首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Generally, bioanalytical chromatographic methods are validated according to a predefined programme and distinguish a pre-validation phase, a main validation phase and a follow-up validation phase. In this paper, a rational, total performance evaluation programme for chromatographic methods is presented. The design was developed in particular for the pre-validation and main validation phases. The entire experimental design can be performed within six analytical runs. The first run (pre-validation phase) is used to assess the validity of the expected concentration-response relationship (lack of fit, goodness of fit), to assess the specificity of the method and to assess the stability of processed samples in the autosampler for 30 h (benchtop stability). The latter experiment is performed to justify overnight analyses. Following approval of the method after the pre-validation phase, the next five runs (main validation phase) are performed to evaluate method precision and accuracy, recovery, freezing and thawing stability and over-curve control /dilution. The design is nested, i.e., many experimental results are used for the evaluation of several performance characteristics. Analysis of variance (ANOVA) is used for the evaluation of lack of fit and goodness of fit, precision and accuracy, freezing and thawing stability and over-curve control/ dilution. Regression analysis is used to evaluate benchtop stability. For over-curve control/ dilution, additional to ANOVA, also a paired comparison is applied. As a consequence, the recommended design combines the performance of as few independent validation experiments as possible with modern statistical methods, resulting in optimum use of information. A demonstration of the entire validation programme is given for an HPLC method for the determination of total captopril in human plasma.  相似文献   

2.
New methods for the determination of the nominal content of miokamycin in three commercial pharmaceutical preparations available in many different forms are proposed. Solid samples, grinding of which is the sole pretreatment required, are analysed by near infrared (NIR) spectroscopy, using a fibre-optic probe. The active principle is quantified by partial least-squares regression (PLSR). The three proposed methods were validated with a view to their use as control methods; the selectivity of the method, and the repeatability, intermediate precision, accuracy, linearity and robustness of each PLSR calibration model used were determined. The relative standard error of prediction (RSEP) was < 1.5% and the validation results testify to the suitability of the proposed methods.  相似文献   

3.
Abstract

A high performance liquid chromatographic procedure for the analysis of pharmaceutical formulations containing pentaerythritol tetranitrate including the diluted bulk drug and finished products consisting of uncoated tablets and timed-release capsules and tablets was developed. The method employs a reversed-phase system with UV detection at 230 nm. Replicate analyses of 11 commercial formulations (5 diluted bulk drugs and 6 dosage forms gave precision values (CV) having a range of 0.17 to 1.80%. Recovery values obtained from these commercial preparations via fortification ranged from 98.8 to 102.0% while recoveries from 3 synthetic mixtures varied from 99.2 to 100.8%. The detector response for the analyte was observed to be linear over a 50-fold concentration range using nitroglycerin as the internal standard. The proposed HPLC method is specific, easy to perform and exhibits excellent accuracy and precision. Seven different brands of HPLC columns were evaluated for possible use with the method.  相似文献   

4.
A critical discussion about the possibility of improving the method validation process by means of experimental design is presented. The reported multivariate strategies concern the evaluation of the performance parameters robustness and intermediate precision, and the optimisation of bias and repeatability. In particular, accuracy and precision improvement constitutes a special subset of experimental design in which the bias and the relative standard deviation of the assay are optimised. D-optimal design was used in order to plan experiments for this aim. The analytical methods considered were capillary electrophoresis, HPLC, adsorptive stripping voltammetry and differential pulse polarography. All methods were applied to real pharmaceutical analysis problems.  相似文献   

5.
6.
Gumustas  Mehmet  Kurbanoglu  Sevinc  Uslu  Bengi  Ozkan  Sibel A. 《Chromatographia》2013,76(21):1365-1427

Liquid chromatography (LC) is a separation technique used in many different areas to aid the identification and quantification of substances in various matrices. LC techniques with various detection modes have been widely used for the sensitive and selective determination of trace amounts of pharmaceutical active compounds in biological samples and their dosage forms. A completely new system design with advanced technology has been developed, called ultra high performance liquid chromatography, which has evolved from high performance liquid chromatography. The application of LC methods to drug analysis introduces a powerful tool for therapeutic drug monitoring as well as for clinical research. The advantages of short turnaround time, method reliability, method sensitivity, and drug specificity justify the use of LC techniques for various groups of the drug active compounds. This review describes some of the principles of ultra high performance liquid chromatography and high performance liquid chromatography, validation of these methods, system suitability tests for the methods, and application of methods to pharmaceutical analysis in the last 3 years.

  相似文献   

7.
This paper describes the development, optimization, and validation of a method for the determination of five pharmaceuticals from different therapeutic classes (antibiotics, anthelmintics, glucocorticoides) in water samples. Water samples were prepared using SPE and extracts were analyzed by HPLC with diode‐array detection. The efficiency of 11 different SPE cartridges to extract the investigated compounds from water was tested in preliminary experiments. Then, the pH of the water sample, elution solvent, and sorbent mass were optimized. Except for optimization of the SPE procedure, selection of the optimal HPLC column with different stationary phases from different manufacturers has been performed. The developed method was validated using spring water samples spiked with appropriate concentrations of pharmaceuticals. Good linearity was obtained in the range of 2.4–200 μg/L, depending on the pharmaceutical with the correlation coefficients >0.9930 in all cases, except for ciprofloxacin (0.9866). Also, the method has revealed that low LODs (0.7–3.9 μg/L), good precision (intra‐ and interday) with RSD below 17% and recoveries above 98% for all pharmaceuticals. The method has been successfully applied to the analysis of production wastewater samples from the pharmaceutical industry.  相似文献   

8.
A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was <3% for all 6 concentration levels. The correlation coefficient for the linearity within the concentration range was determined to be > 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.  相似文献   

9.
Capillary electrophoresis sodium dodecyl sulfate (CE-SDS) is an analytical method to assess the purity of proteins, commonly applied to monoclonal antibodies (mAbs) in the biopharmaceutical industry. To address the need to standardize the CE-SDS method in the pharmaceutical industry and to enhance the confidence in method transfer between laboratories operating different commercial capillary electrophoresis (CE) instrument platforms, an interlaboratory CE-SDS method validation was organized involving 13 laboratories in 13 companies on four different types of commercial capillary electrophoresis instruments. In the validation, a commercial mAb therapeutic was used as the sample. The validation process followed the analytical guidelines set by the ICH guidelines (International Conference for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use). The method's precision, accuracy, linearity and range, and limit of quantitation (LOQ) were validated in the study. Variations of all the parameters validated in the study passed the pre-set criteria defined at the beginning of the study. The definition was based on previously published works and the intended application purpose of the CE-SDS method for mAbs. The study proved that the CE-SDS method fits its intended application purpose as a size impurity assay and size heterogeneity characterization assay for mAb therapeutic products. This study is the first time a CE-SDS method is validated by multiple laboratories using different commercial CE instrument platforms and on a commercial mAb therapeutic. Its results will enhance the confidence of the biopharmaceutical industry to develop CE-SDS methods and transfer CE-SDS methods between different laboratories.  相似文献   

10.
药物分析中薄层色谱的方法认证   总被引:2,自引:0,他引:2  
林乐明  张军 《色谱》1997,15(4):310-313
在药物分析中,针对所要求的性能参数,对一个薄层色谱程序的各个环节必须进行的认证方法和认可标准进行了讨论。建议当提出结果报告时,应附上关于对方法的认证参数和认证方法的说明。  相似文献   

11.
Method validation is an important and costly step in the development of liquid chromatographic methods, especially for pharmaceutical samples. A ruggedness test is valuable for finding the analytical conditions which give the best performance. By varying the factors that influence method performance, it is possible to design a more rugged method before a study of reproducibility is started. The choice of the factors to test is important. An expert system is described for the selection of factors in ruggedness tests. The system proved satisfactory for 10 of the 11 cases of pharmaceutical formulations tested.  相似文献   

12.
In recent years, transmission Raman spectroscopy (TRS) has emerged as a potent new tool for rapid, nondestructive quantitation in pharmaceutical manufacturing. In order to expand the applicability of TRS and enhance its use in product quality monitoring during drug production, we aimed, in the present study, to apply partial least-squares (PLS) approaches to build a model consisting of 150 handmade tablets and covering 15 levels through the use of a multifactor orthogonal design of experiment (DOE), which was used to predict concentrations of validation tablets made by hand. The difference between results according to HPLC and TRS were negligible. The model was used to predict the active pharmaceutical ingredient (API) content in four random commercial paracetamol tablets, and corrected with the spectra of the commercial tablets to obtain four corresponding models. The results show that the content relative error in the model’s predictions after correction with commercially available tablets was significantly lower than that before correction. The corrected model was used to make predictions for 20 tablets from the brand Panadol. Compared with the HPLC results, the prediction relative error was basically less than 4.00%, and the relative standard deviation (RSD) of the content was 0.86%.  相似文献   

13.
Abstract

This work involved the development of radially compressed, microbore high performance liquid chromatography (HPLC) columns. The design of the overall system and the column are described, and the problems associated with the design features are reported. Variables examined during the course of this work included the column material, column length, packing method, flow rate, radial compression pressure, and internal column pressure. Efficiencies (expressed as plates/meter) are shown for various combinations of those variables and are compared to those obtained using a commercial, steel microbore column.  相似文献   

14.
《Analytical letters》2012,45(5):804-813
This paper presents a simultaneous spectrophotometric determination of aspirin, paracetamol, caffeine, and chlorphenamine from commercial pharmaceutical products using principal component regression and partial-least squares regression. The concentration of the training set was established employing a partial factorial calibration design at four levels. Several quality parameters and recovery values obtained on authentic samples illustrated excellent performance characteristics concerning the goodness of fit and the accuracy and precision of prediction. Eight pharmaceutical formulations containing at least two of these four mentioned active ingredients and diverse electuaries were successfully analyzed. The obtained results were also validated by high-performance liquid chromatography.  相似文献   

15.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

16.
《Analytical letters》2012,45(2):257-280
Abstract

A procedure for selection of wavelength range and number of factors to be used in partial least square calibration that involves the calculation of prediction residual sum of squares (PRESS) in different conditions is proposed. The best model takes into account the minimum PRESS value that does not show significant differences with respect to the corresponding model with fewer factors. The ability of the proposed method to minimize errors in partial least squares (PLS) prediction is demonstrated by applying it to the resolution of phenytoine (DPH) and phenobarbital (PB) binary mixtures with errors less than 2.8%; the results are compared with those obtained using another wavelength selection procedure. The ensuing method, which was validated by high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).  相似文献   

17.
Clarithromycin is a very important macrolide antibiotic used to treat bacterial infections in human and veterinary medicine. This study reports the development and validation of cost-effective, simple, precise, accurate, and robust high-performance liquid chromatography (HPLC) for the determination of clarithromycin (CLA) in tablets. Reversed-phase chromatography was conducted using a standard column at 55°C with ultraviolet detection at 215 nm. A mobile phase consisting of acetonitrile –2-methyl-2-propanol –potassium phosphate buffer was used at a flow rate of 1.0 mL/min. The proposed method displayed good linearity, precision, accuracy, robustness, and specificity. The present HPLC was compared with capillary electrophoresis and bioassay methods and the results indicated that there was no significant difference between these methods. Moreover, the obtained results demonstrated the validity of the isocratic HPLC, which allows reliable quantitation of CLA in pharmaceutical samples. Thus, it can be used as a substitute alternative methodology for the routine quality control of this medicine, in situations where other methods are less accessible in the laboratory.  相似文献   

18.
In 2009, a refined HPLC method based on AOAC Official Method 2005.06 was developed and validated for the determination of paralytic shellfish poisoning (PSP) in mussels. A single-laboratory validation study of this method was undertaken here for the analysis of PSP toxins in oysters, cockles, clams, and razor clams. The method was characterized for selectivity, sensitivity, linearity, precision, repeatability, recovery, ruggedness, and uncertainty of measurement. Validation data were utilized to determine method performance characteristics for non-mussel bivalves for all commercially available certified reference toxins, extending the method to dcNEO and dcGTX2,3, where available. A period of parallel testing of oysters, cockles, and clams enabled a comparison of sample toxicities obtained using mouse bioassay (MBA) and HPLC methodologies, although only a very low number of PSP-positive samples were obtained through the United Kingdom official control monitoring program. Results from the MBA and HPLC methods were well-correlated for PSP-negative samples, but the low number of naturally contaminated PSP-positive samples has prevented any comparative statistical assessment of method performance for non-mussels between the two official methods. However, some evidence for potentially significant differences in total saxitoxin equivalents obtained by the two methods in some species has highlighted the need for further comparative testing in non-mussel samples to be conducted prior to implementation of the HPLC method in routine official control monitoring programs.  相似文献   

19.
A four-step development, optimization and validation strategy for high-performance liquid chromatography (HPLC) fingerprints of Ginkgo biloba extract is described. A suitable chromatographic system was selected first. The following step was performing a screening design to select important parameters. After selecting some controllable parameters and their range to further optimize, gradient optimization with uniform design was done. At last, method validation including determination of injection precision, repeatability, and a sample stability test, was performed. Through this effective and integrated four-step method, a feasible and reliable HPLC fingerprint to identify and assess the Ginkgo biloba quality can easily be established using a linear gradient elution with acetonitrile/0.1% phosphoric acid (from 14/86 to 30/70, v/v, in 40 min) as mobile phase, a column temperature of 30 degrees C and a detection wavelength of 350 nm. The strategy can also be applied for the development of fingerprints in the quality control of other herbal medicines.  相似文献   

20.
刘伟  何勇  吴斌  蒋轲磊 《分析测试学报》2020,39(10):1239-1246
该文通过采用近红外光谱分析技术对原料药(API)的浓度调节过程进行实时监控,介绍了在良好生产规范条件下过程分析技术(PAT)的实施过程。利用偏最小二乘算法开发出两个校正模型分别用以监控原料药和水分含量,并通过模型校正均方根误差(RMSEC)、交叉检验均方根误差(RMSECV)和预测均方根误差(RMSEP)以及对应的决定系数(R~2)来评估模型的性能。为保证模型性能,按照分析方法验证要求对模型的线性和范围、准确性、精密度(重复性)、专属性以及稳健性指标进行验证。最后通过系统性能测试确认检测系统满足商业化运行的要求。结果显示,采用过程分析技术控制浓度调节过程,可以大幅度缩短浓度调节时间,节约蒸汽能耗和检测费用,减少生产过程中的偏差,提升产品工艺水平和批次间一致性。  相似文献   