1.
Gaseous benzene, toluene, ethylbenzene and o‐xylene (BTEX) were extracted by using the divinylbenzene (DVB) particles (mesh sizes 60–80, 80–100 and 100–120) as sorbents packed in passive needle trap samplers (NTS). This study performed feasibility tests of these self‐designed DVB‐NTS as diffusive time‐weighted average (TWA) samplers and compared extraction efficiency with that of 100 mm polydimethylsiloxane‐solid phase microextration (PDMS‐SPME) fiber for sampling gaseous and particle‐bound volatile organic compounds (VOCs) from burning mosquito coils. Experimental results indicated that extraction rate of NTS is a reliable index in extracting VOCs. Additionally, comparisons of the NTS in extracting BTEX mass showed the NTS packed with the smallest diameters of adsorbent particles (100–120 mesh DVB) were the most effective. The mass of gaseous BTEX extracted by 100 μm PDMS‐SPME fiber were substantially lower than that extracted by DVB‐NTS of all meshes for the 30‐min TWA sampling of burning mosquito coils, and NTS packed with 100–120 mesh DVB adsorbed BTEX 50–120 ng BTEX. Particles clogging inside the packed phase of NTS inhibited VOC extraction performance after 3–5 samplings of burning particles, especially NTS packed with small‐diameter adsorbents.  相似文献   

2.
A highly porous fiber coated with polythiophene/hexagonally ordered silica nanocomposite was prepared for solid‐phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless‐steel wire for the fabrication of the SPME fiber. Polythiophene/hexagonally ordered silica nanocomposite fibers were used for the extraction of some polycyclic aromatic hydrocarbons from water samples. The extracted analytes were transferred to the injection port of a gas chromatograph using a laboratory‐designed SPME device. The results obtained prove the ability of the polythiophene/hexagonally ordered silica material as a new fiber for the sampling of organic compounds from water samples. This behavior is due most probably to the increased surface area of the polythiophene/hexagonally ordered silica nanocomposite. A one‐at‐a‐time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. Under the optimum conditions, the LOD of the proposed method is 0.1–3 pg/mL for analysis of polycyclic aromatic hydrocarbons from aqueous samples, and the calibration graphs were linear in a concentration range of 0.001–20 ng/mL (R2 > 0.990) for most of the polycyclic aromatic hydrocarbons. The single fiber repeatability and fiber‐to‐fiber reproducibility were less than 8.6 and 19.1% (n = 5), respectively.  相似文献   

3.
Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography–mass spectrometry (GC–MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.  相似文献   

4.
In this paper solid phase microextraction (SPME) and needle trap device (NTD) as two in-progress air monitoring techniques was applied with silylated composite of carbon nanotubes for sampling and analysis of perchloroethylene in air. Application of SPME and NTD with proposed nano-structured sorbent was investigated under different laboratory and experimental parameters and compared to the SPME and NTD with CAR/PDMS. Finally the two samplers contained nano-sorbent used as a field sampler for sampling and analysis of perchloroethylene in dry cleaning. Results revealed that silica composite form of CNTs showed better performance for adsorbent of perchloroethylene. SPME and NTD with proposed sorbent was demonstrated better responses in lower levels of temperature and relative humidity. For 5 days from sampling the relative responses were more than 97% and 94% for NTD and SPME, respectively. LOD were 0.023 and 0.014 ng mL−1 for SPME coated CNTs/SC and CAR/PDMS, and 0.014 and 0.011 ng mL−1 for NTD packed with CNTs/SC and CAR/PDMS, respectively. And for consecutive analysis RSD were 3.9–6.7% in laboratory and 4.43–6.4% in the field. In the field study, NTD was successfully applied for determining of the PCE in dry cleaning. The results show that the NTD packed with nanomaterial is a reliable and effective approach for the sampling and analysis of volatile compounds in air.  相似文献   

5.
On-site sampling and sample preparation favor portable, solventless or even solvent-free techniques. Solid-phase microextraction (SPME) has these advantages. This review focuses on developments between 2007 and early 2011 in microextraction techniques for on-site sampling and sample preparation, including fiber SPME, stir-bar sorptive extraction (SBSE), thin-film microextraction (TFME) and different types of in-needle SPME. The major trends in on-site applications of SPME appear to be fiber and thin-film SPME, microextraction by packed sorbent (MEPS) and the sorbent-packed needle-trap device (NTD). We discuss and compare several aspects of these types of SPME in on-site applications. We also describe sorbent phases for SPME that benefit on-site applications. Finally, we provide a perspective on SPME-based techniques for on-site applications.  相似文献   

6.
The construction of a new solid-phase microextraction/surfaced enhanced laser desorption/ionization-ion mobility spectrometry (SPME/SELDI-IMS) device is reported here. A polypyrrole (PPY) coated SPME/SELDI fiber was employed as the extraction phase and SELDI surface to introduce analytes into the IMS. Analytes were directly ionized from the PPY coated fiber tip by a Nd:YAG laser without the addition of a matrix. Optimal experimental parameters, such as extraction conditions and laser parameters, were investigated. The use of a SPME/SELDI fiber simplified the sampling and sample preparation for IMS. Verapamil could be directly extracted from urine sample and analyzed by IMS without any further sample cleanup. This technique could be used for the analysis of drugs and other non-volatile compounds.  相似文献   

7.
In this study, the experimental extraction conditions on applying headspace solid‐phase microextraction and cold fiber headspace solid‐phase microextraction (CF‐HS‐SPME) procedures to samples of six medicinal herbs commonly found in southern Brazil were optimized. The optimized conditions for headspace solid‐phase microextraction were found to be an extraction temperature of 60°C and extraction time of 40 min. For CF‐HS‐SPME, the corresponding values were 60°C and 15 min. In the case of the coating temperature for the CF‐HS‐SPME system, two approaches were investigated: (i) Temperature of 5°C applied during the whole extraction procedure; and (ii) the use of two fiber temperatures in the same extraction procedure with the aim of extracting the volatile and semivolatile compounds, the ideal condition being 60°C for the first 7.5 min and 5°C for the final 7.5 min. The three extraction procedures were compared. The CF‐HS‐SPME procedure had good performance only for the more volatile compounds whereas the strategy using two coating temperatures in the same procedure showed good performance for all compounds studied. It was also possible to determine the profile for the volatile fraction of each herb studied applying this technique followed by GC‐MS.  相似文献   

8.
A fiber‐in‐tube solid‐phase microextraction device based on a gold‐functionalized stainless‐steel wire and tube was developed and characterized by scanning electron microscopy and energy dispersive X‐ray spectroscopy. In combination with high‐performance liquid chromatography, it was evaluated using six polycyclic aromatic hydrocarbons as model analytes. Important parameters including sampling rate, sample volume, organic solvent content and desorption time were investigated. Under optimized conditions, an online analysis method was established. The linearity was in the range of 0.15–50 μg/L with correlation coefficients ranging from 0.9989 to 0.9999, and limits of detection ranged from 0.05 to 0.1 μg/L. The method was applied to determine model analytes in mosquito‐repellent incense ash and river water samples, with recoveries in the range of 85–120%.  相似文献   

9.
In this study, a needle‐trap device with fibers coated with a molecularly imprinted polymer was developed for separation. A number of heat‐resistant Zylon filaments were longitudinally packed into a glass capillary, followed by coating with a molecularly imprinted polymer. Then, the molecularly imprinted polymer coating was copolymerized and anchored onto the surface of the fibers. The bundle of synthetic fibers coated with the molecularly imprinted polymer was packed into a 21G stainless‐steel needle and served as an extraction medium. The coated‐fiber needle extraction device was used to extract volatile organic compounds from paints and gasoline effectively. Subsequently, the extracted volatile organic compounds were analyzed by gas chromatography. Calibration curves of gaseous benzene, toluene, ethylbenzene, and o‐xylene in the concentration range of 1–250 μg/L were obtained to evaluate the method, acceptable linearity was attended with correlation coefficients above 0.998. The limit of detection of benzene, toluene, ethylbenzene, and o‐xylene was 11–20 ng/L using the coated‐fiber needle‐trap device. The relative standard deviation of needle‐to‐needle repeatability was less than 8% with an extraction time of 20 min. The loss rates after storage for 3 and 7 days at room temperature were less than 30%.  相似文献   

10.
A needle trap device (NTD) packed with silica composite of multi-walled carbon nanotubes (MWCNTs) prepared based on sol–gel technique was utilized for sampling and analysis of volatile organohalogen compounds (HVOCs) in air. The performance of the NTD packed with MWCNTs/silica composite as sorbent was examined in a variety of sampling conditions and was compared with NTDs packed with PDMS as well as SPME with Carboxen/PDMS-coated fibers. The limit of detection of NTDs for the GC/MS detection system was 0.01–0.05 ng mL−1 and the limit of quantitation was 0.04–0.18 ng mL−1. The RSD were 1.1–7.8% for intra-NTD comparison intended for repeatability of technique. The NTD-MWCNTs/silica composite showed better analytical performances compared to the NTD-PDMS composite and had the same analytical performances when compared to the SPME-Carboxen/PDMS fibers. The results show that NTD-MWCNTs-GC/MS is a powerful technique for active sampling of occupational/environmental pollutants in air.  相似文献   

11.
A new SPME fiber based on mixture of zeolite and silicon carbide in PVC matrix was made and its application for sampling of BTEX compounds from headspace of water and soil samples was studied. After optimization of conditions, the proposed fiber was used for determination of BTEX in real samples obtained from rivers and soils of gasoline reservoirs surroundings. The method has good linearity (0.991‐0.999) over wide concentration range. Detection limits of the method are in the range of 0.66–1.66 μg L? and 0.01–0.12 μg kg? for water and soil samples, respectively.  相似文献   

12.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

13.
A new approach is described to capture nano‐size aerosols on internally‐cooled micro tubing of the solid‐phase microextraction (SPME) device followed by convenient introduction of the collected analytes into analytical instrument. Particles were generated using an aerosol formation by homogeneous nucleation of an organic vapor, and subsequent growth to nano‐size particles by coagulation of decanedioic acid, bis[2‐ethylhexyl] ester (DEHS). The approach was validated by using carbon dioxide‐cooled micro tubing to collect the nanosize DEHS particles followed by analyses on GC‐flame ionization detector (FID). Particle size ranged from 150 to 590 nm. Temperature difference between the SPME device and DEHS particles mixture created a temperature gradient and resulted in thermophoretic effect that was determining the extraction rate. SPME device was cooled to as low as –75°C, while the DEHS remained close to room temperature. Several aspects of nanoparticle sampling were tested to demonstrate the principle of the sampling approach. These included the effects of thermal gradient, sample flow rate, sampling time, CO2 delivery mode (constant coolant delivery vs. constant temperature), and particle size. Results were normalized to measure particulate concentrations using direct sampling with PTFE filters. Nanoparticle extractions of DEHS mass were proportional to sampling time. Normalized mass of DEHS extracted increased with increase in temperature gradient and with increase of the cross flow velocity. Preliminary results indicate that the variation of heat transfer boundary layer caused by the variation in the cross flow velocity produce self‐compensating effect at constant coolant delivery, indicating that this approach could be used for field determinations including the time‐weighted average sampling of nanoparticles. Thus, it may be possible to develop simple device based on this concept for field applications.  相似文献   

14.
A method was developed for the analysis of volatile polar compounds in a water matrix using open cap vials Solid Phase Micro-Extraction (SPME) and Capillary Gas Chromatography (CGC). Both SPME techniques – direct sampling and headspace – were tested. Optimization of experimental conditions – exposure time, desorption time, with headspace SPME in addition the influence of the temperature and ionic strength of the sample solution on compound sorption, and finally GC response – were investigated. The analytes were extracted by directly immersing the 85 μm polyacrylate fiber in the aqueous sample or in the headspace. The linear range of the preconcentration process and the precision were examined. The amount of polar analytes sorbed on the fiber was determined and was found to be concentration dependent; it amounted to 0.014–0.64% in the concentration range of 0.00425–425 ppm studied in aqueous solution for direct sampling SPME and to 0.011–2.76% for solutions of concentration 0.0425–255 ppm for headspace SPME. The limits of determination were ascertained. Headspace SPME was applied to the analysis of real-life samples.  相似文献   

15.
Headspace solid phase microextraction (headspace SPME) has been demonstrated to be an excellent solvent-free sampling method. One of the major factors contributing to the success of headspace SPME is the concentrating effect of the fiber coating toward organic compounds. The affinity of the fiber coating toward very volatile analytes, such as chloromethane, may, however, not be large enough for detection at the parts per trillion concentration level. Static headspace analysis, on the other hand, is very effective for these very volatile compounds. As analyte volatility decreases, the sensitivity of static headspace analysis drops. The complementary nature of these two sampling methods can be exploited by combining the SPME device with a gastight syringe. The sensitivity of the new sampling device is better than that of SPME for very volatile compounds or that of static headspace analysis for less volatile compounds. This new method can sample a wide range of compounds from chloromethane (b.p. −24°C) to bromoform (b.p. 149°C) with estimated limits of detection at the low parts per trillion level.  相似文献   

16.
Nanoporous silica was prepared and functionalized with amino propyl‐triethoxysilane to be used as a highly porous fiber‐coating material for solid‐phase microextraction (SPME). The prepared nanomaterials were immobilized onto a stainless steel wire for fabrication of the SPME fiber. The proposed fiber was evaluated for the extraction of volatile component of Citrus aurantium L. leaves. A homemade microwave‐assisted extraction followed by headspace (HS) solid‐phase apparatus was used for the extraction of volatile components. For optimization of factors affecting the extraction efficiency of the volatile compounds, a simplex optimization method was used. The repeatability for one fiber (n = 4), expressed as RSD, was between 3.1 and 8.6% and the reproducibility for five prepared fibers was between 10.1 and 14.9% for the test compounds. Using microwave‐assisted distillation HS‐SPME followed by GC‐MS, 53 compounds were separated and identified in C. aurantium L., which mainly included limonene (62.0%), linalool (7.47%), trans‐β‐Ocimene (3.47%), and caryophyllene (2.05%). In comparison to a hydrodistillation method, the proposed technique could equally monitor almost all the components of the sample, in an easier way, which was rapid and required a much lower amount of sample.  相似文献   

17.
Static and dynamic headspace sampling have been applied for the enrichment of volatiles emitted by living plants. For solid phase microextraction (SPME) the sorptive fibers polydimethylsiloxane (PDMS) and polyacrylate (PA) have been compared and, in accordance with the like‐like principle, polar compounds exhibit more affinity for the PA fiber while apolar solutes favor the PDMS fiber. For dynamic sampling, tubes packed with PDMS particles show greater inertness than Tenax; some Tenax decomposition products, e.g. benzaldehyde and acetophenone, interfere with the analyses. With PDMS particles operated in the breakthrough mode, the obtained profiles are similar to those obtained by SPME on the PA fiber. Recoveries relative to a packed PDMS bed are 85% for Tenax, 2.4% for SPME‐PDMS, and 6.2% for SPME‐PA.  相似文献   

18.
Volatile organic compounds (VOCs) emitted from in vitro cultures may reveal information on species and metabolism. Owing to low nmol L−1 concentration ranges, pre‐concentration techniques are required for gas chromatography–mass spectrometry (GC–MS) based analyses. This study was intended to compare the efficiency of established micro‐extraction techniques – solid‐phase micro‐extraction (SPME) and needle‐trap micro‐extraction (NTME) – for the analysis of complex VOC patterns. For SPME, a 75 μm Carboxen®/polydimethylsiloxane fiber was used. The NTME needle was packed with divinylbenzene, Carbopack X and Carboxen 1000. The headspace was sampled bi‐directionally. Seventy‐two VOCs were calibrated by reference standard mixtures in the range of 0.041–62.24 nmol L−1 by means of GC–MS. Both pre‐concentration methods were applied to profile VOCs from cultures of Mycobacterium avium ssp. paratuberculosis. Limits of detection ranged from 0.004 to 3.93 nmol L−1 (median = 0.030 nmol L−1) for NTME and from 0.001 to 5.684 nmol L−1 (median = 0.043 nmol L−1) for SPME. NTME showed advantages in assessing polar compounds such as alcohols. SPME showed advantages in reproducibility but disadvantages in sensitivity for N‐containing compounds. Micro‐extraction techniques such as SPME and NTME are well suited for trace VOC profiling over cultures if the limitations of each technique is taken into account.  相似文献   

19.
In‐syringe solid‐phase extraction is a promising sample pretreatment method for the on‐site sampling of water samples because of its outstanding advantages of portability, simple operation, short extraction time, and low cost. In this work, a novel in‐syringe solid‐phase extraction device using metal–organic frameworks as the adsorbent was fabricated for the on‐site sampling of polycyclic aromatic hydrocarbons from environmental waters. Trace polycyclic aromatic hydrocarbons were effectively extracted through the self‐made device followed by gas chromatography with mass spectrometry analysis. Owing to the excellent adsorption performance of metal–organic frameworks, the analytes could be completely adsorbed during one adsorption cycle, thus effectively shortening the extraction time. Moreover, the adsorbed analytes could remain stable on the device for at least 7 days, revealing the potential of the self‐made device for on‐site sampling of degradable compounds in remote regions. The limit of detection ranged from 0.20 to 1.9 ng/L under the optimum conditions. Satisfactory recoveries varying from 84.4 to 104.5% and relative standard deviations below 9.7% were obtained in real samples analysis. The results of this study promote the application of metal–organic frameworks in sample preparation and demonstrate the great potential of in‐syringe solid‐phase extraction for the on‐site sampling of trace contaminants in environmental waters.  相似文献   

20.
A new diffusion-based solid-phase microextraction (SPME) time-weighted average (TWA) field water sampling device was developed and investigated by field trial. The sampler is constructed with copper tube and caps and a commercial SPME fiber assembly. The device possesses all advantages of SPME; it is solvent-free, reusable, combines sampling, isolation and enrichment into one step, and the fiber can be directly injected into a gas chromatograph for analysis with a commercial SPME fiber holder, without further treatment. Field trials in Laurel Creek (Waterloo, Ont., Canada) and Hamilton Harbour (Hamilton, Ont., Canada) illustrated that the device is durable, easy to deploy, and the mass uptake of the device is independent of the face velocity. The device provides good precision [relative standard deviations (RSDs) are less than 20%] and the data obtained with this device are quite comparable to those obtained with the spot sampling method, which demonstrates that the newly developed SPME water sampling device is suitable for long-term monitoring of organic pollutants in water.  相似文献   