首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel analytical approach is described that combines the preconcentration power of solvent extraction with the resolution and sensitivity of a 500 MHz 1H NMR spectroscopic detection method for the quantitative determination of metals. Co(II), Cr(VI), Ni(II) and Pb(II) in water are extracted into chloroform as dithiocarbamate complexes. By decoupling the protons and employing a solvent-induced shift method, the 1H NMR spectrum containing the dithiocarbamate complexes of Co(II), Cr(VI), Ni(II) and Pb(II) is fully resolved at CDCl3/ C6D6 below 40%/60%. The detection limits for Co(II), Cr(VI), Ni(II) and Pb(II) are estimated to be 0.12, 0.073, 0.11 and 0.27 μg/mL, respectively, in the sample solution.  相似文献   

2.
溶剂萃取原子吸收光谱法测定头蜡中铅铬镉镍钴   总被引:5,自引:0,他引:5  
用高压溶样弹将头蜡用HNO3-H2O2溶解,经0.0500mol/L 8-羟基喹啉体氯仿溶液萃取,用原子吸收光谱法测定痕量铅、铬、镉、镍和钴。方法回收率分别为99.0%、99.5%、96.0%、102%和98.5%,RSD分别为2.9%、3.0%、4.1%、3.8%和2.0%。方法可应用于出口头蜡检测。  相似文献   

3.
4.
Summary A semi-automatic microliter sample injector with an 8-way motor-driven rotary valve was constructed for a conventional pneumatic nebulizer. After a 40-l sample was injected into an injection tee with a micro-syringe, nebulization and flushing the sample pathway with water followed by argon were automatically executed. An automatic peak detector/integrator was employed in each channel of a three-channel spectrometer for simultaneous multielement analysis. The relative standard deviation of the peak height for 1g Zr/ml was 1.7% and measuring time of one sample was about 1 min. Detection limits were 2 to 6 times higher than those in continuous feeding.
Halbautomatische Injektion von Mikroliter-Proben in ein induktiv gekoppeltes Plasma zwecks simultaner Multielementanalyse
Zusammenfassung Ein halbautomatischer Injektor für Mikroliterproben mit einem motorgetriebenen 8-Weg-Ventil für ein konventionelles Vernebelungsgerät wurde konstruiert. Nachdem eine 40-l-Probe mit einer Mikroinjektionsspritze in ein Injektions-T-Stück eingeführt ist, erfolgt automatisch Vernebelung, dann Spülung des Probenweges zunächst mit Wasser, dann mit Argon. Ein automatischer Spitzen-Detektor/Integrator in jedem der drei Kanäle des Spektrometers ermöglicht die gleichzeitige Multielementanalyse. Die rel. Standardabweichung der Spitzenhöhe für 1g Zr/ml betrug 1,7%, die Zeit für die Messung einer Probe ungefähr eine Minute. Die Nachweisgrenzen sind 2- bis 6mal höher als bei kontinuierlicher Zugabe.
  相似文献   

5.
Solid-phase extraction (SPE) method for preconcentration and determination of Cd(II), Pb(II), Co(II), Ni(II), and Cu(II) aqueous samples by inductively coupled plasma optical emission spectrometry is described. The preconcentration of analytes is accomplished by retention of their chelates with 1.10-phenanthroline in aqueous solution on a solid phase containing carboxylic acid (COOH) bonded to silica gel in a column. The limits of detection values (defined as “3s” where “s” is standard deviation of the blank determination) are 3.6 μg/L for Cd(II), 17.5 μg/L for Pb(II), 3.1 μg/L for Co(II), 2.1 μg/L for Ni(II), and 4.4 μg/L for Cu(II) and corresponding limit of quantification (6s) values are 7.2, 35, 6.2, 4.2 and 8.8 μg/L, respectively. As a result, a simple method was elaborated for the group concentration and determination of the above mentioned metals in reference material and in samples of plant material. The article is published in the original.  相似文献   

6.
Da Silva JF  Martins W 《Talanta》1992,39(10):1307-1312
Single-phase solutions (1.72 x 10(-2)M in TTA) of water/ethanol/MIBK, when added to an excess of water, break down into two immiscible liquid layers and TTA complexes of Fe(III), Co(II), Ni(II), Cu(II) and PB(II) are extracted into the organic layer. Quantitative extractions were obtained for the five metals and separations of Fe(III) from a 1000-fold excess of Co(II), NI(II) or PB(II) are obtained. The reactions of the metal ions with TTA were studied in the single-phase solutions before the extraction step, giving useful information as to their complexation behavior.  相似文献   

7.
Berger SA 《Talanta》1982,29(8):718-720
Benzil mono(2-quinolyl)hydrazone, BmQH, has been studied as an extracting agent for Cu(II), Ni(II) and Co(II). Though the uncomplexed ligand remains undissociated in the pH range 3.5-10, it can lose a proton on complexation with metals, owing to the electron-withdrawing effects of neighbouring groups. The dependence of degree of extraction on pH indicates that complexes of both Cu(2+) and Cu(OH)(+) are extracted. Cu(BmQH)(2) and Cu(OH)BmQH species are extracted into MIBK, and the Cu(OH)BmQH complex is extracted into benzene. In the vicinity of pH 5.5-6, extraction efficiencies greater than 95% can be achieved with both solvents. Both Ni(II) and Co(II) also show dependence of extraction on pH, but precipitation of both metals in the vicinity of pH 6 limits further studies.  相似文献   

8.
9.
It was shown that Cr(VI), Ni(II), and Cu(II) can be simultaneously adsorbed on a solid phase consisting of two filled fibrous disks and then determined visually using organic reagents. One sorbent disk, a fibrous material filled with an AB-17 anion exchanger, was used to determine chromium by its reaction with 1,5-diphenylcarbazide. Another disk filled with an KU-2 cation exchanger was used for the simultaneous sorption of copper and nickel followed by the consecutive determination of nickel with dimethylglyoxime and copper with sodium diethyldithiocarbamate. The conditions were optimized for the determination of nickel in the presence of copper and of copper in the presence of nickel after decomposing its dimethylglyoxime complex with 1 M HCl. The detection limits were 0.02, 0.1, and 0.05 mg/L for Cr, Ni, and Cu, respectively. The time of analysis was no longer that 20 min.  相似文献   

10.
Silica gel chemically bonded with aminothioamidoanthraquinone was synthesized and characterized. The metal sorption properties of modified silica were studied towards Pb(II), Cu(II), Ni(II), Co(II) and Cd(II). The determination of metal ions was carried out on FAAS. For batch method, the optimum pH ranges for Pb(II), Cu(II) and Cd(II) extraction were ≥3 but for Ni(II) and Co(II) extraction were ≥4. The contact times to reach the equilibrium were less than 10 min. The adsorption isotherm fitted the Langmuir's model showed the maximum sorption capacities of 0.56, 0.30, 0.15, 0.12 and 0.067 mmol/g for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively. In the flow system, a column packed modified silica at 20 mg for Pb(II) and Cu(II), 50 mg for Cd(II), 60 mg for Co(II), Ni(II) was studied at a flow rate of 4 and 2.5 mL/min for Ni(II). The sorbed metals were quantitatively eluted by 1% HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl and SO42− at 10, 100 and 1000 mg/L was observed. The application of this modified silica gel to preconcentration of pond water, tap water and drinking water gave high accuracy and precision (%R.S.D. ≤ 9). The method detection limits were 22.5, 1.0, 2.9, 0.95, 1.1 μg/L for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively.  相似文献   

11.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

12.
Newly synthesized 2-propylpiperidine-1-carbodithioate (2-PPC) was used for the extraction of Cr(III), Ni(II), and Zn(II) from various water samples. In the present investigation, the use of a syringe loaded with sorbent for the separation and enrichment of Cr(III), Ni(II), and Zn(II) prior to their determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES) was proposed to substitute the batch and column techniques. The described method was compared with the column technique with respect to fastness, simplicity, recovery, and risk of contamination. The syringe was loaded with 1.0 g of sorbent in order to retain the analyte elements. Next, 7.0 mL of sample solution (pH 5.0 ± 0.2) was drawn into the syringe in 15 s and discharged over 15 s. Then, an eluent (3.0 M HCl) was drawn into the syringe and ejected back to desorb the analyte elements. At the optimum conditions, the percentage recoveries of Cr(III), Ni(II), and Zn(II) were in the range of 94.50 to 99.62% with a standard deviation (S.D.) of 0.03%. The elements could be concentrated by drawing and discharging several portions of sample successively and eluting only one time. The detailed study of various interferences proved the method to be highly selective. The risk of contamination is less than that with the column technique. The method was successfully applied to the determination of Cr(III), Ni(II), and Zn(II) in spiked and natural water samples. The results obtained are in good agreement with those obtained by the reported methods at the 95% confidence level. The text was submitted by the authors in English.  相似文献   

13.
The present work investigates the influence of acid activation of montmorillonite on adsorption of Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) from aqueous medium and comparison of the adsorption capacities with those on parent montmorillonite. The clay-metal interactions were studied under different conditions of pH, concentration of metal ions, amount of clay, interaction time, and temperature. The interactions were dependent on pH and the uptake was controlled by the amount of clay and the initial concentration of the metal ions. The adsorption capacity of acid-activated montmorillonite increases for all the metal ions. The interactions were adsorptive in nature and relatively fast and the rate processes more akin to the second-order kinetics. The adsorption data fitted both Langmuir and Freundlich isotherms, indicating that strong forces were responsible for the interactions at energetically nonuniform sites. The Langmuir monolayer capacity of the acid-activated montmorillonite is more than that of the parent montmorillonite (Cd(II): 32.7 and 33.2 mg/g; Co(II): 28.6 and 29.7 mg/g; Cu(II): 31.8 and 32.3 mg/g; Pb(II): 33.0 and 34.0 mg/g; and Ni(II): 28.4 and 29.5 mg/g for montmorillonite and acid-activated montmorillonite, respectively). The thermodynamics of the rate processes showed the adsorption of Co(II), Pb(II), and Ni(II) to be exothermic, accompanied by decreases in entropy and Gibbs free energy, while the adsorption of Cd(II) and Cu(II) was endothermic, with an increase in entropy and an appreciable decrease in Gibbs free energy. The results have established the potential use for montmorillonite and its acid-activated form as adsorbents for Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) ions from aqueous media.  相似文献   

14.
A partial least squares (PLS-1) calibration model based on kinetic—spectrophotometric measurement, for the simultaneous determination of Cu(II), Ni(II) and Co(II) ions is described. The method was based on the difference in the rate of the reaction between Co(II), Ni(II) and Cu(II) ions with 1-(2-pyridylazo)2-naphthol in a pH 5.8 buffer solution and in micellar media at 25°C. The absorption kinetic profiles of the solutions were monitored by measuring the absorbance at 570 nm at 2 s intervals during the time range of 0–10 min after initiation of the reaction. The experimental calibration matrix for the partial least squares (PLS-1) model was designed with 30 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.1-2 μg mL−1 for each cation. The proposed method was successfully applied to the simultaneous determination of Cu(II), Ni(II) and Co(II) ions in water and in synthetic alloy samples.   相似文献   

15.
Paper electrophoresis has been used for uranium(VI) separation from Fe(II), Co(II), Ni(II) and Cu(II). The background electrolyte (0.1M HNO3-NaNO3) at different pH values contains diethyldithiophosphoric acid as complexing agent. A plot of mobility versus pH is used to obtain information on the formation of dithiophosphate complexes and to compute the stability constant of an uranyldiethyldithiophosphate complex.  相似文献   

16.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

17.
18.
The complexes formed between IE11 and Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) were identified and confirmed by IR, UV and pH-metric titration. The uptake behavior of porous silica modified with N-propylsalicylaldimine (IE11) and these metal ions were studied. Log k(d) was found to be within the range 2.19-5.16 depending on pH and time of stirring. IE11 was used in the separation and preconcentration of Cd(II), Cr(III, VI), Cu(II), Mn(II, VII) and Pb(II) from some natural water samples. Data were compared with those obtained by the solvent extraction method APDC/MIBK. The proposed methodology allows to verify an improvement in the water quality of Nile River probably attributed to high to moderate floods in the last few years. The method was found to be accurate and not subject to random error, i.e. precise.  相似文献   

19.
Total dissolved and labile concentrations of Cd(II), Cu(II), Ni(II) and Pb(II) were determined at six locations of the Bourgas Gulf of the Bulgarian Black Sea coast. Solid phase extraction procedure based on monodisperse, submicrometer silica spheres modified with 3-aminopropyltrimethoxysilane followed by the electrothermal atomic absorption spectrometry (ETAAS) was developed and applied to quantify the total dissolved metal concentrations in sea water. Quantitative sorption of Cd, Cu, Ni and Pb was achieved in the pH range 7.5–8, for 30?min, adsorbed elements were easily eluted with 2?mL 2?mol?L?1 HNO3. Since the optimal pH for quantitative sorption coincides with typical pH of Black Sea water (7.9–8.2), on-site pre-concentration of the analytes without any additional treatment was possible. Detection limits achieved for total dissolved metal quantification were: Cd 0.002?µg?L?1, Cu 0.005?µg?L?1, Ni 0.03?µg?L?1, Pb 0.02?µg?L?1 and relative standard deviations varied from 5–13% for all studied elements (for typical Cd, Cu, Ni and Pb concentrations in Black Sea water). Open pore diffusive gradients in thin films (DGT) technique was employed for in-situ sampling and pre-concentration of the sea water and in combination with ETAAS was used to determine the proportion of dynamic (mobile and kinetically labile) species of Cd(II), Cu(II), Ni(II) and Pb(II) in the sea water. Obtained results showed strong complexation for Cu and Pb with sea water dissolved organic matter. The ratios between DGT-labile and total dissolved concentrations found for Cu(II) and Pb(II) were in the range 0.2–0.4. For Cd and Ni, these ratios varied from 0.6 to 0.8, suggesting higher degree of free and kinetically labile species of these metals in sea water.  相似文献   

20.
A method for heavy metal monitoring using spectrophotometric detection is presented. Traces of Cu(II), Pb(II) and Cd(II) at the low microg l(-1) level can be determined simultaneously after both selective removal of metal interferences and preconcentration using 'extraction chromatographic resins'. Lewatit TP807'84, which contains di(2,4,4-trimethylpentyl)phosphinic acid as active component, was used as solid adsorbent. Two minicolumns containing this resin were used: one at pH 3.2 for the removal of interferences, such as Zn(II) and Fe(III), and the other at pH 5.5 for the selective preconcentration of the target analytes. Spectrophotometric determination used FIA methodology with sulfarsazene as chromogenic reagent and partial least-squares multivariate calibration. The method was successfully applied to the analysis of surface waters from the Llobregat river and ground water samples from wells in the Guadiamar basin. Accuracy, expressed in terms of recoveries, was in the range 80-120% and relative standard deviations were below 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号