首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and sensitive gas chromatography with mass spectrometry method for the determination of venlafaxine in rat plasma has been developed and applied to a drug–drug interaction study of fluoxetine on pharmacokinetics of venlafaxine in rats. Rat plasma was spiked with 2% aqueous ammonia before subjected to preactivated C18 solid‐phase extraction columns and eluted with methanol. No endogenous interferences were observed under optimal condition. The calibration curve was linear (R 2 = 0.9994) in the range of 10–1000 ng/mL. The quantification limit of venlafaxine in rat plasma was 10 ng/mL. The accuracy was in the range of 85–110%, and the extraction recovery was no less than 50%. Both the intra‐ and interday precision were 5.0–10.7%. The concentration–time curve showed that plasma concentrations of the coadministration group (group B) were higher than that of single dose group (group A). Both values of C max (0.069 mg/L) and AUC0→∞ (0.291 mg h/L) in group B were statistically greater than that of C max (0.046 mg/L) and AUC0→∞ (0.181 mg·h/L) in group A (< 0.05). The results indicated that a significant effect of fluoxetine was shown on the pharmacokinetics of venlafaxine, suggesting that drug–drug interactions are of concern for the treatment of depression with the combined use of venlafaxine and fluoxetine.  相似文献   

2.
A sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determination of bakkenolide D (BD), which was further applied to assess the pharmacokinetics of BD. In the LC‐MS/MS method, the multiple reaction monitoring mode was used and columbianadin was chosen as internal standard. The method was validated over the range of 1–800 ng/mL with a determination coefficient >0.999. The lower limit of quantification was 1 ng/mL in plasma. The intra‐ and inter‐day accuracies for BD were 91–113 and 100–104%, respectively, and the inter‐day precision was <15%. After a single oral dose of 10 mg/kg of BD, the mean peak plasma concentration of BD was 10.1 ± 9.8 ng/mL at 2 h. The area under the plasma concentration–time curve (AUC0–24 h) was 72.1 ± 8.59 h ng/mL, and the elimination half‐life (T1/2) was 11.8 ± 1.9 h. In case of intravenous administration of BD at a dosage of 1 mg/kg, the AUC0–24 h was 281 ± 98.4 h?ng/mL, and the T1/2 was 8.79 ± 0.63 h. Based on these results, the oral bioavailability of BD in rats at 10 mg/kg is 2.57%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
In the present study a simple, fast, sensitive and robust method to quantify mirtazapine in human plasma using quetiapine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a simple protein precipitation with methanol and were analyzed by high‐performance liquid chromatography coupled to an electrospray tandem triple quadrupole mass spectrometer (HPLC‐ESI‐MS/MS). Chromatography was performed isocratically on a C18, 5 µm analytical column and the run time was 1.8 min. The lower limit of quantitation was 0.5 ng/mL and a linear calibration curve over the range 0.5–150 ng/mL was obtained, showing acceptable accuracy and precision. This analytical method was applied in a relative bioavailability study in order to compare a test mirtazapine 30 mg single‐dose formulation vs a reference formulation in 31 volunteers of both sexes. The study was conducted in an open randomized two‐period crossover design and with a 14 day washout period. Since the 90% confidence interval for Cmax, AUClast and AUC0–inf were within the 80–125% interval proposed by the Food and Drug Administration and ANVISA (Brazilian Health Surveillance Agency), it was concluded that mirtazapine 30 mg/dose is bioequivalent to the reference formulation, according to both the rate and extent of absorption. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
The herb couple has special clinical significance in reducing the toxicity and increasing the efficacy of drugs. The combination of Radix Angelicae Dahuricae (Baizhi, BZ) and Rhizoma Chuanxiong (ChuanXiong, CX) is a traditional herb couple. The combination performs better than the CX extract alone in the treatment of migraine and has been used for thousands of years. However, the specific compatibility mechanisms are still unclear. Ligustilide, dl ‐3‐n‐butylphthalide and senkyunolide A are the major active ingredients in CX and BZ–CX decoction. However, a comprehensive study of the pharmacokinetics of CX has not been carried out. A gas chromatography–mass spectroscopy (GC–MS) method with high selectivity, sensitivity and accuracy was developed. An SH‐Rxi‐5Sil (30 m × 0.25 mm i.d., and 0.25 μm film thickness) column was employed in the GC separation. Selectivity, linearity, precision, accuracy, recovery, matrix effect and stability were used to validate the current GC–MS method. Using the validated method, this is the first time to study on the comparative pharmacokinetics of ligustilide, dl ‐3‐n‐butylphthalide and senkyunolide A from CX alone and BZ–CX decoction in rat plasma. The pharmacokinetic parameters (Cmax, Tmax, T1/2, AUC0–t, AUC0–∞ and CLz/F) of all of the detected ingredients showed significant differences between the two groups (P < 0.05). The results are helpful for further investigation of the compatibility mechanism of BZ–CX decoction.  相似文献   

5.
An HPLC‐MS/MS method has been developed and validated for the determination of venlafaxine enantiomers in human plasma and applied to a pharmacokinetic study in healthy Chinese volunteers. The method was carried out on a vancomycin chiral column (5 µm, 250 × 4.6 mm) maintained at 25°C. The mobile phase was methanol–water containing 30 mmol/L ammonium acetate, pH 3.3 adjusted with aqueous ammonia (8:92, v/v) at the flow rate 1.0 mL/min. A tandem mass spectrometer with an electrospray interface was operated in the multiple reaction monitoring mode to detect the selected ions pair at m/z 278.0 → 120.8 for venlafaxine enantiomers and m/z 294.8 → 266.7 for estazolanm (internal standard). The method was linear in the concentration range of 0.28–423.0 ng/mL. The lower limit of quantification was 0.28 ng/mL. The intra‐and inter‐day relative standard deviations were less than 9.7%. The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine enantiomers in 18 healthy volnteers. Validation parameters such as the specificity, linearity, precision, accuracy and stability were evaluated, giving results within the acceptable range. Pharmacokinetic parameters of the venlafaxine enantiomers were measured in the 18 healthy Chinese volunteers who received a single regimen with venlafaxine hydrochloride capsules. The results show that AUC(0–∞), Cmax and t1/2 between S‐venlafaxine and R‐venlafaxine are significantly different (p < 0.05). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
The validation of a high throughput and specific method using a high‐performance liquid chromatography coupled to electrospray (ES+) ionization tandem triple quadrupole mass spectrometric (LC‐ESI‐MS/MS) method for ondansetron quantification in human plasma is described. Human plasma samples were extracted by liquid–liquid extraction (LLE) using methyl tert‐butyl ether and analyzed by LC‐ESI‐MS/MS. The limit of quantification was 0.2 ng/mL and the method was linear in the range 0.2–60 ng/mL. The intra‐assay precisions ranged from 1.6 to 7.7%, while inter‐assay precisions ranged from 2.1 to 5.1%. The intra‐assay accuracies ranged from 97.5 to 108.2%, and the inter‐assay accuracies ranged from 97.3 to 107.0%. The analytical method was applied to evaluate the relative bioavailability of two pharmaceutical formulations containing 8 mg of ondansetron each in 25 healthy volunteers using a randomized, two‐period crossover design. The geometric mean and respective 90% confidence interval (CI) of ondansetron test/reference percent ratios were 90.15% (81.74–99.44%) for Cmax and 93.11% (83.01–104.43%) for AUC0–t. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for Cmax and AUC0‐inf, it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of ondansetron. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A simple LC–MS/MS method facilitated by salting‐out assisted liquid–liquid extraction (SALLE) was applied to simultaneously investigate the pharmacokinetics of trans‐ resveratrol (Res) and its major glucuronide and sulfate conjugates in rat plasma. Acetonitrile–methanol (80:20, v /v) and ammonium acetate (10 mol L−1) were used as extractant and salting‐out reagent to locate the target analytes in the supernatant after the aqueous and organic phase stratification, then the analytes were determined via gradient elution by LC–MS/MS in negative mode in a single run. The analytical method was validated with good selectivity, acceptable accuracy (>85%) and low variation of precision (<15%). SALLE showed better extraction efficiency of target glucuronide and sulfate conjugates (>80%). The method was successfully applied to determine Res and its four conjugated metabolites in rat after Res administration (intragastric, 50 mg kg−1; intravenous, 10 mg kg−1). The systemic exposures to Res conjugates were much higher than those to Res (AUC0–t , i.v., 7.43 μm h; p.o., 8.31 μm h); Res‐3‐O‐β ‐d ‐glucuronide was the major metabolite (AUC0–t , i.v., 66.1 μm h; p.o., 333.4 μm h). The bioavailability of Res was estimated to be ~22.4%. The reproducible SALLE method simplified the sample preparation, drastically improved the accuracy of the concomitant assay and gave full consideration of extraction recovery to each target analyte in bio‐samples.  相似文献   

8.
In this study, we used a self‐contrast method, which excluded the individual difference, to evaluate the inhibitory effect of chrysosplentin (CHR) in the presence or absence of artemisinin (ART) on the P‐glycoprotein (P‐gp) transport activity. A sensitive and rapid UHPLC–MS/MS method was applied for quantification of digoxin, a P‐gp‐specific substrate, in rat plasma. A pharmacokinetic study was carried out: first after an oral administration of digoxin at a dose of 0.09 mg/kg (first period), followed by a 20‐day wash‐out, then after another administration of digoxin (second period). During the second period, test compounds were orally given three times per day for seven consecutive days. Results showed that the t1/2 of digoxin in all the groups had no significant difference between the first and second periods. The AUC0–24, Cmax, tmax, and Clz/F of the negative control and ART alone groups showed no difference. However, the AUC0–24 and Cmax in the CHR alone, CHR–ART (1:2) and verapamil (positive control) groups showed 2.34‐, 3.04‐, 1.79‐, and 1.81‐, 1.99‐, 2.06‐fold increases along with 3.50‐, 3.84‐ and 4.76‐fold decreases for CLz/F, respectively. The tmax in the CHR–ART (1:2) group increased 3.73‐fold. In conclusion, our self‐contrast study suggested that CHR, especially when combined with ART in a ratio of 1:2, inhibited P‐gp activity while ART alone has no effect. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive high‐performance liquid chromatography–mass spectrometric (HPLC‐MS) method was developed and validated for simultaneous determination of benzoylhypaconine (BHA), benzoylmesaconine (BMA), benzoylaconine (BAC) and hypaconitine (HA) in rat plasma for the first time. The analytes were separated on a Kromasil C18 column with a total running time of 11 min. The validation data demonstrated a sound feasibility for the newly developed method and it was then applied to the pharmacokinetic study of these analytes in rats. Pharmacokinetic behaviors of BHA, BMA, BAC and HA in rats were studied after oral administration of Radix Aconiti Lateralis Praeparata extract (FZ) and Dahuang Fuzi Decoction (DFD). The main parameters for the two groups of subjects were compared, and significant differences between Radix Aconiti Lateralis Praeparata extract group and Dahuang Fuzi Decoction group in calculated parameters, such as the area under the plasma concentration–time from zero to the last quantifiable time‐point (AUC0–t), the area under the plasma concentration–time curve from zero to infinity (AUC0–∞), peak plasma concentration (Cmax), half‐life of elimination (T1/2), mean retention time (MRT0–t), plasma clearance (CL), volume of distribution (Vd) and time to reach Cmax (Tmax), were found. After oral administration of DFD, the AUC0–t, AUC0–∞ and Cmax of BHA, BMA, BAC and HA decreased remarkably (p < 0.05) compared with those of the FZ extract group. Vd and CL values of BHA, BMA, BAC and HA increased, two of which showed significant difference (p < 0.05). T1/2 and MRT0–t values of BHA, BMA and BAC in the DFD group were significantly delayed compared with those of FZ extract group. Only the Tmax of HA, the toxic ingredient in FZ, delayed significantly in DFD group compared with the value of FZ group. All these pharmacokinetic parameters were statistically compared, and the rationality of the combination for DFD was clearly demonstrated. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A sensitive and specific LC‐MS/MS method was developed for simultaneous determination of aloe‐emodin, rhein, emodin, chrysophanol and physcion and their conjugates in rat plasma. The lower limit of quantitation of each anthraquinone was 0.020–0.040 µm . Intra‐day and inter‐day accuracies were 90.1–114.3% and the precisions were <14.6%. The matrix effects were 104.0–113.2%. The method was successfully applied to a pharmacokinetic study in rats receiving a rhubarb extract orally. The area under the concentration–time curve (AUC0–t) and peak concentration (Cmax) of free aloe‐emodin and emodin in rat plasma were much lower than those of rhein. The amounts of chrysophanol and physcion were too low to be continuously detected. After treating the plasma samples with β‐glucuronidases, each anthraquinone was detectable throughout the experimental period (36 h) and showed much higher plasma concentrations and AUC0–t. The free/total ratios of aloe‐emodin, rhein and emodin were 6.5, 49.0 and 1.7% for Cmax and 3.7, 32.5 and 1.1% for AUC0–t, respectively. The dose‐normalized AUC0–t and Cmax of the total of each anthraquinone were in the same descending order: rhein > emodin > chrysophanol > physcion > aloe‐emodin. These findings reveal phase II conjugates as the dominant in vivo existing forms of rhubarb antharquinones and warrant a further study to evaluate their contribution to the herbal activity. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
A simple, rapid, specific and reliable UFLC coupled with ESI‐MSMS assay method to simultaneously quantify sildenafil and N‐desmethyl sildenafil, with loperamide as internal standard, was developed. Chromatographic separation was performed on a Thermo Scientific Accucore C18 column with an isocratic mobile phase composed of 0.1% v/v formic acid in purified water–methanol (20:80, v/v), at a flow rate of 0.3 mL/min. Sildenafil, N‐desmethyl sildenafil and loperamide were detected with proton adducts at m/z 475.4 > 58.2, 461.3 > 85.2 and 477.0 > 266.1 in multiple reaction monitoring positive mode, respectively. Both analytes and internal standard were extracted by diethyl ether. The method was validated over a linear concentration range of 10–800 ng/mL for sildenafil and 10–600 ng/mL for N‐desmethyl sildenafil with correlation coefficient (r2) ≥0.9976 for sildenafil and (r2) ≥0.9992 for N‐desmethyl sildenafil. The method was precise, accurate and stable. The proposed method was applied to study the bioequivalence between a 100 mg dose of two pharmaceutical products: Viagra (original) and Edyfil (generic) products. AUC0–t, Cmax and Tmax were 2285.79 ng h/mL, 726.10 ng/mL and 0.94 h for Viagra and 2363.25 ng h/mL, 713.91 ng/mL and 0.83 hour for Edyfil. The 90% confidence interval of these parameters of this study fall within the regulatory range of 80–125%, hence they are considered as bioequivalent. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

13.
Lizhong decoction (LZD), a classic formula, has been used to treat ulcerative colitis (UC) for thousands of years in clinical practice. However, the pharmacokinetic characteristics of its major bioactive components in rats under different physiological and pathological states are not clear. Thus, in this study, a rapid and sensitive analytical method, ultra‐performance liquid chromatography coupled with mass spectrometry (UPLC–MS/MS) method, was developed and applied to simultaneously determine glycyrrhizic acid, liquiritin, isoliquiritin, glycyrrhizin, isoliquiritigenin, 6‐gingerol, ginsenoside Rg1, ginsenoside Rb1 and ginsenoside Re in normal and UC rats after oral administration of LZD extract. A Waters BEH C18 UPLC column was used for chromatographic separation, while acetonitrile and 0.1% formic acid were selected as mobile phase. The linearity of nine analytes was >0.9920. Inter‐ and intra‐day accuracy was ≤ 11.4% and precision was from 1.1 to 12.7%. Additionally, stable and suitable extraction recoveries were also obtained. The established method was validated and found to be specific, accurate and precise for nine analytes. Furthermore, it was successfully applied to the pharmacokinetic investigation of nine major components after oral administration of LZD extracts to normal and model rats, respectively. The results showed that the pharmacokinetic parameters (Cmax, Tmax, AUC0–t, AUC0–∞) in the plasma of UC rats were significantly different from those of normal rats, which could provide a reference for the clinical application of LZD.  相似文献   

14.
The objectives of this study were to develop a new deproteinization method to extract amoxicillin from human plasma and evaluate the inter‐ethnic variation of amoxicillin pharmacokinetics in healthy Malay volunteers. A single‐dose, randomized, fasting, two‐period, two‐treatment, two‐sequence crossover, open‐label bioequivalence study was conducted in 18 healthy Malay adult male volunteers, with one week washout period. The drug concentration in the sample was analyzed using high‐performance liquid chromatography (UV–vis HPLC). The mean (standard deviation) pharmacokinetic parameter results of Moxilen® were: peak concentration (Cmax), 6.72 (1.56) µg/mL; area under the concentration–time graph (AUC0–8), 17.79 (4.29) µg/mL h; AUC0–∞, 18.84 (4.62) µg/mL h. Those of YSP Amoxicillin® capsule were: Cmax, 6.69 (1.44) µg/mL; AUC0–8, 18.69 (3.78) µg/mL h; AUC00–∞, 19.95 (3.81) µg/mL h. The 90% confidence intervals for the logarithmic transformed Cmax, AUC0–8 and AUC0–∞ of Moxilen® vs YSP Amoxicillin® capsule was between 0.80 and 1.25. Both Cmax and AUC met the predetermined criteria for assuming bioequivalence. Both formulations were well tolerated. The results showed significant inter‐ethnicity variation in pharmacokinetics of amoxicillin. The Cmax and AUC of amoxicillin in Malay population were slightly lower compared with other populations. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
A highly sensitive and selective method using LC‐ESI‐MS/MS and tandem‐SPE was developed to detect trace amounts of avoparcin (AV) antibiotics in animal tissues and milk. Data acquisition using MS/MS was achieved by applying multiple reaction monitoring of the product ions of [M + 3H]3+ and the major product ions of AV‐α and ‐β at m/z 637 → 86/113/130 and m/z 649 → 86/113/130 in ESI(+) mode. The calculated instrumental LODs were 3 ng/mL. The sample preparation was described that the extraction using 5% TFA and the tandem‐SPE with an ion‐exchange (SAX) and InertSep C18‐A cartridge clean‐up enable us to determine AV in samples. Ion suppression was decreased by concentration rates of each sample solution. These SPE concentration levels could be used to detect quantities of 5 ppb (milk), 10 ppb (beef), and 25 ppb (chicken muscle and liver). The matrix matching calibration graphs obtained for both AV‐α (r >0.996) and ‐β (r >0.998) from animal tissues and milk were linear over the calibration ranges. AV recovery from samples was higher than 73.3% and the RSD was less than 12.0% (n = 5).  相似文献   

16.
Sarsasapogenin-AA13(AA13), a sarsasapogenin derivative, exhibited good neuroprotective and anti-inflammatory activities in vitro and therapeutic effects on learning and memory dysfunction in amyloid-β-injected mice. A sensitive UPLC–MS/MS method was developed and validated to quantitatively determine AA13 in rat plasma and was further applied to evaluate the pharmacokinetic behaviour of AA13 in rats that were administered AA13 intravenously and orally. This method was validated to exhibit excellent linearity in the concentration range of 1–1000 ng/mL. The lower limit of quantification was 1 ng/mL for AA13 in rat plasma. Intra-day accuracy for AA13 was in the range of 90–114%, and inter-day accuracy was in the range of 97–103 %. The relative standard deviation of intra-day and inter-day assay was less than 15%. After a single oral administration of AA13 at the dose of 25 mg/kg, Cmax of AA13 was 1266.4 ± 316.1 ng/mL. AUC0–48 h was 6928.5 ± 1990.1 h·ng/mL, and t1/2 was 10.2 ± 0.8 h. Under intravenous administration of AA13 at a dosage of 250 μg/kg, AUC0–48 h was 785.7 ± 103.3 h⋅ng/mL, and t1/2 was 20.8 ± 7.2 h. Based on the results, oral bioavailability (F %) of AA13 in rats at 25 mg/kg was 8.82 %.  相似文献   

17.
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether–dichloromethane, 80:20, v/v) and analyzed by HPLC‐ESI‐MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH4OH on a Gemini Phenomenex C8 5 μm column (50 × 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05–10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra‐batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter‐batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine®, Schering‐Plough). The study was conducted using an open, randomized, two‐period crossover design with a 2 week washout interval. Since the 90% confidence interval for Cmax and AUC ratios were all within the 80–125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid dispersive micro‐solid phase extraction (D‐μ‐SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM‐41 was used as sorbent in d ‐μ‐SPE of the azole compounds from biological fluids. Important D‐μ‐SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB‐C18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile–0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v /v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1–10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra‐ and inter‐day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3–114.8%. The MCM‐41‐D‐μ‐SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis.  相似文献   

19.
Systemic arterial hypertension is a major risk factor for cerebrovascular disease. Therefore, adequate control of blood pressure is of enormous importance. One of the many fixed‐dose single‐pill antihypertensive formulations available on the market is the combination of nebivolol and hydrochlorothiazide. The objective of this study was to develop two distinct high‐performance liquid chromatography coupled to tandem mass spectrometry methods to simultaneously quantify nebivolol and hydrochlorothiazide in human plasma. The methods were employed in a bioequivalence study, the first assay involving a nebivolol fixed‐dose single‐pill formulation based on healthy Brazilian volunteers. Nebilet HCT™ (nebivolol 5 mg + hydrochlorothiazide 12.5 mg tablet, manufactured by Menarini) was the test formulation. The reference formulations were Nebilet™ (nebivolol 5 mg tablet, manufactured by Menarini) and Clorana™ (hydrochlorothiazide 25 mg tablet, manufactured by Sanofi). For both analytes, liquid–liquid extraction was employed for sample preparation and the chromatographic run time was 3.5 min. The limits of quantification validated were 0.02 ng/mL for nebivolol and 1 ng/mL for hydrochlorothiazide. Since the 90% CI for C max, AUC(0–last) and AUC(0–inf) individual test/reference ratios were within the 80–125% interval indicative of bioequivalence, it was concluded that Nebilet HCT™ is bioequivalent to Nebilet™ and Clorana™.  相似文献   

20.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号