首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe a novel two-dimensional liquid chromatography (2D-LC) method for fast and robust isolation and concentration of low abundant carbohydrates (sorbitol, glycerol) from biological matrices (plasma and urine). Off-line pre-purified fractions, enriched by analyte of interest, were analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS-MS). Initial 2D-LC automated sample pre-purification improved MS detection, eliminated matrix effects, and achieved high sensitivity (picogram detection limit) with a 6 min runtime and increased column lifetime. Using this method we have analyzed more than 1300 samples from biological matrices without column replacement.  相似文献   

2.
We have developed a fully automatable two-dimensional liquid chromatography platform for shotgun proteomics analyses based on the online coupling of hydrophilic interaction liquid chromatography (HILIC) - using a nonionic type of TSKgel Amide 80 at either pH 6.8 (neutral) or 2.7 (acidic) - with conventional low-pH reversed-phase chromatography. Online coupling of the neutral-pH HILIC and reversed phase chromatography systems outperformed the acidic HILIC-reversed phase chromatography combination, resulting in 18.4% (1914 versus 1617 nonredundant proteins) and 41.6% (12,989 versus 9172 unique peptides) increases in the number of identified peptides and proteins from duplicate analyses of Rat pheochromocytoma lysates. Armed with this optimized HILIC-reversed phase liquid chromatography platform, we identified 2554 nonredundant proteins from duplicate analyses of a Saccharomyces cerevisiae lysate, with the detected protein abundances spanning from approximately 41 to 10(6) copies per cell, which contained up to approximately 2092 different validated protein species with a dynamic range of concentrations of up to approximately 10(4) . This present study establishes a fully automated platform as a promising methodology to enable online coupling of different hydrophilic HILIC and reversed phase chromatography systems, thereby expanding the repertoire of multidimensional liquid chromatography for shotgun proteomics.  相似文献   

3.
Thyreostatic drugs, illegally administrated to livestock for fattening purposes, are banned in the European Union since 1981 (Council Directive 81/602/EC). For monitoring their illegal use, sensitive and specific analytical methods are required. In this study an UHPLC-MS/MS method was described for quantitative analysis of eight thyreostatic drugs in urine, this without a derivatisation step. The sample pretreatment involved a reduction step with dithiothreitol under denaturating conditions at 65 °C, followed by liquid-liquid extraction with ethyl acetate. This analytical procedure was subsequently validated according to the EU criteria (2002/657/EC Decision), resulting in decision limits and detection capabilities ranging between 1.1 and 5.5 μg L−1 and 1.7 and 7.5 μg L−1, respectively. The method obtained for all, xenobiotic thyreostats, a precision (relative standard deviation) lower than 15.5%, and the linearity ranged between 0.982 and 0.999. The performance characteristics fulfill not only the requirements of the EU regarding the provisional minimum required performance limit (100 μg L−1), but also the recommended concentration fixed at 10 μg L−1 in urine set by the Community of Reference Laboratories. Future experiments applying this method should provide the answer to the alleged endogenous status of thiouracil.  相似文献   

4.
In this paper we report a systematic recovery study based on reversed phase high performance liquid chromatography (RP-HPLC) separation and mass spectrometric (MS) based fractionation. Factors including a compound's physicochemical properties, column mass loading and presence of impurities were investigated through commercially available compounds. Results suggest that the delay time between MS peak detection and fraction collection, fraction detector's signal-to-noise ratio and compound's base peak width in the chromatogram have the biggest impacts on purification recovery. In an effort to assess sample recovery within our high throughput purification process, re-purification was performed on four compound libraries that were synthesized in-house. Reproducible recoveries (>80%) were achieved in all tests.  相似文献   

5.
A peptide targeting method has been developed for diagnostic protein discovery, which combines proteolytic digestion of fractionated plasma proteins and liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) profiling. Proteolysis prior to profiling overcomes molecular weight limitations and compensates for the poor sensitivity of matrix-assisted laser desorption/ionization (MALDI) protein profiling. LC/MS increases the peak capacity compared to crude fractionation techniques or single sample MALDI analysis. Differentially expressed peptides are targeted in the mass chromatograms using bioinformatic techniques and subsequently sequenced with MALDI tandem MS. In a model study comparing pancreatic cancer patients to controls, 74% of the peptide targets were successfully sequenced. This profiling method was superior to previous experiments using single sample MALDI analysis for protein profiling or proteolytic peptide profiling, because more potential protein markers were identified.  相似文献   

6.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

7.
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices.  相似文献   

8.
A novel two-dimensional two-column liquid chromatography/mass spectrometry (LC/MS) technique is described in this work, where chromatofocusing (CF) has been coupled to nonporous reversed-phase (NPS-RP) HPLC to separate proteins from human breast epithelial whole cell lysates. The liquid fractions from NPS-RP-HPLC are readily amenable to direct on-line analysis using electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (ESI-TOFMS). A key advantage of this technique is that proteins can be 'peeled off' in the liquid phase from the CF column according to their isoelectric points (pI) in the first chromatographic separation dimension. The NPS-RP-HPLC column further separates these pI-focused fractions based upon protein hydrophobicity as the second chromatographic dimension. The third dimension involves on-line molecular weight determination using ESI-TOFMS. As a result, this method has the potential to be fully automated. In addition, a 2-D protein map of pI versus molecular weight is generated, which is analogous to a 2-D gel image. Thus, this technique may provide a means to study differential expression of proteins from whole cell lysates.  相似文献   

9.
Summary An improved LC method is described for the separation of oxytetracycline and its impurities. The separation is much better than that obtained with official pharmacopoeia methods. The method uses XTerra RP-18, 5 μm (25cm×4.6 mm I.D.), a silica-based stationary phase with methyl end-capping, claimed to reduce silanol activity. The column temperature is set at 30°C and a UV detection is performed at 280 nm. Mobile phase containing acetonitrile −0.25 M tetrabutylammonium hydrogen sulfate pH 7.5−0.25 M ethylenediaminetetraacetic acid pH 7.5-water (115:360:160:365,v/v/v/v) is used at a flow rate of 1.0 mL.min−1, to separate the impurities present in oxytetracycline base. A central composite experimental design is used to optimize the separation. A second isocratic method with higher content of acetonitrile is needed to separate the more retained impurities present only in oxytetracycline hydrochloride. The method is robust and shows good selectivity, repeatability, linearity and sensitivity.  相似文献   

10.
Polycyclic aromatic amines (arylamines) are a class of chemical carcinogens that are prevalent in environmental and industrial settings. They are metabolically activated to covalently bond to DNA, forming mutagenic adducts. In order to study the mechanisms of their toxicity, sensitive and selective quantitative LC/MS/MS detection methods were developed to measure the N-(adenin-8-yl)-benzidine adduct and N-(adenin-8-yl)-2-aminofluorene in total DNA extract samples. A novel synthetic method using a palladium catalyst was previously developed to prepare authentic and deuterated arylamine-adenine adducts to serve as standards. These standards were then used to develop an HPLC electrospray ionization tandem mass spectrometry, isotope dilution method. Sample detection limits in DNA samples were 22 pg on-column and 51 pg on-column for the N-(adenin-8-yl)-benzidine- and N-(adenin-8-yl)-2-aminofluorene-adenine adducts, respectively. This method has applications for the study of DNA adduct formation as a biological marker of exposure to carcinogens and for environmental and workplace monitoring of these aromatic amines.  相似文献   

11.
We demonstrate how visualization of liquid chromatography/mass spectrometry data as a two-dimensional signal intensity map can be used to assess the overall quality of the data, for the identification of polymer contaminants and artifacts, as well as for the confirmation of post-translational modifications.  相似文献   

12.
Diana J  Manyanga V  Hoogmartens J  Adams E 《Talanta》2006,70(5):1064-1072
The official method for the determination of dirithromycin and related substances in the European Pharmacopoeia (Ph. Eur.) and in the United States Pharmacopeia (USP) is an isocratic liquid chromatographic (LC) method using an ODS column. With this method, the separation of the main component dirithromycin from its epimer is not complete. Moreover, this method suffers sometimes from drift of the baseline and from subsequent quantitation problems. The required resolution is not easy to obtain.

Using an adapted method derived from the one prescribed in the pharmacopoeias, the selectivity of a set of more than 40 reversed-phase columns towards dirithromycin components was investigated. The selection of the most suitable column was achieved by the chromatographic response function (CRF) approach. Several changes were introduced to the method in order to improve the separation and to overcome the baseline drift problem. The resulting method uses a Zorbax Extend column maintained at 30 °C and a mobile phase containing acetonitrile, methanol, 2-propanol, water and a phosphate buffer at pH 7.5. The method allows a good separation of dirithromycin components, which is much better than that obtained with the existing methods. Several impurities of unknown identity are also separated. The method shows good repeatability, linearity and sensitivity, and it is robust. In addition, it proved to be applicable to a wide number of C18 reversed-phase columns.  相似文献   


13.
The structural characterization of proteins and peptides isolated in minute quantities requires the most efficient use of available sample. A mass spectrometer data system was programmed to continuously evaluate incoming liquid chromatography/mass spectrometry data against a user-defined array of information. The resulting conclusions were used to automatically set and modify acquisition parameters in real time to collect collision-induced dissociation spectra for selected ions (tandem mass spectrometry). This approach has provided a mechanism to target specific subsets of masses in a complex mixture and/or to discriminate selectively against masses that are known or not of interest. Masses of contaminants or peptide masses derived from known proteins can be automatically recorded and removed from further consideration for collision-induced dissociation analysis. Once recorded, these “libraries” of masses can be used across multiple analyses. This technique directs the mass spectrometer data system to focus on the analysis of masses significant to the user, even if their signal intensities are well below the intensities of contaminating masses. When combined with a database search program to correlate tandem mass spectra to known protein sequences, the identity of the protein can be established unequivocally by using less than 100 fmol of sample.  相似文献   

14.
Hypericum perforatum L. (St. John's Wort) is a widely distributed herbaceous perennial plant which has been well known as a medicinal plant since antiquity. In recent years, H. perforatum has received increasing attention for the treatment of depression and other neuralgic disorders. The main constituents of H. perforatum extract include flavonoids, naphthodianthrones, phloroglucinols, essential oils and xanthones. The present work reports the analysis of naphthodianthrones and phloroglucinols in H. perforatum extracts by means of high performance liquid chromatography (HPLC) coupled simultaneously to a diode array detector (DAD) and electrospray mass spectrometry (ESI-MS). Hypericin, pseudohypericin, hyperforin and adhyperforin were separated and identified on the base of their on-line UV and mass spectra. Quantitative analysis of hypericin derivatives in different extracts of H. perforatum using DAD and MS detectors was performed. In addition, direct infusion ESI-MS of H. perforatum extracts was applied to obtain rapid mass fingerprints of constituents present in the sample.  相似文献   

15.
16.
Fuh MR  Hsieh CJ  Tai YL 《Talanta》1999,49(5):158-1075
This paper describes a newly developed high performance liquid chromatography/electrospray/mass spectrometry (HPLC/ES/MS) method for the determination of flunarizine (FZ) in artificial cerebrospinal fluid. The optimization for the detection of FZ in biological fluid by LC/ES/MS was investigated. The effects of solvent composition, the addition of modifier and flow rate on the detection of FZ by ES/MS were examined. The detection limit of this method (0.8 nM) proved to be much better than previously reported methods. Satisfactory accuracy (98.2–106.0%) of this newly developed method was obtained. The application of this method was demonstrated by analyzing FZ in rat microdialysis samples.  相似文献   

17.
A detection technique for ion suppression in liquid chromatography/mass spectrometry (LC/MS) was developed by adding a probe to an LC mobile phase at a certain concentration. The probe is so hydrophilic that it is not adsorbed in a reversed-phase nanoflow LC column, and, furthermore, has an isoelectric point of about 3, which is lower than that for most peptides and is close to the pH of the mobile phase. The intensity of the protonated probe molecule decreases much more than that of other peptides when ion suppression occurs. Thus, the occurrence of the ion suppression is detected by a decrease in the mass chromatogram for the protonated probe molecule, and the decrease ratio is higher than that for other ions.  相似文献   

18.
The supercritical fluid chromatography coupled with mass spectrometry (SFC‐MS) method and liquid chromatography coupled with mass spectrometry (LC‐MS) method were developed for the separation and characterization of poly (ethylene oxide) methyl glucose sesquistearate (PEO‐Glu‐sesquistearate). The products of PEO‐Glu‐sesquistearate are composed of complex oligomers. The relationship between molecular structure of these oligomers and chromatographic retention behavior in both SFC and LC were discussed and compared. As compared with LC, hydrophobic moieties of compounds favor the fast elution in SFC. The different series can be better separated by LC, while the homologues compounds in same series can be better separated by SFC, and SFC‐MS provided more comprehensive structural information. Different series such as PEO‐distearate, PEO‐stearate, PEO, PEO‐Glu‐tetrastearate, PEO‐Glu‐tristearate, PEO‐Glu‐distearate, PEO‐Glu‐stearate, and PEO‐Glu were identified by MS/MS.  相似文献   

19.
Off-line two-dimensional liquid chromatography with tandem mass spectrometry detection (2D-LC/MS-MS) was used to separate a set of metabolomic species. Water-soluble metabolites were extracted from Escherichia coli and Saccharomyces cerevisae cultures and were immediately analyzed using strong cation exchange (SCX)-hydrophilic interaction chromatography (HILIC). Metabolite mixtures are well-suited for multidimensional chromatography as the range of components varies widely with respect to polarity and chemical makeup. Some currently used methods employ two different separations for the detection of positively and negatively ionized metabolites by mass spectrometry. Here we developed a single set of chromatographic conditions for both ionization modes and were able to detect a total of 141 extracted metabolite species, with an overall peak capacity of ca. 2500. We show that a single two-dimensional separation method is sufficient and practical when a pair or more of unidimensional separations are used in metabolomics.  相似文献   

20.
Acetonitrile as a solvent used in liquid chromatography/mass spectrometry (LC/MS) of peptides and proteins is a relatively toxic solvent (LD50 oral; rat; 2,460 mg/kg) compared to alternatives like methanol (LD50 oral; rat; 5,628 mg/kg) and acetone (LD50 oral; rat; 5,800 mg/kg). Strategies to minimize its consumption in LC are either to reduce the inner diameter of the column or replace acetonitrile with a suitable alternative. Methanol is often recommended to replace acetonitrile in peptide analysis. In this study however, the main focus lies on another alternative solvent for LC/MS of peptides; acetone. A number of model proteins were tryptically digested and the peptide solutions were analyzed on a linear trap quadrupole (LTQ) mass spectrometer. The performances of acetonitrile, methanol and acetone were compared according to the quality of the chromatograms obtained and identification of the peptides using the BioWorks? software developed by Thermo Scientific. In accordance to the elutropic series, acetone was found to significantly reduce the retention times of peptides separated by C18 column material with regard to acetonitrile while methanol led to increased retention times. Acetone was the superior solvent to methanol for most of the tested model proteins reaching similar sequence coverage and numbers of identified peptides as acetonitrile. We therefore propose acetone as an alternative to acetonitrile in LC/MS of peptides. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号