首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The method employing molecularly imprinted polymers for the extraction and clean up of endocrine‐disrupting compounds (estrogens, bisphenol A, and alkylphenols) from water and sediment is described. The identical extraction/clean‐up and LC‐MS/MS condition were used for the analysis of both types of samples. The method showed high recoveries ranging from 90 to 99% with excellent precision (intrabatch: 3.6–9.3%; interbatch: 5.6–11.4% for water; intrabatch: 4.3–8.5%; interbatch: 6.1–9.6% for sediment). The LOD was in the range of 0.7–1.9 ng/L and 0.3–0.6 ng/g for water and sediment, respectively. Overall extraction on molecularly imprinted polymers substantially enhanced sample clean‐up. The difference in efficiency of clean‐up was particularly pronounced when a large sample volume/weight was extracted and analyzed. Finally, the method was successfully applied for the analysis of 20 water and sediment samples.  相似文献   

2.
A selective molecularly imprinted solid-phase extraction (MISPE) for indomethacin (IDM) from water samples was developed. Using IDM as template molecule, acrylamide (AM) or methacrylic acid (MAA) as functional monomer, ethylene dimethacrylate (EDMA) as crosslinker, and bulk or suspension polymerization as the synthetic method, three molecularly imprinted polymers (MIPs) were synthesized and characterized with a rebinding experiment. It was found that the MIP of AM-EDMA produced by bulk polymerization showed the highest binding capacity for IDM, and so it was chosen for subsequent experiments, such as those testing the selectivity and recognition binding sites. Scatchard analysis revealed that at least two kinds of binding sites formed in the MIP, with the dissociation constants of 7.8 μmol L−1 and 127.2 μmol L−1, respectively. Besides IDM, three structurally related compounds — acemetacin, oxaprozin and ibuprofen — were employed for selectivity tests. It was observed that the MIP exhibited the highest selective rebinding to IDM. Accordingly, the MIP was used as a solid-phase extraction sorbent for the extraction and enrichment of IDM in water samples. The extraction conditions of the MISPE column for IDM were optimized to be: chloroform or water as loading solvent, chloroform with 20% acetonitrile as washing solution, and methanol as eluting solvent. Water samples with or without spiking were extracted by the MISPE column and analyzed by HPLC. No detectable IDM was observed in tap water and the content of IDM in a river water sample was found to be 1.8 ng mL−1. The extraction efficiencies of the MISPE column for IDM in spiked tap and river water were acceptable (87.2% and 83.5%, respectively), demonstrating the feasibility of the prepared MIP for IDM extraction. Figure Molecularly imprinted polymer-based solid-phase extraction for indomethacin  相似文献   

3.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

4.
岳春月  丁国生  唐安娜 《色谱》2013,31(1):10-14
依据分子印迹技术(MIT)制备的分子印迹聚合物(MIP)颗粒对模板分子及其结构类似物具有特异性识别和选择性吸附作用,同时具有较大的比表面积和快速的传质动力学特性,因而被广泛用作液相色谱固定相和固相萃取材料。将MIP颗粒作为固定相应用于毛细管电色谱(CEC),结合了CEC的快速、高效和MIP的高亲和性、高选择性的特点,成为分析科学领域最具有发展前景的分离技术之一。MIP颗粒在CEC领域有几种不同的应用形式: 作为填充材料填充到毛细管柱中;作为嵌入材料嵌入到毛细管柱内部不同基质的骨架中;作为准固定相添加到CEC运行缓冲溶液中。本文综述了近几年MIP颗粒在CEC领域应用的发展,对该领域今后的发展前景进行了展望。  相似文献   

5.
The synthesis and evaluation of a molecularly imprinted polymer (MIP) used as a selective solid-phase extraction sorbent and coupled to high-performance liquid chromatography (HPLC) for the efficient determination of sulfamerazine (SMR) in pond water and three fishes are reported. The polymer was prepared using SMR as the template molecule, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the crosslinking monomer in the presence of tetrahydrofuran as the solvent. The SMR-imprinted polymers and nonimprinted polymers were characterized by FT-IR and static adsorption experiments. The prepared SMR-imprinted material showed a high adsorption capacity, significant selectivity and good site accessibility. The maximum static adsorption capacities of the SMR-imprinted and nonimprinted materials for SMR were 108.8 and 79.6 mg g−1, respectively. The relative selectivity factor of this SMR-imprinted material was 1.6. Several parameters influencing the solid-phase extraction process were optimized. Finally, the SMR-imprinted polymers were used as the sorbent in solid-phase extraction to determine SMR in pond water and three fishes with satisfactory recovery. The average recoveries of the MIP-SPE method were 94.0% in ultrapure water and 95.8% in pond water. Relative standard deviations ranging from 0.3% to 5.2% in MIP were acquired. The results for the SMR concentrations in crucian, carp and wuchang fish were 66.0, 127.1 and 51.5 ng g−1, respectively. The RSDs (n = 5) were 3.51%, 0.53% and 5.08%, respectively. The limit of detection (LOD) for SMR was 1 ng g−1 and the limit of quantitation (LOQ) was 3.5 ng g−1.  相似文献   

6.
Shabi Abbas Zaidi 《Electrophoresis》2013,34(9-10):1375-1382
To extend the application of molecularly imprinted polymers, the dual‐templates molecularly imprinted monolithic columns were developed in a capillary format. Two templates serotonin and histamine were simultaneously imprinted using two different functional monomers such as methacrylic acid (MAA) and methylenesuccinic acid (MSA) in a mixture of ethylene glycol dimethacrylate (EDMA) as a cross‐linker and AIBN as polymerization initiator dissolved in DMF as porogen. The resulting molecular imprinted polymers (MIPs) were characterized based on their performance in the CEC separation of two imprinted templates. The optimization parameters such as pH, ACN composition, and concentration of the eluent were varied to achieve best resolution and efficiency for CEC separation of templates with each MIP column. It was found that the MIP monolith column fabricated using MSA offered better resolution and separation efficiency compared to column fabricated with MAA. This work utilized the dual‐templates imprinting approach successfully and broadens the scope of multi‐templates imprinting capabilities in capillary format in CEC application.  相似文献   

7.
We propose the use of Doehlert’s experimental design, a second-order uniform shell design, for the optimization of molecularly imprinted polymers (MIPs). We have chosen a simple model system where the influence of kind and degree of cross-linking on template recognition was studied using S-propranolol as the template. We found that Doehlert’s design allows—with very few experiments—one to screen the evolution of the binding capacity of a MIP as a function the different parameters, and thus appears to be a powerful means to screen for the best composition and synthesis method for MIPs. We believe that this chemometric tool can significantly accelerate the development of new MIPs as synthetic recognition elements, particularly in the context of a given application, and will be a versatile complement or alternative to first-order designs to fit complex processes. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

8.
A novel chemiluminescence (CL) microfluidic system incorporating a molecularly imprinted polymer (MIP) preconcentration step was used for the determination of chloramphenicol in honey samples. The MIP was prepared by using chloramphenicol as the template, diethylaminoethyl methacrylate (DAM) as the function monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linking monomer, 2, 2′-dimethoxy-2-phenylacetophenone (DMPA) as the free radical initiator and toluene and dodecanol as the solvent. The MIP was pre-loaded into a 10 mm long, 2 mm wide and 150 μm deep channel in a planar glass microfluidic device. When the sample containing chloramphenicol was introduced into the microfluidic device it was first preconcentrated on the MIP then detected by an enhancement effect on the chemiluminescence reaction of tris(2, 2′-bipyridyl) ruthenium(II) with cerium(IV) sulphate in sulphuric acid. A micro-syringe pump was used to pump the reagents. The CL intensity was linear in relationship to the chloramphenicol concentrations from 1.55 × 10−4 to 3.09 × 10−3 μmol L−1 (r2 = 0.9915) and the detection limit (3σ) and the quantitation limit (10σ) were found to be 7.46 × 10−6 and 2.48 × 10−5 μmol L−1, respectively. This method offered a high selectivity and sensitivity for quantitative analysis of chloramphenicol in the honey samples.  相似文献   

9.
A molecular simulation method was introduced to compute the phenol–monomer pre‐assembled system of a molecularly imprinted polymer. The interaction type and intensity between phenol and monomer were evaluated by combining binding energy and charge transfer with complex conformation. The simulation results indicate that interaction energies are simultaneously affected by the type of monomer and the ratio between phenol and monomers. At the same time, we considered that by increasing the amount of functional monomer is not always better for preparing molecularly imprinter polymers. In this study, three kinds of novel magnetic phenol‐imprinted polymers with favorable specific adsorption effects were prepared by the surface imprinting technique combined with atom transfer radical polymerization. Various measures were selected to characterize the structure and morphology to obtain the optimal polymer. The characterization results show that the optimal polymer has suitable features for further adsorption process. A series of static adsorption experiments were conducted to analyze its adsorption performance, which follows the Elovich model from the kinetic analysis and the Sips equation from the isothermal analysis. To further verify the reliability and accuracy of the simulation results, the effects of different monomers on the adsorption selectivity were also determined. They display higher selectivity towards phenol than 4‐nitrophenol.The results from the simulation of the pre‐assembled complexes are in reasonable agreement with those from the experiment.  相似文献   

10.
Continuous disposal of endocrine-disrupting compounds (EDCs) into the environment can lead to serious human health problems and can affect plants and aquatic organisms. The determination of EDCs in water has become an increasingly important activity due to our increased knowledge about their toxicities, even at low concentration. The EDCs in water samples from the reclaimed water plant of Tianjin, northern China, were identified by gas chromatography (GC)–mass spectrometry (MS). Important and contrasting EDCs including estrone (E1), 17β-estradiol (E2), 17α-ethynylestradiol (EE2), 4-tert-octylphenol (OP), 4-nonylphenol (NP), bisphenol A (BPA), di-n-butyl phthalate (DnBP), diisobutyl phthalate (DIBP), and di(2-ethylhexyl)phthalate (DEHP) were selected as the target compounds. Concentrations of steroid hormones, alkylphenolic compounds and phthalates ranged from below the limit of detection (LOD) to 8.1 ng L−1, from <LOD to 14.2 ng L−1, and from 1.00 μg L−1 to 23.8 μg L−1, respectively. The average removal efficiencies for target EDCs varied from 30% to 82%. These results indicate that environmental endocrine disrupting compounds are not completely removed during reclaimed water treatment and may be carried over into the general aquatic environment.  相似文献   

11.
A broad selective molecularly imprinted polymers-based solid phase extraction (MISPE) for levonorgestrel (LNG) from water samples was developed. Using LNG as a template molecule, acrylamide (AA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as linking agent and bulk polymerisation as a synthetic method, the molecularly imprinted polymers (MIPs) were synthesised and characterised. The MIPs displayed a high specific rebinding for LNG with the imprinting factor of 3.71. The Scatchard analysis showed that there was at least one class of binding site for LNG formed in the MIPs with the dissociation constant of 8.046?µg?mL?1. The results of selectivity testing indicated that the MIPs also exhibited high cross-reactivity with structurally related compounds (estrone, methylprednisolone and ethinyl estradiol), but no recognition with non-structurally related compound (indomethacin), suggesting that the MIPs could be used as a broad recognition absorbent. MISPE column was prepared by packing MIPs particles into a common SPE cartridge. The MISPE extraction conditions including loading, washing and eluting solutions were carefully optimised. Water samples spiked with LNG were extracted by MISPE column and detected by high-performance liquid chromatography. The recoveries were found to be 79.97?~?132.79% with relative standard deviations (RSD) of 1.92?~?10.43%, indicating the feasibility of the prepared MIPs for LNG extraction.  相似文献   

12.
《Analytical letters》2012,45(18):2896-2913
Abstract

A highly selective and effective method for the purification and preconcentration of norfloxacin (NFX) in seawater samples was developed based on molecularly imprinted solid-phase extraction (MISPE). The molecularly imprinted polymer was synthesized by precipitation polymerization. Methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were used as the functional monomer and crosslinker, respectively. The resulting molecularly imprinted polymer (MIP) showed high adsorption for NFX and was selective for its solid-phase extraction. An offline MISPE method followed by high performance liquid chromatography with diode array detection was established for the determination of NFX in seawater. The recoveries of spiked seawater samples using the MISPE columns were satisfactorily higher than 77.6%. The relative standard deviation was less than 5.60%, and the limit of detection was 0.027?μg L?1. Four seawater samples obtained from the Bohai Sea were analyzed, and NFX was found only at one location at a concentration of 0.280?μg L?1.  相似文献   

13.
Gholivand MB  Khodadadian M 《Talanta》2011,85(3):1680-1688
Molecularly imprinted polymers (MIPs) with high selectivity toward methocarbamol have been computationally designed and synthesized based on the general non-covalent molecular imprinting approach. A virtual library consisting of 18 functional monomers was built and possible interactions between the template and functional monomers were investigated using a semiempirical approach. The monomers with the highest binding scores were then considered for additional calculations using a more accurate quantum mechanical (QM) calculation exploiting the density functional theory (DFT) at B3LYP/6-31G(d,p) level. The cosmo polarizable continuum model (CPCM) was also used to simulate the polymerization solvent. On the basis of computational results, acrylic acid (AA) and tetrahydrofuran (THF) were found to be the best choices of functional monomer and polymerization solvent, respectively. MIPs were then synthesized by the precipitation polymerization method and used as selective adsorbents to develop a molecularly imprinted solid-phase extraction (MISPE) procedure before quantitative analysis. After MISPE the drug could be determined either by differential pulse voltammetry (DPV), on a glassy carbon electrode modified with multiwalled-carbon nanotubes (GC/MWNT), or high performance chromatography (HPLC) with UV detection. A comparative study between MISPE-DPV and MISPE-HPLC-UV was performed. The MISPE-DPV was more sensitive but both techniques showed similar accuracy and precision.  相似文献   

14.
The aim of this work was to evaluate the use of a molecularly imprinted polymer as a selective solid‐phase extraction sorbent for the clean‐up and pre‐concentration of patulin from apple‐based food products. Ultra high pressure liquid chromatography coupled to ultraviolet absorbance detection was used for the analysis of patulin. The molecularly imprinted polymer was applied, for the first time, to the determination of patulin in apple juice, puree and jam samples spiked within the maximum levels specified by the European Commission No. 1881/2006. High recoveries (>77%) were obtained. The method was validated and found to be linear in the range 2–100 μg/kg with correlation coefficients greater than 0.965 and repeatability relative standard deviation below 11% in all cases. Compared with dispersive solid‐phase extraction (QuEChERS method) and octadecyl sorbent, the molecularly imprinted polymer showed higher recoveries and selectivity for patulin. The application of Affinisep molecularly imprinted polymer as a selective sorbent material for detection of patulin fulfilled the method performance criteria required by the Commission Regulation No. 401/2006, demonstrating the suitability of the technique for the control of patulin at low ppb levels in different apple‐based foods such as juice, puree and jam samples.  相似文献   

15.
In this work, a molecularly imprinted polymer (MIP) of morphine (MO) was prepared through thermal radical copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of MO templates, and a molecularly imprinted sorbent assay (MIA) based on a colorimetric reporter was developed to determine the adsorption isotherm of MO-MIP binding. In practice, the MO-bound MIP was brought into contact with an aqueous mixture of Fe3+ and [Fe(CN)6]3− so that the 3-phenolic group of MO was oxidized and Fe3+ was reduced to Fe2+. As a result, the MO-bound MIP was stained with Prussian blue (PB), which was attributed to the instant co-precipitation of Fe2+ and [Fe(CN)6]3− (Ksp=10−40). Accordingly, MO-MIP binding of the blue dye could be detected by visible spectroscopy. In addition, such staining could successfully distinguish MO from codeine. Upon data analyses, a two-site binding isotherm with two dissociation constants of 6.00×10−5 and 1.03×10−3 M was found for MO-MIP binding. MIAs for non-MIP were also performed. In addition, the results of flow-system characterizations and the particle size effect are also described in this paper.  相似文献   

16.
17.
A method for determination of low concentrations of chloramphenicol in urine, feed water, milk and honey was developed. A comparison was carried out between a routinely used analytical method based on solid phase extraction (SPE-C18) for cleaning the extract and the new procedure for the sample preparation using columns based on the molecular imprinted polymers (MIP) principle. The extracts obtained from the MIP clean-up procedure were clean enough for chromatografic analyses. Confirmatory analyses were conducted using GC/MS-NCI after derivatisation (silylation). The described method was fully validated according to CD 2002/657/EC. This method is considerably robust and allows very dirty samples to be processed. The described MIP procedure is very simple and low-time-consuming, and provides high throughput of the samples examined. This could be used for routine screening and confirmatory analyses as well.  相似文献   

18.
Highly selective molecularly imprinted polymers (MIPs) for solid-phase extraction and determination of furosemide in human plasma have been designed and prepared. In order to study the intermolecular interactions in the pre-polymerization mixture and to find a suitable functional monomer in MIP preparation, a computational approach was developed. It was based on the comparison of the binding energy of the complexes between the template and functional monomers. Having confirmed the results of computational method, three MIPs were synthesized with different functional monomers, i.e. acrylamide (AAM), 4-vinylpiridine (4-VP) and acrylonitrile (ACN), and then evaluated using Langmuir-Freundlich (LF) isotherm. Using the MIP prepared by AAM as functional monomer, a molecularly imprinted solid-phase extraction procedure followed by high performance liquid chromatography with ultraviolet detector (MISPE-HPLC-UV) was developed for selective extraction and determination of furosemide in human plasma. For the proposed MISPE-HPLC-UV method, the linearity between responses (peak area) and concentration was found over the range of 75-3500 ng mL−1 with a linear regression coefficient (R2) of 0.997. The limit of detection (LOD) and quantification (LOQ) in plasma were 12.9 and 43.3 ng mL−1, respectively.  相似文献   

19.
Zhou J  Ma C  Zhou S  Ma P  Chen F  Qi Y  Chen H 《Journal of chromatography. A》2010,1217(48):7478-7483
A simple, rapid and sensitive method for the determination of pirimicarb in tomato and pear using polymer monolith microextraction (PMME) based on the molecularly imprinted polymer (MIP) monolith combined with high-performance liquid chromatography-photodiodes array detector (HPLC-PAD) was developed. By optimizing the polymerization conditions, such as the nature of porogenic solvent and functional monomer, the molar ratio of the monomer and cross-linker, an pirimicarb MIP monolith was synthesized in a micropipette tip using methacrylic acid (MAA) as the functional monomer, ethylene dimethacrylate (EGDMA) as the cross-linker and the mixture of toluene-dodecanol as the porogenic solvent. The MIP monolith showed highly specific recognition for the template pirimicarb. The monolith was applied for the selective extraction of pirimicarb in tomato and pear. Several parameters affecting MIP-PMME were investigated, including the nature and volume of extraction solvent, sample volume, flow rate and sample pH. Under the optimum PMME and HPLC conditions, the linear ranges were 2.0-1400 μg/kg for pirimicarb in tomato and pear with the correlation coefficient of above 0.999. The detection limits (s/n=3) were both 0.6 μg/kg. The proposed method was successfully applied for the selective extraction and determination of pirimicarb in tomato and pear.  相似文献   

20.
Fast, reliable and inexpensive analytical techniques for trace detection of explosive components are in high demand. Our approach is to develop specific sensor coating materials based on molecularly imprinted polymers (MIPs). Despite the known inhibition of radical polymerisations by nitro groups and the known shrinkage of the polymer lattice during/after drying we were able to synthesize particulate MIPs by suspension polymerisation as well as thin MIP coatings by direct surface polymerisation on quartz crystal microbalances (QCM). The best method to purify the porous beads was Soxhlet extraction followed by supercritical carbon dioxide extraction (SFE with sc-CO2) at mild conditions (150 bar, 50 °C). At least a removal of >99.7% of the template was achieved. Performance tests of TNT imprinted polymer beads showed that acrylamide (AA) and more pronounced also methacrylic acid (MAA) possessed an enhanced adsorption tendency for gaseous TNT. An adsorption of 2,4-DNT, dinitrotoluene, by these MIPs was not detected. Using 2,4-DNT as template and methacrylamide, MAAM, a positive imprint effect for gaseous 2,4-DNT was achieved with no measurable cross-sensitivity for 2,4,6-TNT.The thin MIP coatings directly synthesized on the QCMs showed thicknesses of 20 to up to 500 nm. Preliminary screening experiments were performed for five different monomers and three different solvents (acetonitrile, chloroform and dimethylformamide). Best adsorption properties for TNT vapour until now showed a PAA-MIP synthesized with chloroform. Direct measurements of the mass attachment, respectively frequency decrease of the coated QCMs during vapour treatment showed a TNT-uptake of about 150 pg per μg MIP per hour. Results look worthy for further studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号