1.
Han S  Yang K  Shin Y  Lee JS  Kamm RD  Chung S  Cho SW 《Lab on a chip》2012,12(13):2305-2308
Here, we report a unique method to quantify the effects of in vivo-like extracellular matrix (ECM) for guiding differentiation of neural stem cells (NSCs) in three-dimensional (3D) microenvironments using quantitative real-time polymerase chain reaction (qRT-PCR). We successfully monitored and quantified differentiation of NSCs in small volume ECMs and found that differentiation of NSCs, especially those differentiating towards neuronal and oligodendrocytic lineages, is significantly enhanced by 3D microenvironments reconstituted in the microfluidic channels.  相似文献   

2.
Lee JM  Kim JE  Kang E  Lee SH  Chung BG 《Electrophoresis》2011,32(22):3133-3137
We developed an integrated microfluidic culture device to regulate embryonic stem (ES) cell fate. The integrated microfluidic culture device consists of an air control channel and a fluidic channel with 4×4 micropillar arrays. We hypothesized that the microscale posts within the micropillar arrays would enable the control of uniform cell docking and shear stress profiles. We demonstrated that ES cells cultured for 6 days in the integrated microfluidic culture device differentiated into endothelial cells. Therefore, our integrated microfluidic culture device is a potentially powerful tool for directing ES cell fate.  相似文献   

3.
Let it grow: The conjugated polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was synthesized with heparin as the counterion to form a cell culture substrate. The surface of PEDOT:heparin in the neutral state associated biologically active growth factors. Electrochemical in?situ oxidation of PEDOT during live cell culture decreased the bioavailability of the growth factor and created an exact onset of neural stem cell differentiation.  相似文献   

4.
There is great interest in genetic modification of bone marrow-derived mesenchymal stem cells (MSC), not only for research purposes but also for use in (autologous) patient-derived-patient-used transplantations. A major drawback of bulk methods for genetic modifications of (stem) cells, like bulk-electroporation, is its limited yield of DNA transfection (typically then 10%). This is even more limited when cells are present at very low numbers, as is the case for stem cells. Here we present an alternative technology to transfect cells with high efficiency (>75%), based on single cell electroporation in a microfluidic device. In a first experiment we show that we can successfully transport propidium iodide (PI) into single mouse myoblastic C2C12 cells. Subsequently, we show the use of this microfluidic device to perform successful electroporation of single mouse myoblastic C2C12 cells and single human MSC with vector DNA encoding a green fluorescent-erk1 fusion protein (EGFP-ERK1 (MAPK3)). Finally, we performed electroporation in combination with live imaging of protein expression and dynamics in response to extracellular stimuli, by fibroblast growth factor (FGF-2). We observed nuclear translocation of EGFP-ERK1 in both cell types within 15 min after FGF-2 stimulation. Due to the successful and promising results, we predict that microfluidic devices can be used for highly efficient small-scale 'genetic modification' of cells, and biological experimentation, offering possibilities to study cellular processes at the single cell level. Future applications might be small-scale production of cells for therapeutic application under controlled conditions.  相似文献   

5.
Endothelial cell polarization and chemotaxis in a microfluidic device   总被引:2,自引:0,他引:2  
Shamloo A  Ma N  Poo MM  Sohn LL  Heilshorn SC 《Lab on a chip》2008,8(8):1292-1299
The directed migration of endothelial cells is an early and critical step in angiogenesis, or new blood vessel formation. In this study, the polarization and chemotaxis of human umbilical vein endothelial cells (HUVEC) in response to quantified gradients of vascular endothelial growth factor (VEGF) were examined. To accomplish this, a microfluidic device was designed and fabricated to generate stable concentration gradients of biomolecules in a cell culture chamber while minimizing the fluid shear stress experienced by the cells. Finite element simulation of the device geometry produced excellent agreement with the observed VEGF concentration distribution, which was found to be stable across multiple hours. This device is expected to have wide applicability in the study of shear-sensitive cells such as HUVEC and non-adherent cell types as well as in the study of migration through three-dimensional matrices. HUVEC were observed to chemotax towards higher VEGF concentrations across the entire range of concentrations studied (18-32 ng mL(-1)) when the concentration gradient was 14 ng mL(-1) mm(-1). In contrast, shallow gradients (2 ng mL(-1) mm(-1)) across the same concentration range were unable to induce HUVEC chemotaxis. Furthermore, while all HUVEC exposed to elevated VEGF levels (both in steep and shallow gradients) displayed an increased number of filopodia, only chemotaxing HUVEC displayed an asymmetric distribution of filopodia, with enhanced numbers of protrusions present along the leading edge. These results suggest a two-part requirement to induce VEGF chemotaxis: the VEGF absolute concentration enhances the total number of filopodia extended while the VEGF gradient steepness induces filopodia localization, cell polarization, and subsequent directed migration.  相似文献   

6.
Lin F  Butcher EC 《Lab on a chip》2006,6(11):1462-1469
This paper describes the use of a simple microfluidic device for studying T cell chemotaxis. The microfluidic device is fabricated in poly(dimethylsiloxane) (PDMS) using soft-lithography and consists of a "Y" type fluidic channel. Solutions are infused into the device by syringe pumps and generate a concentration gradient in the channel by diffusion. We show that the experimentally measured gradient profiles agree nicely with theoretical predictions and the gradient is stable in the observation region for cell migration. Using this device, we demonstrate robust chemotaxis of human T cells in response to single and competing gradients of chemokine CCL19 and CXCL12. Because of the simplicity of the device, it can flexibly control gradient generation in space and time, and would allow generation of multiple gradient conditions in a single chip for highly parallel chemotaxis experimentation. Visualization of T cell chemotaxis has previously been limited to studies in 3D matrices or under agarose assays, which do not allow precise control or variation in conditions. Acknowledging the importance of lymphocyte homing in the adaptive immune response, the ability to study T cell chemotaxis in microfluidic devices offers a new approach for investigating lymphocyte migration and chemotaxis in vitro.  相似文献   

7.
Culturing stem cells as free-floating aggregates in suspension facilitates large-scale production of cells in closed systems, for clinical use. To comply with GMP standards, the use of substances such as proteolytic enzymes should be avoided. Instead of enzymatic dissociation, the growing cell aggregates may be mechanically cut at passage, but available methods are not compatible with large-scale cell production and hence translation into the clinic becomes a severe bottle-neck. We have developed the Biogrid device, which consists of an array of micrometerscale knife edges, micro-fabricated in silicon, and a manifold in which the microgrid is placed across the central fluid channel. By connecting one side of the Biogrid to a syringe or a pump and the other side to the cell culture, the culture medium with suspended cell aggregates can be aspirated, forcing the aggregates through the microgrid, and ejected back to the cell culture container. Large aggregates are thereby dissociated into smaller fragments while small aggregates pass through the microgrid unaffected. As proof-of-concept, we demonstrate that the Biogrid device can be successfully used for repeated passage of human neural stem/progenitor cells cultured as so-called neurospheres, as well as for passage of suspension cultures of human embryonic stem cells. We also show that human neural stem/progenitor cells tolerate transient pressure changes far exceeding those that will occur in a fluidic system incorporating the Biogrid microgrids. Thus, by using the Biogrid device it is possible to mechanically passage large quantities of cells in suspension cultures in closed fluidic systems, without the use of proteolytic enzymes.  相似文献   

8.
We present a prototype microfluidic device developed for the continuous dielectrophoretic (DEP) fractionation and purification of sample suspensions of biological cells. The device integrates three fully functional and distinct units consisting of an injector, a fractionation region, and two outlets. In the sheath and sample injection ports, the cell sample are hydrodynamically focused into a stream of controlled width; in the DEP fractionation region, a specially shaped nonuniform (isomotive) electric field is synthesized and employed to facilitate the separation, and the sorted cells are then delivered to two sample collection ports. The microfluidic behavior of the injector region was simulated and then experimentally verified. The operation and performance of the device was evaluated using yeast cells as model biological particles. Issues relating to the fabrication and operation of the device are discussed in detail. Such a device takes a significant step towards an integrated lab-on-a-chip device, which could interface/integrate to a number of other on-chip components for the device to undertake the whole laboratory procedure.  相似文献   

9.
Stem-cell-based neural regeneration has received significant attention, as it has potential to restore functionality to diseased or damaged neural tissues that have a limited ability to self-repair or regenerate. Culturing neural stem cells (NSCs) on hydrogel substrates has been shown to facilitate differentiation to neural progenitors, but this has only been achieved on very soft hydrogels, greatly increasing the difficulty of manufacture and limiting their wide applications. Here, we realized the differentiation of NSCs to neural and glial progenitors on high-strength hydrogels. Hydrogen-bonding-strengthened conductive hydrogels (PVV-PANI) were synthesized through one-pot copolymerization of 2-vinyl-4,6-diamino-1,3,5-triazine, 1-vinylimidazole and polyethylene glycol diacrylate, followed by post-coating with polyaniline (PANI). Diaminotriazine-diaminotriazine hydrogen bonding dramatically increases their mechanical strength, while copolymerization with VI pronouncedly promotes the adsorption of PANI particles, endowing the hydrogels with electrical conductivity. These hydrogels exhibit tensile strengths up to 1.16 MPa, a 559% breaking strain, a 9.9 MPa compressive strength and up to 16.7 mS/cm conductivity. Importantly, PVV-PANI hydrogels support the attachment, proliferation, and differentiation of NSCs, and allow the efficient induction of neural and glial differentiation via electrical stimulation. This work demonstrates high-strength conductive hydrogels can serve as an electroactive soft-wet platform for modulating the specific differentiation of NSCs, a significant step towards cell-based therapies for neurological diseases.  相似文献   

10.
We demonstrate a micro-electroporation device for cell lysis prior to subcellular analysis. Simple circuit models show that electrical lysis method is advantageous because it is selective towards plasma membrane while leaving organelle membrane undamaged. In addition, miniaturization of this concept leads to negligible heat generation and bubble formation. The designed microdevices were fabricated using a combination of photolithography, metal-film deposition, and electroplating. We demonstrate the electro-lysis of human carcinoma cells in these devices to release the subcellular materials.  相似文献   

11.
Hu N  Yang J  Yin ZQ  Ai Y  Qian S  Svir IB  Xia B  Yan JW  Hou WS  Zheng XL 《Electrophoresis》2011,32(18):2488-2495
A high-throughput cell electrofusion microfluidic chip has been designed, fabricated on a silicon-on-insulator wafer and tested for in vitro cell fusion under a low applied voltage. The developed chip consists of six individual straight microchannels with a 40-μm thickness conductive highly doped Si layer as the microchannel wall. In each microchannel, there are 75 pairs of counter protruding microelectrodes, between which the cell electrofusion is performed. The entire highly doped Si layer is covered by a 2-μm thickness aluminum film to maintain a consistent electric field between different protruding microelectrode pairs. A 150-nm thickness SiO? film is subsequently deposited on the top face of each protruding microelectrode for better biocompatibility. Owing to the short distance between two counter protruding microelectrodes, a high electric field can be generated for cell electrofusion with a low voltage imposed across the electrodes. Both mammalian cells and plant protoplasts were used to test the cell electrofusion. About 42-68% cells were aligned to form cell-cell pairs by the dielectrophoretic force. After cell alignment, cell pairs were fused to form hybrid cells under the control of cell electroporation and electrofusion signals. The averaged fusion efficiency in the paired cells is above 40% (the highest was about 60%), which is much higher than the traditional polyethylene glycol method (<5%) and traditional electrofusion methods (~12%). An individual cell electrofusion process could be completed within 10 min, indicating a capability of high throughput.  相似文献   

12.
High-throughput rheology in a microfluidic device   总被引:2,自引:0,他引:2  
Schultz KM  Furst EM 《Lab on a chip》2011,11(22):3802-3809
High-throughput rheological measurements in a microfluidic device are demonstrated. A series of microrheology samples are generated as droplets in an immiscible spacer fluid using a microfluidic T-junction. The compositions of the sample droplets are continuously varied over a wide range. Rheology measurements are made in each droplet using multiple particle tracking microrheology. We review critical design and operating parameters, including the droplet size, flow rates and rapid fabrication methods. Validation experiments are performed by measuring the solution viscosity of glycerine and the biopolymer heparin as a function of concentration. Overall, the combination of microrheology with microfluidics maximizes the number of rheological measurements while simultaneously minimizing the sample preparation time and amount of material, and should be particularly suited to the characterization of scarce or expensive materials.  相似文献   

13.
Stop-flow lithography in a microfluidic device   总被引:1,自引:0,他引:1  
Polymeric particles in custom designed geometries and with tunable chemical anisotropy are expected to enable a variety of new technologies in diverse areas such as photonics, diagnostics and functional materials. We present a simple, high throughput and high resolution microfluidic method to synthesize such polymeric particles. Building off earlier work that we have done on continuous flow lithography (CFL) (D. Dendukuri, D. C. Pregibon, J. Collins, T. A. Hatton, P. S. Doyle, Nat. Mater., 2006, 5, 365-369; ref. 1), we have devised and implemented a new setup that uses compressed air driven flows in preference to syringe pumps to synthesize particles using a technique that we call stop-flow lithography (SFL). A flowing stream of oligomer is stopped before polymerizing an array of particles into it, providing for much improved resolution over particles synthesized in flow. The formed particles are then flushed out at high flow rates before the cycle of stop-polymerize-flow is repeated. The high flow rates enable orders-of-magnitude improvements in particle throughput over CFL. However, the deformation of the PDMS elastomer due to the imposed pressure restricts how quickly the flow can be stopped before each polymerization event. We have developed a simple model that captures the dependence of the time required to stop the flow on geometric parameters such as the height, length and width of the microchannel, as well as on the externally imposed pressure. Further, we show that SFL proves to be superior to CFL even for the synthesis of chemically anisotropic particles with sharp interfaces between distinct sections.  相似文献   

14.
Hargis AD  Alarie JP  Ramsey JM 《Electrophoresis》2011,32(22):3172-3179
A microfluidic device capable of rapidly analyzing cells in a high-throughput manner using electrical cell lysis is further characterized. In the experiments performed, cell lysis events were studied using an electron multiplying charge coupled device camera with high frame rate (>100 fps) data collection. It was found that, with this microfluidic design, the path that a cell follows through the electric field affects the amount of lysate injected into the analysis channel. Elimination of variable flow paths through the electric field was achieved by coating the analysis channel with a polyamine compound to reverse the electroosmotic flow (EOF). EOF reversal forced the cells to take the same path through the electric field. The improved control of the cell trajectory will reduce device-imposed bias on the analysis and maximizes the amount of lysate injected into the analysis channel for each cell, resulting in improved analyte detection capabilities.  相似文献   

15.
Automated cell culture in high density tubeless microfluidic device arrays   总被引:1,自引:0,他引:1  
Microfluidics is poised to have an impact on life sciences research. However, current microfluidic methods are not compatible with existing laboratory liquid dispensing and detection infrastructure. This incompatibility is a barrier to adoption of microfluidic systems and calls for improved approaches that will enhance performance and promote acceptance of microfluidic systems in the life sciences. Ease of use, standardized interfaces and automation remain critical challenges. We present a platform based on surface tension effects, where the difference in pressure inside drops of unequal volume drives flow in passive structures. We show integration with existing laboratory infrastructure, microfluidic operations such as pumping, routing and compartmentalization without discrete micro-components as well as cell patterning in both monolayer and three-dimensional cell culture.  相似文献   

16.
Chen X  Cui D  Liu C  Li H  Chen J 《Analytica chimica acta》2007,584(2):237-243
A novel integrated microfluidic device that consisted of microfilter, micromixer, micropillar array, microweir, microchannel, microchamber, and porous matrix was developed to perform sample pre-treatment of whole blood. Cell separation, cell lysis and DNA purification were performed in this miniaturized device during a continuous flow process. Crossflow filtration was proposed to separate blood cells, which could successfully avoid clogging or jamming. After blood cells were lyzed in guanidine buffer, genomic DNA in white blood cells was released and adsorbed on porous matrix fabricated by anodizing silicon in HF/ethanol electrolyte. The flow process of solutions was simulated and optimized. The anodization process of porous matrix was also studied. Using the continuous flow procedure of cell separation, cell lysis and DNA adsorption, average 35.7 ng genomic DNA was purified on the integrated microfluidic device from 1 μL rat whole blood. Comparison with a commercial centrifuge method, the miniaturized device can extract comparable amounts of PCR-amplifiable DNA in 50 min. The greatest potential of this integrated miniaturized device was illustrated by pre-treating whole blood sample, where eventual integration of sample preparation, PCR, and separation on a single device could potentially enable complete detection in the fields of point-of-care genetic analysis, environmental testing, and biological warfare agent detection.  相似文献   

17.
The control of cell adhesion is crucial in many procedures in cellular biotechnology. A thermo-responsive poly(N-isopropylacrylamide)-poly(ethylene glycol)-thiol (PNIPAAm-PEG-thiol) copolymer was synthesized for the formation of self-assembled monolayers (SAM) that allow the control of adhesion of cells on gold substrates. The contact angle of water on these layers varies between 65 degrees at a temperature of 45 degrees C and 54 degrees at 25 degrees C. This behaviour is consistent with a transition of the polymer chains from an extended and highly hydrated to a collapsed coil-like state. At 37 degrees C, cultivated fibroblasts adhere and spread normally on this surface and detach by reducing the temperature below the lower critical solution temperature (LCST). Layers can repeatedly be used without loss of their functionality. In order to quantify the capability of the copolymer layer to induce cell detachment, defined shear forces are applied to the cells. For this purpose, the laminar flow in a microfluidic device is used. Our approach provides a strategy for the optimization of layer properties that is based on establishing a correlation between a functional parameter and molecular details of the layers.  相似文献   

18.
19.
This paper presents the design, fabrication and first results of a microfluidic cell trap device for analysis of apoptosis. The microfluidic silicon-glass chip enables the immobilization of cells and real-time monitoring of the apoptotic process. Induction of apoptosis, either electric field mediated or chemically induced with tumour necrosis factor (TNF-alpha), in combination with cycloheximide (CHX), was addressed. Exposure of cells to the appropriate fluorescent dyes, FLICA and PI, allows one to discriminate between viable, apoptotic and necrotic cells. The results showed that the onset of apoptosis and the transitions during the course of the cell death cascade were followed in chemically induced apoptotic HL60 cells. For the case of electric field mediated cell death, the distinction between apoptotic and necrotic stage was not clear. This paper presents the first results to analyse programmed cell death dynamics using this apoptosis chip and a first step towards an integrated apoptosis chip for high-throughput drug screening on a single cellular level.  相似文献   

20.
Sample preparation has long been recognized as a significant barrier to the implementation of macroscopic protocols on microfabricated devices. Macroscopically, such tasks as removing salts, primers and other contaminants are performed by methods involving precipitation, specialized membranes and centrifuges, none of which are readily performed in microfluidic structures. Although some microfluidic systems have been developed for performing sample purification, their complexity may hinder the degree to which they can be implemented. We present a method of microchip-based sample purification that can be performed with even the simplest microfluidic designs. The technique is demonstrated by removing primers from a sample of amplified DNA, leaving only the product DNA. This provides a new sample preparation capability for microfluidic systems.  相似文献   