首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a critical review of off-line and on-line coupling of matrix-assisted laser desorption/ ionization (MALDI) mass spectrometry to liquid column separations (e.g. HPLC, GPC and CE) and planar separations (e.g. PAGE and TLC). Off-line MALDI analysis of fractions collected from HPLC, GPC and CE or spots scraped and extracted from TLC and PAGE has already become a routine practice for many laboratories. MALDI has also been used to obtain mass spectra directly from TLC plates and PAGE. The direct analysis methods range from dot-blotted samples to two-dimensional scanning of the entire gels/plates. Various combinations of on-line coupling of MALDI with column separations are also reviewed. The review discusses the strengths and limitations associated with different off-line and on-line coupling approaches.  相似文献   

2.
3.
Various microfluidic devices have been developed for proteomic analyses and many of these have been designed specifically for mass spectrometry detection. In this review, we present an overview of chip fabrication, microfluidic components, and the interfacing of these devices to matrix-assisted laser desorption ionization (MALDI) mass spectrometry. These devices can be directly coupled to the mass spectrometer for on-line analysis in real-time, or samples can be analyzed on-chip or deposited onto targets for off-line readout. Several approaches for combining microfluidic devices with analytical functions such as sample cleanup, digestion, and separations with MALDI mass spectrometry are discussed.  相似文献   

4.
In this study we report an improved protocol that combines simplified sample preparation and micro-scale separation for mass spectrometric analysis of neuropeptides from individual neuroendocrine organs of crab Cancer borealis. A simple, one-step extraction method with commonly used matrix-assisted laser desorption/ionization (MALDI) matrix, 2,5-dihydroxybenzoic acid (DHB), in saturated aqueous solution, is employed for improved extraction of neuropeptides. Furthermore, a novel use of DHB as background electrolyte for capillary electrophoresis (CE) separation in the off-line coupling of CE to MALDI-Fourier transform mass spectrometric (FT-MS) detection is also explored. The new CE electrolyte exhibits full compatibility with MALDI-MS analysis of neuropeptides in that both the peptide extraction process and MALDI detection utilize DHB. In addition, enhanced resolving power and improved sensitivity are also observed for CE-MALDI-MS of peptide mixture analysis. Collectively, the use of DHB has simplified the extraction and reduced the sample loss by elimination of homogenizing, drying, and desalting processes. In the mean time, the concurrent use of DHB as CE separation buffer and subsequent MALDI matrix offers improved spectral quality by eliminating the interferences from typical CE electrolyte in MALDI detection.  相似文献   

5.
Capillary electrophoresis (CE) was coupled off-line with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the analysis of proteins and peptides. CE fractions were collected directly on a matrix-coated MALDI target, using a sheath-flow interface. Protein adsorption during CE separations was prevented by coating the capillaries with the physically adsorbed, cationic polymer PolyE-323. The CE/MALDI-MS system was used for the analysis of model proteins and peptides at physiological pH as well as analysis of proteins in tear fluid. Moreover, tryptic on-target digestion of the collected protein fractions, with subsequent MALDI-MS and MS/MS peptide analysis, was demonstrated.  相似文献   

6.
A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.  相似文献   

7.
The analysis of biological samples (e.g., blood, urine, saliva, tissue homogenates) by capillary electrophoresis (CE) requires efficient sample preparation (i.e., concentration and clean-up) procedures to remove interfering solutes (endogenous/exogenous and/or low-/high-molecular-mass), (in)organic salts and particulate matter. The sample preparation modules can be coupled with CE either off-line (manual), at-line (robotic interface), on-line (coupling via a transfer line) or in-line (complete integration between sample preparation and separation system). Sample preparation systems reported in the literature are based on chromatographic, electrophoretic or membrane-based procedures. The combination of automated sample preparation and CE is especially useful if complex samples have to be analyzed and helps to improve both selectivity and sensitivity. In this review, the different modes of solid-phase (micro-) extraction will be discussed and an overview of the potential of chromatographic, electrophoretic (e.g., isotachophoresis, sample stacking) and membrane-based procedures will be given.  相似文献   

8.
The role of separation science in proteomics research.   总被引:22,自引:0,他引:22  
H J Issaq 《Electrophoresis》2001,22(17):3629-3638
In the last few years there has been an increased effort into the separation, quantification and identification of all proteins in a cell or tissue. This is a review of the role gel electrophoresis, high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) play in proteomics research. The capabilities and limitations of each separation technique have been pointed out. Instrumental strategies for the resolution of cell proteins which are based on efficient separation employing either a single high-resolution procedure or a multidimensional approach on-line or off-line, and a mass spectrometer for protein identification have been reviewed. A comparison of the advantages of multi-dimensional separations such as two-dimensional polyacrylamide gel electrophoresis, HPLC-HPLC, and HPLC-CE to the separation of cell and tissue proteins are discussed. Also, a discussion of novel approaches to protein concentration, separation, detection, and quantification is given.  相似文献   

9.
Relationships between log k' values of polynuclear hydrocarbons and composition of water/methanol mixtures were determined for HPTLC on RP-18 silica and for HPLC using RP-2 silica. In spite of differences in the adsorbents used, a good correlation between HPLC and TLC parameters was found. In the TLC experiments, a sandwich tank with a modified solvent distributor was used. It has been reported that thin-layer chromatography is a good technique for the preliminary optimization of column chromatographic separations [1–5]. So far, the comparison of TLC and HPLC has been mainly restricted to silica as the adsorbent. Since TLC plates precoated with silanized adsorbents recently became commercially available, it seemed interesting to compare the chromatographic parameters obtained for the “reversed phase” systems with the two techniques (see also ref. 6).  相似文献   

10.
Stutz H 《Electrophoresis》2005,26(7-8):1254-1290
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.  相似文献   

11.
The soluble color pigments of raisin are separated by reversed-phase thin-layer chromatography (TLC), and the capacity of TLC-Fourier transform infrared (FTIR) with both on-line and off-line coupling is assessed for the identification of the main fraction. TLC has also been used as a pilot technique for the development of a gradient elution method for the separation of pigments by high-performance liquid chromatography (HPLC). On-line TLC-FTIR cannot be used for identification because of the strong adsorbance of the stationary phase. Off-line TLC-FTIR combined with the retention behavior of the main pigment fraction indicates that it is a polymer, caramel-like compound composed of erythrose and fructose monomers. Baseline separation of pigments is achieved by HPLC using TLC as a pilot method.  相似文献   

12.
We report the utilization of a high power UV light-emitting diode for fluorescence detection (UV-LED-IF) in CE separations. CE-UV-LED-IF allows analysis of a range of environmentally and biologically important compounds, including PAHs and biogenic amines, including neurotransmitters, amino acids, proteins, and peptides, that have been derivatized with UV-excited fluorogenic labels, e.g., o-phthalic dicarboxaldehyde/beta-mercaptoethanol (OPA/beta-ME). The 365 nm UV-LED was used as a stable, low cost source for detection of UV-excited fluorescent compounds. UV-LED-IF was used with both zonal CE separations and MEKC. Native fluorescence detection of PAHs was accomplished with detection limits ranging from 10 nM to 1.3 microM. Detection limits for OPA/beta-ME-labeled glutamic acid and aspartic acid were 11 and 10 nM, respectively, for off-line labeling, and 47 and 47 nM, respectively, for on-line labeling, comparable to UV-laser-based systems. Analysis of OPA/beta-ME-labeled proteins and peptides was performed with 28 and 47 nM detection limits for BSA and myoglobin, respectively.  相似文献   

13.
Recent developments in the coupling of highly selective separation techniques such as capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) to element-specific and molecule-specific detectors, such as inductively-coupled plasma mass spectrometry (ICP-MS) and electrospray ionization-tandem mass spectrometry (ESI-MS/MS) for the characterization and quantification of metallothioneins (MTs) are critically reviewed and discussed. This review gives an update based on the literature over the last five years. The coupling of CE to ICP-MS is especially highlighted. As a result of progress in new interface technologies for CE-ICP-MS, research topics presented in the literature are changing from "the characterization of interfaces by metallothioneins" to the "characterization of metallothioneins by CE-ICP-MS". New applications of CE-ICP-MS to the analysis of MTs in real samples are summarized. The potential of the on-line isotope dilution technique for the quantification of MTs and for the determination of the stoichiometric composition of metalloprotein complexes is discussed. Furthermore, a selection of relevant papers dealing with HPLC-ICP-MS for MT analysis are summarized and compared to those dealing with CE-ICP-MS. In particular, the use of size-exclusion (SE)-HPLC as a preliminary separation step for metallothioneins in real samples prior to further chromatographic or electrophoretic separations is considered. Additionally, the application of electrospray ionisation-tandem mass spectrometry (ESI-MS/MS) for the identification of metallothionein isoforms following electrophoretic or chromatographic separation is discussed.  相似文献   

14.
Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOF-MS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-of-flight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run.  相似文献   

15.
Low-impact ionization sources like electrospray ionization (ESI) and matrix-assisted, laser desorption/ionization (MALDI) equipped with time-of-flight (TOF) mass analyzers provide intact protein analysis over a very wide molar mass range. ESI/TOFMS provides also indications on the higher-order structure of intact proteins and non-covalent protein complexes. However, direct analysis of intact proteins mixtures in real samples shows limited success, mainly because spectra become very complex to interpret. This is also due to sample contaminants, and to the mechanism of competitive ionization in ESI or MALDI. Rapid and efficient sample clean-up and separation methods can significantly enhance the power of TOFMS for intact protein analysis. However, if protein native conditions want to be maintained, the methods should affect neither the three-dimensional structure nor the non-covalent chemistry of the proteins. Reversed-phase (RP) HPLC, size-exclusion chromatography (SEC), and capillary zone electrophoresis (CZE) are on-line or off-line coupled to ESI/TOFMS or MALDI/TOFMS. In fact, these separation methods often show limitations when applied to the analysis of native proteins. Organic modifiers and saline buffers are required in the case of RP HPLC or CZE. They can induce protein degradation or affect ionization when MS is performed after separation. High voltages used in CZE can contribute to alter proteins from their native form. In the case of high molar mass proteins, SEC is scarcely selective, and barely able to detect protein aggregates. Sample entanglement/adsorption on the stationary phase can also occur.  相似文献   

16.
Various off-line methods for clean-up and sample enrichment are available for the analysis of polycyclic aromatic hydrocarbons (PAHs) in edible oils and fats. These methods consist of laborious and time consuming procedures. This study reports an on-line method using LC-LC coupling. After clean-up of the sample on a donor-acceptor complex chromatography (DACC) column the PAHs are transferred to and separated on an analytical HPLC column. Quantification is carried out with fluorescence detection. The DACC column clean-up is fast and is carried out during the HPLC run of the previous sample. Compared to the traditional methods this automated on-line method saves considerable time and significantly reduces the amount of solvent waste. The method uses common HPLC equipment and its performance has been evaluated.  相似文献   

17.
The methodology for the detection of picogram quantities of nucleotides directly from TLC plates without the use of radioactive labeling has been developed. The method couples thin-layer chromatography (TLC) separation with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) detection. The TLC/MALDI coupling protocol was studied and optimized for the separation and detection of deoxyribonucleotides. Several ammonia based solvents were examined as potential extraction solvents for the TLC/MALDI coupling protocol. It was found that in order to obtain maximum MALDI signal intensity and minimal analyte spreading, the extraction solvent should produce Rf-values for the analytes in the range of 0.3–0.4. Rf-values above this range led to extensive analyte spreading and those below this range resulted in poor extraction. Various MALDI matrices and co-matrices were investigated, the best results were obtained using 2′,4′,6′-trihydroxyacetophenone (THA) as a matrix. The extraction solvent chosen was an ammonium hydroxide/methanol (100 mM/30%, Rf = 0.28–0.38) solvent system which was found to provide the best sensitivity, minimal lateral spreading and excellent matrix transfer. Using the optimized coupling protocol, the detection limits for the deoxyribonucleotide monophosphates were established at or better than 10 picograms. Received: 27 May 1998 / Revised: 18 June 1999 / Accepted: 22 June 1999  相似文献   

18.
A bottom-up proteomic approach, based on capillary electrophoresis (CE) in combination with matrix- assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-ToF/ToF MS), was used to analyze immunoaffinity depleted human cerebrospinal fluid (CSF) and compare it with a non-depleted sample. After enzymatic digestion and desalting, the tryptic peptides were separated by CE using PolyE-323 modified capillaries and fractionated off-line onto MALDI target plates for further analysis by MALDI-MS and MS/MS. The protein profile of the depleted sample was compared with non depleted CSF. Overall, 85 proteins were identified with 95% significance in both samples. The significance scores for proposed biomarkers, such as amyloid-like protein 1 precursor, could be increased up to 12 times after the depletion. Other proteins, often suggested to be related to neurodegenerative diseases, like amyloid beta A4 protein precursor, superoxide dismutase and apolipoprotein E precursor could only be found in the depleted CSF samples. The effect of a derivatization of tryptic peptides with 2- methoxy-4,5-dihydro-1H-imidazole reagent for protein identification with MS was also employed to increase the number of identified proteins and the sequence coverages. The results presented in this study illustrate the benefit of combining a sample pre-fractionation step and a label's ability to enhance the ionization efficiency with the potential of CE using PolyE-323 modified capillaries in the analysis of complex samples. The straight-forward approach that provides speed and simplicity resulting in high-resolution separations and low sample consumption represents an easily applicable separation technique that can serve as a complement to other currently existing analytical approaches needed in modern proteomic analysis of clinically relevant samples.  相似文献   

19.
Zhang Z  Wang J  Hui L  Li L 《Electrophoresis》2012,33(4):661-665
Herein, we report an immobilized pH gradient (IPG) capillary isoelectric focusing-matrix-assisted laser desorption/ionization mass spectrometry (CIEF-MALDI MS) platform designed for the separation of complex neuropeptides. This platform features a poly(glycidyl methacrylate-divinylbenzene) (GMA-DVB)-based monolithic column for CIEF separation. Different from regular CIEF, carrier ampholytes are preimmobilized on the monolithic surface instead of being added to the sample. An off-line coupling of IPG-CIEF to MALDI MS has been established. Comparison with regular CIEF and optimizations are performed with bovine serum albumin tryptic peptides and extracted neuropeptide mixtures from crustacean Callinectes sapidus. It has been demonstrated that the separation of complex peptide mixtures in neutral and basic pH ranges can be achieved in less than 10 min with comparable separation efficiency with regular CIEF, while the MS signal is significantly enhanced when employing IPG-CIEF. Enhanced neuropeptide detection is also observed after coupling IPG-CIEF with MALDI MS.  相似文献   

20.
Summary Packed column supercritical fluid chromatography, like HPLC, utilizes a sample loop to introduce materials onto the column for analysis. Unlike HPLC the mobile phase in SFC cannot be used to dissolve the sample. In practice, this causes a solvent peak, which can create a problem in the chromatographic interpretation. This paper describes one approach to solving this problem. A valving scheme is used to extract materials with the supercritical CO2 mobile phase and introduce them onto the column with no external handling. The viability of this method is demonstrated and separations of the CO2 extracts for several materials are shown on various columns. Comparisons are made for coal and coffee extracts using this on-line method and conventional off-line CH2Cl2 extracts. Advantages of the on-line procedure as they apply to chromatography and high information detectors are also discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号