首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Stir bar sorptive extraction (SBSE) combined with dispersive liquid–liquid microextraction (DLLME) has been developed as a new approach for the extraction of six triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, triticonazole and difenconazole) in aqueous samples prior to GC‐flame ionization detection (GC‐FID). A series of parameters that affect the performance of both steps were thoroughly investigated. Under optimized conditions, aqueous sample was stirred using a stir bar coated with octadecylsilane (ODS) and then target compounds on the sorbent (stir bar) were desorbed with methanol. The extract was mixed with 25 μL of 1,1,2,2‐tetrachloroethane and the mixture was rapidly injected into sodium chloride solution 30% w/v. After centrifugation, an aliquot of the settled organic phase was analyzed by GC‐FID. The methodology showed broad linear ranges for the six triazole pesticides studied, with correlation coefficients higher than 0.993, lower LODs and LOQs between 0.53–24.0 and 1.08–80.0 ng/mL, respectively, and suitable precision (RSD < 5.2%). Moreover, the developed methodology was applied for the determination of target analytes in several samples, including tap, river and well waters, wastewater (before and after purification), and grape and apple juices. Also, the presented SBSE‐DLLME procedure followed by GC‐MS determination was performed on purified wastewater. Penconazole, hexaconazole and diniconazole were detected in the purified wastewater that confirmed the obtained results by GC‐FID determination. In short, by coupling SBSE with DLLME, advantages of two methods are combined to enhance the selectivity and sensitivity of the method. This method showed higher enrichment factors (282–1792) when compared with conventional methods of sample preparation to screen pesticides in aqueous samples.  相似文献   

2.
Bianjing Si  Jie Zhou 《中国化学》2011,29(11):2487-2494
Based on a molecularly imprinted organic‐silica hybrid‐based stir bar, a pre‐treatment methodology was developed for enrichment of nicosulfuron in aqueous samples. The molecularly imprinted organic‐silica hybrid‐based coating on the outer surface of a glass stir bar was prepared by in‐situ polymerization using nicosulfuron as a template molecule, α‐methacrylic acid as a functional monomer, methacryloxypropytrimethoxysilane as a cross‐linker in the mixture of acetonitrile and trichloromethane (V/V, 7.5:1). To achieve the selective extraction of the target analyte from aqueous samples, several main parameters, including extraction time, pH value and contents of inorganic salt in the sample matrix were investigated. Evidence was also presented by the scanning electronic microscopic images of the imprinted and non‐imprinted stir bars. Then, the extraction efficiency of the stir bar was tested with separate experiments and competitive sorption experiments. These results showed that using six sulfonylureas as substrates the molecularly imprinted organic‐silica hybrid‐based stir bar gave high selectivity for the template, nicosulfuron compared to the non‐imprinted organic‐silica hybrid‐based stir bar. This sorption extraction was coupled to liquid chromatography ultraviolet detection allowing the determination of nicosulfuron from tap water. The method showed good recoveries and precision, 96.0% (RSD 2.7%, n=3) for tap water spiked with 0.125 nmol (25.00 mL sample), suggesting that the stir bar can be successfully applied to the pre‐concentration of nicosulfuron in real aqueous samples.  相似文献   

3.
《Analytical letters》2012,45(13):2231-2245
Abstract

A rapid and reliable analytical method, at trace level concentration was developed and validated for monitoring polychlorinated biphenyls (PCBs) in Jordanian surface water. The method combines the advantage of liquid extraction together with gas chromatography‐mass spectrometry (GC/MS) and gas chromatography‐electron capture detector (GC/ECD). The performance of the method was evaluated by analyzing certified reference material (CRM) of the analytes and applied on real water samples collected from different sites in Jordan. A mixture of 60∶40 dichloromethan‐petroleum ether was chosen as a convenient binary solvent for liquid–liquid extraction. The GC conditions for GC/MS were optimized using He as a carrier gas, temperature programming, and chlorpropham as an internal standard (IS).

The conditions for GC/ECD were performed using N2 gas and a temperature program from 160 to 280°C with different increasing rates. The method of GC/MS in the selective ion mode (SIM) gave linear relationships for all PCBs tested between 0.60–6.0 µg/l with R 2=0.9934 (n=7×18). Recoveries from spiked water samples ranged between 87.6 and 91.4%. The mean accuracy and precision obtained were 4.9% and 2.16%, respectively. The mean of detection limit was 0.14±0.04 µg/l. In GC/ECD, linear relationships for all PCBs examined over the range of 0.3–2.4 µg/l was verified as characterized by a linear regression equation and correlation coefficient, R 2=0.9915 (n=12). The average precision and accuracy were 4.86% and 5.21%, respectively. Analyses results clarified that none of the examined Jordanian water samples contained any of the searched for PCBs within the detection limit achieved.  相似文献   

4.
A simple and reliable method was developed to detect two basic synthetic dyes, rhodamine B (RB) and rhodamine 6G (R6G), in wastewater and surface water samples by high performance liquid chromatography with fluorescence detection (HPLC‐FLD). These dyes have been reported to be both mutagenic and carcinogenic in various organisms. The contents of these two dyes in water samples were extracted by Oasis HLB solid‐phase extraction (HLB‐SPE), and were then determined by an isocratic HPLC using an Atlantis® T3‐C18 column. Water samples at various pH conditions and the compositions of eluents for SPE were evaluated. The results indicate that the proposed method is precise and sensitive in analyzing these two basic synthetic dyes, and the limits of quantitation were 1.5 ng/L for RB and 0.3 ng/L for R6G in 100 mL of water samples. The recovery of analytes in spiked surface water and municipal wastewater treatment plant (WWTP) effluent samples ranged from 61 to 90% with the precision (RSD) ranging from 2 to 12%. The concentrations of analytes were detected in various water samples ranging from 0.7 to 81 ng/L.  相似文献   

5.
A fast and an efficient ultrasound‐assisted extraction technique using a lower density extraction solvent than water was developed for the trace‐level determination of tebuconazole in garlic, soil and water samples followed by capillary gas chromatography combined with nitrogen–phosphorous selective detector (GC–NPD). In this approach, ultrasound radiation was applied to accelerate the emulsification of the ethyl acetate in aqueous samples to enhance the extraction efficiency of tebuconazole without requiring extra partitioning or cleaning, and the use of capillary GC–NPD was a more sensitive detection technique for organonitrogen pesticides. The experimental results indicate an excellent linear relationship between peak area and concentration obtained in the range 1–50 μg/kg or μg/L. The limit of detection (S/N, 3 ± 0.5) and limit of quantification (S/N, 7.5 ± 2.5) were obtained in the range 0.2–3 and 1–10 μg/kg or μg/L. Good spiked recoveries were achieved from ranges 95.55–101.26%, 96.28–99.33% and 95.04–105.15% in garlic, Nanivaliyal soil and Par River water, respectively, at levels 5 and 20 μg/kg or μg/L, and the method precision (% RSD) was ≤5%. Our results demonstrate that the proposed technique is a viable alternative for the determination of tebuconazole in complex samples.  相似文献   

6.
Besides microbiological methods, fecal pollution of surface waters is estimated by gas chromatographic (GC) determination of sterols present in human and animal sewage effluents. The most frequently used biomarkers for the evaluation of contamination levels include coprostanol, cholesterol, dihydrocholesterol, stigmasterol, beta-sitosterol, and stigmastanol. Although several GC techniques are used to measure these compounds in aquatic systems, the analytical performance of GC-mass spectrometric (MS) determination of these sterols has not been systematically characterized. Therefore, the aim of this work is to validate a simple and rapid GC-MS method for the simultaneous analysis of six sterols, considering all parameters and requirements defined by Good Laboratory Practice. Following liquid-liquid extraction of spiked surface water samples, the extracts are silylated and analyzed by GC-MS. The method is evaluated for linearity and limits of detection and quantitation, as well as for precision, extraction efficiency, and stability. The assay is linear up to 160 ng; the limits of detection and quantitation are 5-10 ng and 20 ng, respectively. The within- and between-day precision ranged from 1% to 9% and 1% to 16%, respectively. The extraction efficiency was 65-80%. The stability studies indicate that the sterols in surface water samples begin to degrade after 24 h of refrigerated storage. However, three freeze/thaw cycles could be performed without their decomposition. The method is applied to the analysis of surface water and wastewater samples. The technical advantages make this GC-MS analysis suitable for routine environmental monitoring of fecal pollution in aquatic systems.  相似文献   

7.
制备了以聚醚砜酮(PPESK)为萃取相的新型固态萃取搅拌棒, 建立了一种固态萃取搅拌棒/热解吸器直接热解吸/气相色谱联用分析水样品中痕量爆炸物的新方法. 将萃取搅拌棒放入水样品中完成萃取后, 再直接放入热解吸器中于250 ℃热解吸, 将萃取到搅拌棒上的分析物一次性全部导入气相色谱柱中. 对于硝基苯类爆炸物, PPESK固态萃取搅拌棒的萃取容量比萃取纤维针提高1个数量级以上; 其萃取效率比PDMS固态萃取搅拌棒高2个数量级. 对所测定的7种爆炸物的最低检出限为0.008~0.022 μg/L, 方法的重复性误差(RSD)为6.9%~16%, 在线性浓度范围0.06~10.0 μg/L(除TNT)内, 线性相关系数r为0.9962~0.9998. 在优化的条件下对硝基苯类炸药生产过程中产生的废水进行了分析, 结果表明, 方法的回收率分别为88%~100%(低浓度样品)和61%~88%(高浓度样品), 该方法的重复性误差(RSD)小于11%.  相似文献   

8.
搅拌棒吸附子萃取与GC-MS法测定水中20种有机氯农药   总被引:2,自引:0,他引:2  
建立了搅拌棒吸附子萃取/气相色谱-质谱法(SBSE/GC-MS)同时检测水中α-六六六、γ-六六六、β-六六六、七氯、δ-六六六、艾氏剂、环氧七氯、γ-氯丹、顺-氯丹、硫丹Ⅰ、p,p-滴滴伊、狄氏剂、异狄氏剂、p,p-滴滴滴、硫丹Ⅱ、p,p-滴滴涕、异狄氏剂醛、硫丹硫酸盐、甲氧滴滴涕、异狄氏剂酮20种有机氯农药含量的方法.样品在室温下经拌棒吸附子搅拌吸附,甲醇解吸附后,以J&W DB-35 MS(30 m×0.25 mm×0.25 μm)石英毛细管色谱柱为分析柱,气相色谱-质谱选择离子流模式检测.考察了萃取时间、氯化钠及甲醇加入量等对萃取的影响.实验结果表明:在2.5 ~20.0 μg/L 范围内,20种有机氯农药呈良好的线性关系,检出限(S/N=3)为0.008 ~0.118 μg/L,水样中分别添加2.5、20 μg/L的20种有机氯农药,回收率为 52% ~117%,相对标准偏差小于13%(n= 6).该方法操作简便、快速、灵敏度高,应用于实际样品检测,结果满意.  相似文献   

9.
This work presents a method to separate polar naphthalenesulfonate (NS) isomers by capillary zone electrophoresis (CZE) with ultraviolet detection in industrial effluents and river water samples. The method involves extraction of samples by a polystyrene‐divinylbenzene copolymer (PS‐DVB) solid‐phase extraction (SPE) cartridge. The most effective CZE separation conditions were obtained in 20 mM borate buffer with 30% acetonitrile at pH 9.0 and 30 °C. The method proposed herein provides a high precision and sensitivity for NS isomers, to quantitation at ≤ 1.0 μg/L in 200 mL of the water samples. Recovery of the NS isomers in spiked water samples ranged from 73% to 87% while RSD ranging from 5.6 to 9.7%. The analysis of industrial effluents and river water samples was performed and naphthalene‐2‐sulfonate was found as a major pollutant. The difficulties in quantitating and identifying analytes in complex environmental samples can be resolved by using an internal standard response factor to calculate concentrations and relative migration times for peak confirmation.  相似文献   

10.
Stir‐bar sorptive extraction and liquid desorption followed by large volume injection‐gas chromatography coupled to mass spectrometry under selected ion monitoring mode acquisition (SBSE‐LD/LVI‐GC‐MS(SIM)) was applied for the determination of six benzotriazole UV stabilizers (Tinuvin P, Allyl‐bzt, Tinuvin 320, Tinuvin 326, Tinuvin 327 and Tinuvin 328) in wastewater matrices. Parameters affecting the performance of extraction and desorption steps were thoroughly evaluated using uni‐ and multivariate optimization strategies, based on the use of experimental factorial designs. Assays performed with stir bars, coated with 24 μL of polydimethylsiloxane, on 25 mL of ultra‐pure water samples spiked at the 0.5 ng/mL level, yielded recoveries ranging from 47.9±1.4% (Tinuvin P) to 103.1±3.6% (Tinuvin 326), under optimized experimental conditions. When applied to complex matrices (e.g. wastewater), the methodology showed also excellent linear dynamic ranges (0.02–10.00 ng/mL) for the six benzotriazole UV stabilizers studied with correlation coefficients higher than 0.9970, limits of quantification in between 0.004 and 0.015 ng/mL, suitable repeatability (RSD<12.7%) and reproducibility (RSD<4.5%). The application of the proposed methodology to urban sewage waters from Spain and Portugal wastewater plants revealed the presence of low contents of some benzotriazole UV stabilizers.  相似文献   

11.
A fast method for the determination of eight organotin compounds (OTs), monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), tetrabutyltin (TeBT), monophenyltin (MPhT), diphenyltin (DPhT), triphenyltin (TPhT) and tetraphenyltin (TePhT), in water, sediments and mussels, was developed using low-pressure gas chromatography/tandem mass spectrometry (LPGC/MS/MS). The method is based on sodium diethyldithiocarbamate (DDTC) complexation of the ionic organotins, followed by extraction of the target matrices and derivatization by a Grignard reagent, as described in a previously published method for water samples. Solid-phase extraction was selected as extraction method from water samples after comparison with liquid-liquid extraction, but extraction of the OTs from sediment and mussel samples was performed using toluene. Matrix-matched calibration standards were used to minimize matrix effects. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, detection limit (LOD), quantitation limit (LOQ), precision, and recovery were determined. Recoveries of OTs in spiked matrices ranged from 86-108% in water and from 78-110% in sediments and mussels, with precision values lower than 18%. Detection limits ranged from 0.1-9.6 ng L(-1) in water, and 0.03-6.10 microg kg(-1) in the other matrices. The present implementation of LPGC rather than conventional capillary GC permitted use of large-volume injection and reduced analysis time by a factor of two. The proposed methodology was applied to the determination of OTs in real samples of water, marine sediments and mussels from the west coast of the Mediterranean Sea (Spain).  相似文献   

12.
In this study, a new stir cake sorptive extraction using a boron‐rich monolith as the adsorbent was prepared by the in situ copolymerization of vinylboronic anhydride pyridine complex and divinylbenzene. The effect of preparation parameters, including the ratio of vinylboronic anhydride pyridine complex and divinylbenzene, monomer mixture, and porogen solvent, on extraction performance was investigated thoroughly. The physicochemical properties of the adsorbent were characterized by infrared spectroscopy, scanning electron microscopy, and mercury intrusion porosimetry. Several conditions affecting the extraction efficiency were investigated in detail. Under the optimized conditions, a convenient and sensitive method for the determination of trace fluoroquinolones residues in water and milk samples was established by coupling stir cake sorptive extraction with high‐performance liquid chromatography and diode array detection. The limits of detection for the target compounds were 0.10–0.26 and 0.11–0.22 μg/L for water and milk samples, respectively. In addition, the developed method showed good linearity, repeatability, and precision. Finally, the proposed method was successfully applied for the detection of trace fluoroquinolones residues in environmental water and milk samples. Satisfactory recoveries were obtained for the determination of fluoroquinolones in spiking samples that ranged from 68.8 to 120%, with relative standard deviations below 10% in all cases.  相似文献   

13.
In this paper, a novel monolithic stir bar based on molecularly imprinted polymer (MIP) was firstly developed by filling modified neodymium magnet (Nd2Fe14B) powders into a glass tube (60 × 4 mm), followed by the imprinted grafting with bisphenol A (BPA) as the template molecule by thermal polymerization. It has been successfully used for the stir bar sorptive extraction (SBSE) and its extraction performance illustrated that the MIP‐encapsulated stir bar had stronger affinity to the template molecule, compared with the stir bar based on the non‐imprinted molecularly polymer (NIP). Under the optimal extraction conditions, a simple method based on the coupling of MIP‐SBSE with high performance liquid chromatography (HPLC) was used for the selective determination of the model mixtures of BPA, 4‐phenylphenol (PP) and phenol (P) in bottled water. The recoveries of BPA, PP and P were in the range of 88.5‐96.1%, 78.2‐89.7%, 81.3‐89.5% at three spiked levels, respectively, demonstrating that higher extraction and the specific absorption occurred between the template molecule and the prepared MIP stir bar.  相似文献   

14.
A method for the determination of trace amounts of off-flavor compounds including 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole in drinking water was developed using the stir bar sorptive extraction technique followed by thermal desorption-GC-MS analysis. The extraction conditions such as extraction mode, salt addition, extraction temperature, sample volume and extraction time were examined. Water samples (20, 40 and 60 ml) were extracted for 60-240 min at room temperature (25 degrees C) using stir bars with a length of 10 mm and coated with a 500 microm layer of polydimethylsiloxane. The extract was analyzed by thermal desorption-GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range from 0.1 or 0.2 or 0.5 to 100 ng l(-1) for all the target analytes, and the correlation coefficients were greater than 0.9987. The detection limits ranged from 0.022 to 0.16 ng l(-1). The recoveries (89-109%) and precision (RSD: 0.80-3.7%) of the method were examined by analyzing raw water and tap water samples fortified at the 1 ng l(-1) level. The method was successfully applied to low-level samples (raw water and tap water).  相似文献   

15.
Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra‐high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4–55.1 and 61.5–184 ng/L, respectively. Recoveries between 68.4–92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples.  相似文献   

16.
A simultaneous determination method using solid‐phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid‐phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1–74.3 and 0.5–236.6 ng/L, respectively. Accuracy and precision values were 71–120 and 1–17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water.  相似文献   

17.
A fast and sensitive analytical method based on stir bar sorptive extraction technology with gas chromatography and mass spectrometry was developed to simultaneously analyze 18 kinds of polychlorinated biphenyls and 20 kinds of organochlorine pesticides in aqueous samples. A long adsorption time and small sample volume, which are problems encountered in conventional methods of stir bar sorptive extraction, were effectively solved by simultaneously using multiple stir bars for enrichment with sequential cryofocusing and merged injection. Optimized results showed good linear coefficients in the range of 10–500 ng/L and the method detection limits of 0.12–2.07 ng/L for polychlorinated biphenyls and organochlorine pesticides. The recovery ratios of the spiked samples at different concentrations were between 64.7 and 111.0%, and their relative standard deviations ranged from 0.9 to 17.6%. Four types of the studied compounds were determined in Qiantang River water samples, and their contents were between 0.82 and 5.00 ng/L.  相似文献   

18.
This work describes an effective, low solvent consumption and affordable sample preparation approach for the determination of eight UV filters in surface and wastewater samples. It involves sorptive extraction of target analytes in a disposable, technical grade silicone disc (5 mm diameter × 0.6 mm thickness) followed by organic solvent desorption, large volume injection (LVI), and gas chromatography-mass spectrometry determination. Final working conditions involved overnight extraction of 100-mL samples, containing 10% of methanol, followed by analytes desorption with 0.2 mL of ethyl acetate. The method provides linear responses between the limits of quantification (from 0.003 to 0.040 ng mL−1) and 10 ng mL−1, an intra-day precision below 13%, and low matrix effects for surface, swimming pool, and treated sewage water samples. Moreover, the extraction yields provided by silicone discs were in excellent agreement with those achieved using polydimethylsiloxane-covered stir bars. Several UV filters were found in surface and sewage water samples, with the maximum concentrations corresponding to octocrylene.  相似文献   

19.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

20.
An effective and simple method for polar phenols in water matrix was developed by using stir bar sorptive extraction (SBSE) based on a hydrophilic poly(vinylpyrrolididone‐divinylbenzene) (VPDB) monolithic material and HPLC analysis. To achieve optimum extraction performance for phenols, several parameters, including extraction and desorption time, desorption solvent, pH value, and ionic strength of sample matrix, were investigated. Under the optimized experimental conditions, eight phenols were directly enriched from water samples and analyzed by HPLC‐DAD. The detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 0.72–1.37 and 2.40–4.27 ng/mL from spiked water, respectively. Recoveries of eight phenolic compounds were found in the range of 55.2–95.9%. The calibration curves showed the linearity ranging from 5 to 150 ng/mL with linear regression coefficient R2 values above 0.98. Method repeatability presented as intra‐ and interday precisions were also found with the RSDs less than 4.10 and 7.61%, respectively. The distribution coefficients between VPDB and water (KVPDB/W) for phenolic compounds were also calculated and compared with KO/W. Finally, the proposed method was successfully applied to the determination of the target compounds in tap water, sea water and wastewater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号