首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A radioimmunoassay is described that measures budesonide in plasma after solid-phase extraction (SPE/RIA) of the analyte. The performance of the assay was compared with that of a selective LC/MS method. The limit of quantitation of budesonide determined for the LC/MS and SPE/RIA assay was 50 pg/mL and 120 pg/mL, respectively. Based on quality control samples, a higher variability was observed for the SPE/RIA (CV between 4.5 and 23.0%) than for the LC/MS method (CV between 7.5 and 12.5%). Plasma samples obtained from healthy volunteers after administration of budesonide rectal foam were assayed by both methods. In a subset of samples, these results were compared with those measured by direct RIA to evaluate the selectivity of two assays. About two times higher budesonide levels were measured with the direct RIA (lacking the extraction step), presumably because of cross-reactivity with budesonide metabolites, indicating that the extraction step in SPE/RIA is necessary for selectivity. Both SPE/RIA and LC/MS methods were found to be selective, sensitive and suitable for pharmacokinetic studies. Results obtained from the two methods were compared with a number of statistical methods. Ratios of results obtained for the clinical samples were close to 1 (ratio LC-MS/ SPE/RIA = 0.98 +/- 0.27). Linear regression indicated a slope of 1.17 +/- 0.0378. The concordance correlation (r = 0.91) indicated that the agreement between both methods was fair while the Bland-Altman plot indicated that the agreement was less pronounced at higher concentrations (1-3 ng/mL). In summary, the results confirm that the SPE/RIA is an alternative to HPLC/MS and that among the statistical methods tested the concordance correlation analysis was judged to be the most informative test to assess the comparability of two methods.  相似文献   

2.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

3.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine gliclazide and metformin in human plasma using huperzine A as the internal standard (IS). After acetonitrile-induced protein precipitation of the plasma samples, gliclazide, metformin and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 10-10,000 ng ml(-1) for gliclazide and 7.8-4678.9 ng ml(-1) for metformin. The recoveries of the method were found to be 71-104%. The lower limits of quantification (LOQ) of the method were 10.0 and 7.8 ng ml(-1) for gliclazide and metformin, respectively. The intra- and interday precision was less than 15% for all quality control samples at concentrations of 100, 500, and 2000 ng ml(-1). The validated LC/MS/MS method has been used to study bioequivalence in healthy volunteers. These results indicate that the method was efficient with a very short running time (2.0 min) for metformin and gliclazide compared to the methods reported in the literature. The presented method had acceptable accuracy, precision and sensitivity and was used in clinical bioequivalence study.  相似文献   

5.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

6.
We report a GC/NICI-MS assay and a LC/ESI-MS/MS assay for the analysis of N-acetylcysteine (NAC) conjugates of (E)-2,4-diene VPA (NAC I and NAC II) identified in humans. The assay also includes the analysis of the NAC conjugate of 4,5-epoxy VPA (NAC III), an identified metabolite in rats treated with 4-ene VPA for its use in metabolic studies in animals. The highly sensitive GC/MS assay was designed to monitor selectively the diagnostic and most abundant [M - 181](-) fragment anion of the di-PFB derivatives of NAC I, NAC II, and NAC IV, the internal standard (IS) and the PFB derivative of NAC III. The higher selectivity of LC/MS/MS methodology was the basis for an assay which could identify and quantitate the underivatized conjugates simultaneously using MRM of the diagnostic ions m/z 130 and 123 arising from the CID of their protonated molecular ions [MH](+). The GC/MS assay employed liquid-liquid extraction whereas the LC/MS/MS assay used a solid-phase extraction procedure. Linearity ranges of the calibration curves were 0.10-5.0microg ml(-1) by GC/MS and 0.10-1.0microg ml(-1) by LC/MS/MS for NAC I, NAC II and NAC III (r(2) = 0.999 or better). Both assays were validated for NAC I and NAC II and provided good inter- and intra-assay precision and accuracy for NAC I and NAC II. The LOQ by LC/MS/MS was 0.1microg ml(-1), representing 1 ng of NAC I and NAC II. The same LOQ (0.1microg ml(-1)) was observed by GC/MS and was equivalent to 100 pg of each metabolite. NAC III was detected at concentrations as low as 0.01 microg ml(-1) by both methods. The total urinary excretion of the NAC conjugates in four patients on VPA therapy was determined to be 0.004-0.088% of a VPA dose by GC/MS and 0.004-0. 109% of a VPA dose by LC/MS/MS.  相似文献   

7.
A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1).  相似文献   

8.
A sensitive and selective method was developed for the determination of (R)-ketoprofen ((R)-kt) and (S)-ketoprofen ((S)-kt) in human plasma using chiral liquid chromatography/tandem mass spectrometry (LC/MS/MS). Plasma samples spiked with stable-isotope-labeled [(13)C(1), (2)H(3)]-(R and S)-ketoprofen, for use as the internal standards, were prepared for analysis using automated solid-phase extraction (SPE) in the 96-well microtiter format. The enantiomers were separated on an (R)-1-naphthylglycine and 3,5-dinitrobenzoic acid (Chirex 3005) 250x2.0 mm i.d. analytical column, equipped with a 30x2.0 mm i.d. guard column using isocratic mobile phase conditions. The (R)- and (S)-kt levels were quantifiable from 0.05 to 2500 ng ml(-1) by constructing two separate curves from calibration standards covering the same range. The first curve ranged from 0.05 to 100 and the second from 100 to 2500 ng ml(-1). A concentration of 0.05 ng ml(-1) of either enantiomer was easily detected using a 1 ml plasma sample volume. The average method accuracy, evaluated at four levels over an extended period, was better than +/-3% over the entire range. The precision for the same set of quality control samples ranged from 4.0 to 7.0 % RSD (n = 24). The method was applied to the evaluation of pharmacokinetic parameters in human plasma obtained from volunteers who received 25 mg of kt by peroral administration of Actron caplets or by topical administration of Oruvail gel.  相似文献   

9.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

10.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

11.
Kahalalide F (KF) is a novel cyclic depsipeptide anticancer drug, which has shown anticancer activity both in vitro and in vivo especially against human prostate cancer cell lines. To characterize the pharmacokinetics of KF during a phase I clinical trial in patients with androgen refractory prostate cancer, a method was developed and validated for the quantitative analysis of KF in human plasma using high-performance liquid chromatography (HPLC) coupled to positive electrospray ionization tandem mass spectrometry (ESI-MS/MS). Microbore reversed-phase liquid chromatography (LC) performed with mobile phases containing trifluoroacetic acid, an additive commonly used for separating peptides, resulted in substantial suppression of the signal for KF on ESI-MS/MS. An alternative approach employing a basic mobile phase provided an excellent response for KF when detected in the positive ion mode. Plasma samples were prepared for LC MS/MS by solid-phase extraction on C(18) cartridges. The LC separation was performed on a Zorbax Extend C(18) column (150 x 2.1 mm i.d., particle size 5 micro m) with acetonitrile -10 mM aqueous ammonia (85 : 15, v/v) as the mobile phase, at a flow-rate of 0.20 ml min(-1). A butyric acid analogue of KF was used as the internal standard. The lower limit of quantitation (LLQ) using a 500 micro l sample volume was 1 ng ml(-1) and the linear dynamic range extended to 1000 ng ml(-1). The inter-assay accuracy of the assay was -15.1% at the LLQ and between -2.68 and -9.05% for quality control solutions ranging in concentration from 2.24 to 715 ng ml(-1). The inter-assay precision was 9.91% or better at these concentrations. The analyte was stable in plasma under all relevant conditions evaluated and for a period of 16 h after reconstituting plasma extracts for LC analysis at ambient temperature.  相似文献   

12.
A simple and sensitive liquid chromatography (LC) method was developed for the simultaneous determination of eight quinolones in pig plasma samples. The following two methods of detection were used: ultraviolet (UV) and mass spectrometry with electrospray ionization (ESI/MS). Sample preparation consisted of solid-phase extraction (SPE) on Strata X cartridges prior to the analysis by LC/UV or LC/ESI/MS. The recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy of the method were evaluated using spiked pig plasma samples. The suitability of the method for pharmacokinetic studies was evaluated by determining the concentrations of enrofloxacin (ENR) and ciprofloxacin (CIP) also in pig plasma, after administration of 200mg of enrofloxacin per kilogram of fodder during 5 consecutive days.  相似文献   

13.
A rapid LC–MS/MS method has been developed and validated for the determination of losartan (LOS) and its metabolite losartan acid (LA) (EXP‐3174) in human plasma using multiplexing technique (two HPLC units connected to one MS/MS). LOS and LA were extracted from human plasma by SPE technique using Oasis HLB® cartridge without evaporation and reconstitution steps. Hydroflumethiazide (HFTZ) was used as an internal standard (IS). The analytes were separated on Zorbax SB C‐18 column. The mass transition [M–H] ions used for detection were m/z 421.0 → 127.0 for LOS, m/z 435.0 → 157.0 for LA, and m/z 330.0 → 239.0 for HFTZ. The proposed method was validated over the concentration range of 2.5–2000 ng/mL for LOS and 5.0–3000 ng/mL for LA with correlation coefficient ?0.9993. The overall recoveries for LOS, LA, and IS were 96.53, 99.86, and 94.16%, respectively. Total MS run time was 2.0 min/sample. The validated method has been successfully used to analyze human plasma samples for applications in 100 mg fasted and fed pharmacokinetic studies.  相似文献   

14.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

15.
A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.  相似文献   

16.
A method is described for the determination of melanotan-II (MT-II), a synthetic cyclic heptapeptide analog of alpha-melanocyte-stimulating hormone (alpha-MSH), in rat plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS). The analyte is recovered from plasma by solid-phase extraction (SPE) and subsequently analyzed by LC/MS/MS. A SPE procedure using OASIS 96-well plates is used for extraction of MT-II from rat plasma. Using the described approach a limit of quantitation of 5 ng/mL was achieved in rat plasma. This level of sensitivity allowed the determination of pharmacokinetic parameters, following intravenous administration of MT-II in rat.  相似文献   

17.
Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.  相似文献   

18.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

19.
Artemisinin is a widely used antimalarial drug. To evaluate the pharmacokinetics of artemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of artemisinin in rat plasma. For detection, a Sciex API 4000 LC/MS/MS instrument with an electrospray ionization (ESI) TurboIonSpray inlet in the positive ion multiple reaction monitoring (MRM) mode was used to monitor precursor ([M+NH4]+) --> product ions of m/z 300.4 --> 209.4 for artemisinin and m/z 316.4 --> 163.4 for artemether, the internal standard (IS). The plasma samples were pretreated by a simple liquid-liquid extraction with ether. The standard curve was linear (r > 0.99) over the artemisinin concentration range of 1.0-200.0 ng/mL in plasma. The method had a lower limit of quantification of 1.0 ng/mL for artemisinin in 100 microL of plasma, which offered a satisfactory sensitivity for the determination of artemisinin. The intra- and inter-day precisions were measured to be within +/-5.3% and accuracy between -2.6% and 1.2% for all quality control samples, lower limit of quantification and upper limit of quantification samples. The extraction recoveries of artemisinin and the IS were 95.4 +/- 4.5% and 92.8 +/- 3.9%, respectively. This present method was successfully applied to the characterization of the pharmacokinetic profile of artemisinin in rats after oral administration.  相似文献   

20.
Prostanoids are potent mediators of many physiological and pathophysiological processes. Of the many analytical methodologies used for their qualitative and quantitative analysis, electrospray tandem mass spectrometry coupled to liquid chromatography (LC/ESI-MS/MS) offers a rapid, sensitive and versatile system applicable to lipidomic analyses. We have developed an LC/ESI-MS/MS assay for twenty-seven mediators including prostaglandins, prostacyclines, thromboxanes, dihydroprostaglandins and isoprostanes. The assay was liner over the concentration range 1-100 pg/microL. The limits of detection and quantitation were 0.5-50 and 2-100 pg, respectively, whilst recoveries were from 83-116% depending on the metabolite. The assay can be applied to the profiling of prostanoids produced by a variety of biological fluids and extracts including brain, liver, plasma and urine, thus facilitating our understanding of the role of these lipid mediators in health and disease, as well as assisting in drug development.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号