首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Behar V  Adam D 《Ultrasonics》2004,42(10):1101-1109
A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizes the signal-to-noise ratio (SNR) and minimizes sidelobes at the output of the compression filter. A pulse with linear frequency modulation (LFM) is used for coded excitation. The excitation/compression scheme is based on the fast digital mismatched filtering. The parameter optimization of the excitation/compression scheme includes (i) choice of an optimal filtering function for the mismatched filtering; (ii) choice of an optimal window function for tapering of the chirp amplitude; (iii) optimization of a chirp-to-transducer bandwidth ratio; (iv) choice of an appropriate n-bit quantizer. The simulation results show that the excitation/compression scheme can be implemented as a Dolph–Chebyshev filter including amplitude tapering of the chirp with a Lanczos window. An example of such an optimized system is given where the chirp bandwidth is chosen to be 2.5 times the transducer bandwidth and equals 6 MHz: The sidelobes are suppressed to −80 dB, for a central frequency of 4 MHz, and to −94 dB, for a central frequency of 8 MHz. The corresponding improvement of the SNR is 18 and 21 dB, respectively, when compared to a conventional short pulse imaging system. Simulation of B-mode images demonstrates the advantage of coded excitation systems of detecting regions with low contrast.  相似文献   

2.
Ultrasonic pulse echo systems are often limited in range resolution by the bandwidth of the piezoelectric transducer. Significant improvements in the range resolution of such systems can be obtained by minimizing the effects of the transducer's dynamic response on the overall pulse echo process. An approach to minimize the effects of the transducer is developed from linear system and impulse response techniques. In essence, the pulse echo voltage of interest is deconvolved with a pulse echo reference voltage which is obtained from an air/water interface in the nearfield of the transducer . A computer study of the pulse echo process and the deconvolution process is presented to illustrate the nature of the improvement in range resolution for several cases of interest. Finally, experimental results are presented to illustrate the improvement using commercially available transducers.  相似文献   

3.
王强  毛捷  廉国选 《应用声学》2020,39(4):558-562
该文研究了不同编码带宽下超声换能器对编码信号脉冲压缩后信噪比与轴向分辨率的影响关系。将脉冲压缩后的时域峰值转化为频域积分的形式,得到考虑换能器影响的脉冲压缩信噪比公式。以线性调频信号为例,仿真与实验结果表明,编码激励相对于方波激励的信噪比增益随编码带宽的减小而增大,因为受换能器带宽限制,编码激励的轴向分辨率随编码带宽的增大先减小后趋于稳定。该研究为编码激励方法更有效地应用于超声检测的背景中提供了参考。  相似文献   

4.
Kim BH  Kim GD  Song TK 《Ultrasonics》2007,46(2):148-154
The compression error of post-compression based coded excitation techniques increases with decreasing f-number, which causes the elevation of side-lobe levels. In this paper, a post-compression based coded excitation technique with reduced compression errors through dynamic aperture control is proposed. To improve the near-field resolution with no frame rate reduction, the proposed method performs simultaneous transmit multi-zone focusing using two mutually orthogonal complementary Golay codes. In the proposed method, the two mutually orthogonal sequences of length 16 are simultaneously transmitted toward two different focal depths, which are separately compressed into two short pulses on receive after dynamic focusing is performed. After carrying out the same transmit-receive operation for the same scan line with the complementary set of the orthogonal Golay codes, a single scan line with two transmit foci is obtained.The computer simulation results using a linear array with a center frequency of 7.5 MHz and 60% 6 dB bandwidth show that the range side-lobe level can be suppressed below −50 dB, when f-number is maintained not smaller than 3. The performance of the proposed scheme for a smaller f-number of 2 was also verified through actual experiments using a 3.85 MHz curved linear array with 60% 6 dB bandwidth. Both the simulation and experimental results show that the proposed method provides improved lateral resolution compared to the conventional pre-compressed and post-compression based coded excitation imaging using Golay codes.  相似文献   

5.
Cowell DM  Freear S 《Ultrasonics》2008,48(2):98-108
A novel switched excitation method for linear frequency modulated excitation of ultrasonic transducers in pulse compression systems is presented that is simple to realise, yet provides reduced signal sidelobes at the output of the matched filter compared to bipolar pseudo-chirp excitation. Pulse compression signal sidelobes are reduced through the use of simple amplitude tapering at the beginning and end of the excitation duration. Amplitude tapering using switched excitation is realised through the use of intermediate voltage switching levels, half that of the main excitation voltages. In total five excitation voltages are used creating a quinary excitation system. The absence of analogue signal generation and power amplifiers renders the excitation method attractive for applications with requirements such as a high channel count or low cost per channel. A systematic study of switched linear frequency modulated excitation methods with simulated and laboratory based experimental verification is presented for 2.25 MHz non-destructive testing immersion transducers. The signal to sidelobe noise level of compressed waveforms generated using quinary and bipolar pseudo-chirp excitation are investigated for transmission through a 0.5 m water and kaolin slurry channel. Quinary linear frequency modulated excitation consistently reduces signal sidelobe power compared to bipolar excitation methods. Experimental results for transmission between two 2.25 MHz transducers separated by a 0.5 m channel of water and 5% kaolin suspension shows improvements in signal to sidelobe noise power in the order of 7–8 dB. The reported quinary switched method for linear frequency modulated excitation provides improved performance compared to pseudo-chirp excitation without the need for high performance excitation amplifiers.  相似文献   

6.
Most of the literature on coded excitation describes the signal-to-noise ratio gain of a coded waveform in terms of the time-bandwidth product. We have shown that in the context of ultrasound imaging, the expression for the SNR gain provided by matched filtering a coded waveform, can be reduced to the total number of chips in the transmit signal. Hence, the SNR gain is independent of both the bandwidth and the duration of a single-chip. This concept is described in detail, clarifying this seeming contradiction. The impact of bandwidth and pulse duration on the SNR, SNR gain and axial resolution is described. Bandwidth requirements and the impact of regulatory peak-power limitations are also addressed.  相似文献   

7.
This work reports the results of measurements of spatial distributions of ultrasound fields obtained from five energizing schemes. Three different codes, namely, chirp signal and two sinusoidal sequences were investigated. The sequences were phase modulated with 13 bits Barker code and 16 bits Golay complementary codes. Moreover, two reference signals generated as two and sixteen cycle sine tone bursts were examined. Planar, 50% (fractional) bandwidth, 15 mm diameter source transducer operating at 2 MHz center frequency was used in all measurements. The experimental data were collected using computerized scanning system and recorded using wideband, PVDF membrane hydrophone (Sonora 804). The measured echoes were compressed, so the complete pressure field in the investigated location before and after compression could be compared. In addition to a priori anticipated increase in the signal to noise ratio (SNR) for the decoded pressure fields, the results indicated differences in the pressure amplitude levels, directivity patterns, and the axial distance at which the maximum pressure amplitude was recorded. It was found that the directivity patterns of non-compressed fields exhibited shapes similar to the patterns characteristic for sinusoidal excitation having relatively long time duration. In contrast, the patterns corresponding to compressed fields resembled those produced by brief, wideband pulses. This was particularly visible in the case of binary sequences. The location of the maximum pressure amplitude measured in the 2 MHz field shifted towards the source by 15 mm and 25 mm for Barker code and Golay code, respectively. The results of this work may be applicable in the development of new coded excitation schemes. They could also be helpful in optimizing the design of imaging transducers employed in ultrasound systems designed for coded excitation. Finally, they could shed additional light on the relationship between the spatial field distribution and achievable image quality and in this way facilitate optimization of the images obtained using coded systems.  相似文献   

8.
Sodium MR imaging is considered to provide clinically important information about the human body that is not achievable by hydrogen-based approaches. However, due to the low natural abundance in biological tissues, sodium signals usually lead to low spatial resolution, low SNR, and long acquisition times compared to conventional 1H imaging, even using well-adapted surface coils. For our study, a volume coil was designed with nearly homogeneous excitation/receive characteristics and a suitable geometry fitting the human torso. A sufficient penetration throughout the entire thorax, abdomen, or pelvis is provided allowing for sodium imaging of the kidneys, the liver with gall bladder, or the myocardium. All measurements were performed on a 1.5 T whole body scanner using a spoiled 3-D gradient echo sequence. Imaging parameters TE, TR, and readout bandwidth were optimized for sensitive recording of the sodium component with slow transverse relaxation. Nonselective RF excitation pulses with a duration of 2.5 ms and rectangular shape were applied to avoid SAR problems. Narrow receiver bandwidth and excitation near the Ernst angle provided clinically practicable examinations with measuring times of less than 15 min at a spatial resolution of 8 x 8 x 8 mm3. Under these conditions, SNR of 11 for the kidneys and vertebral disks, 9 for the spinal canal, and 6 for the liver was achieved. A special 3-D spin echo sequence was used to determine T2, times which resulted to 15.3 +/- 1.1 ms for liver, 27.7 +/- 7.2 ms for kidneys, and 24.0 +/- 4.7 ms for the content of the spinal canal.  相似文献   

9.
张志甜  张超  王文炎  马廷锋  刘岩  冯冠平 《中国物理 B》2010,19(9):97701-097701
This paper investigates the properties of thickness extension mode excited by lateral electric field on LiNbO3 by using the extended Christoffel-Bechmann method. It finds that the lateral field excitation coupling factor for amode (quasi-extensional mode) reaches its maximum value of 28% on X-cut LiNbO3. The characteristics of a lateral field excitation device made of X-cut LiNbO3 have been investigated and the lateral field excitation device is used for the design of a high frequency ultrasonic transducer. The time and frequency domain pulse/echo response of the LiNbO3 lateral field excitation ultrasonic transducer is analysed with the modified Krimholtz-Leedom-Matthae model and tested using traditional pulse/echo method. A LiNbO3 lateral field excitation ultrasonic transducer with the centre frequency of 33.44 MHz and the -6 dB bandwidth of 33.8% is acquired, which is in good agreement with the results of the Krimholtz-Leedom-Matthae model. Further analysis suggests that the LiNbO3 lateral field excitation device has great potential in the design of broadband high frequency ultrasonic transducers.  相似文献   

10.
Three dimensional metabolite maps of protonated metabolites were obtained using 1H magnetic resonance spectroscopic imaging at 7 T. Surface coils were used to increase sensitivity and spatial resolution significantly over a volume coil two-dimensional acquisition. Adiabatic pulses were employed to provide homogeneous B1 excitation and frequency selective refocusing over the volume of the rat brain. These techniques were employed to obtain three-dimensional spectroscopic imaging spectra from nominal voxel volumes of 9–30 μl from rat brain. The improved spatial resolution and sensitivity are also demonstrated with studies of focal ischemia in the rat.  相似文献   

11.
A linear algebra based deprivation is presented to demonstrate that linearly time scaling an entire gradient waveform by a factor "R" exponentially increases its sensitivity to time derivatives of position by R(i + 1), where i refers to the i-th derivative of position (e.g., i = 1 is velocity). Thus, time scaling will preserve zero valued refocussing moments associated with artifact reduction techniques designed for motion occurring between excitation and detection. Typically, gradient waveforms for artifact reduction techniques are derived for use only at specific echo times. The time scaling described here allows for simple modification of refocussing gradient waveforms for use at variable echo times. Motion sensitivity associated with non-zero moment gradient waveforms can be easily predicted and modified using this technique, with consideration for field of view, resolution, and bandwidth. A clinical example is presented showing the predicted changes in sensitivity to nonrefocussed derivatives of position as the imaging gradients are time scaled. Further, trade-offs and alternatives in sensitivity to motion, slice thickness, image bandwidth, field of view and resolution will be discussed in conjunction with time scaling. This technique will have applicability in many situations involving MRI of moving tissue and a clinical example in cardiac imaging is presented.  相似文献   

12.
Scatterer size estimates from ultrasonic backscatter coefficient measurements have been used to differentiate diseased tissue from normal. A low echo signal-to-noise ratio (eSNR) leads to increased bias and variance in scatterer size estimates. One way to improve the eSNR is to use coded excitation (CE). The normalized backscatter coefficient was measured from three tissue-mimicking phantoms by using CE and conventional pulsing (CP) techniques. The three phantoms contained randomly spaced glass beads with median diameters of 30, 45, and 82 mum, respectively. Measurements were made with two weakly focused, single-element transducers (f(0)=5 MHz and f(0)=10 MHz). For CE, a linear frequency modulated chirp with a time bandwidth product of 40 was used and pulse compression was accomplished by the use of a Wiener filter. Preliminary results indicated that improved estimation bias versus penetration depth was obtained by using CE compared to CP. The depth of penetration, where the accuracy of scatterer diameter estimates (absolute divergence <25%) were obtained with the 10 MHz transducer, was increased up to 50% by using CE versus CP techniques. In addition, for a majority of the phantoms, the increase in eSNR from CE resulted in a modest reduction in estimate variance versus depth of penetration.  相似文献   

13.
Potential of coded excitation in medical ultrasound imaging   总被引:6,自引:0,他引:6  
Improvement in signal-to-noise ratio (SNR) and/or penetration depth can be achieved in medical ultrasound by using long coded waveforms, in a similar manner as in radars or sonars. However, the time-bandwidth product (TB) improvement, and thereby SNR improvement is considerably lower in medical ultrasound, due to the lower available bandwidth. There is still space for about 20 dB improvement in the SNR, which will yield a penetration depth up to 20 cm at 5 MHz [M. O'Donnell, IEEE Trans. Ultrason. Ferroelectr. Freq. Contr., 39(3) (1992) 341]. The limited TB additionally yields unacceptably high range sidelobes. However, the frequency weighting from the ultrasonic transducer's bandwidth, although suboptimal, can be beneficial in sidelobe reduction. The purpose of this study is an experimental evaluation of the above considerations in a coded excitation ultrasound system. A coded excitation system based on a modified commercial scanner is presented. A predistorted FM signal is proposed in order to keep the resulting range sidelobes at acceptably low levels. The effect of the transducer is taken into account in the design of the compression filter. Intensity levels have been considered and simulations on the expected improvement in SNR are also presented. Images of a wire phantom and clinical images have been taken with the coded system. The images show a significant improvement in penetration depth and they preserve both axial resolution and contrast.  相似文献   

14.
The generation of tissue harmonics is due to nonlinear nature of ultrasound wave propagation in biological tissues.The tissue harmonics for imaging i.e.tissue harmonic imaging (THI)uses higher frequency components for imaging in which the resolution improves significantly but signal-to-noise ratio(SNR)and penetration depth remains low as compared to both fundamental and second harmonic imaging.The coded excitations have potential to improve the SNR which ultimately leads to improved penetration depth.In the present work,the linear frequency modulated(chirp/LFM)and nonlinear frequency modulated(NLFM)signals have been used to investigate the nonlinear ultrasound wave propagation and harmonic generation in biological tissues.The SNR has been found to be substantially improved for coded tissue harmonic imaging(CTHI)as well as for coded superharmonic imaging(CSHI).  相似文献   

15.
Peng H  Han X  Lu J 《Ultrasonics》2006,44(Z1):e93-e96
The high frame rate (HFR) ultrasonic imaging system, which is developed with limited diffraction beams, constructs images at a high frame rate. However the rectangular imaging area, to some extent, restricts the far field imaging information. At the same time, by virtue of one transmission event for constructing image, the system suffers from low SNR. In this paper we present a computationally efficient method to construct sector mode image and to increase the SNR in HFR system. The method uses orthogonal complementary Golay coded excitation to realize two transmit and receive events. Each emission simultaneously transmits two plane waves with different transmission angle. Then according to Golay code orthogonality, the received echo signals related to different angles are isolated and used to construct two images of different imaging area by HFR method. Finally the two images are synthesized to one frame of sector mode image.  相似文献   

16.
龚燕君  章东  郗晓宇  龚秀芬  刘政 《物理学报》2007,56(12):7051-7057
超声造影剂的次谐波成像可以提高造影组织比,提供更好的图像质量. 提出一种利用调频脉冲激励以增强造影剂微气泡产生的次谐波新方法. 基于修正的Church方程,从理论上讨论了次谐波的产生与调频激励声压的关系及产生阈值,并且实验证实了优化调频信号的带宽及调频时间可以提高次谐波信号幅度及改善主瓣和旁瓣特性. 理论与实验表明,与传统脉冲信号激励相比,调频信号激励产生的次谐波幅度可提高约22dB. 关键词: 调频激励 超声造影剂 微气泡 次谐波  相似文献   

17.
The purpose of this study was to investigate the effect of parameter changes that can potentially lead to unreliable measurements in fat quantification. Chemical shift imaging was performed using spoiled gradient echo sequences with systematic variations in the following: two-dimensional/three-dimensional sequence, number of echoes, delta echo time, fractional echo factor, slice thickness, repetition time, flip angle, bandwidth, matrix size, flow compensation and field strength. Results indicated no significant (or significant but small) changes in fat fraction with parameter. The significant changes can be attributed to the known effects of T1 bias and two forms of noise bias.  相似文献   

18.
马秀荣  梁裕卿  王松  张双根  单云龙 《中国物理 B》2016,25(7):70302-070302
We investigate the intensity and efficiency of a compressed echo, which is important in arbitrary waveform generation(AWG). A new model of compressed echo is proposed based on the optical Bloch equations, which exposes much more detailed parameters than the conventional model, such as the time delay of the chirp lasers, the nature of the rare-earth-iondoped crystal, etc. According to the novel model of compressed echo, we find that reducing the time delay of the chirp lasers and scanning the lasers around the center frequency of the inhomogeneously broadened spectrum, while utilizing a crystal with larger coherence time and excitation lifetime can improve the compressed echo's intensity and efficiency. The theoretical analysis is validated by numerical simulations.  相似文献   

19.
Estimation of ultrasonic attenuation in a bone using coded excitation   总被引:3,自引:0,他引:3  
This paper describes a novel approach to estimate broadband ultrasound attenuation (BUA) in a bone structure in human in vivo using coded excitation. BUA is an accepted indicator for assessment of osteoporosis. In the tested approach a coded acoustic signal is emitted and then the received echoes are compressed into brief, high amplitude pulses making use of matched filters and correlation receivers. In this way the acoustic peak pressure amplitude probing the tissue can be markedly decreased whereas the average transmitted intensity increases proportionally to the length of the code. This paper examines the properties of three different transmission schemes, based on Barker code, chirp and Golay code. The system designed is capable of generating 16 bits complementary Golay code (CGC), linear frequency modulated (LFM) chirp and 13-bit Barker code (BC) at 0.5 and 1 MHz center frequencies. Both in vivo data acquired from healthy heel bones and in vitro data obtained from human calcaneus were examined and the comparison between the results using coded excitation and two cycles sine burst is presented. It is shown that CGC system allows the effective range of frequencies employed in the measurement of broadband acoustic energy attenuation in the trabecular bone to be doubled in comparison to the standard 0.5 MHz pulse transmission. The algorithm used to calculate the pairs of Golay sequences of the different length, which provide the temporal side-lobe cancellation is also presented. Current efforts are focused on adapting the system developed for operation in pulse-echo mode; this would allow examination and diagnosis of bones with limited access such as hip bone.  相似文献   

20.
Echo-planar imaging is widely used in functional neuroimaging but suffers from its pronounced sensitivity to field inhomogeneities that cause geometric distortions and image blurring which both limit the effective in-plane resolution achievable. In this work, it is shown how inner-field-of-view techniques based on 2D-selective RF excitations (2DRF) can be applied to reduce the field-of-view in the phase-encoding direction without aliasing and increase the in-plane resolution accordingly. Free-induction-decay (FID) EPI and echo-train-shifted (T2*-weighted) and standard (T2-weighted) spin-echo (SE) EPI with in-plane resolutions of up to 0.5×1.0 mm2 (slice thickness 5 mm) were acquired at 3 T. Unwanted signal contributions of 2DRF side excitations were shifted out of the object (FID-EPI) or of the refocusing plane by tilting the excitation plane (SE-EPI). Brain activation in healthy volunteers was investigated with checkerboard and finger-tapping block-design paradigms. Brain activation could be detected with all sequences and contrasts, most reliably with FID-EPI due to its higher signal amplitude and the longer 2DRF excitation that are more sensitive to magnetic field inhomogeneities. In conclusion, inner-FOV EPI based on 2DRF excitations could help to improve the spatial resolution of fMRI of focal target regions, e.g. for applications in the spinal cord.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号