首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到3条相似文献,搜索用时 2 毫秒
1.
A number of ultrasound imaging systems employs harmonic imaging to optimize the trade off between resolution and penetration depth and center frequencies as high as 15 MHz are now used in clinical practice. However, currently available measurement tools are not fully adequate to characterize the acoustic output of such nonlinear systems primarily due to the limited knowledge of the frequency responses beyond 20 MHz of the available piezoelectric hydrophone probes. In addition, ultrasound hydrophone probes need to be calibrated to eight times the center frequency of the imaging transducer. Time delay spectrometry (TDS) is capable of providing transduction factor of the probes beyond 20 MHz, however its use is in practice limited to 40 MHz. This paper describes a novel approach termed time gating frequency analysis (TGFA) that provides the transduction factor of the hydrophone probes in the frequency domain and significantly extends the quasi-continuous calibration of the probes up to 60 MHz. The verification of the TGFA data was performed using TDS calibration technique (up to 40 MHz) and a nonlinear calibration method (up to 100 MHz). The nonlinear technique was based on a novel wave propagation model capable of predicting the true pressure-time waveforms at virtually any point in the field. The spatial averaging effects introduced by the finite aperture hydrophones were also accounted for. TGFA calibration results were obtained for different PVDF probes, including needle and membrane designs with nominal diameters from 50 to 500 micro m. The results were compared with discrete calibration data obtained from an independent national laboratory and the overall uncertainty was determined to be +/-1.5 dB in the frequency range 40-60 MHz and less than +/-1 dB below 40 MHz.  相似文献   

2.
The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency characterization of ultrasound fields. Also, it was of interest to investigate the feasibility of using FO probes in high intensity fields such as those employed in HIFU (high intensity focused ultrasound) applications. In addition to the development and validation of a novel, 100 MHz calibration technique the innovative elements of this research include implementation and testing of a prototype FO sensor with an active diameter of about 10 μm that exhibits uniform sensitivity over the considered frequency range and does not require any spatial averaging corrections up to about 75 MHz. The results of the calibration measurements are presented and it is shown that the optimized calibration technique allows the sensitivity of the hydrophone probes to be determined as a virtually continuous function of frequency and is also well suited to verify the uniformity of the FO sensor frequency response. As anticipated, the overall uncertainty of the calibration was dependent on frequency and determined to be about ±12% (±1 dB) up to 40 MHz, ±20% (±1.5 dB) from 40 to 60 MHz and ±25% (±2 dB) from 60 to 100 MHz. The outcome of this research indicates that once fully developed and calibrated, the combined acousto-optic system will constitute a universal reference tool in the wide, 100 MHz bandwidth.  相似文献   

3.
To facilitate the implementation and verification of the new ultrasound hydrophone calibration techniques described in the companion paper (somewhere in this issue) a nonlinear propagation model was developed. A brief outline of the theoretical considerations is presented and the model's advantages and disadvantages are discussed. The results of simulations yielding spatial and temporal acoustic pressure amplitude are also presented and compared with those obtained using KZK and Field II models. Excellent agreement between all models is evidenced. The applicability of the model in discrete wideband calibration of hydrophones is documented in the companion paper somewhere in this volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号