首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
数据平滑和扫描步长是两个重要求导条件。本工作用五点三次多项式平滑技术对扫描数据进行平滑处理以消除随机噪音,但平滑次数增大会导致信号失真从而使导数光谱的分辨能力降低。扫描步长减小能提高导数光谱的分辨能力,但同时导致导数光谱灵敏度减小。导数光谱中干扰物等效浓度IEC的大小是上述因素的综合反映。本文以IEC为考察指标,讨论了平滑次数和扫描步长的优化。  相似文献   

2.
The most accurate method for the analysis of complex gamma ray spectra from scintillation detectors is least squares method. The major requirement of this method is individual standard spectra of all nuclides expected in the complex spectrum which is not possible and feasible for some nuclides. In the present work, an approach of using simulated standard spectrum of the radionuclides for the least squares analysis is studied. The paper describes the methodology used for the generation of simulated spectrum which is the main objective, and validation of results using standard sources in the Sodium Iodide (NaI(Tl)) based gamma ray spectrometer.  相似文献   

3.
The problem of gamma ray spectrum analysis has been is studied. The difficulties encountered by different methods are explained. An empirical method which uses an experimental peak for the analysis of spectrum is developed. This method utilizes the simple algorithm of linear least squares and is able to analyze the multiplets. It gives more accurate results than other ones. It is well adapted for automatic treatment of gamma ray spectra by small computers.  相似文献   

4.
A novel method for the quantitative evaluation of Auger electron spectra based on peak areas is presented. Sample and reference spectra in integral mode are filtered by an area conserving digital filter. This transforms the peak shapes influenced by chemical effects into standard peak shapes. After filtering a linear combination of reference spectra, differentiated spectra accounting for peak shifts and some low order polynomials to account for variations in the background is fitted to the sample spectrum by a least squares method. The need to approximate the spectrum of the secondary electron background explicitly for direct calculation of peak areas is thus eliminated. Filters of different widths are applied to reduce errors by chemical effects. The composition of the sample is computed from the composition of the reference samples and the coefficients obtained from the fit.To demonstrate the validity of this technique it has been applied to both, Gaussian model peaks and spectra of titanium carbonitrides. A further test on an alloy series is under investigation. The results show that the method works as predicted and gives accurate quantification.  相似文献   

5.
Liu B  Fan X  Huo S  Zhou L  Wang J  Zhang H  Hu M  Zhu J 《色谱》2011,29(12):1194-1198
基于二极管阵列检测器获得的色谱-光谱数据,建立了一种二元不完全重叠液相色谱峰的解析方法: 色谱数据经过去噪、归一化处理后,计算各时间点的光谱差异并进行系统聚类分析,提取特征光谱后,利用非负最小二乘法对色谱-光谱矩阵进行解析,得到基于特征光谱的流出曲线,进而得到分离后的色谱峰。将解析结果和纯标样的色谱峰进行比较,解析后的光谱图和纯标样的光谱图无显著差异,保留时间相差小于0.01 min。实验结果表明,该方法在二元不完全重叠液相色谱峰的解析方面能取得良好的效果。  相似文献   

6.
This paper describes the results of a comparison of four peak functions in describing real chromatographic peaks. They are the empirically transformed Gaussian, polynomial modified Gaussian, generalized exponentially modified Gaussian and hybrid function of Gaussian and truncated exponential functions. Real chromatographic peaks of different shapes (fronting. symmetric, and tailing) are obtained by various separation conditions of reversed-phase liquid chromatography. They are then fitted to the peak functions via the Marquardt-Levenberg algorithm, a nonlinear least-squares curve-fitting procedure, by Microsoft Solver. The qualities of the fits are evaluated by the sum of the squares of the residuals. It is concluded in the study that the empirically transformed Gaussian function offers the highest flexibility (best fits) to all shapes of chromatographic peaks, including extremely asymmetric tailing peaks with a peak asymmetry of up to 8. The flexibility of this function should improve our ability to process chromatographic peaks such as deconvolution of overlapped peaks and smoothing noisy peaks for the determination of statistical moments.  相似文献   

7.
The second-derivative spectra of absorption curves simulated by a Gaussian function were obtained by using Savitzky—Golay cubic (CPC) and quintic polynomial convolutions (QPC), based on 17 points assumed to be at 0.25-nm intervals. For data obtained directly from the simulated curves (real-type data), the second derivatives agreed with the true values if the widths at half height of the peaks were > 15 nm for CPC and 5 nm for QPC. But when integer values obtained from the real-type data were used to simulate a 12-bit A/D conversion, considerable noise appeared on the second-derivative spectra of peaks wider than the above values, obtained by both CPC and QPC. This occurred because the rounding errors introduced by the A/D conversion formed small shoulders on the digitally reproduced absorption curves, which were enhanced by the differentiation to generate noise. The noise was more intense in QPC than in CPC, thus CPC is preferable for peaks that are not very narrow.  相似文献   

8.
本底会对光谱分析结果产生很大的干扰作用,为获取特征峰的有效信息,必须首先去除本底。该文提出了一种基于小波变换的本底扣除算法,通过对光谱及后续光谱迭代进行小波变换,利用逼近系数估计本底,直到本底收敛。提出了判断多次估计的本底最大误差是否足够小的收敛准则。利用该算法去除本底后,即可进行特征峰信息的提取。分别利用仿真光谱和实验能量色散X射线荧光光谱对算法进行了验证,并与传统小波变换和多项式拟合法进行了对比。结果表明,该算法能够更准确扣除光谱本底,对其他光谱的本底扣除也具有借鉴意义。  相似文献   

9.
A method for semi-automatic background estimation in energy-dispersive x-ray fluorescence spectra is outlined. Two cubic splines were investigated and the spline called the Butland interpolant was chosen for further investigation. Prior to the calculation of the spline, peak regions are set up, and suitable knots are defined outside the peak regions. To set up the peak regions, an automatic peak-search routine and a calibration equation are used. For a given peak, the latter relates the full width at half maximum (FWHM) to the peak centre. In turn, the size of the peak regions are defined by the FWHM multiplied by a constant given by the user. The method was tested on several types of spectra. It was found that the optimal size of the peak region decreased with increasing peak density. Reproducibility tests showed that the standard deviation of the summation of counts within a peak region and after background subtraction was less than would be expected from the counting statistics.  相似文献   

10.
Although high resolution gamma ray spectrometry serves as the primary analytical technique in emergency response situations, chances for laboratories to practice analysing the type of spectra that may be expected in the early phase of such a situation are limited. This problem is more acute for laboratories in countries that have no nuclear facilities. The analysis of synthetically generated spectra may serve as a useful surrogate for actual spectra; this paper reports the results of a multilateral intercomparison exercise conducted using such a spectrum. Results indicate that the laboratories involved appear to have no problems identifying radioactive isotopes that regularly appear in national and international intercomparisons or exercises. However, some problems are evident for isotopes that are less often encountered which may, however, occur during the early phases of a nuclear accident. Isotopes prone to true coincidence summation proved also to be difficult with regard to correction of activities in some cases. The synthesized spectrum constituted a useful means of comparative analysis of complex spectra multilaterally without the impracticalities of using a sample drawn from a reactor.  相似文献   

11.
单晶硅表面周期性微结构的减反射特性及光伏特性   总被引:1,自引:0,他引:1  
利用聚苯乙烯胶体球自组装技术和纳米压印技术在单晶硅表面构筑了两种周期性微结构. 反射光谱表明, 两种周期性微结构都能够对特定波长的入射光有一定的减反射效果; 表面光电压谱和吸收光谱相对应, 在具有减反射效果的波长范围内观察到了表面光电压增强的现象, 说明这种表面构筑微结构的技术可以有效地利用在单晶硅太阳能电池的制造和设计上, 从而提高单晶硅太阳能电池的光电转换效率. 对这种周期性微结构的减反射机理进行了初步探讨.  相似文献   

12.
《印度化学会志》2023,100(1):100848
This research investigated the influence of temperature variation on the properties of ytterbium-doped cobalt Selenide (Yb-CoSe) nanostructures synthesized via the electrodeposition technique. The structural, optical, morphological, and elemental features of the synthesized films were investigated through X-ray diffractometry (XRD), ultraviolet–visible (UV–vis) spectroscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX) respectively. XRD results showed prominent peaks with a cubic phase. Good absorbance values in the visible region and reduced band gap energies upon the introduction of ytterbium were obtained from the optical analysis. Morphological results gave nanoclusters of varying sizes spread throughout the substrate surface. The elemental constituents of the deposited films were evident from the EDX spectra. The synthesized films have significant potential to be used in solar cells and optical devices.  相似文献   

13.
The new results obtained during the last two years are presented against a background of the previous development of the method (first version). The effect of the resolution enhancement filters containing non-recursive smoothing on the wide peaks, advantages of recursive technique and the construction of nonlinear baseline under multiplet to be resolved according to the GUNNINK and NIDAY method are reported in this paper.  相似文献   

14.
The influence of partial peak width integration on the statistical error has been investigated. It has been shown that integration of the central photopeak part —±(0.55–0.64) FWHM for narrow peaks and ±(0.50–0.53) FWHM for wide peaks-allows to decrease the statistical error 1.5–2.0 times in comparision with the TPA method. The results obtained are valid both for real photopeaks and for smoothed spectra. The theoretical results have been confirmed by experimental data.  相似文献   

15.
Conventional X‐ray photoelectron spectroscopy (XPS) and synchrotron‐based X‐ray photoelectron spectroscopy (HRXPS) have been used to study Iceland spar calcite (CaCO3) and dolomite (CaMg(CO3)2). The obtained full widths at half maximum (FWHMs) are mostly narrower than in the previous results, which together with the symmetry of the fitted peaks indicate effective neutralisation of surface charging. Some previously unidentified features observed in the Ca 2p, C 1s and O 1s spectra of calcite have been suggested to be bulk plasmons. Also, surface core level shifts in Ca 2p (in calcite) and Mg 2p (in dolomite) spectra have been obtained and found to be consistent between XPS and HRXPS measurements. A peak attributed to carbide (CaC2) has been suggested to indicate beam‐assisted interaction with hydrocarbons found on the surface. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Three different methods to determine the oxide‐phase concentration in mixed cerium oxide by hard X‐ray photoelectron spectroscopy are applied and quantitatively compared. Synchrotron‐based characterization of the O 1s region was used as a benchmark to introduce a method based on the weighted superposition of the Ce 3d spectra of the pure Ce3+ and Ce4+ phases, which was shown to lead to reliable and highly accurate determination of the mean oxidation state in mixed cerium oxides. The results obtained reveal a linear relation between the third distinct final state (u′′′) satellite peak intensity of the Ce4+ phase and the Ce4+ concentration by proper inclusion of Ce3+‐related plasmon satellite peaks, which contradicts previous claims of nonlinear behavior. In contrast, quantitative conventional peak‐fitting procedures were shown to be well suited for the Ce 2p region due to its relatively simple structure. Additional satellite features observed in the Ce 3d spectrum of CeO2 were proposed to originate from plasmon contributions.  相似文献   

17.
Energy dispersive X-ray fluorescence studies on determination of thorium (in the range of 7 to 137 mg/mL) in phosphoric acid solutions obtained by dissolution of thoria in autoclave were made. Fixed amounts of Y internal standard solutions, after dilution with equal amount of phosphoric acid, were added to the calibration as well as sample solutions. Solution aliquots of approximately 2–5 µL were deposited on thick absorbent sheets to absorb the solutions and the sheets were presented for energy dispersive X-ray fluorescence measurements. A calibration plot was made between intensity ratios (Th Lα/Y Kα) against respective amounts of thorium in the calibration solutions. Thorium amounts in phosphoric acid samples were determined using their energy dispersive X-ray fluorescence spectra and the above calibration plot. The energy dispersive X-ray fluorescence results, thus obtained, were compared with the corresponding gamma ray spectrometry results and were found to be within average deviation of 2.6% from the respective gamma ray spectrometry values. The average precision obtained in energy dispersive X-ray fluorescence determinations was found to be 4% (1σ). The energy dispersive X-ray fluorescence method has an advantage over gamma ray spectrometry for thorium determination as the amount of sample required and measurement time is far less compared to that required in gamma ray spectrometry.  相似文献   

18.

For selecting gamma ray detector to determining element content using prompt gamma neutron activation analysis technique, the response of BGO and LaBr3 scintillator detectors was compared with Monte Carlo simulation method. The simulation models under different formation composed of various elements were established by MCNP, and then gamma ray spectrum was processed by least squares method. It is concluded that the element calculation accuracy will be different when scintillator was changed. With higher energy resolution, LaBr3 scintillator can be used to improve the accuracy of the element content calculation result, and is more suitable for plentiful element formation.

  相似文献   

19.
贾梦涵  回朝妍  张辉  高宇  佟美琪  马仡男 《色谱》2021,39(6):670-677
谱峰的检测分析在色谱技术研究中具有十分重要的作用,但在色谱数据采集、传输的过程中,不同程度的噪声干扰给谱峰检测带来了极大的困难.目前传统的谱峰检测算法普遍通过基底扣除的方式对谱峰的形态进行预定义,将谱峰分为单峰、重叠峰等多个种类.针对不同种类的谱峰采用不同的检测方法,这就导致了传统的谱峰检测算法具有高复杂度、低自动化程...  相似文献   

20.
Structures consisting of several peaks were clearly observed in the loss band regions of core electron peaks in the X-ray photoelectron spectra of KF, NaF and LiF. It is shown that, although these structures very much resemble the electron energy loss spectra of the salts obtained using an externally produced electron beam, the energies and intensities of some peaks are dependent upon the ionizing core levels. One peak definitely attributable to an intrinsic satellite was found in the loss band region of F 1s spectrum of each salt, which was concluded to be due to the shake-up process associated with F 2p → F 3p excitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号