de Alda MJ  Gil A  Paz E  Barceló D 《The Analyst》2002,127(10):1299-1304
In this study, an analytical procedure for the determination in sediment of the most abundant and/or physiological active estrogens (estradiol, estriol, estrone, ethynyl estradiol, and diethylstilbestrol) and progestogens (progesterone, norethindrone. and levonorgestrel) is described. The procedure includes ultrasonic extraction of the lyophilized sediment, clean-up with octadecylsilica cartridges, and analysis by liquid chromatography-diode array detection-mass spectrometry (LC-DAD-MS). MS detection is performed with an electrospray interface in the positive ion mode for determination of the progestogens and in the negative ion mode for determination of the estrogens. The method was applied to the determination of the target compounds in river sediments from the area of Catalonia. Estrogens and progestogens were found at concentrations usually in the low ng g(-1) range. Estriol and norethindrone were the compounds most frequently found whereas maximum concentrations in all sediment samples were obtained for ethynyl estradiol (22.8 ng g(-1)) and estrone (11.9 ng g(-1)). Detection limits were in the range of 0.04-1.00 ng g(-1). Preliminary conjectures with regards to the environmental behavior and impact of estrogens and progestogens in rivers are made. To the authors' knowledge, this is the first work reporting a detailed method for the analysis of estrogens and progestogens in river sediments and data on the environmental occurrence of both groups of compounds.  相似文献   

5.
Reversed-phase LC-MS/MS is used to determine major estrogenic alkylphenol ethoxylates (APEOs) and their biotransformation products. It allows the simultaneous analysis of eight APEOs, alkylphenoxy carboxylates (APECs) and alkylphenols (APs) in sewage treatment plant (STP) effluents in the same extract after solid-phase enrichment on polymeric Oasis HLB. As precursor ions, [APEO + NH4]+, [APEC - H]- and [AP - H]- were monitored. Instrumental limits of detection (LOD) were 2-600 pg, corresponding to sample concentrations of 0.04-12 ng l(-1), without correction for overall method recoveries. Matrix-induced signal suppression during electrospray ionisation (ESI) and extraction as well as overall method recoveries were assessed and the suitability of deuterated surrogates as internal standards was evaluated.  相似文献   

6.
An analytical method has been developed for the determination of five naturally occurring estrogens (estradiol, estriol, estrone, genistein, daidzein), one synthetic hormone (ethynylestradiol) and three xenoestrogens (4-nonylphenol (NP), 4-tert-octylphenol (4-tert-OP), bisphenol A (BPA)) in coastal marine waters. The procedure includes a solid-phase extraction of approx. fifty litres of water samples on the solid-phase copolymer Oasis HLB followed by a clean-up on silica. Twenty-five percent aliquots were used for the analytical determination of the analytes using high performance liquid chromatography coupled with electrospray-ionisation tandem mass spectrometry (HPLC-ESI-MS/MS). Calculated extraction recoveries between 52 (4-tert-octylphenol) and 91% (nonylphenol) were obtained for the method developed. Matrix interferences occurring during electrospray ionisation were quantified by spiking the extracts prior to the measurements. Method detection limits ranged from 0.02 (estrone) to 1 ng L(-1) (estriol). The method was applied to determine environmental estrogens in coastal waters of the Baltic Sea. The analyses showed the presence of five compounds at levels between 0.10 (estrone) and 17 ng L(-1) (ethynylestradiol).  相似文献   

7.
A sensitive and simple method based on ultrasonication extraction with a hexane/acetone (2:1, v/v) mixture, followed by clean up of the extract by solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) detection, has been developed and validated for the analysis of 20 estrogenic endocrine-disrupting chemicals (EEDCs) including phenolic xenoestrogens, synthetic and natural estrogens in river sediment. After extraction and purification, analytes are derivatised with a BSTFA/TMCS/pyridine (49:1:50, v/v/v) mixture and quantified by GC/MS. The GC/MS method involves switching between electron ionisation (EI) and chemical ionisation (CI); it also switches between selected ion storage and tandem mass spectrometry detection. The applicability of the method has been demonstrated by analysing extracts of French river sediments for which bioanalytical tests (in vitro) had already shown that they were impacted by estrogenic endocrine disrupters. The biological contribution of all the products detected in each sediment extract was compared to the estrogenic activity measured by bioassays.  相似文献   

8.
Even in trace amounts, estrogens such as 17beta-estradiol (E2), estrone (E1), estriol (E3), and 17alpha-ethinyl estradiol (EE2) may have adverse effects on humans and the aquatic ecosystem. Therefore, it is essential to be able to measure trace amounts of steroid estrogens in water. To date, most instruments are not sensitive enough to detect these chemicals in small samples of water. Sensitivity, however, may be improved by using appropriate derivatization reagents to modify the structures of these estrogens so that their ionization efficiency is increased, making them more detectable by liquid chromatography/mass spectrometry (LC/MS). This study uses dansyl chloride, 2-fluoro-1-methylpyridinium p-toluenesulfonate (FMPTS), and pentafluorobenzyl bromide (PFBBr) as derivatization reagents to react with the phenolic estrogens to make them more detectable in water. We also test how environmental matrices (wastewater effluent, river water, and drinking water) influence the detectability of these estrogens. Both qualitative and semi-quantitative comparisons of these derivatization methods were made. We found that dansyl chloride derivatives created signal intensities one or two orders of magnitude greater than those normally found in underivatized estrogen standards. The signals derived by FMPTS were analyte-dependent, and the products derived from E1, E2, and EE2 produced 2.19 to 12.1 times the signal intensity of underivatized E1, E2, and EE2. The product derived from E3 produced weaker signals than that produced by underivatized E3. The PFBBr derivatives produced signals that were as much as 5.8 times those found in the underivatized estrogens. When these derivatization methods were applied to river water, drinking water and effluents from a sewage treatment plant (STP), the different matrices were found to significantly suppress the signals if we used electrospray ionization, though this influence became less significant if we used atmospheric pressure chemical ionization. This study suggests that PFBBr derivatization can best be used for the detection of these estrogens in complex environmental matrices such as river water and STP effluents and that the dansyl chloride derivatization is best used for clean samples such as drinking water.  相似文献   

9.
We have developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) system capable of achieving better than 2% accuracy, routinely over a wide concentration range of 1800 ng mL-1. We demonstrate that the necessary high precision, high accuracy and rapid analysis can be achieved using LC-MS/MS technology. Automated nanoelectrospray ionisation tandem mass spectrometry (nanoESI-MS/MS) technology can be employed to eliminate the chromatographic step completely. In this paper, nanoESI-MS/MS is evaluated and compared directly with LC-MS/MS for the quantitative analysis of two-test analytes, amitriptyline (ATT) and 5-methoxytryptamine (5-MTT), in aqueous/organic mixture. Calibration curves were found to be linear over a wide concentration range of 1800 ng mL-1 for both analytes using LC-MS/MS. Using nanoESI-MS/MS ATT gave a linear response while 5-MTT gave a non-linear response using nanoESI-MS/MS over the same concentration range as in LC-MS/MS. Accuracy and precision values of quality control samples (QCs) at four concentration levels were analysed in replicates of six at each level using 5-MTT and ATT as test analytes for both techniques. The LC-MS/MS system was capable of achieving accuracy levels of 99.50101.96% for ATT and 100.17100.40% for 5-MTT. Accuracy levels using nanoESI-MS/MS were not comparable to LC-MS/MS, they ranged from 90.09100.18% for ATT and 95.95113.55% for 5-MTT. The precision values obtained for nanoESI-MS/MS were in good agreement with those obtained by LC-MS/MS.  相似文献   

10.
An analytical method is presented which permits trace level determination of 17alpha-ethynylestradiol (EE2), 17beta-estradiol (E2), and estrone (E1). Using this method, the estrogenic steroids were analyzed in drinking water, surface water, and wastewater (sewage influents and effluents) at concentrations down to 0.1 ng/L. Sample volumes between 100 and 500 mL are concentrated using automated solid-phase extraction. Analysis is performed by liquid chromatography with detection by tandem mass spectrometry. Applying simple clean-up procedures and internal standard calibration, recovery losses resulting from matrix-dependent ion suppression during electrospray ionization could be compensated for all of the investigated compounds. Recoveries around 100% were obtained for all analytes after correction using the internal standards. Limits of quantification (LOQ) were between 0.1 and 0.4 ng/L for purified sewage, surface, ground, and drinking water and between 1 and 2 ng/L in the case of raw sewage. Water treatment by wastewater treatment plants (WWTPs) or by a surface water treatment plant affected the removal of all estrogenic steroids. Thus, E1, E2, and EE2 were removed in the municipal WWTPs to the extent of 93%, 93%, and 80%, respectively. In the effluents of the WWTP in Ruhleben (Berlin, Germany), E1, E2, and EE2 were detected at the low ng/L level. E2 and EE2 were, however, not present in the Berlin surface water above the LOQ (0.2 ng/L). E1 was the only compound that could be detected in surface water samples. After additional surface water treatment it was still detectable but only at trace-level concentrations with a mean value of 0.16 ng/L.  相似文献   

11.
In this study, the simultaneous extraction of estrone (E1), 17β-estradiol (E2), estriol (E3), ethinylestradiol (EE2), and their glucuronated and sulfated metabolites in milk was optimized using solid-phase extraction (SPE). The aim of this research was to analyze estrogens and their conjugated metabolites by liquid chromatography with tandem mass spectrometry (LC–MS/MS) in a single run, without the need to perform enzymatic cleavage and derivatization. Two SPE cartridges in tandem were used, consisting of sorbents based on the hydrophilic–lipophilic balance and amine-functionalized packing materials. To monitor analyte loss at every step of the SPE procedure 14C-labeled E2 was spiked into the milk sample and the radioactivity was monitored at all stages of the SPE. In addition, non-radiolabeled standards of estrogens and metabolites were used to optimize solvent systems for the SPE and LC–MS/MS. The optimized method described in this paper can achieve recoveries ranging from 72% to 117% for the free estrogens (E1, E2, E3, and EE2), and 62% to 112% for seven conjugated metabolites. The three doubly conjugated, highly polar metabolites included in this study gave lower recoveries (≤43%) due to poor retention in SPE. Finally, commercial milk samples were analyzed for the presence of estrogens and their conjugated metabolites. Estrone (concentration range: 23–67 ng/L) was found to be the major free estrogen present in all milk samples. Estradiol was consistently observed in milk, but the concentrations were below the limit of detection (LOD of 10 ng/L), and no estriol and ethinylestradiol were detected. Several conjugated estrogen metabolites were identified, 17β-estradiol-3-glucuronide (71–289 ng/L), estrone-3-sulfate (60–240 ng/L), 17β-estradiol-3,17β-sulfate (<LOD to 30 ng/L), and estrone-3-glucuronide (<LOQ of 25 ng/L). This method proved efficient in the simultaneous analysis of estrogens and their metabolites in milk.  相似文献   

12.
The potential of the direct coupling of solid-phase extraction (SPE) with mass spectrometry (MS) for the analysis of biological samples is demonstrated. For SPE a cartridge exchanger is used and the eluate is directly introduced into the mass spectrometer. This system has been investigated for the determination of clenbuterol in urine. With mixed-mode cartridges, a considerable ion suppression has been obtained. The mass spectrum at the elution time of clenbuterol is dominated by that of creatinine and adduct formation of clenbuterol and creatinine has been observed. The whole procedure including injection of 1 ml urine, washing and desorption has been developed with cartridges containing 8-microm C18-bonded silica. If only a single MS step is used, the selectivity and, therefore, the sensitivity are insufficient. The detection limit is about 100 ng/ml. However, with atmospheric pressure chemical ionisation and the tandem MS mode the detection limit has been decreased to about 2 ng/ml and the ion suppression is only about 10%. For the electrospray ionisation the detection limit is about 10-times higher and the ion suppression is less favourable. The repeatability for the SPE-MS-MS procedure was 6.5% at 10 ng/ml (n=5) and the difference between the response factors at 10 ng/ml and 100 ng/ml was only 2.5%. The MS behaviour of clenbuterol and the matrix under the present conditions is discussed.  相似文献   

13.
A multi-residue analytical method has been developed for the determination of various classes of selected endocrine disruptors. This method allows the simultaneous extraction and quantification of different estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol diacetate, estrone-3-sulfate, ethynyl estradiol and diethylstilbestrol), pesticides (atrazine, simazine, desethylatrazine, isoproturon and diuron), and bisphenol A in natural waters. In the method developed, 500 ml of water are preconcentrated on LiChrolut RP-18 cartridges. Further analysis is carried out by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionisation (APCI) in the positive ion mode for determination of pesticides and electrospray in the negative ionisation mode for determination of estrogens and bisphenol A. Recoveries for most compounds were between 90 and 119%, except for bisphenol A (81%) and diethylstilbestrol (70%), with relative standard deviations below 20%. Limits of detection ranged between 2 and 15 ng/l. The method was used to study the occurrence of the selected pollutants in surface and groundwater used for abstraction of drinking water in a waterworks and to evaluate the removal efficiency of the different water treatments applied. Water samples from the river, the aquifer, and after each treatment stage (sand filtration, ozonation, activated carbon filtration and post-chlorination) were taken monthly from February to August of 2002. The presence in river water of atrazine, simazine, diuron and bisphenol A were relatively frequent at concentrations usually below 0.1 microg/l. Lower levels, below 0.02 microg/l, were usual for isoproturon. Estrone-3-sulfate and estrone were detected occasionally in the river. Most of the compounds were completely removed during the water treatment, especially after activated carbon filtration.  相似文献   

14.
Part of a comprehensive study on the comparison of different extraction methods, GC-MS(/MS) and LC-MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC-MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL(-1)) into the LC-MS/MS system. Linearity, r(2) of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r(2)> or =0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL(-1), corresponding with pesticide concentrations in soya bean extract of 2 or 5-200 microg kg(-1). Instrument LOD values generally were 0.1 or 0.25 ng mL(-1). Matrix effects were negligible for approximately 90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 microg kg(-1), six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 microg kg(-1) and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70-120%) and RSD (< or =20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.  相似文献   

15.
A multi-residue method using liquid chromatography coupled to triple quadrupole tandem mass spectrometry (LC-MS/MS), associated with solid-phase extraction (SPE), was developed for the determination of 21 pesticides in water samples. The compounds investigated are used for the maintenance of golf courses and ordinarily measured by gas chromatography-mass spectrometry (GC-MS). Electrospray ionisation (ESI) was applied to all compounds, and LC and MS conditions were optimised to measure them under SRM mode. This method showed excellent linearity ranges for all pesticides, with correlation coefficients greater than 0.996. Two kinds of extraction cartridges, namely, styrene divinylbenzene polymer (Sep-Pak PS-2) and divinylbenzene-N-vinylpyrrolidone copolymer (Oasis HLB), were tested and the extraction conditions were optimised. All the pesticides were determined using acetonitrile and ethyl acetate as eluents in both cartridges, and good recoveries (>77%) and repeatability with low relative standard deviations (RSDs, <12%) were achieved from ultra-pure water. In addition, satisfactory recoveries (>76%) and low intra-day and inter-day RSDs (<15%) of all pesticides were also obtained with the Sep-Pak PS-2 cartridge when using river water. The method limits of detection (LODs) ranged between 0.068 (diazinon) and 3.9 (triclopyrbutoxyethyl)?ng?L?1. The analytical method was successfully applied for the determination of pesticides in surface river water.  相似文献   

16.
A sensitive method for the simultaneous analysis of five estrogens in sewage sludge was developed. The extraction and purification steps were optimized and the matrix effects were evaluated. The chromatographic gradient was optimized to limit matrix effects and the analysis step was performed by LC-MS/MS. The method consists of an ASE® extraction with a solvent mixture water/methanol 80/20?v/v at 100?°C followed by two consecutive purifications on Oasis HLB® and florisil cartridges. A thorough validation of the developed method was performed. Recoveries determined at two different spiking levels ranged between 86% and 126% depending on the molecule. Repeatability was evaluated on five replicates of the same sludge sample spiked at two different levels and measuring native estrogens in triplicates of 12 sludge samples. Relative standard deviations obtained a range of between 2% and 27%. Reproducibility was also studied by analyzing the same sludge on four different days: the relative standard deviation ranged between 14% and 20% for E1, βE2 and E3. For αE2, poor reproducibility (68%) was observed but it was linked to the very low quantity of αE2 present in the sludge sample and not to the method performance. The specificity of the method was evaluated on various sludge samples spiked at different spiking levels showing that performances of the proposed method were not modified by matrix effects. Finally, sensitivity of the method was evaluated taking into account both instrumental sensitivity and matrices; the estimated limits of quantification were around 1 ng/g for E1, between 2 and 4 ng/g for αE2, βE2, and E3 and around 5 ng/g for EE2.  相似文献   

17.
液相色谱-串联质谱法检测动物肝肾组织中3种雌激素   总被引:1,自引:0,他引:1  
康海宁  欧阳姗  林黎  岳振峰  沈金灿 《色谱》2012,30(10):986-990
建立了动物肝、肾组织中雌酮、17β-雌二醇、雌三醇药物残留检测的液相色谱-串联质谱(LC-MS/MS)分析方法。样品以叔丁基甲醚提取,于45 ℃下氮吹至干,用正己烷-二氯甲烷(6:4, v/v)重新溶解,过硅胶固相萃取小柱净化,氮吹至干,用1 mL乙腈-水(7:3, v/v)定容后测定,用Poroshell 120 EC-C18柱分离,以乙腈和水作为流动相进行梯度洗脱,电喷雾负离子模式电离,多反应监测模式检测,外标法定量。该方法对3种雌激素的线性范围均为1.0~20.0 μg/kg,相关系数大于0.99,定量限为1.0 μg/kg。在不同基质中,1.0、2.0、10.0 μg/kg 3个添加水平的平均回收率范围为70.2%~114%,相对标准偏差范围为2.01%~14.5%。该方法具有快速简便、净化效果好、灵敏度高等特点,适用于动物肝、肾组织中雌激素的检测。  相似文献   

18.
液相色谱-串联质谱法测定尿液中的内源性类固醇激素   总被引:2,自引:0,他引:2  
王萌烨  向平  严慧  沈保华  沈敏 《色谱》2008,26(1):10-14
建立了液相色谱-串联质谱(LC-MS/MS)测定尿液中的内源性类固醇激素的方法。尿样经葡萄糖醛酸甙酶酶解后进行液-液提取,以甲醇-0.1%甲酸缓冲液(含0.02 mol/L乙酸铵)(体积比为68:32)为流动相,采用Cosmosil C18色谱柱分离,并以三重四极杆串联质谱多反应监测扫描方式对尿样中的脱氢表雄酮(DHEA)、睾酮、表睾酮、雄酮和苯胆烷醇酮等5种激素进行检测。方法的最低检出限为0.01~10 ng/mL,平均回收率为96.7%~106.5%,日内和日间相对标准偏差(RSD)分别小于7%和11%。应用所建立的方法测定了健康志愿者口服DHEA后尿液中内源性类固醇激素的变化情况,结果表明该方法样品处理简便,色谱分离完全,结果准确可靠,可替代气相色谱-质谱法用于体液中内源性类固醇激素兴奋剂的常规分析。  相似文献   

19.
An analytical method is presented enabling the determination of nine neutral pharmaceuticals in groundwater, and for most of the compounds, in rivers and wastewater down to the lower ng/l range. The analytes belong to different medicinal groups such as antiphlogistics, psychiatric drugs and antidiabetics. Samples are enriched using solid-phase extraction (SPE) with RP-C18ec material. Analysis is performed by liquid chromatography with detection by electrospray tandem MS. Mean recoveries generally exceed 80% in groundwater, and the quantification limits are down to 50 ng/l in wastewater and down to 10 ng/l in groundwater. Losses were observed to occur either from ion suppression in the electrospray ionisation or SPE. Losses for all compounds could not be compensated for by the surrogate standard dihydrocarbamazepine. In raw municipal wastewater, concentration levels were detected for caffeine up to 147 microg/l and for propyphenazone up to 1.3 microg/l.  相似文献   

20.
In this study we present a high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method which has been elaborated to analyse steroid hormones, hormone conjugates, oral contraceptives and macrolide antibiotics unchanged in unfiltered influents and effluents of sewage treatment plants (STPs). HPLC separation of the steroid hormones was achieved in 35 min, as well as those of the antibiotics. The analytes were extracted by solid-phase extraction, followed by clean-up using size exclusion chromatography (SEC). For the final quantification HPLC/MS/MS was used. The two ionisation modes, electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI), in HPLC/MS/MS were compared for the analysis of steroid hormones. For quantitative results drastic matrix effects were observed while using ESI. These effects were less pronounced while using APCI. These pitfalls were additionally reduced by clean-up using SEC as well as isotope dilution. Additionally, two multiple reaction monitoring (MRM) transitions per compound were used to prevent false positive results. Recovery experiments with spiked tap water with concentrations varying from 1 to 1000 ng/L gave constant recovery rates: The recovery rates for the hormones and conjugates ranged from 58 to 107%, those of the contraceptives ranged from 83 to 109%. The relative standard deviation was found to be 7 to 24% and the limits of detection were 0.1 to 4.5 ng/L. The recovery rates of the macrolide antibiotics ranged from 76 to 103%, while the relative standard deviation was found to be 7 to 14% and the limits of detection ranged from 0.6 to 1.8 ng/L. The maximum concentrations found in influents of a STP was 470 ng/L for estriol and 1200 ng/L for erythromycin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号