首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Over the past few years, single-walled carbon nanotubes (SWNTs) have been the focus of intense research motivated by their unique physical and chemical properties. This review specifically summarizes recent progress in the development of fluorescence biosensors that integrate the quenching property of SWNTs and the recognition property of functional nucleic acids. SWNTs are substantially different from organic quenchers, showing superior quenching efficiency for a variety of fluorophores, with low background and high signal-to-noise ratio, as well as other advantages derived from the nanomaterial itself. As the second key component of biosensors, functional nucleic acids can bind to either their complementary DNA or a target molecule with the ability to recognize a broad range of targets from metal ions to organic molecules, proteins, and even live cells. By taking advantage of the strengths and properties of both SWNTs and nucleic acid based aptamers, a series of fluorescence biosensors have been designed and fabricated for the detection of a broad range of analytes with high selectivity and sensitivity.  相似文献   

3.
A multi-walled carbon nanotube paste electrode (MWCPE) is prepared as an electrochemical sensor with high sensitivity and selectivity in responding to isoniazid. The electrochemical oxidation of isoniazid is investigated in buffered solution by cyclic and differential pulse voltammetry. The electrode is shown to be very effective for the detection of isoniazid in the presence of other biological reductant compounds. The electrochemical oxidation of cysteine, due to the high overvoltage, is completely stopped at the surface of MWCPE. The electrode exhibits a very good resolution between the voltammetric peak of isoniazid and the peaks of ascorbic acid (AA) and dopamine (DA). A resolution of more than 450 mV between the anodic peak potentials makes the MWCPE suitable for simultaneous detection of isoniazid in the presence of AA or DA in clinical and pharmaceutical preparations. Differential pulse voltammetry (DPV) is applied as a sensitive method for the determination of isoniazid. The linear range in these determinations is 1 × 10−6–1 × 10−3 M for isoniazid and the detection limit is 5 × 10−7 M. The electrode was applied to the simultaneous determinations in isoniazid and AA mixtures and also, isoniazid and DA mixture over a wide concentration range. The slope variation for the calibration curves of isoniazid (RSD) was less than 4.5% (based on ten measurements over a period of three months).  相似文献   

4.
We demonstrate noncovalent electrostatic and π-π interactions to assemble semiconducting single wall carbon nanotube (SWCNT)-C(60)@COP nanohybrids. The C(60)@COP light harvesting complexes bind strongly to SWCNTs due to significant π-π-stacking between C(60), the aromatic dicarbazolylacetylene moieties and the nanotube surfaces.  相似文献   

5.
We report the real-time detection of protein using SWNT-FET-based biosensors comprising DNA aptamers as molecular recognition elements. Anti-thrombin aptamers that are highly specific to serine protein thrombin were immobilized on the sidewall of a SWNT-FET using CDI-Tween linking molecules. The binding of thrombin aptamers to SWNT-FETs causes a rightward shift of the threshold gate voltages, presumably due to the negatively charged backbone of the DNA aptamers. While the addition of thrombin solution causes an abrupt decrease in the conductance of the thrombin aptamer immobilized SWNT-FET, no noticeable change was observed with elastase.  相似文献   

6.
The preparation and characterisation of a new composite electrode with Co3O4 particles-modified multi-walled carbon nanotube (MWCNT) and poly(phenosafranine), as well as its novel application for the voltammetric detection of rutin was described. The resulting composite electrode was characterised using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). In the optimised experimental conditions, the oxidation peak current (Ipa) of rutin showed a linear increase in concentration, between 0.008–0.6 and 0.80–6.0 μmol L−1, with a detection limit of 0.00379 μmol L−1. Due to its good selectivity and stability, the composite electrode was successfully applied in detecting rutin in pharmaceutical formulations.  相似文献   

7.
Electrodeposition of Pt-Pb nanoparticles (PtPbNPs) to multi-walled carbon nanotubes (MWCNTs) resulted in a stable PtPbNP/MWCNT nanocomposite with high electrocatalytic activity to glucose oxidation in either neutral or alkaline medium. More importantly, the nanocomposite electrode with a slight modification exhibited high sensitivity, high selectivity, and low detection limit in amperometric glucose sensing at physiological neutral pH (poised at a negative potential). At +0.30 V in neutral solution, the nanocomposite electrode exhibited linearity up to 11 mM of glucose with a sensitivity of 17.8 μA cm−2 mM−1 and a detection limit of 1.8 μM (S/N = 3). Electroactive ascorbic acid (0.1 mM), uric acid (0.1 mM) and fructose (0.3 mM) invoked only 23%, 14% and 9%, respectively, of the current response obtained for 3 mM glucose. At −0.15 V in neutral solution, the electrode responded linearly to glucose up to 5 mM with a detection limit of 0.16 mM (S/N = 3) and detection sensitivity of ∼18 μA cm−2 mM−1. At this negative potential, ascorbic acid, uric acid, and fructose were not electroactive, therefore, not interfering with glucose sensing. Modification of the nanocomposite electrode with Nafion coating followed by electrodeposition of a second layer of PtPbNPs on the Nafion coated PtPbNP/MWCNT nanocomposite produced a glucose sensor (poised at −0.15 V) with a lower detection limit (7.0 μM at S/N = 3) and comparable sensitivity, selectivity and linearity compared to the PtPbNP/MWCNT nanocomposite. The Nafion coating lowered the detection limit by reducing the background noise, while the second layer of PtPbNPs restored the sensitivity to the level before Nafion coating.  相似文献   

8.
Electrochemical detection of Hg(II) using a electropolymerized ion imprinting poly(2-mercaptobenzothiazole) films at the surface of gold nanoparticles/single-walled carbon nanotube nanohybrids modified glassy carbon electrode (PMBT/AuNPs/SWCNTs/GCE) is described for the first time. The Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE sensor exhibits larger binding to functionalized capacity, larger affinity, faster binding kinetics and higher selectivity to template Hg(II). The differential pulse anodic stripping voltammetry (DPASV) response of the Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE sensor to Hg(II) is ca. 3.7- and 10.5-fold higher than that at the non-imprinted PMBT/AuNPs/SWCNTs/GCE and the imprinted PMBT/AuNPs/GCE, respectively, and the detection limit for Hg(II) is 0.08 nM (S/N = 3, which is well below the guideline value given by the World Health Organization) and a sensitivity of 0.749 μA nM−1 was obtained. Excellent wide linear range (0.4–96.0 nM) and good repeatability (relative standard deviation of 2.6%) were obtained for Hg(II). The interference experiments show that Ag(I), Pb(II), Cd(II), Zn(II) and Cu(II) had little or no influence on the Hg(II) signal. These values, particularly the high sensitivity and excellent selectivity in contrast to the values reported previously in the area of electrochemical Hg(II) detection, demonstrate the analytical performance of the Hg(II)-imprinted PMBT/AuNPs/SWCNTs/GCE toward Hg(II) is superior to the existing electrodes and could be used for efficient determination of Hg(II) in natural water samples.  相似文献   

9.
4,7-Disubstituted benzothiadiazoles containing 1-arylethynyl and 4-methoxyphenyl groups are selective photoluminescent "light up" probes to duplex DNA with unprecedented sensibility in both spectrophotometric and spectrofluorimetric measurements.  相似文献   

10.
A polymeric membrane ion-selective electrode for determination of heparin is described in this paper.Protamine is incorporated into the organic membrane phase and functions as sensing element for selective recognition of heparin.The proposed membrane electrode exhibits high selectivity for heparin over lipophilic anions such as thiocyanide and salicylate.The potentiometric response to the concentration of heparin is Unear in the range of 0.01-0.4 U/mL and a lower detection limit of 0.005 U/mL can be achieved.  相似文献   

11.
A novel amperometric immunosensor for the determination of alpha-fetoprotein (AFP) was constructed using films of multi-wall carbon nanotubes/DNA/thionine/gold nanoparticles (nano-Au). Firstly, multi-wall carbon nanotubes (MWCNT) dispersed in poly(diallydimethlammonium chloride) (PDDA) were immobilized on the nano-Au film which was electrochemically deposited on the surface of glassy carbon electrode. Then a negatively charged DNA film was absorbed on the positively charged PDDA. Subsequently, thionine was attached to the electrode via the electrostatic interaction between thionine and the DNA. Finally, the nano-Au was retained on the thionine film for immobilization of AFP antibody (anti-AFP). The modification process was characterized by cyclic voltammetry (CV) and scanning electron microscope (SEM). The factors possibly influenced the performance of the proposed immunosensors were studied in detail. Under optimal conditions, the proposed immunosensor exhibited good electrochemical behavior to AFP in a two concentration ranges: 0.01–10.0 and 10.0–200.0 ng/mL with a relatively low detection limit of 0.04 ng/mL at three times the background noise. Moreover, the selectivity, repeatability and stability of the proposed immunosensor were acceptable.  相似文献   

12.
A nickel nanoparticle (NiNP)/carbon nanotube (CNT)-modified carbon fiber microelectrode (NiNPs/CNTs/CFME) was fabricated using a two-step electroless plating/chemical vapor deposition method. The morphology of the NiNPs/CNTs composite structure was characterized by scanning electron microscopy, and its elemental composition was characterized by an energy dispersive spectrometer. The electrochemical behavior of the NiNPs/CNTs/CFME in aqueous alkaline solutions of insulin was investigated by cyclic voltammetry (CV), chronoamperometry, and electrochemical impedance spectroscopy in sequence. CV curves show that the NiNPs/CNTs/CFME displays a high oxidation peak current, a fast electron transfer rate, and good electrocatalytic activity towards insulin, compared to a bare CFME and a pure NiNP-modified CFME. In the chronoamperometry tests, the NiNPs/CNTs/CFME demonstrates an excellent analytical performance in detecting low concentrations of insulin, including good sensitivity (1.11 nA μM?1) and a low detection limit (270 nM). Moreover, this microelectrode exhibits great reproducibility in successive potential cycling and satisfactory long-term stability after storage at room temperature for approximately 8 weeks.  相似文献   

13.
Guo Z  Ren J  Wang J  Wang E 《Talanta》2011,85(5):2517-2521
Ochratoxin A, a toxin produced by Aspergillus ochraceus and Penicillium verrucosum, is one of the most abundant food-contaminating mycotoxins in the world. It has been classified by the International Agency for Research on Cancer (IARC) as a possible human carcinogen. In this paper, a sensitive and selective fluorescent aptasensor for ochratoxin A (OTA) detection was constructed, utilizing single-walled carbon nanotubes (SWNTs) as quencher which can quench the fluorescence of free unfolded toxin-specific aptamer attached with FAM (carboxyfluorescein). Without any coating materials as compared to graphene-oxide based sensor, we obtained the detection limit of our sensing platform based on SWNTs to be 24.1 nM with a linear detection range from 25 nM to 200 nM. This technique responded specifically to OTA without interference from other analogues (N-acetyl-l-phenylalanine, warfarin and OTB). It has also been verified for real sample application by testing 1% beer containing buffer solution spiked with a series of concentration of OTA.  相似文献   

14.
Wei Zhao  Xia Qin  Zixia Zhao  Lili Chen  Yuxin Fang 《Talanta》2009,80(2):1029-943
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed based on multi-wall carbon nanotube/silver nanoparticle nanohybrids (MWCNT/Ag nanohybrids) modified gold electrode. The process to synthesize MWCNT/Ag nanohybrids was facile and efficient. In the presence of carboxyl groups functionalized multi-wall carbon nanotubes (MWCNTs), silver nanoparticles (Ag NPs) were in situ generated from AgNO3 aqueous solution and readily attached to the MWCNTs convex surfaces at room temperature, without any additional reducing reagent or irradiation treatment. The formation of MWCNT/Ag nanohybrids product was observed by transmission electron microscope (TEM), and the electrochemical properties of MWCNT/Ag nanohybrids modified gold electrode were characterized by electrochemical measurements. The results showed that this sensor had a favorable catalytic ability for the reduction of H2O2. The resulted sensor could detect H2O2 in a linear range of 0.05-17 mM with a detection limit of 5 × 10−7 M at a signal-to-noise ratio of 3. The sensitivity was calculated as 1.42 μA/mM at a potential of −0.2 V. Additionally, it exhibited good reproducibility, long-term stability and negligible interference of ascorbic acid (AA), uric acid (UA), and acetaminophen (AP).  相似文献   

15.
An electrochemical sensing platform was developed for the amperometric detection of β-nicotinamide adenine dinucleotide (NADH) through the integration of a multi-walled carbon nanotube (MWCNT) into electropolymerized phenothiazine dyes. The composite containing MWCNT and poly(phenothiazine) was prepared by electro-oxidative polymerization of phenothiazine derivatives, Azure B, Azure A and thionine, into an MWCNT/ poly(diallyldimethylammonium chloride) (PDDA) multilayer, which was constructed by electrostatic layer-by-layer assembly on a glassy carbon electrode. The three phenothiazine monomers used in this study exhibited similar electrochemical behaviors. Azure B was used extensively as a model monomer for the investigation. Electrochemical techniques and scanning electron microscopy were used to demonstrate that the porous composite was formed and that the carbon nanotube served as a nano-sized backbone for the loading of polymeric phenothiazine. The electrocatalytic current for NADH oxidation was enhanced as the number of layers increased, implying that the increase of NADH-accessible poly(phenothiazine) and the three-dimensional arrangement of the poly(phenothiazine)-coated MWCNT in the composite facilitated electron and NADH transfer. Under optimal conditions, the detection limit for NADH decreases to 7.0 × 10?8?M at a potential of 0.1 V (versus Ag/AgCl) using a {MWCNT/PDDA}8?poly(Azure B) composite modified glassy carbon electrode, with a response time of about 5 s. This work demonstrates that the electropolymerization of the phenothiazine monomer into a pre-formed multilayer containing MWCNT can be used for the controllable preparation of stable MWCNT/poly(phenothiazine) composites on electrode surfaces, which have the potential to provide a platform for electrochemical biosensors based on NAD+-dependent dehydrogenase enzymes.  相似文献   

16.
Oriented SWNTs in polymer composites have shown dramatic improvements in the physical properties of a composite because of the anisotropic shape and properties of SWNTs. Controlled alignment of SWNTs during composite fabrication implies better material function performance. This letter reports a new fabrication technique whereby aligned SWNTs and robust SWNT-polymer composites can be made using a fusion method of SWNT combing and layer-by-layer (LBL) assembly. As we previously reported, LBL assembly demonstrated exceptional processing ability in constructing the uniform distribution of a SWNT-polymer composite. Combined with this uniformity, this SWNT combing technique endows controlled alignment of single-stranded SWNTs in a SWNT-polymer composite system. SWNT combing employs air-water interfacial forces to change the molecular topography from the random adsorption state to the stretched alignment of SWNTs. More specifically, air-water interfacial forces are associated with an excess viscous drag force and an intrinsic dewetting rate along SWNTs. Moreover, the alignment efficiency of SWNTs is high enough to construct a multilayered LBL film with horizontal-linear weaving structures. This simple method also can be applied for aligning other nanowire materials because it utilizes simple geometric features of SWNTs.  相似文献   

17.
We report on a carbon nanotube (CNT) fiber microelectrode coated with palladium nanoparticles (PdNPs) and enabling electrochemical sensing of hydrogen peroxide (H2O2). The synergistic effects of the CNT fibers (good mechanical strength and large surface area) and of the PdNPs (high electrocatalytic activity) result in a microelectrode for H2O2 that exhibits a 2-s response time, a detection limit as low as 2 μM, a sensitivity of 2.75 A cm?2 M?1, and a linear response range from 2 μM to 1.3 mM (R?=?0.9994). The sensor is also selective and not interfered by potentially competing species in biological fluids, thus representing an inexpensive but highly sensitive and selective microsensor for H2O2.
Figure
Images ofthe palladium nanoparticle-coated carbon nanotube (PdNP/CNT) fiber microelectrode (left) and its amperometric response to hydrogen peroxide (H2O2) with different concentrations (right)  相似文献   

18.
Rapid detection and enumeration of pathogens is essential for monitoring contamination and spoilage of food products to ensure improved quality control management. Functionalized polymeric magnetic nanoconstructs (FPMNCs) were developed as an effective immunomagnetic separator and sensing platform for the selective capturing of Salmonella typhimurium. Novel FPMNCs were prepared in three stages involving synthesis of iron oxide (IO) dispersion, capping with sodium oleate and encapsulation of preformed IO nanoparticles by in-situ free radical emulsion polymerization of styrene (St), methyl methacrylate (MMA) and acetoacetoxy ethylmethacrylate (AAEM). PMMA improves the stability of FPMNCs by bridging extremely hydrophobic PS and hydrophilic PAAEM. Core-shell morphology of hydrophobic core of IO, PS & PMMA and hydrophilic shell of PAAEM was demonstrated by SEM, TEM and FTIR studies. FPMNCs with surface functionalized acetoacetoxy groups were covalently attached with polyclonal antibodies against Salmonella common structural antigen (CSA-1-Ab) without using any linker and catalyst. Colorimetric readout signal was acquired using CSA-1-Ab-HRP as secondary antibody after formation of sandwich immunocomplex with bacteria where the optical density of the samples were recorded using ELISA plate reader at 450 nm. The developed immunoassay was specific and selective which captures only targeted S. typhimurium with a detection limit of 10 cells/mL lower than infectious dose of salmonellosis infection. Minimal interference of food matrix with high signal to noise ratio was shown by various food samples. In addition, the performance of developed FPMNC based immunoassay was superior to commercially available immunomagnetic microbeads demonstrating undisputed advantage for capturing and detecting specific bacteria without any pre-enrichment of sample.  相似文献   

19.
A new fluorescent sensor capable of sensing Cr3+ has been synthesized. Complexing with Cr3+ triggers the formation of a highly fluorescent ring-open form which is pink in color. The sensor shows extremely high fluorescence enhancement upon complexation with Cr3+ and it can be used as a ‘naked eye’ sensor. Binding of Cr3+ was found to be reversible as the pink color disappears with excess EDTA.  相似文献   

20.
We report on a simple method for the determination of iodide in aqueous solution by exploiting the fluorescence enhancement that is observed if the complex formed between carbon dots and mercury ion is exposed to iodide. Fluorescent carbon dots (C-dots) were treated with Hg(II) ion which causes quenching of the emission of the C-dots. On addition of iodide, the Hg(II) ions are removed from the complex due to the strong interaction between Hg(II) and iodide. This causes the fluorescence to be restored and enables iodide to be determined in the 0.5 to 20 μM concentration range and with a detection limit of ~430 nM. The test is highly selective for iodide (over common other anions) and was used for the determination of iodide in urine.
Figure
A“turn-on” fluorescent probe based on carbon dots was obtained and using it to determine the concentration of iodide according to the fluorescent enhancement in aqueous solution  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号