共查询到20条相似文献,搜索用时 0 毫秒
1.
For weakly absorbing materials, image contrast can be enhanced by
phase contrast in formation. The effectiveness of the in-line phase
contrast technique relies on its ability to record intensity data
which contain information on the x-ray's phase shift. Four kinds of
approaches to the relationship between intensity distribution and
phase shift are reviewed and discussed. A micro-focal x-ray source
with high geometrical magnification is used to acquire phase
contrast images. A great improvement on image quality is shown and
geometrical parameters are modified for comparison between different
imaging positions. 相似文献
2.
We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method. 相似文献
3.
4.
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified. 相似文献
5.
In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging. 相似文献
6.
利用微聚焦管硬x射线光源进行同轴位相衬度成像实验,所用的光源聚焦尺寸最小可达0.5μm.根据微聚焦硬x射线管的光学传递函数,对光源尺寸、相干长度等因素对成像分辨率的影响进行了分析.对新鲜的未经任何处理的生物样品进行了位相衬度成像,分辨率在10μm左右,并和吸收衬度成像进行了对比.实验结果表明利用微聚焦管作为硬x射线光源,多色硬x射线位相衬度成像可以得到比吸收衬度成像高得多的分辨率.
关键词:
位相衬度成像
微聚焦管x射线源
吸收衬度成像
光学传递函数 相似文献
7.
8.
通过对具有二维高斯型相位分布特征物体的X射线同轴相衬成像技术进行理论分析,提出了一种基于图像信噪比的成像系统优化设计方法。采用数值模拟的方式分别对亚微焦点源、激光驱动微焦点源和同步辐射源三种X射线源下的成像系统进行了优化设计,结果表明:相对于最大化衬度的系统优化设计方法,信噪比优化设计方法在较小降低衬度的前提下,可以较好地改善图像信噪比并得到更为合理的成像距离。 相似文献
9.
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating 下载免费PDF全文
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorptionbased imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 相似文献
10.
在所有的相衬成像方法中,X射线同轴轮廓成像由于光路简单、不需要任何光学元件而备受关注.其缺点是无法直接消除散射的影响,从而限制了它在生物医学等领域中的应用.利用数字模拟方法研究了引入散射前后轮廓像的质量随样品到探测器距离的变化情况.模拟结果表明直接轮廓成像存在一个最佳成像距离,因而无法通过改变样品到探测器距离来减小散射的影响.利用定量相衬成像不受成像距离限制的特点,研究了远距离成像时散射的影响.结果表明,样品到探测器的距离增大到一个临界值时,散射对重构像的影响可降到一个极值,此时成像质量得到了明显改善.
关键词:
散射
X射线同轴轮廓成像
定量相衬成像 相似文献
11.
YU Bin PENG Xiang TIAN Jindong NIU Hanben DIAO Luhong & LI Hua . Key Laboratory of Optoelectronic Devices Systems of Ministry of Education Institute of Optoelec- tronics Shenzhen University Shenzhen China . State Key Laboratory of Precision Measuring Technology Instruments Tianjin University Tianjin China . Key Laboratory of Intelligent Information Processing Institute of Computing Technology Chinese Academy of Sciences Beijing China 《中国科学G辑(英文版)》2005,48(4):450-458
X-ray phase contrast imaging (XPCI) is a novel method that exploits the phase shift for the incident X-ray to form an image. For light elements such as carbon, hydrogen and oxygen, the phase-shift term can be up to 1000 times greater than the absorption term in the hard X-ray energy region. So XPCI has attracted much attention in recent years. Various methods for XPCI have been proposed and demonstrated on synchrotron devices and other X-ray sources[1―13], particularly the in-line metho… 相似文献
12.
针对常规内爆背光照相中存在的光源均匀性差、 靶丸图像烧蚀层与气体层界面不清晰、 瞄准精度差等关键问题设计了新型的背光照相靶. 在神光II大型激光装置上采用阵列点光源结合相衬成像的方式获取了清晰的靶丸烧蚀层与气体层界面信息, 同时具备光源均匀性好, 成像视场大的优点; 采用诊断狭缝限光的方式大大提高了瞄准精度使得整体图像质量优于常规靶设计. 实验结果表明, 激光驱动等离子体产生的点光源结合相衬成像方法在精密物理诊断中具有重要的作用, 可以广泛应用于惯性约束聚变以及高能量密度物理研究.
关键词:
惯性约束聚变
背光照相
针孔点背光
相衬成像 相似文献
13.
14.
15.
16.
17.
针对在普通实验室和医院实现40—100keVX射线相衬成像的需求,考虑到成像系统参数、X射线源空间相干特性及光栅衍射效率,设计出硅基相位光栅结构参数.利用我们已发展的光助电化学刻蚀技术研制出直径为5英寸的相位光栅,其空间周期为5.6μm,线宽为2.8μm,深度为40—70μm.在理论分析的基础上,通过提高硅片两端有效工作电压和修正Lehmann电流密度公式,解决了实际刻蚀过程中出现的钻蚀问题.由实验结果可知,本方案对制作大面积高精度相位光栅十分有效。 相似文献
18.
随着惯性约束核聚变(ICF)研究的逐步深入,尤其是氘氚(DT)燃料层球壳梯度掺杂的广泛应用,对轻物质界面的诊断需求日益增长.在北京同步辐射形貌成像站的微米CT机上利用类同轴相衬成像方法获取了三层球壳靶丸的相衬图像,最佳空间分辨率达到了2μupm,衬度达到12%;通过分析边缘增强函数和衬度传递函数之间的关系,总结出一套完整的类同轴相衬成像方法,同时将相衬成像结果与吸收成像结果对比.实验结果表明,X射线相衬成像在轻物质界面的分辨中具有明显的优势,能够广泛应用于ICF研究、医学断层扫描CT装置和生物结构等前沿科学领域. 相似文献
19.
20.
Microbubbles containing gadolinium as contrast agents for both phase contrast and magnetic resonance imaging 下载免费PDF全文
Rongbiao Tang Fuhua Yan Guo-Yuan Yang Ke-Min Chen 《Journal of synchrotron radiation》2018,25(2):560-564
Portal vein imaging is an important method for investigating portal venous disorders. However, the diagnostic requirements are not usually satisfied when using single imaging techniques. Diagnostic accuracy can be improved by combining different imaging techniques. Contrast agents that can be used for combined imaging modalities are needed. In this study, the feasibility of using microbubbles containing gadolinium (MCG) as contrast agents for both phase contrast imaging (PCI) and magnetic resonance imaging (MRI) are investigated. MCG were made by encapsulating sulfur hexafluoride (SF6) gas with gadolinium and lyophilized powder. Absorption contrast imaging (ACI) and PCI of MCG were performed and compared in vitro. MCG were injected into the main portal trunk of living rats. PCI and MRI were performed at 2 min and 10 min after MCG injection, respectively. PCI exploited the differences in the refractive index and visibly showed the MCG, which were not detectable by ACI. PCI could facilitate clear revelation of the MCG‐infused portal veins. The diameter of the portal veins could be determined by the largest MCG in the same portal vein. The minimum diameter of clearly detected portal veins was about 300 µm by MRI. These results indicate that MCG could enhance both PCI and MRI for imaging portal veins. The detection sensitivity of PCI and MRI could compensate for each other when using MCG contrast agents for animals. 相似文献