1.
In this study, a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated to simultaneously determine the anticancer drugs etoposide and paclitaxel in mouse plasma and tissues including liver, kidney, lung, heart, spleen and brain. The analytes were extracted from the matrices of interest by liquid–liquid extraction using methyl tert‐butyl ether–dichloromethane (1:1, v/v). Chromatographic separation was achieved on an Ultimate XB‐C18 column (100 × 2.1 mm, 3 μm) at 40°C and the total run time was 4 min under a gradient elution. Ionization was conducted using electrospray ionization in the positive mode. Stable isotope etoposide‐d3 and docetaxel were used as the internal standards. The lower limit of quantitation (LLOQ) of etoposide was 1 ng/g tissue for all tissues and 0.5 ng/mL for plasma. The LLOQ of paclitaxel was 0.4 ng/g tissue and 0.2 ng/mL for all tissues and plasma, respectively. The coefficients of correlation for all of the analytes in the tissues and plasma were >0.99. Both intra‐ and inter‐day accuracy and precision were satisfactory. This method was successfully applied to measure plasma and tissue drug concentrations in mice treated with etoposide and paclitaxel‐loaded self‐microemulsifying drug‐delivery systems.  相似文献   

2.
A new solid‐phase extraction (SPE) pretreatment method using a home‐made polyvinylpolypyrrolidone‐florisil (PVPP‐F) column was developed for the analysis of patulin in apple and hawthorn products in China. Fifty samples (25 apple juices, 12 apple jams, and 13 hawthorn juices) were prepared using the new method and then analyzed by high performance liquid chromatography with diode array detection (HPLC‐DAD) on an Agela Venusil MP C18 reversed‐phase column (4.6 mm × 250 mm, 5 μm). The cleanup results for all samples using home‐made PVPP‐F column were compared with those obtained using a MycoSep®228 AflaPat column. The correlation coefficient R (0.9998) fulfilled the requirement of linearity for patulin in the concentration range of 2.5–250 μg/kg. The limits of detection (LODs) and quantification (LOQs) of patulin were 3.99 and 9.64 μg/kg for PVPP‐F column, and 3.56 and 8.07 μg/kg for MycoSep®228 AflaPat column, respectively. Samples were spiked with patulin at levels ranging from 25 to 250 μg/kg, and recoveries using PVPP‐F and MycoSep®228 AflaPat columns were in the range of 81.9–100.9% and 86.4–103.9%, respectively. Naturally occurring patulin was found in 2 of 25 apple juice samples (8.0%) and 1 of 13 hawthorn juice samples (7.7%) at concentrations ranging from 12.26 to 36.81 μg/kg. The positive results were further confirmed by liquid chromatography electrospray ionization mass spectrometry (LC‐ESI‐MS).  相似文献   

3.
A sensitive, selective and robust liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for the rapid determination of linarin in rat plasma. Separation of the analyte and warfarin as internal standard (IS) from 100 μL rat plasma was carried out by simple protein precipitation treatment. Chromatographic separation of the analyte was performed on a Diamonsil® C18 column (150 × 4.6 mm, 5 µm) using isocratic mobile phase consisting of methanol–0.5% formic acid (80:20, v/v). The flow rate was 0.6 mL/min and the total run time was not more than 4.0 min. The method was validated over a wide dynamic concentration range of 1.00–1000 ng/mL for linarin. The precision and accuracy values for linarin met the acceptance criteria according to US Food and Drug Administration guidelines. Linarin was stable in the stability studies including a long‐term test (?80°C for 43 days), a short‐term test (ambient for 2 h and autosampler for 8 h) and three freeze–thaw cycles (?80–25°C). The developed assay method was applied to the pharmacokinetic study in rats after a single intramuscular administration of 713 µg/kg linarin. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A novel and sensitive method was developed for the determination of tebuconazole enantioselectively using reversed‐phase LC‐MS/MS. The separation and determination were performed using on an amylose‐based chiral stationary phase, a Lux 3u Amylose‐2 column (150 mm×2.0 mm), under isocratic conditions at 0.3 mL/min flow rate. A series of chiral stationary phases were investigated and the effect of mobile phase composition on the enantioseparation was discussed. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the overall mean recoveries for two enantiomers from the soil, tomato, cucumber, pear and apple samples were 79.3–101.1% with 2.8–11.5% intra‐day relative standard deviations (RSDs) and 4.1–8.6% inter‐day RSDs at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 89.6–101.9% with 3.3–10.2% intra‐day RSDs and 5.1–7.7% inter‐day RSDs at 0.25, 0.5 and 2.5 μg/kg levels. The limits of detection (LODs) for all enantiomers in tomato, cucumber, pear, apple, soil and water were less than 0.6 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.0 μg/kg. The results indicate that this proposed method is convenient and reliable for the enantioselective determination of tebuconazole enantiomers in foods and environment samples.  相似文献   

5.
A simple and rapid method for determining six ergot alkaloids and four of their respective epimers was developed for rye and wheat. The analytes were extracted from the sample matrix with ACN/ammonium carbonate solution. The extract was purified with a commercial push‐through SPE column (Mycosep® 150 Ergot). After concentration and filtration steps, the final separation of the analytes was achieved with ultra‐performance LC‐MS/MS. The chromatographic separation of the ergot alkaloids was achieved in 4.5 min. The method performance proved satisfactory in the preliminary validation. The calculated LOQs were low ranging from 0.01 to 1.0 μg/kg for wheat and from 0.01 to 10.0 μg/kg for rye. At the concentration levels of 10, 50 and 200 μg/kg, the recoveries were between 80 and 120% in most cases and the within‐day repeatability (expressed as RSD) ranged between 1.3 and 13.9%. Despite the cleanup of the samples, some matrix effect was observed in the MS, highlighting the necessity of using matrix‐assisted standards. This is the first article to describe the application of the push‐through columns and ultra‐performance LC in the analysis of ergot alkaloids.  相似文献   

6.
A LC‐MS/MS method was developed and validated for the determination of cyclosporine A (CsA) and its three phase 1 metabolites AM1, AM9, and AM4N in whole blood and lymphocytes isolated on the Histopaque gradient. 200 μL of whole blood was precipitated with 10 mol/L zinc sulfate in acetonitrile/methanol (40:60, v/v) and lymphocytes isolated from 1.5 mL blood were extracted with acetonitrile/methanol (40:60, v/v). The analytes and internal standard cyclosporine D were separated on RP column BEH C18, 2.1×50 mm, 1.7 μm using gradient LC‐MS/MS analysis in positive electrospray mode. Time of analysis was 5 min. Linearity in blood was 5–2000 μg/L for CsA, AM1, and AM9; 2–500 μg/L for AM4N; and 2–500 μg/L for all substances in lymphocytes. Coefficient of variations was 1.8–9.8% and recovery was 92.0–110.0%. The method was used in early and chronic renal transplant patients for therapeutic drug monitoring of CsA to compare either its share in lymphocytes as target organ or binding to one lymphocyte. The same parameters were calculated for all metabolites tested.  相似文献   

7.
A highly sensitive, specific and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of rocilinostat in small volume mouse plasma (20 μL) using vorinostat as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation procedure with acetonitrile. Chromatography was achieved on Prodigy ODS‐2 column using a binary gradient using mobile phase A (0.2% formic acid in water) and B (acetonitrile) at a flow rate of 0.38 mL/min. The total chromatographic run time was 4.1 min and the elution of rocilinostat and IS occurred at ~3.2 and 2.9 min, respectively. A linear response function was established in the concentration range of 0.28–1193 ng/mL in mouse plasma. The intra‐ and inter‐day accuracy and precisions were in the ranges of 3.12–8.93 and 6.41–11.6%, respectively. This novel method has been applied to a pharmacokinetic study in mice. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid and sensitive LC–MS/MS method with good accuracy and precision was developed and validated for the pharmacokinetic study of quercetin‐3‐O‐β‐d ‐glucopyranosyl‐7‐O‐β‐d ‐gentiobioside (QGG) in Sprague–Dawley rats. Plasma samples were simply precipitated by methanol and then analyzed by LC–MS/MS. A Venusil® ASB C18 column (2.1 × 50 mm, i.d. 5 μm) was used for separation, with methanol–water (50:50, v/v) as the mobile phase at a flow rate of 300 μL/min. The optimized mass transition ion‐pairs (m/z) for quantitation were 787.3/301.3 for QGG, and 725.3/293.3 for internal standard. The linear range was 7.32–1830 ng/mL with an average correlation coefficient of 0.9992, and the limit of quantification was 7.32 ng/mL. The intra‐ and inter‐day precision and accuracy were less than ±15%. At low, medium and high quality control concentrations, the recovery and matrix effect of the analyte and IS were in the range of 89.06–92.43 and 88.58–97.62%, respectively. The method was applied for the pharmacokinetic study of QGG in Sprague–Dawley rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
An online SPE‐LC method that can determine both anthracyclines and taxanes simultaneously in human serum samples is reported. The entire method of extraction, separation and UV detection was achieved online by column switching between an SPE column (Biotrap 500 (20×4 mm)) and an analytical column (Zorbax XDB C18, 150×4.6 mm, 5 μm) with a 23 min total cycle time. The method is linear (r2>0.998) over the range of 0.5–25 μg/mL. The analytes of interest are retained on the SPE column with good recovery (84–117%), while proteins and other serum components elute to waste. This online clean‐up is much faster (150 s) and less manual than traditional off‐line extraction methods. Using 0.1 mL spiked serum samples, the LOQ was 0.5 μg/mL. Intra‐ and inter‐day precision were acceptable (≤15% RSD) at and above the LOQ. The method was applied to the analysis of serum samples from patients undergoing chemotherapy with these agents.  相似文献   

10.
A new method for glyphosate residue determination in apple has been developed. A SPE cartridge was used to clean up the samples before derivatization. Glyphosate was derivatized with 4‐chloro‐3,5‐dinitrobenzotrifluoride (CNBF) and quantified by reverse ion‐pair liquid chromatography using cetyltrimethylammonium bromide (CTAB) as ion‐pair reagent. In pH 9.5 H3BO3–Na2B4O7 medium, the reaction of glyphosate with CNBF was complete after 30 min at 60°C. The stability of the derivative on exposure to light at room temperature in methanol–water was demonstrated. The labeled glyphosate was separated on a Kromasil C18 column (250×4.6 mm, 5 μm) at room temperature and UV detection was applied at 360 nm. Separation was achieved within 15 min in gradient elution mode. The correlation coefficient for the method was 0.9998 at concentrations ranging from 0.1 to 50 μg/g. The calculated recoveries for glyphosate in apple were from 86.00 to 99.55%, and the relative standard deviations (n = 6) were from 1.43 to 6.32. The limit of detection was 0.01 μg/g for glyphosate in apple.  相似文献   

11.
Pogostone is an important constituent of Pogostemon cablin (Blanco) Benth., and possesses various known bioactivities. A rapid, simple and sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for the analysis of pogostone in rat plasma using chrysophanol as internal standard (IS). The analytes were extracted with methanol and separated using a reversed‐phase YMC‐UltraHT Pro C18 column. Elution was achieved with a mobile phase consisting of methanol–water (75:25, v/v) for 5 min at a flow rate of 400 μL/min. The precursor/product transitions (m/z) under MS/MS detection with negative electrospray ionization (ESI) were 223.0 → 139.0 and 253.1 → 224.9 for pogostone and IS, respectively. The calibration curve was linear over the concentration range 0.05–160 µg/mL (r = 0.9996). The intra‐ and inter‐day accuracy and precision were within ±10%. The validated method was successfully applied to the preclinical pharmacokinetic investigation of pogostone in rats after intravenous (5, 10 and 20 mg/kg) and oral administration (5, 10 and 20 mg/kg). Finally, the oral absolute bioavailability of pogostone in rats was calculated to be 70.39, 78.18 and 83.99% for 5, 10 and 20 mg/kg, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
There is interest in monitoring plasma concentrations of N‐desalkylquetiapine in relation to antidepressant effect. A simple LC‐MS/MS method for quetiapine and four metabolites in human plasma (50 μL) has been developed to measure concentrations of these compounds attained during therapy. Analytes and internal standard (quetiapine‐d8) were extracted into butyl acetate–butanol (10:1, v/v) and a portion of the extract analysed by LC‐MS/MS (100 × 2.1 mm i.d. Waters Spherisorb S5SCX; eluent: 50 mmol/L methanolic ammonium acetate, pH* 6.0; flow‐rate 0.5 mL/min; positive ion APCI‐SRM, two transitions per analyte). Assay calibration (human plasma calibrators) was linear across the ranges studied (quetiapine and N‐desalkylquetiapine 5–800, quetiapine sulfoxide 100–15,000, others 2–100 µg/L). Assay validation was as per FDA guidelines. Quetiapine sulfone was found to be unstable and to degrade to quetiapine sulfoxide. In 47 plasma samples from patients prescribed quetiapine (prescribed dose 200–950 mg/day), the (median, range) concentrations found (µg/L) were: quetiapine 83 (7–748), N‐desalkylquetiapine, 127 (7–329), O‐desalkylquetiapine 12 (2–37), 7‐hydroxyquetiapine 3 (<1–48), and quetiapine sulfoxide 3,379 (343–21,704). The analyte concentrations found were comparable to those reported by others except that the concentrations of the sulfoxide were markedly higher. The reason for this discrepancy in unclear. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Saflufenacil is a new protoporphyrinogen‐IX‐oxidase inhibitor herbicide. When used, it can enter the soil and has a high risk to reach and contaminate groundwater and aquatic systems. A rapid and sensitive method of ultra‐performance LC with MS/MS was developed for the simultaneous determination of saflufenacil and its two metabolites in soil samples. A modified quick, easy, cheap, effective, rugged, and safe method was applied as the pretreatment procedure. The method was validated by five types of soil samples collected from several regions of China, which all showed good linearity (R2 ≥ 0.9914) and precision (RSD ≤ 26.2%). The average recoveries of the three analytes ranged between 74.1 and 118.9% at spiking levels of 3–300 μg/kg. The method limits of detection (S/N 3:1) and method limits of quantification (S/N 10:1) achieved are in the ranges of 0.25–2.75 and 0.83–9.16 μg/kg, respectively. This indicated that the developed ultra‐performance LC with MS/MS method is a promising analytical tool for monitoring the environmental risks posed by saflufenacil.  相似文献   

14.
Cefuroxime lysine is a new second‐generation cephalosporins, which can penetrate the blood–brain barrier to cure the meningitis. In order to investigate its acute toxicokinetic study after intraperitoneal injection of 675 mg/kg cefuroxime lysine, a sensitive and clean ultra‐fast liquid chromatography–tandem mass spectrometry (UFLC‐MS/MS) method for the determination of cefuroxime lysine in microdialysate samples was developed and validated, which was compared with UFLC‐UV as a reference method. Chromatographic separation was performed on a Shim‐pack XR‐ODS C18 column (75 × 3.0 mm, 2.2 µm), with an isocratic elution of 0.1% formic acid in acetonitrile–0.1% formic acid in water (45:55, v/v) for LC‐MS and acetonitrile–20 mm potassium dihydrogen phosphate (pH 3.0,20:80, v/v) for LC‐UV. The lower limit of detection was 0.01 µg/mL for LC‐MS and 0.1 µg/mL for LC‐UV method, with the same corresponding linearity range of 0.1–50 µg/mL. The intra‐ and inter‐day precisions (relative standard deviation) for both methods were from 1.1 to 8.9%, while the accuracy was all within ±10.9%. The results of both methods were finally compared using paired t‐test; the results indicated that the concentrations measured by the two methods correlated significantly (p < 0.05), which suggested that the two methods based on LC‐MS and LC‐UV were suitable for the acute toxicokinetic study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
A simple, rapid and sensitive LC‐UV method was developed and validated for the determination of paclitaxel (PTX) in rabbit plasma and tissues. A 2 mL aliquot of acetonitrile and 10 μL ammonium acetate (pH 5.0, 6 m ) as extraction agents were used to markedly increase the extraction recoveries and greatly reduce the endogenous substances. The separation was achieved on a C18 column at 30 °C using an acetonitrile–ammonium acetate buffer (pH 5.0, 0.02 m ; 55:45, v/v) at a flow rate of 1.0 mL/min; UV detection was used at 227 nm. Good linearity was obtained between 0.025 and 10,000 µg/mL for plasma and between 0.025–200,000 µg/g for tissue samples (r > 0.999). The limit of detection was 6 ng/mL in plasma, 8 ng/g in heart and 12.5 ng/g in other tissues. The limit of quantitation was 25 ng/mL in plasma and heart, 125 ng/g in other tissues. The intra‐ and inter‐day assays of precision and accuracy for all bio‐samples ranged from 1.38 to 9.60% and from 83.6 to 114.5%, respectively. The extraction recoveries ranged from 70.1 to 109.5%. Samples were stable during three freeze–thaw cycles or stored in a freezer at ?20 °C for 30 days. The assay method was successfully applied to a study of the pharmacokinetics and tissue distribution of novel PTX lung targeting liposomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A fast and an efficient ultrasound‐assisted extraction technique using a lower density extraction solvent than water was developed for the trace‐level determination of tebuconazole in garlic, soil and water samples followed by capillary gas chromatography combined with nitrogen–phosphorous selective detector (GC–NPD). In this approach, ultrasound radiation was applied to accelerate the emulsification of the ethyl acetate in aqueous samples to enhance the extraction efficiency of tebuconazole without requiring extra partitioning or cleaning, and the use of capillary GC–NPD was a more sensitive detection technique for organonitrogen pesticides. The experimental results indicate an excellent linear relationship between peak area and concentration obtained in the range 1–50 μg/kg or μg/L. The limit of detection (S/N, 3 ± 0.5) and limit of quantification (S/N, 7.5 ± 2.5) were obtained in the range 0.2–3 and 1–10 μg/kg or μg/L. Good spiked recoveries were achieved from ranges 95.55–101.26%, 96.28–99.33% and 95.04–105.15% in garlic, Nanivaliyal soil and Par River water, respectively, at levels 5 and 20 μg/kg or μg/L, and the method precision (% RSD) was ≤5%. Our results demonstrate that the proposed technique is a viable alternative for the determination of tebuconazole in complex samples.  相似文献   

17.
Reversed‐phase and size‐exclusion liquid chromatography methods were validated for the assessment of streptokinase. The reversed‐phase method was carried out on a Jupiter C4 column (250 mm × 4.6 mm id) maintained at 25°C. The mobile phase consisted of 50 mM sodium sulfate solution pH 7.0 and methanol (90:10, v/v), run isocratically at a flow rate of 0.8 mL/min. The size‐exclusion method was carried out on a Protein KW 802.5 column (300 mm × 8.0 mm id), at 25°C. The mobile phase consisted of 40 mM sodium acetate solution pH 7.0, run isocratically at a flow rate of 1.0 mL/min. Retention times were 19.3 min, and 14.1 min, and calibration curves were linear over the concentration range of 0.25–250 μg/mL (25.75–25 750 IU/mL) (r 2 = 0.9997) and 5–80 μg/mL (515–8240 IU/mL) (r 2 = 0.9996), respectively, for reversed‐phase and size exclusion, with detection at 220 and 204 nm. Chromatographic methods were employed in conjunction with the in vitro bioassay for the content/potency assessment of Streptokinase, contributing to improve the quality control and ensure the efficacy of the biotherapeutic.  相似文献   

18.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

19.
We developed and validated an accurate and sensitive LC–MS/MS method for the simultaneous quantitation of ginsenoside Rg3 and Rh2 epimers (R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2) in rat plasma. Analytes were extracted from 0.1 mL aliquots of rat plasma by liquid–liquid extraction, using 2 mL of ethyl acetate. In this assay, dioscin (500 ng/mL) was used as an internal standard. Chromatographic separation was conducted using an Acclaim RSLC C18 column (150 × 2.1 mm, 2.2 μm) at 40°C, with a gradient mobile phase consisting of 0.1% formic acid in distilled water and in acetonitrile, a flow rate of 0.35 mL/min, and a total run time of 20 min. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with negative electrospray ionization at m/z 783.4 → 161.1 for R‐Rg3 and S‐Rg3, m/z 621.3 → 161.1 for R‐Rh2 and S‐Rh2, and m/z 867.2 → 761.5 for the internal standard. For R‐Rg3 and S‐Rg3, the lower limit of quantification was 5 ng/mL, with a linear range up to 500 ng/mL; for R‐Rh2 and S‐Rh2, the lower limit of quantification was 150 ng/mL, with a linear range up to 6000 ng/mL. The coefficient of variation for assay precision was less than 10.5%, with an accuracy of 86.4–112%. No relevant cross‐talk or matrix effect was observed. The method was successfully applied to a pharmacokinetic study after oral administration of 400 mg/kg and 2000 mg/kg of BST204, a fermented ginseng extract, to rats. We found that the S epimers exhibited significantly higher plasma concentrations and area under curve values for both Rg3 and Rh2. This is the first report on the separation and simultaneous quantification of R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2 in rat plasma by LC‐MS/MS. The method should be useful in the clinical use of ginseng or its derivatives.  相似文献   

20.
A very accurate and selective LC‐MS/MS method was developed and validated for the quantification of 2′‐C‐modified nucleoside triphosphate in liver tissue samples. An efficient pretreatment procedure of liver tissue samples was developed, using a fully automated SPE procedure with 96‐well SPE plate (weak anion exchange sorbent, 30 mg). Nucleotide hydrophilic interaction chromatography has been performed on an aminopropyl column (100 mm×2.0 mm, 3 μm) using a gradient mixture of ACN and ACN/water (5:95 v/v) with 20 mM ammonium acetate at pH 9.45 as mobile phase at 300 μL/min flow rate. The 2′‐C‐modified nucleoside triphosphate was detected in the negative ESI mode in multiple reaction monitoring (MRM) mode. Calibration curve was linear over the 0.05–50 μM concentration range. Satisfying results, confirming the high reliability of the established LC‐MS/MS method, were obtained for intraday precision (CV = 2.5–9.1%) and accuracy (92.6–94.8%) and interday precision (CV = 9.6–11.5%) and accuracy (94.4–102.4%) as well as for recovery (82.0–112.6%) and selectivity. The method has been successfully applied for pharmacokinetic studies of 2′‐C‐methyl‐cytidine‐triphosphate in liver tissue samples.  相似文献   