首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
One of the reasons for the immense interest in capillary electrochromatography (CEC) is its feature to combine chromatographic selectivity with the high efficiency and the miniaturization potential of capillary electrophoresis (CE). The capability of commercial CE instruments to run CEC has enforced the readiness of users and researchers to work on this separation technique. Nevertheless, to fully exploit the potential of CEC, a routine CE device can certainly not fulfill all requirements. Two different approaches have been made to overcome this problem. The first was to modify commercial CE instruments for various demands. Pressurization of the packed capillary to prevent "air" bubble formation, gradient elution capabilities and thermostating devices allowing a greater flexibility in column designs have been implemented in CE instruments of several manufacturers. A completely different approach is the development of modular laboratory-made instrumentation dedicated to special CEC requirements. In order to increase mobile phase velocity and thus the speed of analysis the availability of voltages higher than 30 kV was accomplished in some of these devices. Gradient elution was achieved by either coupling of gradient LC systems or an electroosmotic generation of the changing eluent composition. When a pressure gradient is applied between both column ends in addition to the voltage gradient, a hybrid between capillary HPLC and CEC results. This chromatographic mode is named pressure-assisted electrochromatography (PEC). Either CE instruments equipped with additional HPLC pumps or modular laboratory-made devices are suitable for PEC. In CEC, sensitivity for UV detection is rather poor due to the short optical path length for on-column detection in capillary separation techniques. A special cell design with enhanced light path is presented and further principles like, e.g., fluorescence detection and coupling to mass spectrometry are discussed.  相似文献   

2.
分子印迹整体柱在高效液相色谱和电色谱手性分离中的应用   总被引:15,自引:0,他引:15  
在常规不锈钢色谱管中以甲基丙烯酸为功能单体,采用原位聚合法制备了(5S,11S)-特罗格尔碱(S-TB)的印迹整体柱。考察了流动相中添加不同量的醋酸和水对分离的影响,结合台阶梯度洗脱模式在S-TB整体柱上实现了对TB消旋体的快速分离。另外,以碱性单体2-二甲基乙基胺甲基丙烯酸酯(DAMA)为功能单体,在毛细管中采用原位聚合法制备了毛细管分子印迹整体柱,用于在毛细管电色谱(CEC)中对消旋体1,1′-联-2-萘酚(BNL)进行手性分离。结果表明,以AMA为功能单体可以制备其他酸性模板的分子印迹聚合物,从而扩大了分子印迹聚合物MIP)在CEC分离中的应用范围。  相似文献   

3.
毛细管电色谱和加压毛细管电色谱的进展与应用   总被引:2,自引:1,他引:1  
毛细管电色谱(CEC)以内含色谱固定相的毛细管为分离柱,以电渗流为驱动力,既可以分离带电物质也可以分离中性物质。它结合了毛细管电泳和高效液相色谱两者的优点,兼具高柱效、高分辨率、高选择性和高峰容量的特点,同时具有色谱和电泳的双重分离机理。然而,“纯粹”的电色谱在实际应用中有着天然的弱点,即: 在电流通过毛细管柱中的流动相时容易产生气泡(焦耳热作用),从而使电流中断和电渗流停止,毛细管柱必须被重新用流动相润湿后方能再次使用。加压毛细管电色谱(pCEC)将液相色谱中的压力流引入CEC系统中,不仅解决了气泡、干柱等问题,而且实现了定量阀进样和二元梯度洗脱。CEC和pCEC作为微分离领域的两种前沿技术,满足了当前复杂样品分析和分析仪器微型化的需求,近年来获得了广泛的关注。本文综述了这两种技术近来的发展,包括仪器、色谱固定相的发展,总结了其在生命科学、药物分析、食品安全以及环保样品分析等方面的应用进展,评述了各方法的特点,并展望了CEC和pCEC今后的发展和应用前景。  相似文献   

4.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

5.
张庆合  张凌怡  张维冰  李彤  张玉奎 《分析化学》2004,32(10):1283-1286
以十二烷基键合氧化锆(C12-ZrO2)作为固定相,制备了填充毛细管电色谱(CEC)柱,较为系统地研究了流动相条件对电渗流的影响、填充CEC柱的稳定性、碱性与中性化合物的保留与流动相pH值和有机溶剂含量的关系。C12-ZrO2固定相填充CEC柱在pH3~11.7范围内具有极好的稳定性;利用磷酸盐与氧化锆表面之间较强的相互作用,能够有效解决传统硅胶键合烷基固定相在有机溶剂含量低的流动相条件下不稳定的问题;同时吸附磷酸盐的固定相表面使得在更宽的流动相pH值范围内CEC柱有足够的电渗流,进一步拓宽CEC的应用领域。  相似文献   

6.
Silica-based, tentacular weak cation-exchanger particles were prepared for use as the stationary phase in the separation of positively charged sample components by capillary electrochromatography (CEC). Silica beads were first silanized with 3-(trimethoxysilyl) propyl methacrylate that served as a heterobifunctional linker, which reacted with 2-acrylarmidoglycolic acid in a second step by radical polymerization in aqueous solution. Baseline separation of basic peptides with good column efficiency was obtained on packed capillary columns by isocratic elution CEC with NaCl as the mobile phase modulator. The retention mechanism in the electrochromatographic process was studied by examining the effect of salt concentration on the migration behavior of the peptides. The chromatographic retention factor k'(lc) for charged sample components in the electrochromatographic process was estimated on the assumption that the overall migration rate of a charged migrant can be taken as the sum of the rate of chromatographic elution and the rate of electrophoretic migration. The estimated k(lc) values from experimental results were plotted against the molal salt concentration on a double logarithmic scale. The linear correlation is in good agreement with the prediction by the theory on the basis of traditional ion-exchange chromatography. The comparison of CEC results, obtained with open tubular and packed capillary columns having the same retentive functions as the stationary phase, supports the notion that variation of the phase ratio in the column offers an additional means to modulate the electrochromatographic migration behavior.  相似文献   

7.
Monodisperse poly(glycidyl methacrylate-divinylbenzene) microspheres were functionalized with propyl sulfonic acid moieties to obtain beads negatively charged in a wide pH range. They were packed into fused-silica capillary of 50 micro, I.D. in order to separate proteins by capillary electrochromatography (CEC). Baseline separation of four basic proteins as well as three cytochrome c variants with an average column efficiency of 60,000 theoretical plates was obtained under isocratic elution conditions. The high efficiency is attributed to the uniformity of the column packing and the hydrophilic surface coverage of the polymer beads derived from the functionalization process. The effect of pH and salt concentration on protein separations was investigated and the results showed that the CEC separation mechanism is the combination of chromatographic retention and electrophoretic migration. Moreover, the column packed with the strongly acidic poly(glycidyl methacrylate-divinylbenzene) beads was also suitable for protein separations by micro-HPLC with a salt gradient. The comparison between the two kinds of elution modes shows that the column described here exhibited higher peak efficiency with isocratic elution in CEC than with gradient elution in micro-HPLC.  相似文献   

8.
Capillary electrochromatography (CEC) is an emerging technique that combines features of both micro-capillary high-performance liquid chromatography (microHPLC) and capillary electrophoresis (CE). This separation technique possesses high speed and the efficiency of an electro-driven system, while the selectivity and sample loadability compare to those of a packed capillary LC column. Since the separation mechanism is based on that of HPLC, the concept of isoeluotropic strength and selectivity of solvents as well as the on-column focusing techniques for sample introduction used in LC can be applied in CEC. This article examines some of these features of CEC in the context of our own experiences with the technique. More specifically, emphasis is placed on applications of CEC to the analysis of DNA adducts of polyaromatic hydrocarbons by coupling CEC to mass spectrometry. It is shown that, with proper selection of mixed organic modifiers in the mobile phase, i.e. ternary and quaternary mobile phases, complex DNA adduct mixtures derived from in vitro reactions can be separated isocratically with improved selectivity and much greater speed than by HPLC. Additionally, the speed of the analysis is further enhanced by employing a step gradient. Furthermore, CEC may be easily coupled to mass spectrometry such that the characterization of each isolated component from the mixtures is performed on-line with the separation. By using on-column focusing, the sample loadability onto a CEC column is improved.  相似文献   

9.
Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF than reversed-phase packings that is scarcely dependent on the pH of the eluent. Applying a potential in gradient elution reversed-phase nano-LC of peptides shortens the analysis time as compared to separations without a potential. Electrically assisted reversed-phase gradient elution nano-LC is a powerful separation tool for analysis of tryptic digests. Peptides can be successfully resolved in acidic organic mobile phase at pH 2-3 with and without trifluoroacid as ion pairing reagent under isocratic conditions. It is demonstrated that CEC with mixed mode packing and an eluent of pH 2.3 with varying acetonitrile content can be applied to monitor impurities in a synthetic peptide.  相似文献   

10.
Once a suitable stationary phase and column dimensions have been selected, the retention in liquid chromatography (LC) is traditionally adjusted by controlling the mobile phase composition. Solvent gradients enable achievement of good separation selectivity while decreasing the separation time as compared to isocratic elution. Capillary columns allow use of other programming parameters, i.e. temperature and applied electric fields, in addition to solvent gradient elution. This paper presents a review of programmed separation techniques in miniaturized LC, including retention modeling and method transfer from the conventional to micro- and capillary scales. The impact of miniaturized instrumentation on retention and the limitations of capillary LC are discussed. Special attention is focused on the gradient dwell volume effects, which are more important in micro-LC techniques than in conventional analytical LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow-splitting is used. The influence of temperature upon retention is also discussed, and applications where the temperature has been actively used for retention control in capillary LC are included together with the instrumentation utilized. Finally the possibilities of additional selectivity control by applying an electric field over a packed capillary LC column are discussed.  相似文献   

11.
多肽的反相梯度加压毛细管电色谱分离   总被引:4,自引:0,他引:4  
以C18为固定相,采用电压和压力联合驱动流动相,研究反相加压毛细管电色谱分离多肽;考察了加压电色谱中,电压对带电和中性物质迁移的影响,实现了梯度加压毛细管电色谱分离6种多肽;结果表明,加压电色谱可以很好地抑制气泡形成,实验结果准确,重复性好;梯度加压毛细管电色谱在复杂样品的分离分析中,具有很大的潜力。  相似文献   

12.
Wu R  Zou H  Fu H  Jin W  Ye M 《Electrophoresis》2002,23(9):1239-1245
The mixed mode of reversed phase (RP) and strong cation-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280,000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for t(0) and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.  相似文献   

13.
Zhang L  Zhang W  Ping G  Zhang Y  Kettrup A 《Electrophoresis》2002,23(15):2417-2423
A theoretical study on the velocity of electroosmotic flow (EOF) and the retention times of neutral solutes under multiple-step gradient of capillary electrochromatography (CEC) was carried out, focusing on that with three kinds of mobile phases. Through the model computations, the detaining time of the second kind of mobile phase in the column was proved to play an important role in affecting EOF. The variation speed of EOF was shown to be determined by the differences among dead times in different steps. In addition, the prediction of the retention times of 13 aromatic compounds under gradient mode was performed with the deduced equations. A relative error below 3.3% between the calculated and experimental values was obtained, which demonstrated the rationality of the theoretical deduction. Our study could not only improve the comprehension of stepwise gradient elution, but also be of significance for the further optimization of separation conditions in the analysis of complex samples.  相似文献   

14.
Capillary electrochromatography (CEC) is a liquid phase analytical separation technique that is generally carried out with packed capillary columns by electroosmotically driven mobile phase at high electric field strength. The analytes are separated by virtue of the differences in their distribution between the mobile and stationary phases and, if charged in their electrophoretic mobilities as well. It is thus considered a hybrid of liquid chromatography and capillary electrophoresis and is expected to combine the high peak efficiency of capillary zone electrophoresis (CZE) with the versatility and loading capacity of HPLC. This review explores the potential use of on-line mass spectrometric detection for CEC. It discusses key design issues that focus on the physical and electrical arrangement of the CEC column with respect to the electrospray orifice inlet. The salient features of the sheathless, sheath flow and liquid junction interfaces that are frequently employed while coupling a CEC column to an electrospray ionization mass spectrometry system are also highlighted. Possible configurations of the CEC column outlet that would obviate the need for pressurizing the capillary column are also presented. While coupling CEC with MS both the nature of the interface and the configuration of the column outlet will determine the optimal arrangement. The review also discusses bandspreading that occurs when a connecting tube is employed to transfer mobile phase from the column outlet to the atmospheric region of the electrospray source with a concomitant loss in sensitivity. Selected examples that highlight the potential of this technique for a wide range of applications are also presented.  相似文献   

15.
In electrochromatography, solvent electrophoretic mobility and solute partitioning are temperature dependent processes. If temperature variations are controlled, solute selectivity and analysis times can be tailored. In this study the feasibility of temperature programming in capillary electrochromatography (CEC) was demonstrated using a reversed-phase CEC mode. The outcome of programmed separations was compared with isothermal, isocratic and isorheic (constant flow) separations. The combined effects of column temperature and mobile phase flow-rate changes during the separation run, resulted in up to a 50% reduction in the separation run time, without adversely affecting the quality of separation. For capillary electrochromatography, temperature programming may be a valuable alternative to solvent programming modes because of the great technical difficulties associated with carrying out solvent gradient elution.  相似文献   

16.
Density gradients in packed capillary columns operating under the extreme pressure drops typical for solvating gas chromatography were investigated by on-column spectroscopic measurements and compared to a theoretical model. Laser-induced fluorescence was used to follow the elution of various analytes, and Raman spectroscopy was used to measure the density of the mobile phase, each with respect to column position. Mobile phase linear velocity initially increases gradually, and then rises rapidly near the column outlet. High flow rates near the column outlet are offset by a loss of mobile phase solvating power which ultimately limits the speed of separation. These results represent an extreme case for illuminating factors affecting supercritical fluid separation techniques in general.  相似文献   

17.
本文将电中性溶质在缓冲盐体系和无盐体系下的电渗流、分离选择性等进行了对比,从理论和实验两方面讨论了电中性溶质在无盐体系下的分离,提出了采用无盐流动相既可以增加电渗流也可以减小焦耳热的优势。反相毛细管电色谱的实验结果也充分证明了这一点。  相似文献   

18.
Monodisperse poly(glycidyl methacrylate-divinylbenzene) microspheres were prepared by a simple one-step dispersion polymerization process. Examination of the polymeric microspheres showed that they had a mean particle diameter of 3 microm and dual pore size distribution with mean pore diameters of 300 and 800 A. The microspheres were functionalized by introducing quaternary ammonium/octadecyl groups to obtain positively charged beads in a wide pH range. The functionalized beads were packed into fused-silica capillary having 50 microm inner diameter and used to separate erythromycin derivatives by capillary electrochromatography (CEC). These samples require gradient elution when separated by high-performance liquid chromatography (HPLC) or micro-HPLC, but with the new columns isocratic elution suffices for their separation by CEC. The column efficiency ranged from 40,000 to 50,000 theoretical plates.  相似文献   

19.
谢敏杰  冯钰锜  达世禄 《色谱》2000,18(6):503-507
 毛细管电色谱是近年发展起来的高效、高选择性的微分离技术。与一般的毛细管电泳和使用ODS反相填料的毛细管电色谱相比 ,含离子涂层柱的毛细管电泳和毛细管电色谱能提供较大且可控的电渗流 ,便于拓宽分离对象 ,优化分离条件。对使用含离子涂层柱的毛细管电泳和电色谱的特点、发展和应用状况进行了综述。  相似文献   

20.
The separation mechanism in capillary electrochromatography (CEC) is a hybrid differential migration process, which entails the features of both high-performance liquid chromatography and capillary zone electrophoresis, i.e., chromatographic retention and electrophoretic migration. The adsorption of the different sample components on the stationary phase can be modified by the presence of the electric field across the column. Here, we use our previously published approach to decouple chromatographic retention from electrophoretic migration that allows us to investigate the "modification" of the retention process in CEC. This paper presents a methodology for characterization of changes in the retention of neutral and charged sample components, under identical conditions of stationary and mobile phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号