首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The review gives a link between the theory of adsorption from multicomponent solutions and liquid chromatography. The article surveys the methods developed to describe the retention in normal-phase chromatography with ternary mobile phases with emphasis on the results of the authors. In the model used the driving force for the separation is the difference in adsorption of a solute and all solvents onto the solid surface. The general equation generates a series of simple linear relationships to predict the retention factor in ternary mobile phase for which certain parameters remain fixed. Theoretical concepts are tested by comparison with experimental data. The correlations between parameters characterizing retention in ternary, binary and pure solvents are discussed.  相似文献   

2.
The model for retention in chromatographic systems using ternary mobile phases is considered. The driving force for the separation is assumed to be only a difference in adsorptive properties of a solute and all solvents. The effects of mobile phase composition are discussed. A series of very simple dependences between parameters characterizing retention in ternary and binary solvents is presented. The linear relationship is proposed to predict the capacity factor in the ternary mobile phase, for which the ratio of mole fractions of two less-polar solvents remains fixed. Theoretical concepts are verified by comparing the calculated values with experimental data measured in the entire concentration region.  相似文献   

3.
T. Kowalska 《Chromatographia》1990,29(7-8):389-394
Summary In our previous publication we have introduced a new model of solute retention in RP-HPLC systems with ternary mobile phases of the B+AB1+AB2 type (B: acetonitrile or tetrahydrofuran; AB1: methanol; AB2: water). That model proposed no stoichiometric differentiation between acetonitrile and tetrahydrofuran, alternatively present in the solvent system; moreover, it made some very rough assumptions only as to the intermolecular interactions among the mobile phase constituents.This paper introduces a significant refinement to the already established retention model, which is based on the simple quantitative relationships between acetonitrile and tetrahydrofuran, and the remaining components of the ternary liquid system. The refined model is tested with same experimental data.  相似文献   

4.
Summary In the proposed concept an eluate is considered to be an information source and the chromatographic column as a non specific receptor capable of understanding the information content. Molecular negentropy, estimated using Shannon's equation has been used as a measure of the information content. Retention of some experimental solutes has been shown to vary with the respective negentropy.  相似文献   

5.
The effect of varying mobile phase composition across a ternary space between two binary compositions is examined, on four different reversed-phase stationary phases. Examined stationary phases included endcapped C8 and C18, as well as a phenyl phase and a C18 phase with an embedded polar group (EPG). Mobile phases consisting of 50% water and various fractions of methanol and acetonitrile were evaluated. Retention thermodynamics are assessed via use of the van’t Hoff relationship, and retention mechanism is characterized via LSER analysis, as mobile phase composition was varied from 50/50/0 water/methanol/acetonitrile to 50/0/50 water/methanol acetonitrile. As expected, as the fraction of acetonitrile increases in the mobile phase, retention decreases. In most cases, the driving force for this decrease in retention is a reduction of the enthalpic contribution to retention. The entropic contribution to retention actually increases with acetonitrile content, but not enough to overcome the reduction in the enthalpic contribution. In a similar fashion, as methanol is replaced with acetonitrile, the v, e, and a LSER system constants change to favor elution, while the s and c constants change to favor retention. The b system constant did not show a monotonic change with mobile phase composition. Overall changes in retention across the mobile phase composition range varied, based on the identity of the stationary phase and the composition of the mobile phase.  相似文献   

6.
Water rich mobile phases in RPLC are not generally used because of the longer retention times involved when organic modifiers such as methanol or acetonitrile are used. The problem of longer retention times can be addressed using hydrophobic alcohols such as pentanol in low quantities (less than 1%) as organic modifiers. The advantages of using these mobile phases in RPLC for the separation of water soluble and weakly retained congeners is demonstrated through the separation of imidacloprid and its degradation products using a 0.4% pentanol in water mobile phase with 0.2% acetic acid.  相似文献   

7.
Summary The stepwise procedure described previously [1] for the selection of optimal mobile phase compositions in reversed phase liquid chromatography (RPLC) is improved in two ways. The optimization criterion is modified to account for variations in analysis time. The iterative approach to the optimal solvent composition makes a more efficient use of previous data. An example illustrates the resulting gain in speed and accuracy.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

8.
Young TE  Ecker ST  Synovec RE  Hawley NT  Lomber JP  Wai CM 《Talanta》1998,45(6):1189-1199
Reversed phase high-performance liquid chromatography (RP-HPLC) is demonstrated for hydrophobic analytes such as aromatic hydrocarbons on a chemically bonded stationary phase and a mobile phase consisting of only water. Reversed phase liquid chromatography separations using a water-only mobile phase has been termed WRP-LC for water-only reversed phase LC. Reasonable capacity factors are achieved through the use of a non-porous silica substrate resulting in a chromatographic phase volume ratio much lower than usually found in RP-HPLC. Two types of bonded WRP-LC columns have been developed and applied. A brush phase was synthesized from an organochlorosilane. The other phase, synthesized from an organodichlorosilane, is termed a branch phase and results in a polymeric structure of greater thickness than the brush phase. A baseline separation of a mixture containing benzaldehyde, benzene, toluene, and ethyl benzene in less than 5 min is demonstrated using a water mobile phase with 12 000 plates generated for the unretained benzaldehyde peak. The theoretically predicted minimum reduced plate height is also shown to be approached for the unretained analyte using the brush phase. As an application, subcritical water extraction (SWE) at 200°C is combined with WRP-LC. This combination allows for the extraction of organic compounds from solid matrices immediately followed by liquid chromatographic separation of those extracted compounds all using a solvent of 100% water. We demonstrate SWE/WRP-LC by spiking benzene, ethyl benzene, and naphthalene onto sand then extracting the analytes with SWE followed by chromatographic separation on a WRP column. A sand sample contaminated with gasoline was also analyzed using SWE/WRP-LC. This extraction process also provides kinetic information about the rate of analyte extraction from the sand matrix. Under the conditions employed, analytes were extracted at different rates, providing additional selectivity in addition to the WRP-LC separation.  相似文献   

9.
A series of commercial monomeric and polymeric C(18), C(27), and C(30) stationary phases were compared with immobilized poly(ethylene-co-acrylic acid) stationary phases synthesized in-house. The columns were characterized on the basis of methylene selectivity, silanol activity, metal activity, pore size, shape selectivity, and the ability to separate tocopherol isomers and carotenoid isomers. Monomeric and polymeric C(30) phases were shown to yield excellent separations of the tocopherol isomers while the polymeric C(30) and polyethylene phases were more appropriate to the separation of carotenoids.  相似文献   

10.
An extension of the treatment adopted in a recent paper [P. Nikitas, A. Pappa-Louisi, P. Agrafiotou, J. Chromatogr. A 946 (2002) 33] was used to derive expressions describing the variation of solute retention k with composition in ternary reversed phase liquid chromatography, RP-LC, solvent systems. The equation of the partition model obtained in this way for a ternary mobile phase was identical to that previously derived using the solubility parameter concept. This equation as well as two new expressions of In k versus organic modifiers content were tested in a variety of ternary solvent systems in order to examine the possibility of predicting retention behavior of solutes under ternary solvent mixture elution conditions from known retention characteristics in binary mobile phases. It was demonstrated the superiority of both new equations derived in this paper to that previously proposed and applied to date in ternary solvent mixtures.  相似文献   

11.
Chromatographic analysis of ionic liquids on different types of packings offers interesting possibility to determine their retention mechanism. As a consequence, the major interactions between stationary phase ligands and analyzed chemical entities can be defined. The main aim of this work was to analyze cations of ionic liquids on chemically bonded stationary phases with specific structural properties. The attempt to predict the main interactions between positive ions of ionic liquids and stationary phase ligands was undertaken. For that purpose, butyl, octyl, octadecyl, phenyl, aryl, mixed, alkylamide, and cholesterolic packings were chosen and applied to the analysis of six most commonly used ionic liquids' cations. Obtained results indicate mainly dispersive and pi-pi type of interaction part in the retention mechanism of analyzed compounds.  相似文献   

12.
The dependence on mobile phase composition of the retention of selected test analytes in different normal- and reversed-phase chromatographic systems is studied. The aim of this study is to compare the performance of six valuable retention models reported in the literature with a new empirical equation, which is first introduced in this study. All of these models are compared for different thin-layer chromatographic and high-performance liquid chromatographic systems by use of three criteria: the sum of the squared differences between the experimental and theoretical data, approximation of the standard deviation, and the Fisher test.  相似文献   

13.
The main aim of the present investigation was to study the retention and separation of eight nucleotides with the use of seven stationary phases in RP HPLC mode. Two octadecyl columns were used; however, aminopropyl, alkylamide, cholesterol, alkyl-phosphate, and phenyl were also studied. Special attention was paid to the mobile phase buffer pH, since it appears that this factor is very influential in the case of chromatographic separation of nucleotides. The retention of nucleotides was greater for mobile phase pH?4.0 in comparison with pH?7.0 (except for octadecyl and phenyl packing). This is a consequence of protonization of polar groups present on the stationary phase surface. It was proved that aminopropyl, alkyl phosphate, alkylamide packing materials are not suitable for the resolution of nucleotides. On the other hand, cholesterol and phenyl stationary phases are alternatives for conventional octadecyl phases. Application of cholesterol packing allows separation of small, polar nucleotides, which is impossible to achieve in the case of octadecyl phase. Moreover, a phenyl support allows separation of nucleotides in a shorter time in comparison with octadecyl packing.  相似文献   

14.
Summary New polyacrylate liquid crystalline compounds were coated onto glass or fused-silica capillary columns as stationary phases and applied to supercritical fluid chromatography. These stationary phases, were very stable: no bleeding was observed at 200°C and up to 200kg/cm2 pressures of carbon dioxide mobile phase. The wide working range of the capillary column was extended below the g-n transition temperature. Isomeric compounds such as - and -methoxynaphthalene, anthracene and phenanthrene and several phenolic compounds were separated.  相似文献   

15.
16.
The retention behaviour of thiazolylazo derivatives, 4-(2-thiazolylazo) resorcinol (TAR), 4-(2-thiazolylazo)-orcinol (TAO), 2-(2-thiazolylazo)-4-methylphenol (TAC) and 1-(2-thiazolylazo)-2-naphtol (TAN) was studied by reversed phase liquid chromatography. The optimum conditions for the separation of four thiazolylazo derivatives were examined with respect to column, flow rate, mobile phase composition and pH of mobile phase. These derivatives were separated simultaneously on Symmetry C8 column using composition of acetonitrile/water (60/40, v/v) as mobile phase. The capacity factor (k′) has been decreased at higher pH than pKa of solute which may due to the increasing concentration of the ionized species as increase the pH of mobile phase. The dependence of log k′ on the volume faction of water in the binary mobile phase and k′ on the liquid–liquid extraction distribution ratio (Dc) in acetonitrile–water (60/40, v/v)/n-octane extraction system for thiazolylazo derivatives were obtained good linear relationship. The results showed that the retention behaviour of these derivatives was mainly affected by the hydrophobic interaction between thiazolylazo as solute and mobile phase.  相似文献   

17.
18.
Ehab F. Elkady 《Talanta》2010,82(4):1604-1607
New, simple, rapid and precise reversed phase liquid chromatographic (RP-LC) method has been developed for the simultaneous determination of diclofenac potassium (DP) and methocarbamol (MT) in ternary mixture with guaifenesin (GF), degradation product of methocarbamol. Chromatographic separation was achieved on a Symmetry® Waters C18 column (150 mm × 4.6 mm, 5 μm). Gradient elution based on phosphate buffer pH (8)-acetonitrile at a flow rate of 1 mL min−1 was applied. The UV detector was operated at 282 nm for DP and 274 nm for MT and GF. Linearity, accuracy and precision were found to be acceptable over the concentration ranges of 0.05-16, 0.5-160 and 0.5-160 μg mL−1 for DP, MT and GF, respectively. The optimized method proved to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical preparation.  相似文献   

19.
Summary The relationship between the logarithmic capacity factor measured in reversed-phase liquid chromatography and the operating conditions including the mobile phase composition and the column temperature is investigated. The strategy described herein can offer the possibility to predict the retention of polycyclic aromatic hydrocarbons without any experiments and standard materials, by utilizing equations describing the relationships between retention, temperature, mobile phase composition and physicochemical properties of the solutes previously stored in the program of the microcomputer-assisted retention prediction system.This concept is one of the most promising techniques for the optimization of the separation conditions in reversed-phase liquid chromatography.  相似文献   

20.
Effect of temperature in reversed phase liquid chromatography   总被引:1,自引:0,他引:1  
The high temperature liquid chromatography (HTLC) reveals interesting chromatographic properties but even now, it misses some theoretical aspects concerning the influence of high temperature on thermodynamic and kinetic aspects of chromatography: such a knowledge is very essential for method development. In this work, the effect of temperature on solute behavior has been studied using various stationary phases which are representative of the available thermally stable materials present on the market. The thermodynamic properties were evaluated by using different mobile phases: acetonitrile-water, methanol-water and pure water. The obtained results were discussed on the basis of both type of mobile phases and type of stationary phases. Type of mobile phase was found to play an important role on the retention of solutes. The kinetic aspect was studied at various temperatures ranging from ambient temperature to high temperature (typically from about 30 to 200 degrees C) by fitting the experimental data with the Knox equation and it was shown that the efficiency is improved significantly when the temperature is increased. In this paper, we also discussed the problem of temperature control for thermostating columns which may represent a significant source of peak broadening: by taking into account the three main parameters such as heat transfer, pressure drop and band broadening resulting from the preheating tube, suitable rules are set up for a judicious choice of the column internal diameter.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号