首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Zhang B  Pan X  Venne L  Dunnum S  McMurry ST  Cobb GP  Anderson TA 《Talanta》2008,75(4):1055-1060
A reliable, sensitive, and reproducible method was developed for quantitative determination of nine new generation pesticides currently used in cotton agriculture. Injector temperature significantly affected analyte response as indicated by electron capture detector (ECD) chromatograms. A majority of the analytes had an enhanced response at injector temperatures between 240 and 260 degrees C, especially analytes such as acephate that overall had a poor response on the ECD. The method detection limits (MDLs) were 0.13, 0.05, 0.29, 0.35, 0.08, 0.10, 0.32, 0.05, and 0.59 ng/mL for acephate, trifuralin, malathion, thiamethozam, pendimethalin, DEF6, acetamiprid, brifenthrin, and lambda-cyhalothrin. This study provides a precision (0.17-13.1%), accuracy (recoveries=88-107%) and good reproducible method for the analytes of interest. At relatively high concentrations, only lambda-cyhalothrin was unstable at room temperature (20-25 degrees C) and 4 degrees C over 10 days. At relatively low concentrations, acephate and acetamiprid were also unstable regardless of temperature. After 10 days storage at room temperature, 30-40% degradation of lambda-cyhalothrin was observed. It is recommended that acephate, acetamiprid, and lambda-cyhalothrin be stored at -20 degrees C or analyzed immediately after extraction.  相似文献   

2.
This study evaluates concentration capability of headspace sorptive extraction (HSSE) and the influence of sampling conditions on HSSE recovery of an analyte. A standard mixture in water of six high-to-medium volatility analytes (isobutyl methyl ketone, 3-hexanol, isoamyl acetate, 1,8-cineole, linalool and carvone) was used to sample the headspace by HSSE with stir bars coated with different polydimethylsiloxane (PDMS) volumes (20, 40, 55 and 110 microL, respectively), headspace vial volumes (8, 21.2, 40, 250 and 1000 mL), sampling temperatures (25, 50 and 75 degrees C) and sampling times (30, 60 and 120 min, and 4, 8 and 16 h). The concentration factors (CFs) of HSSE versus static headspace (S-HS) were also determined. Analytes sampled by the PDMS stir bars were recovered by thermal desorption (TDS) and analysed by capillary GC-MS. This study demonstrates how analyte recovery depends on its physico-chemical characteristics and affinity for PDMS (octanol-water partition coefficients), sampling temperatures (50 degrees C) and times (60 min), the volumes of headspace (40 mL) and of PDMS (in particular, for high volatility analytes). HSSE is also shown to be very effective for trace analysis. The HSSE CFs calculated versus S-HS with a 1000 mL headspace volumes at 25 degrees C during 4 h sampling ranged between 10(3) and 10(4) times for all analytes investigated while the limits of quantitation determined under the same conditions were in the nmol/L range.  相似文献   

3.
An automated method based on the on-line coupling of anion-exchange solid-phase extraction (SPE) and cation-exchange liquid chromatography followed by post-column derivatization and fluorescence detection has been developed for the trace level determination of glyphosate and its primary conversion product aminomethyl phosphonic acid (AMPA) in water. PRP-X100 poly(styrene-divinylbenzene)-trimethylammonium anion-exchange cartridges (20 x 2 mm, 10 microm) were selected for the SPE of glyphosate and AMPA. The ionic compounds present in the samples strongly influenced the extraction of both analytes; however, when an on-line ion-exchange clean-up step was introduced before sample SPE, the problem was largely solved. By processing 100-ml samples detection limits better than 0.02 microg/l for glyphosate and 0.1 microg/l for AMPA were achieved in river water. Both analytes were unstable in solution and the approach of storing samples on the PRP-X100 SPE cartridges was evaluated for a period of 1 month under three different storage conditions (deep freeze, refrigeration and 20 degrees C).  相似文献   

4.
A new doping control screening method has been developed, for the analysis of doping agents in human urine, using HPLC/orbitrap with in-source collision-induced dissociation and atmospheric pressure chemical ionization. The developed method allows the detection of 29 compounds, including agents with antiestrogenic activity, beta(2) agonists, exogenous anabolic steroids, and other anabolic agents. The mass accuracy of this method is better at 2 ppm using an external reference. The detection limit for all compounds tested was better than 100 pg/ml. The recoveries of most analytes were above 70%. The measured median repeatability values for doping agents included in the method at concentrations of 1 and 10 ng/ml were 21 and 17%, respectively. The relative standard deviation (RSD) of the intraday precision (n = 6) ranged from RSD = 16-22%, whereas the interday precision (n = 18), ranged from RSD = 17-26%, depending on the solute concentration investigated.  相似文献   

5.
Factorial design (FD) was applied in order to develop an optimised method for the detection of chemical warfare (CW) agent simulant compounds on Porapak Q. Application of FD allowed study of the adsorption/desorption mechanism of analytes. Di(propylene glycol) monomethyl ether (DPM) and methyl salicylate (MS) were selected for study as both compounds are employed in agent simulation trials but are currently analysed by different methods. An analytical method for simultaneous determination of both compounds was developed using solvent desorption. The optimised method identified non-polar interactions as the primary adsorption/desorption mechanism. Steel tubes were shown to be more suited for sampling of simulants, due to lower variability in recovery compared to glass tubes. Atmospheric detection limits for both simulants were estimated to be 0.2 mg m(-3) allowing the trace analysis of these compounds by gas chromatography with flame ionisation detection (GC-FID).  相似文献   

6.
The stability of methylmercury and inorganic mercury retained on yeast-silica gel microcolumns was established and compared with the stability of these species in solution. Yeast-silica gel columns with the retained analytes were stored for two months at three different temperatures: -20 degrees C, 4 degrees C and room temperature. At regular time intervals, both mercury species were eluted and quantified by cold vapor atomic absorption spectrometry (CVAAS). Methylmercury was found stable in the columns over the two-month period at the three different temperatures tested while the concentration of inorganic mercury decreased after one week's storage even at -20 degrees C. These results are of great interest since the use of these microcolumns allows the preconcentration and storage of mercury species until analysis, thus saving laboratory space and avoiding the problems associated with maintaining species integrity in aqueous solution.  相似文献   

7.
A headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC/MS) method was developed using experimental designs to quantify the flavor of commercial Cheddar cheese and enzyme-modified Cheddar cheese (EMCC). Seven target compounds (dimethyl disulfide, hexanal, hexanol, 2-heptanone, ethyl hexanoate, heptanoic acid, delta-decalactone) representative of different chemical families frequently present in Cheddar cheese were selected for this study. Three types of SPME fibres were tested: Carboxen/polydimethylsiloxane (CAR/PDMS), polyacrylate (PA) and Carbowax/divinylbenzene (CW/DVB). NaCl concentration and temperature, as well as extraction time were tested for their effect on the HS-SPME process. Two series of two-level full factorial designs were carried out for each fibre to determine the factors which best support the extraction of target flavors. Therefore, central composite designs (CCDs) were performed and response surface models were derived. Optimal extraction conditions for all selected compounds, including internal standards, were: 50 min at 55 degrees C in 3M NaCl for CAR/PDMS, 64 min at 62 degrees C in 6M NaCl for PA, and 37 min at 67 degrees C in 6M NaCl for CW/DVB. Given its superior sensitivity, CAR/PDMS fibre was selected to evaluate the target analytes in commercial Cheddar cheese and EMCC. With this fibre, calibration curves were linear for all targeted compounds (from 0.5 to 6 microg g(-1)), except for heptanoic acid which only showed a linear response with PA fibres. Detection limits ranged from 0.3 to 1.6 microg g(-1) and quantification limits from 0.8 to 3.6 microg g(-1). The mean repeatability value for all flavor compounds was 8.8%. The method accuracy is satisfactory with recoveries ranging from 97 to 109%. Six of the targeted flavors were detected in commercial Cheddar cheese and EMCC.  相似文献   

8.
Sol-gel coating containing highly polar cyanopropyl and nonpolar poly(dimethylsiloxane) components (sol-gel CN-PDMS coating) was developed for capillary microextraction (CME). The sol-gel chemistry provided an efficient means to immobilize the CN-PDMS coating by establishing chemical anchorage between the coating and the fused silica capillary inner surface. This chemical bond provided excellent thermal and solvent stability to the created sol-gel coating. For the extraction of polar and nonpolar analytes, the upper allowable conditioning temperatures were 330 degrees C and 350 degrees C, respectively. To our knowledge, this is the first time when a CN-PDMS thick coating survived such a high operation temperature. The prepared sol-gel CN-PDMS coating provided effective extraction of polar and nonpolar analytes simultaneously from aqueous samples. The cyanopropyl moiety in sol-gel CN-PDMS coatings provided effective extraction of highly polar analytes such as free fatty acids, alcohols, and phenols without requiring derivatization, pH adjustment or salting out procedures. The PDMS moiety, on the other hand, provided efficient extraction of nonpolar analytes. The extraction properties of the sol-gel CN-PDMS coatings can be fine tuned via manipulation of relative proportions of 3-cyanopropyltriethoxysilane and hydroxy-terminated PDMS in the sol solution used to create the coatings. Detection limits of nanogram/liter (ng/L) were achieved for both highly polar and nonpolar analytes directly extracted from aqueous media using sol-gel CN-PDMS coated microextraction capillaries followed by GC analysis.  相似文献   

9.
A drying cartridge was used and optimized for the in-line elimination of water from the desorption eluent in on-line solid phase extraction–gas chromatography (SPE–GC). The cartridge is essentially a small stainless-steel precolumn packed with a drying agent which can be regenerated by simultaneous heating and purging with a moisture-free gas. The drying cartridge was mounted on an additional valve instead of between the SPE–GC transfer valve and the on-column injector to enable regeneration of the cartridge during the GC run and, thus, to increase sample throughput. Three drying agents were tested, viz. sodium sulfate, silica, and molecular sieves. Although molecular sieves have the highest capacity, silica was preferred because of practical considerations. Large-volume injections were performed through the in-line drying cartridge using a mixture of 23 microcontaminants ranging widely in polarity and volatility. Four solvents were tested. With pentane and hexane, the more polar analytes were retained by the drying cartridge. Ethyl acetate and methyl acetate gave much better (and closely similar) recoveries for all analytes. Because water elimination on the silica cartridge proved to be less critical than with ethyl acetate, this solvent was finally selected. The entire SPE–drying cartridge–GC set-up was combined with mass spectrometric (MS) detection for the determination of a mixture of micropollutants in real-life water samples. With 10-ml tap water samples spiked at the 0.5 μg/l level, for the majority of the test compounds the analyte recoveries generally were 60–106%, and (full-scan) detection limits typically were 0.01–0.03 μg/l. Some very polar analytes such as, e.g. dimethoate, were (partially) sorbed onto the silica packing of the drying cartridge.  相似文献   

10.
The Medical Commission of the International Olympic Committee forbids the use of anabolic androgenic steroids and beta2-agonists to improve athletic performance. In this work we have selected examples of anabolic androgenic compounds and their metabolites to evaluate the GC-MS analysis of some trimethylsilyl derivatives. The aim is to set the best GC conditions to improve the detection within the whole range of analyte elution temperatures. The initial column temperature was changed to 105 or 140 degrees C followed by 40 degrees C min(-1) to 200 degrees C and then 15 degrees C min(-1) to 300 degrees C. Using 140 degrees C as the initial oven temperature it was possible to obtain narrower initial analyte distributions for the compounds that elutes at the beginning of the chromatogram as clenbuterol, mabuterol, epimethylenediol and norandrosterone, without loss of derivatized metabolites signal. Later. eluting analytes, such as the stanozolol metabolites, furazabol and oxandrolone were not affected. Temperatures below 140 degrees C. resulted in partial derivatization for some analytes mainly stanozolol related structures. Therefore evaluation of derivatization conditions as occurring in three steps, the vial, vaporization chamber and capillary column, was thoroughly assessed. The new program temperature improves the signal-to-noise ratio for some compounds and shows adequate resolution for endogenous compounds. Some of the difficult key separations necessary for doping control enforcement were also obtained with the proposed method.  相似文献   

11.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

12.
Development and refinement of sample preparation protocols for retrospective detection and identification of chemical warfare agents (CWAs) and their markers is of paramount importance from verification point of view of chemical weapons convention (CWC). Precursors of nitrogen- and sulfur-mustards (NMPs and SMPs) are polar adsorptive markers of vesicant class of CWAs. Their detection in a given environmental sample may imply past contamination with mustards. For the efficient extraction of NMPs and SMPs from soil, on-matrix derivatisation-extraction (OMDEX) method was developed and optimized. The method involved trifluoroacetylation of analytes on soil itself, followed by extraction with suitable solvent. The extracted samples were analyzed by gas chromatography-mass spectrometry (GC-MS). This virtually single-step sample preparation offered better recoveries of NMPs and SMPs in comparison to conventionally used extraction, evaporation and derivatisation. The best recoveries of analytes were obtained with acetonitrile by OMDEX method. Dynamic linearity range of trifluoroacetylated (TFA) derivatives of NMPs and SMPs was 1-12 microg/L in GC-MS analysis in SIM mode. Repeatability and reproducibility of this technique containing 5 and 10 microg analytes/gm soil was <3.3% and <4.6%, respectively. OMDEX technique was finally applied for the detection of TFA derivatives of NMPs in the soil sample supplied in 16th official proficiency test conducted by OPCW in October 2004.  相似文献   

13.
Detection and identification of environmental signatures of chemical warfare agents is an important aspect of verification program of Chemical Weapons Convention (CWC). Alkylphosphonic acids (APAs) are ultimate and persistent degradation products of nerve agents. Their identification in a sample submitted for off-site analysis infers possible indication of contamination with nerve agents. This paper describes the development of a new sample preparation method which involves 'in situ derivatization and extraction' (INDEX) of acids from water. Derivatization is performed by alkylation of APAs with alkylbromides in surfactant less microemulsion (SLME). The derivatized analytes were analyzed by gas chromatography coupled with mass spectrometry. The developed method involves simultaneous derivatization (alkylation) and extraction of acidic analytes mediated by surfactant less microemulsion. Various derivatization-extraction parameters such as solvent, reaction time and temperature, base and alkyl bromides were optimized. Pentyl bromide in the presence of potassium carbonate and diisopropylamine at 100 degrees C derivatized the selected acids efficiently. Kinetic data for alkylation of methylphosphonic acids and some carboxylic acids were obtained to assess their relative susceptibility for alkylation in microemulsion. Methylphosphonic acid and isopropyl methylphosphonic acid took 140-150 min to reach completion while carboxylic acids took 100 min to complete the reaction. INDEX could be successfully performed even in the presence of interfering Ca(2+) and Mg(2+) ions.  相似文献   

14.
A comprehensive two-dimensional liquid chromatographic system incorporating a vacuum-evaporation interface was developed. Normal-phase liquid chromatography with a CN microcolumn was used as the first dimension (1(st)-D), and reversed-phase liquid chromatography with a C(18) monolithic column was used as the second dimension (2(nd)-D). An electronically controlled dual-position, ten-port valve with two identical storage loops served as the interface and the analysis time in the 2(nd)-D was 1.5 min. The solvent in the loops of the interface was evaporated at 25 degrees C under vacuum conditions, leaving the analytes on the inner wall of the loops. The mobile phase of the 2(nd)-D dissolved the analytes in the loop and injected them onto the second column, allowing an on-line solvent exchange of the fractions from the 1(st)-D to the 2(nd)-D. The chromatographic resolution of analytes on the two dimensions was evaluated. Sample loss due to evaporation in the interface was investigated with standard samples having different boiling points. The usefulness of the comprehensive 2-DLC system was demonstrated in the analysis of a traditional Chinese medicine Radix salviae miltiorrhiza bage extract.  相似文献   

15.
An interlaboratory trial was conducted for the validation of an enzyme-linked immunosorbent assay (ELISA) method for determination of appropriate heat treatment of animal meal. A commercially available ELISA test kit developed for the identification of beef in cooked food was used in the study. Twelve laboratories from 7 European countries examined 2 different analytical protocols to establish the most appropriate analytical method. Three different samples were used, 2 animal waste materials sterilized at 129 and 134 degrees C (wet conditions), respectively, and a meat and bone meal material processed at dry conditions (maximum temperature, 140 degrees C). Statistical evaluation applying t-statistics showed that the animal meal treated according to European legislation (>133 degrees C) was clearly distinguishable from the 2 other test materials at a 99% confidence level using both analytical protocols. This method can be considered as a complementary test to the immunoassay developed for the detection of pork in cooked food that is already applied in routine analysis for the surveillance of rendering plants.  相似文献   

16.
A sensitive and selective method has been developed for the simultaneous detection in blood of eleven trichothecenes of widely varying polarity. The procedure involved precipitation of blood proteins with acetone followed by a clean-up using reversed-phase Sep-Pak C18 cartridges. The extracted trichothecenes were derivatised as their pentafluoropropionyl esters, separated using capillary gas chromatography and detected using electron-capture negative ion chemical ionisation with methane reagent gas and selected-ion monitoring. Optimum sensitivity and selectivity were obtained using low source temperatures (60 degrees C indicated) and high source pressures (1 Torr indicated). Detection limits on 1-ml blood samples were in the range 0.1-5 ppb. The method was readily adaptable to the detection of other trichothecenes. A protocol was used which minimised the risk of cross-contamination. The method was validated in collaborative studies by the successful analysis of 42 blood samples spiked and submitted blind by two independent laboratories for analysis.  相似文献   

17.
Hatsis P  Lucy CA 《The Analyst》2001,126(12):2113-2118
The merits of varying column temperature in a cation exchange separation of alkali metals, alkaline earth metals and amines are considered. Increasing the column temperature (up to 60 degrees C) reduced the retention of all cations, but by varying extents. Consequently, selectivity changes were seen, with reversals in elution order in some cases. To ascertain when temperature is most useful as a separation aid, analytes were classed into three groups according to their temperature behaviour: alkali metals; alkaline earth metals; and amines. Adjusting the column temperature caused selectivity changes between analytes in different groups, but no selectivity changes occurred between analytes in the same group. Further, temperature was compared to the addition of modest amounts of acetonitrile as another means to alter selectivity. The benefits of elevated temperature were not just limited to selectivity changes. Improvements in the efficiencies of all analytes were noted at 60 degrees C. This was especially true for the amines which are severely tailed at ambient temperatures.  相似文献   

18.
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.  相似文献   

19.
A method was developed to analyze methyl tert.-butyl ether (MTBE) and its degradation products by gas chromatography with mass spectrometry (GC-MS) or flame ionization detection (FID) with direct aqueous injection. The column had dimensions of 30 m x 0.25 mm with film thickness 0.25 microm and a stationary phase of FFAP (nitroterephthalic acid-modified polyethylene glycol). The optimized GC conditions for non-acid components were as follows: carrier gas flow-rate,l mL/min; oven temperature, 35 degrees C for 5.5 min, ramped to 90 degrees C at 25 degrees C/min, then ramped to 200 degrees C at 40 degrees C/min and held at 200 degrees C for 8 min. The conditions for the acid components were: carrier gas flow-rate, 1 mL/min; oven temperature, 110 degrees C for 2 min, ramped to 150 degrees C at 10 degrees C/min, then ramped to 200 degrees C at 40 degrees C/min. The injection port contained a silanized-glass reverse-cup liner filled with Carbofrit. The minimum concentrations for the linear range for the selective ion monitoring mode were 30 to 100 microg/L, depending on the analytes. The minimum detection limit was 1 mg/L for MTBE and tert.-butanol when using FID. More components could be analyzed with the FFAP-type column than with the cyanopropylphenyl-dimethyl polysiloxane-type column.  相似文献   

20.
In this study Ru, deposited thermally on an integrated platform pyrolytic graphite tube, is proposed as a permanent modifier for the determination of Cu and Cr in urine samples by electrothermal atomic absorption spectrometry. The samples were diluted 1:1 with nitric acid (1% v/v). Pyrolysis and atomization temperatures for spiked urine samples were 1,100 degrees C and 1,900 degrees C respectively for Cu, and 1,400 degrees C and 2,500 degrees C respectively for Cr. For comparison purposes, the conventional modification with Pd+Mg was also studied. The sensitivity for Ru as permanent modifier was higher for the two analytes. The characteristic masses were 7.3 and 17.7 for Cr and Cu. The detection limits (3sigma) were 0.22 and 0.32 microg/L, for Cr and Cu, respectively. Good agreement was obtained with certified urine samples for the two elements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号