首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A methodology for simultaneous preconcentration and determination of Cr(VI) from aqueous samples was developed using a membrane optode formed by physical inclusion of a Cr(VI) selective chromophore 1,5-diphenylcarbazide (DPC) into a plasticized cellulose triacetate matrix. The inclusion of an anion exchanger (Aliquat-336) was found to be effective for immobilization of both DPC and Cr(VI)-DPC complex in the optode matrix itself. The proportionality in intensity of the magenta color on the optodes loaded with varying amounts of Cr(VI) suggests its potential applications for screening of Cr(VI) in aqueous samples by visual colorimetry. On loading high amounts of Cr(VI) in the membrane optode, its color changes from magenta to yellow, which indicates the possibility of using it as a threshold detector for Cr(VI). The membrane optode was optimized in terms of obtaining maximum preconcentration efficiency for Cr(VI) and subsequent stable optical response proportional to the amount of Cr(VI) in the membrane optode sample. The membrane optodes were tested for Cr(VI) determination in tap water and seawater samples. Using this optode, Cr(VI) even at levels of 13.6 ppb could be quantitatively detected. The optodes developed in the present work were found to be stable, cost effective, easy to prepare and efficient for direct preconcentration and determination of Cr(VI) in a variety of aqueous samples using spectrophotometry. However, this membrane optode is for one time use only as the reaction of Cr(VI) with DPC is irreversible.  相似文献   

3.
A partial least-squares regression (PLS) was developed for the simultaneous spectrophotometric determination of aluminum and beryllium in geochemical samples by xylenol orange as the chromogenic reagent in water media and in micellar media. The effects of pH, xylenol orange concentration and surfactant concentration on the complexes formation reactions were studied. In the absence of surfactant the complex color development takes place at 2 h after mixing the reagents. By using CTAB as micellar media the complexes formation was improved and the rate of the complexation reactions increased. By using PLS-1 algorithm satisfactory results were obtained. The proposed procedure showed to be useful for prediction of Al and Be values from 0.1 to 1.0 mg L(-1).  相似文献   

4.
This study examined the direct spectrometric method for determining non-ionic surfactants in highly-polluted samples (i.e., soil leachates) containing high concentrations of humic acids. Meso-tetra-(3,5-dibromo-4-hydrooxyphenyl)-porphyrin served as a coloration agent. The method was tested by use of two polyethoxylate/polypropoxylate — based non-ionic surfactants: Triton CF-21 containing aromatic groups in the structure and Novanik 1047A containing only linear hydrocarbon chains. The main goal was to quantify the influence of interfering species to the results. A test for coincidence of regression lines was employed for objective evaluation of the humic acid influence on the determination. It was observed that for linear surfactant Novanik 1047 A the method provides reliable result and thus, can serve for routine analyses. Regarding Triton CF-21, an interfering effect of humic acids was observed; however, after sufficient dilution of the samples, the method can be used as well. Finally, the method can be used for simple analyses of problematic samples without complicated sample-pretreatment.   相似文献   

5.
Moneeb MS 《Talanta》2006,70(5):1035-1043
Polarographic chemometric methods were applied to the determination of zinc and nickel in aqueous solutions previously acidified with 0.1 M acetate buffer (pH 4.2). The studied methods are multivariate methods including classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS); derivative ratio methods (first, 1D and second, 2D derivative ratio). A comparative study was considered. The studied chemometric methods do not need the presence of any reduction potential shift reagent in spite of the great overlap between the two metals polarograms. A training set consisting of 10 binary mixture solutions in the possible combinations containing 0.13–9.30 μg/ml Zn(II) and 0.20–12.25 μg/ml Ni(II) was used to develop the chemometric calibrations (CLS, PCR and PLS). A validation set containing the synthetic mixtures in the range of 0.29–9.00 μg/ml for Zn(II) and 0.30–11.60 μg/ml for Ni(II) was used to validate the multivariate calibrations. Same mixtures were used to develop the derivative ratio methods. The polarograms were recorded and their current values were measured within the potential range −920 to −1052 mV at 2 mV intervals. The mean percentage recoveries obtained using CLS, PCR and PLS were found to be 99.5 ± 1.5%, 100.0 ± 1.1% and 100.0 ± 1.0% for Zn(II) and 99.4 ± 1.3%, 99.7 ± 1.2% and 99.9 ± 1.0% for Ni(II), respectively. The mean percentage recoveries obtained using 1D at −950 mV, 1D at −1010 mV, 1D at −950 mV–1D at −1010 mV and 2D at −986 mV for Zn(II) were found to be 99.7 ± 1.2%, 99.2 ± 1.6%, 99.4 ± 1.4% and 99.4 ± 1.4%; and using 1D at −1030 mV and 2D at −1010 mV for Ni(II) were found to be 100.5 ± 1.3% and 100.4 ± 1.3%, respectively. Interferences due to the presence of Cd, Co, Pb, Fe, Mn, Ca, Mg, Cu and Al were studied. The applicability of the proposed methods was assessed through the determination of both metals in tap drinking-water. Samples were subjected if required up to a 20-fold preconcentration step by microwaving in pyrex vessels. The results were compared with those obtained using the zincon and the heptoxime colorimetric reference methods for the determination of zinc and nickel, respectively.  相似文献   

6.
Burakham R  Oshima M  Grudpan K  Motomizu S 《Talanta》2004,64(5):1259-1265
A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03–0.30 μg NO2-N ml−1 and 0.10–1.00 μg NO3-N ml−1. The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9 ng NO2-N ml−1 and 2.3 ng NO3-N ml−1, respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples.  相似文献   

7.
The need for a rapid, sensitive and reliable analytical method for cyanobacterial toxins, microcystins, has been emphasized by the awareness of toxic cyanobacteria as a human-health risk through drinking water. A new high-performance liquid chromatographic method with column switching was developed for the determination of microcystin-LR, -RR and -YR from water samples without pre-purification. The filtered water sample was passed through a Zorbax CN precolumn at a flow-rate of 3 ml/min for on-line trace enrichment. After valve switching, concentrated analytes were eluted in back-flush mode and separated on a Luna C18 column with a gradient of acetonitrile -20 mM phosphate buffer (pH 2.5). The method showed excellent precision, accuracy and speed with detection limits of 0.02 microgram/ml from 100 ml of surface water. The total analysis time per sample was about 90 min. This method improves reliability, sensitivity and sample throughput, and shortens the analysis time compared to analysis methods using off-line solid-phase extraction.  相似文献   

8.
A simple, low cost and sensitive voltammetric sensor was developed for the simultaneous detection of Pb2+, Cd2+, and Zn2+ based on a disposable carbon fiber rod (CFR). The important factors to enhance the sensing property were creation of a clean surface by dealing with CFR at a high potential and electrochemical deposition of Bi film to improve the accumulation of heavy metal ions.  相似文献   

9.
In this work, simultaneous determination of low levels of 226Ra and uranium in aqueous samples were performed by alpha-liquid scintillation counting (LSC) in conjunction with artificial neural network (ANN) and partial least squares (PLS). The counting rates at 73 channels, which were selected by genetic algorithm, were used for training. A PLS model with four latent variables and a principle component ANN model (4-4-2) with linear transfer function after hidden and output layers were created. Total relative error of prediction for PLS and ANN in synthetic mixtures was 18.05% and 24.78%, respectively. The matrix effect was studied by spiking the real samples with radium and uranium. Laser induced fluorescence was used for assessment of uranium prediction results in real samples.  相似文献   

10.
An approach to choosing analyte preconcentration conditions for the subsequent capillary electrophoresis (CE) analysis of the concentrate was substantiated using the simultaneous determination of zinc(II) and cadmium(II) trace concentrations as an example. A CE procedure was developed for the determination of Zn and Cd with the following characteristics: The time of the analysis, including analyte preconcentration from a 50-mL sample, was 30 min. The analytical ranges were 0.01–0.2 mg/L for cadmium(II) and 0.005–0.1 mg/L for zinc(II).  相似文献   

11.
Dutra RL  Maltez HF  Carasek E 《Talanta》2006,69(2):488-493
An on-line preconcentration system for zinc determination in 24-h urine, blood plasma and erythrocyte matrices by flame atomic absorption spectrometry (FAAS) was used. This procedure was based on adsorption of Zn(II) ions onto a minicolumn filled with silica gel, chemically modified with niobium(V) oxide (Nb2O5-SiO2). The determination of the optimum conditions for Zn(II) preconcentration was done using two-level full factorial and Doehlert designs. In the optimization procedure, four variables (sample pH, eluent concentration, sample flow rate and eluent flow rate) were investigated. The results obtained from the full factorial design demonstrated that the sample pH and sample flow rate variables, and their interactions, were statistically significant. A Doehlert matrix was used in order to determine the optimum conditions for the sample pH and sample flow rate. The optimized conditions for sample pH and flow rate sampling were 6.6 and 7.1 ml min−1, respectively, to obtain the maximum Zn(II) preconcentration and determination in the biological samples studied. Parameters of analytical curve, precision, effect of other ions in the proposed system and accuracy were achieved to assess the proposed method. The accuracy was confirmed by analysis of certified reference materials (urine Seronorm™ Trace Elements) and recovery tests in blood plasma and erythrocyte samples. Detection limit (3σ/S) of 0.77 μg l−1, precision (calculated as relative standard deviation) of 1.5% for Zn(II) concentration of 10 μg l−1 (n = 7) and a sampling frequency of 27 samples/h were obtained from the proposed system.  相似文献   

12.
Three kinetic methods based on flow injection, flow, and stopped-flow injection were applied for the determination of Cd(II) using a flow-through bulk optode membrane that incorporates 1-(2-pyridylazo)-2-naphtol (PAN) in a plasticized poly(vinyl) chloride membrane entrapped in a cellulose support. The calibration graphs plotting the reflectance at 560 nm versus [Cd(II)](1/2) for the first two methods and versus [Cd(II)] for the third were linear up to 56.2 mg l(-1). The detection limits of the methods were 0.01, 0.06 and 0.8 mg l(-1), respectively. The FI method was selected for application purposes. The variation coefficient of the sensor response for 11.2 mg l(-1) of Cd(II) was +/-0.31 and +/-0.65% between different membranes. The sensor can be readily regenerated with a carrier (acetic-acetate) buffer of pH 4. The FI method was applied to the determination of cadmium in an alloy and in water.  相似文献   

13.
Sedaira H 《Talanta》2000,51(1):39-48
A new direct spectrophotometric determination of manganese with 5,8-dihydroxy-1,4-naphthoquinone (naphthazarin,NAZA) is reported. Absorption maximum, molar absorptivity and Sandell's sensitivity of 1:2 (M:L) complex are 695 nm, 1.88x10(4) l mol(-1) cm(-1) and 2.92 ng cm(-2), respectively. A linear calibration graph is obtained up to a concentration of 7.2 mug ml(-1) of manganese. The optimum range for determination (Ringbom) is between 0.20 and 6.8 mug ml(-1). A rapid method for simultaneous determination of manganese and zinc in their mixture using derivative spectra is described. The range 0.28-5.6 mug ml(-1) manganese could be determined in the presence of 0.33-6.8 mug ml(-1) zinc and vice versa. The developed method was applied to the simultaneous spectrophotometric determination of manganese and zinc in some synthetic mixtures and was found to give satisfactory results.  相似文献   

14.
In this article, the separation of zinc from aqueous samples by solid-phase extraction based on a molecular imprinting technique is described. Zn-imprinted polymer was prepared by free radical solution polymerisation in a glass tube containing ZnSO4, morin, 4-vinylpyridine as a functional monomer, ethyleneglycoldimethacrylate as a cross-linking monomer, and 2,2′-azobisisobutyronitrile as an initiator. The obtained polymer block was ground and sieved (55–75 µm) and the Zn–morin complex was separated from polymer particles by leaching with 2M HCl. The synthesised polymer particles have been characterised by IR and differential scanning calorimetric studies either before or after leaching. The effects of different parameters, such as pH, adsorption and desorption time, type and minimum amount of the eluent for elution of the complex from polymer were evaluated. Extraction efficiency more than 99% was obtained by elution of the polymers with 10 mL of CH2Cl2–dimethyl sulfoxide (1 : 1, v/v). The detection limit of the proposed method was 2.9 µg L?1. A dynamic linear range in the range of 25–200 µg L?1 was obtained. The relative standard deviation was found to be below 9.2%. In addition, the influence of various cationic and anionic interferences on the complex recovery was studied. The method was applied to the recovery and determination of Zn in a few different real samples.  相似文献   

15.
A simple sensor based on bare carbon ionic liquid electrode was fabricated for simultaneous determination of dihydroxybenzene isomers in 0.1 mol L−1 phosphate buffer solution (pH 6.0). The oxidation peak potential of hydroquinone was about 0.136 V, catechol was about 0.240 V, and resorcinol 0.632 V by differential pulse voltammetric measurements, which indicated that the dihydroxybenzene isomers could be separated absolutely. The sensor showed wide linear behaviors in the range of 5.0 × 10−7–2.0 × 10−4 mol L−1 for hydroquinone and catechol, 3.5 × 10−6–1.535 × 10−4 mol L−1 for resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 5.0 × 10−8, 2.0 × 10−7, 5.0 × 10−7 mol L−1, respectively (S/N = 3). The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater and the recovery was from 93.9% to 104.6%.  相似文献   

16.
A method is suggested for the determination of submicrogram Cd in quantities by isotope dilution, using substoichiometric extraction into dithizone in chloroform. The applicability of the method was tested in biological samples. Extraction was carried out from a sodium acetate buffer betweenpH 9.7 and 12.0. With amounts of 0.2 μg of Cd, the S.E. was not greater than 0.01 μg. This method is suitable for large scale analysis of trace amounts of Cd in biological materials.  相似文献   

17.
A selective and sensitive method for the determination of cadmium and zinc is presented. The method is based on the adsorptive accumulation of the complexes of Cd(II) and Zn(II) ions with 4-amiono-5-methyl-2.4-dihydro-3H-1,2,4-triazol-3-tion (MMTT) onto hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed species using a voltammetric scan using differential pulse modulation. The ligand concentration, pH, potential and time of accumulation, scan rate, and pulse height were optimized. Under the optimized conditions, a linear calibration curve was obtained for the concentration of Cd(II) and Zn(II) in the range of 5–450 and 5–850 ng/mL, respectively, with a detection limit of 1.7 ng/mL Cd(II) and 1.3 ng/mL Zn(II). The ability of the method was evaluated by analysis of cadmium and zinc in water and alloy samples The text was submitted by the authors in English.  相似文献   

18.
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L−1. With an accumulation period of 120 s detection limits of 0.09 ng mL−1, 0.06 ng L−1 and 0.08 ng L−1 were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry.  相似文献   

19.
A simple one-dimensional model for aqueous solution is applied to study the solvation thermodynamics of a simple solute (here, a hard-rod particle) in mixtures of waterlike particles and a cosolvent. Two kinds of cosolvents are considered, one that stabilizes and one that destabilizes the "structure of water." The results obtained for the Gibbs energy, entropy, enthalpy, and heat capacity of solvation are in qualitative agreement with experimental data on the solvation of argon and methane in mixtures of water and ethanol and of water and p-dioxane.  相似文献   

20.
Zinc ions form a yellow complex with di-2-pyridyl ketone salicyloylhydrazone (DPKSH). This complex showed maximum absorption at 376 nm, and it was used to develop spectrophotometric flow injection methods for Zn(II) determination in different samples. Two types of flow systems were proposed. In the first system, a linear analytical curve was obtained in a concentration range from 0.217 to 4.60 mg L(-1) Zn(II), with a detection limit of 48.8 microg L(-1). In the second system, a minicolumn packed with an anion exchanger resin was used to concentrate Zn(II) as a chlorocomplex, and a linear analytical curve within a concentration range from 0.0824 to 2.06 mg L(-1) Zn(II) was obtained, having a detection limit of 13.9 microg L(-1). The developed methods were applied to biological and pharmaceutical samples, and a great compliance was observed by comparing the results with ones obtained by an atomic absorption technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号