首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 441 毫秒
1.
The present paper reports the optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry (GF AAS) employing a strategy based on the injection of the samples as detergent emulsions. The method was optimized in relation to the experimental conditions for the emulsion formation and taking into account that the three analytes (Cu, Fe and Pb) should be measured in the same emulsion. The optimization was performed in a multivariate way by employing a three-variable Doehlert design and a multiple response strategy. For this purpose, the individual responses of the three analytes were combined, yielding a global response that was employed as a dependent variable. The three factors related to the optimization process were: the concentration of HNO3, the concentration of the emulsifier agent (Triton X-100 or Triton X-114) in aqueous solution used to emulsify the sample and the volume of solution. At optimum conditions, it was possible to obtain satisfactory results with an emulsion formed by mixing 4 mL of the samples with 1 mL of a 4.7% w/v Triton X-100 solution prepared in 10% v/v HNO3 medium. The resulting emulsion was stable for 250 min, at least, and provided enough sensitivity to determine the three analytes in the five samples tested. A recovery test was performed to evaluate the accuracy of the optimized procedure and recovery rates, in the range of 88-105%; 94-118% and 95-120%, were verified for Cu, Fe and Pb, respectively.  相似文献   

2.
1-(3,4-Dimethoxyphenyl)-4-methyl-5-ethyl-7,8-dimethoxy-5H-2,3-benzodiazepine (tofisopam) contains one chiral center, so two enantiomeric forms exist. The ring system of tofisopam possesses two sterically stable boat structures, leading to two distinct conformers for each enantiomer. A method was developed for the separation of these enantiomers and conformers in the drug substances and drug products. Separation was achieved with a separation factor of at least 3.9 for any adjacent peaks. Validation of the method challenged linearity, limit of detection, limit of quantification, specificity, accuracy, repeatability, intermediate precision, robustness, and stability of standard and sample solutions, and all validation results met the acceptance criteria. A study of accuracy at 80%, 100%, and 120% levels gave recoveries of 100 +/- 1%. The RSD of six sample injections for repeatability was less than 0.5%. The detection limit of tofisopam enantiomer was as low as 0.12 microg/mL. The kinetics and thermodynamics of the interconversion of tofisopam conformers were also investigated, and the kinetic and equilibrium constants of the interconversion process were determined at 15 degrees C, 25 degrees C, and 35 degrees C.  相似文献   

3.
唐维英  黄泽玮  钱广生  魏宇涛  黄瑛  徐小平  余晓琴 《色谱》2018,36(12):1245-1260
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)同时测定茶叶、代用茶和饮料食品中63种非法添加化合物的分析方法。样品经甲醇超声提取后,采用Thermo Acclaim RSLC C18色谱柱(100 mm×2.1 mm,2.2 μm)分离,以5 mmol/L甲酸铵溶液(含体积分数为0.1%的甲酸)-0.1%(体积分数)甲酸乙腈为流动相进行梯度洗脱。在电喷雾离子源正离子模式下,采用动态多反应监测(dMRM)方式测定,外标法定量。63种待测化合物在相应的线性范围内呈良好的线性关系,相关系数(R2)均大于0.99;定量限为0.10~2.50mg/kg;在3个添加水平下,63种待测物的平均回收率为62.4%~129.4%,进样精密度和重复性的相对标准偏差为0.3%~9.6%(n=6)。该方法简便快捷、准确可靠,适用于茶叶、代用茶和饮料食品中非法添加具有解热镇痛效果的化合物检测。  相似文献   

4.
A liquid chromatography/mass spectrometry (LC/MS) method for amnesic shellfish poisoning toxins in shellfish was developed and validated. Tissue homogenate (4 g) was extracted with 16 mL methanol-water (1 + 1, v/v). Dilution into acetonitrile-water (1 + 9, v/v) was followed by C18 solid-phase extraction cleanup. Domoic acid (DA) and epi-domoic acid were determined by LC/MS/MS with electrospray ionization and multiple reaction monitoring. External calibration was performed with dilutions of a certified reference standard. Advantages of this method include speed, lower detection limits, and a very high degree of specificity. The LC/MS response was highly linear, and there were no significant interferences to the determination of DA. Formal method validation was performed on 4 shellfish species. Fortification studies gave recoveries (mean +/- SD; n = 24) of 93 +/- 14% at 1 mg/kg, and 93.3 +/- 7.6% at 20 mg/kg over all the species. Analysis of a mussel certified reference material showed the bias as < 5%. The limits of detection and quantitation were 0.15 and 0.5 mg/kg, respectively. Routine application of the method over 4 months gave a recovery for the QC sample (1 mg/kg fortified blank mussel homogenate) run with each batch of 88.9 +/- 5.5% (mean +/- SD; n = 37). The total uncertainty of measurement results were estimated as 0.12 (12%) at 0.25-5 mg/kg and 0.079 (7.9%) at 5-50 mg/kg. The major contribution to the uncertainty was the repeatability of the LC/MS determination, probably arising from subtle matrix effects.  相似文献   

5.
A simple, precise, and accurate isocratic RP-HPLC method was developed and validated for determination of eprosartan in bulk drug and tablets. Isocratic RP-HPLC separation was achieved on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using the mobile phase 0.5% formic acid-methanol-acetonitrile (80 + 25 + 20, v/v/v, pH 2.80) at a flow rate of 1.0 mL/min. The retention time of eprosartan was 7.64 +/- 0.05 min. The detection was performed at 232 nm. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was linear in the concentration range of 10-400 microg/mL with a correlation coefficient of 0.9999. The repeatability for six samples was 0.253% RSD; the intraday and interday precision were 0.21-0.57 and 0.33-0.71% RSD, respectively. The accuracy (recovery) was found to be in the range of 99.86-100.92%. The drug was subjected to the stress conditions hydrolysis, oxidation, photolysis, and heat. Degradation products produced as a result of the stress conditions did not interfere with detection of eprosartan; therefore, the proposed method can be considered stability-indicating.  相似文献   

6.
A new analytical method using QuEChERS procedure by gas chromatography with a nitrogen-phosphorus detector (GC-NPD) and ion trap mass spectrometry (GC-IT-MS) for the quantitative determination of tebuconazole, trifloxystrobin and its metabolite trifloxystrobin acid has been developed and validated. The analytes were extracted from five fruit and vegetable matrices using acetonitrile and subsequently cleaned up using primary secondary amine (PSA) or octadecylsilane (C18) as sorbent prior to GC analysis. The present methods provided sufficient sensitivity as reflected by the values of limit of detection (LOD) and limit of quantification (LOQ) of 0.4-7 and 1.2-20 μg/kg for GC-IT-MS/MS and GC-NPD. The recoveries were, on average, 68-117 and 68-121%, respectively, for three compounds by GC-NPD and GC-IT-MS/MS with intra-day precision achieved with an RSD of 2.7-19.1%. The inter-day precision was better than 15.1% as determined by GC-NPD. The QuEChERS procedure, by using two sorbents (PSA and C18) and the matrix-matched standards, gave satisfactory recoveries and RSD values in different matrices. IT-MS acquisition provided higher specificity and selectivity for pesticides and better limit of detection and quantification. However, the repeatability and precision of NPD method were better compared with IT-MS.  相似文献   

7.
A temperature-programmed packed capillary LC method with large-volume injection on-column focusing has been developed for screening and determination of 1-(2-methoxyphenyl)piperazine derivatives of airborne toluene-2,4-diisocyanate, toluene-2,6-diisocyanate, hexamethylenediisocyanate and methylenebisphenyl-4,4-diisocyanate, based on sampling methods described in MDHS 25/3. Injection volumes up to 100 microl were successfully loaded onto the 250x0.32 mm I.D. capillary column packed with 3 microm Hypersil ODS particles. The isocyanate derivatives were loaded at 10 degrees C and eluted by a three-step temperature program starting at 10 degrees C for 10 min, followed by a temperature ramp of 2.5 degrees C min(-1) to 45 degrees C and then 9.9 degrees C min(-1) to 90 degrees C. The mobile phase consisted of acetonitrile-acetate buffer (3% triethylamine, pH 4.5) (45:55, v/v). The isocyanate derivatives were dissolved in acetonitrile-acetate buffer (3% triethylamine, pH 4.5) (30:70, v/v) to achieve sufficient focusing. The concentration limit of detection of the individual derivatives utilizing an "U" shaped flow cell with a 8.0 mm light path and an injection volume of 100 microl was 44, 87, 43 and 210 pg ml(-1) for toluene-2,6-diisocyanate, hexamethylenediisocyanate, toluene-2,4-diisocyanate and methylenebisphenyl-4,4-diisocyanate, respectively. Within the investigated concentration range, 10-500 ng ml(-1), the linear calibration curves gave correlation coefficients ranging from 0.994 to 0.998. The repeatability of the method with regard to retention time and peak height ranged from 0.3 to 1.1% and 1.1 to 2.3% (n=9) relative standard deviation, respectively. The average recovery of the method, with regard to toluene-2,4-diisocyanate, was 97.7+/-1.6% (n=9).  相似文献   

8.
A microemulsion electrokinetic chromatographic method was used to separate fat-soluble vitamins. The separation of retinol, cholecalciferol, and delta- and alpha-tocopherol was performed using a microemulsion containing 0.75% (v/v) n-heptane, 30 mM bis(2-ethylhexyl)sodium sulfosuccinate (AOT), 5% (v/v) 1-butanol, 15% (v/v) 1-propanol and 15% (v/v) methanol in 20mM boric acid-sodium borate buffer. The effect of the different microemulsion constituents was studied, including the type and concentration of surfactant, buffer, oil and co-surfactants. The presence of methanol in the microemulsion was found to be necessary to achieve the separation of the tocopherols. Detection was carried out at 200, 265 and 325 nm for the tocopherols, cholecalciferol and retinol, respectively. Calibration curves and precision data were obtained for each analyte. Good linear relationships were found between the analytical signal and the analytes concentration in the 25-500 mg L(-1) for retinol and cholecalciferol, and 25-300 mg L(-1) for tocopherols ranges. The precision of the method afforded relative standard deviations in the 4.0-10% range.  相似文献   

9.
Three reliable, rapid and selective methods have been developed and validated for the determination of lamotrigine in the presence of its impurity, 2,3-dichlorobenzoic acid. The first method is spectrophotometric method using p-chloranilic acid forming a colored product with lambda(max) 519+/-2 nm. All variables affecting the reaction have been investigated and the conditions were optimized. Beer's law was obeyed over a concentration range of 10-200 microg ml(-1) with mean accuracy 100.13+/-0.44%. The molar ratio of the formed ion-association complex is found to be 1 : 1 as deduced by Job's method. The conditional stability constant (K(f)), standard free energy (DeltaG), molar absorptivity(epsilon), and sensitivity index were evaluated. The second method is based on TLC separation of the cited drug (Rf=0.75+/-0.01) from its impurity (Rf=0.23+/-0.01) followed by densitometric measurement of the intact drug spots at 275 nm. The separation was carried on silica gel plates using ethyl acetate : methanol : ammonia 35% (17 : 2 : 1 v/v/v) as a mobile phase. The linearity range was 0.5-10 microg/spot with mean accuracy 99.99+/-1.33%. The third method is accurate and sensitive stability-indicating HPLC method based on separation of lamotrigine from its impurity on a reversed phase C(18) column, using a mobile phase of acetonitrile : methanol : 0.01 M potassium orthophosphate (pH 6.7+/-0.1) (30 : 20 : 50 v/v/v) at ambient temperature 25+/-5 degrees C and UV detection at 275 nm in an overall analysis time of about 6 min., based on peak area. The injection repeatability, intraday and interday repeatability were calculated. The procedure provided a linear response over the concentration range 1-12 microg ml(-1) with mean accuracy of 99.50+/-1.30%. The proposed methods were successfully applied for the determination of lamotrigine in bulk powder, in dosage form and in presence of its impurity. The results obtained were analyzed by ANOVA to assess that no significant difference between each of the three methods and the reported one. The validation was performed according to USP guidelines.  相似文献   

10.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

11.
A narrow-bore HPLC-UV method was developed for the analysis of two of the more abundant naturally occurring phytosterols in vegetable oils: sitosterol and stigmasterol. The method enabled detection of the compounds at a concentration of 0.42 microg/ml and quantitation at concentrations of 0.52 and 0.54 microg/ml for sitosterol and stigmasterol, respectively. An excellent linearity was determined over two orders of concentration magnitude (r2 0.999-1.000) and verified by applying the Mandel fitting test (p>0.099) and the lack-of-fit test (p>0.057) performed at the 95% confidence level. A good intra-day precision ranging from 0.15 to 1.16% was calculated at two concentration levels (2 and 100 microg/ml). The inter-day reproducibility was verified on 3 different days by performing an homoscedasticity test and analysis of variance. A solid-phase extraction method was developed on silica cartridges for the isolation of phytosterols from soybean oil providing recovery values of 101+/-9 and 106+/-7% for sitosterol and stigmasterol, respectively. Good accuracy of the method was statistically demonstrated since no matrix effect was found for both the analytes. The developed method was applied to the quantitative assay of phytosterols in a soybean oil sample (61+/-5 mg/100 g of stigmasterol and 118+/-4 mg/100 g sitosterol). The HPLC-atmospheric pressure chemical ionization MS technique enabled the identification of stigmasterol, sitosterol and campesterol in the oil sample.  相似文献   

12.
Wang Q  Zhang Y  Ding H  Wu J  Wang L  Zhou L  Pu Q 《Journal of chromatography. A》2011,1218(52):9422-9427
An ethylene glycol solution was used as the electrophoretic running buffer in unmodified cyclic olefin copolymer (COC) microchips to minimize the interactions between the analytes and the hydrophobic walls of the plastic microchannels, enhance the resolution of the analytes and eliminate the uncontrollable dispersion caused by uneven liquid levels and non-uniform surfaces of the separation channels. Five amino acids that were labeled with fluorescein isothiocyanate (FITC) were used as model analytes to examine the separation efficiency. The effects of ethylene glycol concentration, pH and sodium tetraborate concentration were systematically investigated. The five FITC-labeled amino acids were effectively resolved using a COC microchip with an effective length of 2.5 cm under optimum conditions, which included using a running buffer of 20 mmol/L sodium tetraborate in ethylene glycol:water (80:20, v/v), pH 6.7. A theoretical plate number of 4.8 × 10(5)/m was obtained for aspartic acid. The system exhibited good repeatability, and the relative standard deviations (n=5) of the peak areas and migration times were no more than 3.4% and 0.7%, respectively. Furthermore, the system was successfully applied to elucidate these five amino acids in human saliva.  相似文献   

13.
A simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of six phenolic compounds, five anthraquinones (rhein, aloe-emodin, emodin, chrysophanol and physcion) and a flavonoid (kaempferol), in root extracts from Cassia alata L. Solid-phase extraction, using C(18) cartridges, was used to remove interfering substances from the root extracts. The extracts were analyzed on a C(18) column using an isocratic mobile phase which consisted of acetonitrile, methanol, and 10mM aqueous ammonium acetate (25:55:20, v/v). Identification of the analytes was performed by use of standards and on-line mass spectrometric detection using atmospheric pressure chemical ionization. The concentration of the phenolic compounds in the root extracts was determined using HPLC with ultraviolet detection at 260nm. The limits of detection obtained for the anlytes were in the range of 0.23-4.61ppm. The overall R.S.D. precision values (intra- and inter-day) for the retention times and peak-areas were lower than 0.16 and 2.10%, respectively. In addition, the recovery of the developed method for the analysis of these phenolic compounds was determined, and ranged from 81.2+/-4.3 to 106+/-2%.  相似文献   

14.
High-performance liquid chromatographic procedures with ultraviolet detection were developed for the quantitative determination of sulfadiazine (SDA) and trimethoprim (TMP) in swine tissues (kidney, liver, muscle, fat and fat + skin). In addition, high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometry was used for the confirmation of the identity of the analytes of interest. Chromatographic separation was achieved on a Spherisorb ODS-2 column (250 x 4.6 mm id, dp 5 microns). The mobile phase for SDA analysis consisted of 1% acetic acid in water-acetonitrile (85 + 15, v/v). For TMP analysis a 80 + 15 + 5 (v/v/v) mixture of 0.25% triethylammonium acetate in water, acetonitrile and methanol was used as the eluent. Sulfamerazine and ormethoprim were used as the internal standards for SDA and TMP analysis, respectively. For the isolation of the compounds of interest from biological samples, a liquid-liquid extraction with acetone and ethyl acetate, followed by a clean-up using a solid-phase extraction column (aminopropyl and benzenesulfonic acid for SDA, benzenesulfonic acid for TMP) was performed. Calibration graphs were prepared for all tissues and linearity was achieved over the concentration ranges tested (50-1000 ng g-1 for SDA, r > or = 0.9979; 25-500 ng g-1 for TMP, r > or = 0.9994). The method was validated at the maximum residue level (MRL, 100 ng g-1 for SDA and 50 ng g-1 for TMP), at half the MRL and at double the MRL for both SDA and TMP. The accuracy and precision (expressed as the within-day repeatability) were found to be within the required ranges for each specific concentration. The quantification limits were 50 ng g-1 for SDA and 25 ng g-1 for TMP. The limits of detection were below one half the MRLs. Both methods were selective for the determination of SDA and TMP. Biological samples (kidney, liver, muscle, fat and fat + skin) from pigs that received a commercial SDA-TMP preparation with the feed for five consecutive days (dose rate: 25 mg SDA and 5 mg TMP kg body weight-1 day-1) were analyzed using the described methods. The quantitative results were used to calculate a withdrawal time (12 days) to reach residue levels below the respective MRLs. This calculation was performed according to the recommendations of the European Agency for the Evaluation of Medicinal Products (EMEA/CVMP/036/95).  相似文献   

15.
高效液相色谱法测定土壤中香豆素类灭鼠药残留   总被引:1,自引:0,他引:1  
建立了测定土壤中杀鼠灵、杀鼠醚、溴敌隆、氟鼠灵、溴鼠隆5种香豆素类灭鼠药残留量的柱后衍生荧光检测高效液相色谱方法。样品在加入内标物氯杀鼠灵后用丙酮-氨水-甲醇(体积比为100:3:100)混合液提取,浓缩的提取液用5 mL正己烷-氯仿(体积比为3:1)混合液溶解,NH2固相萃取小柱净化,用15 mL 50 mmol/L四丁基磷酸二氢铵甲醇溶液洗脱分析物,移除溶剂,用甲醇-0.25%(体积分数)乙酸水溶液(体积比为3:2)混合液溶解,过滤后,经高效液相色谱分离,以甲醇-氨水-水(体积比为1:1:8)混合液为衍生试剂进行柱后衍生,采用荧光检测器检测。杀鼠灵、杀鼠醚、溴敌隆、氟鼠灵、溴鼠隆5种鼠药在0.02~10.00 mg/L范围内线性关系良好,相关系数均大于0.999,定量限(LOQ,S/N=10)为2.2~18.5 μg/L。在0.1~0.3 mg/kg添加水平内,5种灭鼠药的回收率为94.6%~118.0%,相对标准偏差(RSD)为0.8%~10.2% (n=3)。实验结果表明该方法灵敏、准确,重复性好。  相似文献   

16.
A rapid, accurate and sensitive method has been developed for the quantitative determination of four fluoroquinolone antimicrobial agents, enoxacin, norfloxacin, ofloxacin and ciprofloxacin, with high in-vitro activity against a wide range of Gram-negative and Gram-positive organisms.A Kromasil 100 C(8) 250 mm x 4 mm, 5 microm analytical column was used with an eluting system consisting of a mixture of CH(3)CN-CH(3)OH-citric acid 0.4 mol L(-1) (7:15:78 %, v/v). Detection was performed with a variable wavelength UV-visible detector at 275 nm resulting in limits of detection: 0.02 ng per 20 microL injection for enoxacin and 0.01 ng for ofloxacin, norfloxacin and ciprofloxacin. Hydrochlorothiazide (HCT) was used as internal standard at a concentration of 2 ng microL(-1). A rectilinear relationship was observed up to 2 ng microL(-1) for enoxacin, 12 ng microL(-1) for ofloxacin, 3 ng microL(-1) for norfloxacin, and 5 ng microL(-1) for ciprofloxacin. Separation was achieved within 10 min. The statistical evaluation of the method was examined by performing intra-day (n=8) and inter-day precision assays (n=8) and was found to be satisfactory with high accuracy and precision. The method was applied to the direct determination of the four fluoroquinolones in human blood serum. Sample pretreatment involved only protein precipitation with acetonitrile. Recovery of analytes in spiked samples was 97+/-6% over the range 0.1-0.5 ng microL(-1).  相似文献   

17.
An efficient method for the simultaneous determination of methyl tert.-butyl ether, tert.-butyl alcohol, benzene, toluene, ethylbenzene and xylene isomers in groundwater by purge-and-trap-gas chromatography-mass spectrometry was developed and validated. Experimental design was used to investigate the effects of temperature of extraction, time of extraction and percentage of salt added to the water samples. Regression models and desirability functions were applied to find the experimental conditions providing the highest global extraction yield. Validation was carried out in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LOD values ranging from 2.6 to 23 ng l(-1) were achieved, whereas linearity was statistically verified over two orders of magnitude for each compound. Precision was evaluated testing two concentration levels. Good results were obtained both in terms of intra-day repeatability and intermediate precision: RSD% lower than 4.5% at the highest concentration and lower than 13% at the lowest one were calculated for intra-day repeatability. A groundwater sample suspected of contamination by leaking underground petroleum storage tanks was analysed and some of the analytes were detected and quantitated.  相似文献   

18.
For the first time, a capillary electrophoretic (CE) method with sample stacking induced by a reverse migrating pseudostationary phase (SRMP) technique has been developed and validated for sensitive determination of phenobarbital (PB) and its p-hydroxyphenobarbital (PHPB) metabolite in rat urine samples. Separation and determination were optimized on a fused-silica capillary with a total length of 50 cm (effective length 40 cm) and 75 μm ID. The microemulsion background electrolyte consisted of 0.8% (v/v) ethyl acetate, 6.6% (v/v) butan-2-ol, 1.0% (v/v) acetonitrile, 2.0% (w/v) sodium n-dodecyl sulfate (SDS), and 89.6% (v/v) of 7.5 mM ammonium formate at pH 8. When this preconcentration technique was used, the sample stacking and the separation processes took place successively with changing the voltage with an intermediate polarity switching step. For practical application, a solid-phase extraction (SPE), C(18) sorbent with n-hexane/ethyl acetate (1?:?1%, v/v) as the elution solvent was used for sample purification and concentration. The SPE method gave good extraction yields for all the analytes, with absolute recovery values of 96.9% and 99.1% for PB and PHPB, respectively. The regression equations for PB and PHPB showed excellent linearity over a concentration range of 55-1386 ng mL(-1) for PB and PHPB (r = 0.998). The developed microemulsion electrokinetic capillary chromatography (MEEKC) method for separation of the studied compounds with SRMP as the electrophoretic preconcentration technique allowed detection limits in urine samples at 16.8 ng mL(-1) for PB and PHPB which are 15-fold lower than the reported CE method in the literature. The precision results, expressed by the intra-day and inter-day relative standard deviation (RSD) values range from 3.6 to 7.1% (repeatability) and from 3.2 to 7.2% (intermediate precision) for PB and PHPB, respectively, which were in line with Food and Drug Administration (FDA) criteria.  相似文献   

19.
Lärstad M  Loh C  Ljungkvist G  Olin AC  Torén K 《The Analyst》2002,127(11):1440-1445
A method for the determination of exhaled ethane, pentane and isoprene was developed and validated. The method was based on pre-concentration of the analytes on a multi-bed solid adsorbent tube containing Tenax TA, Carboxen 569 and Carboxen 1000, thermal desorption and gas chromatography (GC) with flame ionisation detection (FID). A pre-column in an end-cut GC system was used to avoid problems with water and strongly retained substances. The detection limits were 5, 2 and 6 pmol per sample for ethane, pentane and isoprene, respectively, using a sample volume of 500 ml. The linearity was good for all analytes with correlation coefficients exceeding 0.999. The repeatability for exhaled air samples was 7, 10 and 12% for ethane, pentane and isoprene, respectively. Analysis of a certified reference material of ethane and pentane did not differ significantly from the certified values. Ethane and pentane levels were stable up to six days of storage in sample tubes. Isoprene levels were not stable during storage in the sample tubes used here, but using Carbopack X instead of Carboxen 569, levels were stable up to two days. The levels of exhaled ethane, pentane and isoprene in healthy subjects (n = 4) were 8.1+/-5.8 pmol l(-1), 11+/-5.8 pmol l(-1) and 2.4+/-0.90 mnol l(-1), respectively. The method could, with minor modifications, be used to determine other low-molecular hydrocarbons in exhaled air as well.  相似文献   

20.
A simple high performance liquid chromatographic method for the determination of process-related impurities in bulk drug of the central anticholinergic compound pridinol mesylate, has been developed and validated. Spectroscopically characterized synthetic impurities were used as standards. The chromatographic separation was optimized employing an experimental design strategy, and was achieved on a C18 column with a mobile phase containing 50 mM potassium phosphate buffer (pH 6.4), MeOH and 2-propanol (20:69:11, v/v/v), delivered at a flow rate of 1.0 mL min−1. UV detection was performed at 245 nm. The optimized method was thoroughly validated, demonstrating to be selective, when the chromatogram was recorded with a diode-array detector and peak purities were evaluated (>0.9995). The method is robust and linear (r2 > 0.99) over the range 0.05-2.5% (5-250% with regards to the 1% specification limit for both process-related impurities); it is also precise, regarding repeatability (RSD ≤ 1.5% for all of the analytes) and intermediate precision aspects and LOQ values for the impurities are below 0.01%. Method accuracy, evidenced by low bias of the results and analyte recoveries in the range of 99.1-102.7%, was assessed at five analyte concentration levels. The usefulness of the determination was also demonstrated through the analysis of different lots of pridinol mesylate bulk substance. The results indicate that the method is suitable for the quality control of the bulk manufacturing of pridinol mesylate drug substance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号