1.
The combination of optical coherence tomography and spectroscopy may allow for highly localized, quantitative measurements of tissue spectral properties. We present, for the first time to our knowledge, quantitative measurements of the absorption coefficients of phantoms and of hemoglobin and oxygenated hemoglobin with spectroscopic optical coherence tomography (SOCT). Our results suggest that SOCT will be able to provide localized, quantitative oxygenation measurements.  相似文献   

2.
Xu C  Ye J  Marks DL  Boppart SA 《Optics letters》2004,29(14):1647-1649
Optical coherence tomography (OCT) images of biological tissues often have low contrast. Spectroscopic optical coherence tomography (SOCT) methods have been developed to enhance contrast but remain limited because most tissues are not spectrally active in the frequency bands of laser sources commonly used in OCT. Near-infrared (NIR) dyes with absorption spectra features within the OCT source spectrum can be used for enhancing contrast in this situation. We introduce and demonstrate the use of NIR dyes as contrast agents for SOCT. Contrast-enhanced images are compared with fluorescence microscopy, demonstrating a link between SOCT and fluorescence imaging.  相似文献   

3.
Robles FE  Satterwhite LL  Wax A 《Optics letters》2011,36(23):4665-4667
Nonlinear phase dispersion spectroscopy is introduced as a means to retrieve wideband, high spectral resolution profiles of the wavelength-dependent real part of the refractive index. The method is based on detecting dispersion effects imparted to a light field with low coherence transmitted through a thin sample and detected interferometrically in the spectral domain. The same sampled signal is also processed to yield quantitative phase maps and spectral information regarding the total attenuation coefficient using spectral-domain phase microscopy and spectroscopic optical coherence tomography (SOCT), respectively. Proof-of-concept experiments using fluorescent and nonfluorescent polystyrene beads and another using a red blood cell demonstrate the ability of the method to quantify various absorptive/dispersive features. The increased sensitivity of this method, novel to our knowledge, is compared to intensity-based spectroscopy (e.g., SOCT), and potential applications are discussed.  相似文献   

4.
The application of the technique of synthesis of optical coherence function for detection in scattering media is investigated. By modulating the optical frequency, the technique synthesizes the coherence function into a delta-function-like peak at an arbitrary location, and thus can select interferometrically the information at that location. The location is adjustable by the modulation parameter or additional phase modulation. A multi-section super-structure grating distributed Bragg reflector laser diode (SSG-DBR-LD) of THz-order tunable range is employed to enhance the spatial resolution for suppressing the multiple scattering from locations other than that detected. In a preliminary experimental demonstration, a reflectometry of 550 μm spatial resolution was achieved and was used to detect scattering media.  相似文献   

5.
We investigate confocal enhanced optical coherence tomography as a nondestructive evaluation tool for imaging with improved image contrast and depth resolution through a highly scattering paint layer. The depth responses provided by confocal microscopy, optical coherence tomography, and confocal enhanced optical coherence tomography for imaging through paint are investigated. We demonstrate that a new combination of confocal microscopy and optical coherence tomography provides significantly improved resolution and contrast for coherence gated imaging of substrate structures under the paint.  相似文献   

6.
A novel system for multiplexed optical fiber interferometric sensors is proposed applying the synthesis of optical coherence function with phase generated carriers. The ideal parameters of the laser diode frequency modulation for the phase generated carrier with the synthesis of the optical coherence function are discussed. A basic experimental setup including two interferometric sensors is constructed. The results show that the phase signal from the two sensors can successfully be demultiplexed by scanning the synthesized coherence peak.  相似文献   

7.
正弦相位调制的频域光学相干层析成像   总被引:1,自引:1,他引:1  
提出一种基于正弦相位调制的频域光学相干层析成像,利用正弦相位调制干涉术探测复频域干涉条纹的实部和虚部,重建复频域干涉条纹。对该复频域干涉条纹作逆傅里叶变换后,消除了频域光学相干层析成像中存在的复共轭镜像以及直流背景和自相干噪声。对玻璃片样品进行了层析成像实验。实验结果表明,采用正弦相位调制的频域光学相干层析成像,将可利用的成像深度范围扩大到原来的2倍,实现了全深度探测的频域光学相干层析成像。  相似文献   

8.
Contrast agents are utilized in virtually every imaging modality to enhance diagnostic capabilities. We introduce a novel class of optical contrast agent, namely, encapsulating microspheres, that are based not on fluorescence but on scattering nanoparticles within the shell or core. The agents are suitable for reflection- or scattering-based techniques such as optical coherence tomography, light microscopy, and reflectance confocal microscopy. We characterize the optical properties of gold-, melanin-, and carbon-shelled contrast agents and demonstrate enhancement of optical coherence tomography imaging after intravenous injection of such an agent into a mouse.  相似文献   

9.
The use of spectroscopic optical coherence tomography to assess hemoglobin oxygen saturation of whole blood is investigated. We propose to use the differential attenuation coefficient to determine the degree of saturation. Our data show qualitative agreement between the measured differential attenuation coefficients as a function of saturation and predictions based on the oxygen-saturation-dependent absorption and scattering properties of blood.  相似文献   

10.
Wang Y  Wang R 《Optics letters》2010,35(21):3538-3540
We present an autocorrelation method to quantitatively map transverse particle-flow velocity with a Fourier-domain optical coherence tomography system. This method is derived from the intensity fluctuation of the backscattered light modulated by flowing particles. When passing through the probe beam, moving particles encode a transit time into the backscattered light. The slope of the normalized autocorrelation function of the backscattered light is proportional to the transverse velocity. The proposed method is experimentally verified using an intralipid scattering flow phantom.  相似文献   

11.
Low‐coherence optical microscopy or optical coherence microscopy uses light with short coherence length. The well‐known case is: “white‐light interferometry”, which became recently more known as: “optical coherence tomography”. However, when lenses and microscope objectives are used to create interferometric images, in what is known classically as “interference microscopy” or today as “full‐field optical coherence tomography” the spatial coherence starts to play a critical role. In this article the coherence effects in low‐coherence optical microscopy are reviewed. As this technology is becoming increasingly publicized due to its importance in three‐dimensional imaging, particularly of scattering biological media and optical metrology, the understanding of the fundamental physics behind it is essential. The interplay between longitudinal spatial coherence and temporal coherence and the effects associated with them are discussed in detail particularly when high numerical apertures are used. An important conclusion of this study is that a high‐contrast, high‐resolution system for imaging of multilayered samples is the one that uses narrowband illumination and high‐NA objectives with an index‐matching fluid. Such a system, when combined with frequency‐domain operation, can reveal nearly real‐time three‐dimensional images, and is thus competitive with confocal microscopy.  相似文献   

12.
We demonstrate inhibition of the sidelobes of the axial point spread function in optical coherence tomography by shaping the power spectrum of the light source with a remaining power of 4.54 mW. A broadband amplified spontaneous emission source radiating at 1565 +/- 40 nm is employed in a free-space optical coherence tomography system. The axial point spread functions before and after optical spectral shaping are presented. Results show that spectral shaping of the source can inhibit sidelobes of the point spread function up to 12.9 dB, with an associated small increase of 2.2 dB in noise floor in the far field. The effect of spectral shaping on axial resolution is demonstrated according to three metrics. Image quality improvement is also illustrated with optical coherence tomography images of an onion before and after spectral shaping.  相似文献   

13.
An efficient technique for the separation of and compensation for coherent noise in spectral optical coherence tomography with parallel spectrum detection is proposed and validated. The coherent noise is separated during one exposure by modulating the mutual delay of the signal and reference waves by a certain law. It is shown that the influence of internal motions in an object on the quality of the coherent noise separation can be reduced by the modulation frequency increasing. The technique has been numerically and experimentally validated with the help of an optical coherence tomography (OCT) setup with a radiation source operating at a wavelength of 1277 nm and a width of the recorded spectrum of about 100 nm.  相似文献   

14.
Schmitt JM  Xiang SH 《Optics letters》1998,23(13):1060-1062
We have observed that cross-polarized backscatter measured by optical coherence tomography of human skin in vivo is surprisingly strong. We identify and give evidence of its main origins: single scattering from nonspherical particles and multiple scattering by particles with sizes much larger than a wavelength. Our findings show that depolarized light scattered by dense large-diameter particles maintains a high degree of temporal coherence and that differential-polarization imaging improves contrast between particles of different sizes.  相似文献   

15.
戴云  张雨东  史国华 《光学学报》2006,26(11):666-1670
通过将计算层析技术与光学相干层析技术相结合,测量散射介质非均匀折射率分布。该方法测量散射样品折射率分布时,通过光学相干层析技术测量散射样品折射率分布在多个方向上的投影,采用计算层析技术实现对样品折射率分布的层析重建,克服了传统折射率光学测量方法如单纯的基于光学相干层析原理的焦点追迹法和光程匹配法,不能测量散射介质非均匀折射率分布的缺点。采用该方法在实验中对梯度折射率棒的径向相对折射率分布进行层析重建,取得了较好的实验结果。  相似文献   

16.
基于光学相干层析术的组织光学性质测量   总被引:1,自引:0,他引:1  
王凯  丁志华  王玲 《光子学报》2008,37(3):523-527
通过在光学相干层析成像(Optical Coherence Tomography,OCT)模型中考虑多重散射的影响,提出了一种提取出不同深度处的组织光学性质,包括散射系数和各向异性因子的算法.当把吸收系数作为算法中的第三个拟合参量时,能减少算法拟合过程中由于吸收作用的影响而带来的误差.基于包含吸收因子的OCT扩展模型,改进的算法也能够提取出吸收系数.这些算法的有效性通过对聚苯乙烯微球溶液样品的测量实验得到验证.  相似文献   

17.
贾亚青  梁艳梅  朱晓农 《物理学报》2007,56(7):3861-3866
对传统的模拟介质散射响应函数的蒙特卡罗算法的计算过程进行了改进,提出光子不可分割的假设,这样可以避免人为选定光子被吸收阈值的不确定性;同时采用双曲线法模拟入射高斯光束,解决了对表面为非平面介质的传输信号进行模拟的问题.通过对盖玻片(平面)与眼角膜(曲面)的光学相干层析探测信号及层析图的数值模拟,并与相应实验结果进行比较,证实了该方法与假设的可行性. 关键词: 光学相干层析 蒙特卡罗法模拟 散射  相似文献   

18.
We present theoretical calculations, based on a random phasor sum model, which show that the optical coherence tomography speckle contrast ratio is dependent on the local density of scattering particles in a sample, provided that the effective number of scatterers in the probed volume is less than about five. We confirm these theoretical predictions experimentally, using suspensions of microspheres in water. The observed contrast ratios vary in value from the Rayleigh limit of 0.52 to in excess of 2, suggesting that the contrast ratio could be useful in optical coherence tomography, particularly when imaging in ultrahigh-resolution regimes.  相似文献   

19.
We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues and materials with known optical properties. The device could be used to exploit the refractive index variations of tissue for medical and biological diagnostics accessible by needle insertion.  相似文献   

20.
We report on the scattering properties of oxygenated and deoxygenated whole blood from 250 to 1000 nm. We determine the complex refractive index of oxygenated and deoxygenated hemoglobin using a Kramers-Kronig analysis and optical coherence tomography measurements. Combining these data with Mie theory, the scattering properties are calculated. The strong oxygen saturation dependent scattering effects should be taken into account in the data analysis of optical oxymetry.  相似文献   