首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this work, a combined methodology using off-line solid-phase extraction (SPE), on-line field-enhanced sample injection (FESI) and coelectroosmotic capillary electrophoresis with UV detection (CE-UV) is developed for the trace analysis of five triazolopyrimidine sulfonanilide pesticides (i.e., flumetsulam, florasulam, cloransulam-methyl, diclosulam and metosulam). An adequate background electrolyte (BGE) was obtained for the separation of these pesticides using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier. This BGE consisted of 0.00042% HDB, 11 mM formic acid, 16 mM ammonium carbonate and 2.5 mM alpha-CD solution at pH 7.6. The use of this running buffer together with the FESI preconcentration method provided limits of detection (LODs) in the low microg/L range (i.e., between 13.0 and 31.5 microg/L). The optimized FESI-CE-UV method was combined with off-line SPE using C(18) cartridges and applied to the determination of the selected group of pesticides in soil samples. Recovery percentages ranged between 50 and 84% in these samples with LODs between 18 and 34 microg/kg. This work shows the great possibilities of the combined use of SPE-FESI-CE-UV to improve CE sensitivity allowing the achievement of LODs similar to other analytical techniques as GC or HPLC.  相似文献   

2.
A transient micellar phase extractor using CTAB was described for the online sample concentration of various anionic analytes (drugs and herbicides) in CE. Stacking and separation was performed at neutral pH in coelectroosmotic flow in a hexadimethrine bromide coated fused‐silica capillary. A micellar plug (e.g. 10 mM CTAB) was injected prior to hydrodynamic injection of the analytes prepared in aqueous organic solvent (e.g. with 30% ACN). In the presence of an electric field, the micelles interacted with the anions inside the capillary. This was followed by selective analyte focusing via the mechanism of micelle to solvent stacking. The micelles acted as transient extractor because the stacking ends when the injected micelles completely migrated through the boundary between the sample and micellar plug. Fundamental studies were performed (effect of surfactant concentration, etc.) and the technique yielded 13‐ to 30‐fold improvements in peak height. A stacking CE method in conjunction with liquid–liquid extraction was also tested for the detection of the herbicides fenoprop and mecoprop in fortified drinking water at analyte concentration levels relevant to Australian Drinking Water Guidelines.  相似文献   

3.
Cao L  Wang H  Zhang H 《Electrophoresis》2005,26(10):1954-1962
The analytical potential of a fluorescein analogue, 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein (SAMF), for the first time synthesized in our laboratory, as a labeling reagent for the labeling and determination of amino compounds by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was investigated. Biogenic monoamines and amino acids were chosen as model analytes to evaluate the analytical possibilities of this approach. The derivatization conditions and separation parameters for the biogenic amines were optimized in detail. The derivatization was performed at 30 degrees C for 6 min in boric acid buffer (pH 8.0). The derivatives were baseline-separated in 15 min with 25 mM boric acid running buffer (pH 9.0), containing 24 mM SDS and 12.5% v/v acetonitrile. The concentration detection limit for biogenic amines reaches 8 x 10(-11) mol.L(-1) (signal-to-noise ratio = 3). The application of CE in the analysis of the SAMF-derivatized amino acids was also exploited. The optimal running buffer for amino acids suggested that weak acidic background electrolyte offered better separation than the basic one. The proposed method was applied to the determination of biogenic amines in three different beer samples with satisfying recoveries varying from 92.8% to 104.8%. Finally, comparison of several fluorescein-based probes for amino compounds was discussed. With good labeling reaction, excellent photostability, pH-independent fluorescence (pH 4-9), and the resultant widely suited running buffer pH, SAMF has a great prospect in the determination of amino compounds in CE.  相似文献   

4.
Two methods are presented for the quantitative capillary electrophoretic (CE) determination of phenolic lignin degradation compounds as well as of inorganic anions and organic acids in Kraft black liquors. Important phenolic lignin degradation compounds can be rapidly separated by co-electroosmotic CE after acidification of the liquors and subsequent extraction of the compounds with chloroform. A capillary electrophoretic separation of phenolic compounds is performed by using a phosphate/borate electrolyte system and UV detection at 214 nm. In addition, a HPLC method using a gradient with water, methanol, and acetic acid is also developed. Inorganic ions which are of importance to the pulping process can be determined by simply diluting the black liquors after sampling and subsequent analysis with a chromate electrolyte system and indirect UV detection at 185 nm. In addition, the concentration of low molecular aliphatic carboxylic acids can be determined simultaneously within the same run. By method optimization it is possible to separate the anions within one minute and, at the same time, to increase the resolution of the solutes. The electrolyte systems for the CE separations were optimized by varying the pH value and by adding organic solvents. Short separation times are obtained by adding a polycationic EOF modifier (hexadimethrine bromide) to the electrolyte which reverses the electroosmotic flow. A migration of the anionic analytes in the same direction as the electroosmotic flow is thus established.  相似文献   

5.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

6.
A new CE method has been developed for the simultaneous determination of selected inorganic anions (bromide, chloride, thiosulfate, nitrite, nitrate, sulfate, thiocyanate, fluoride and phosphate) and organic acids (oxalic, malonic, formic, tartric, acetic, glycolic, propionic, butyric and cyclohexanoic) in amine solutions from sour gas treatment units. An electrolyte composed of 10 mM trimellitic acid, 200 mM Tris (pH 9.0), 0.1% polyvinyl alcohol provides a satisfactory separation of all analytes of interest. The electroosmotic flow is reversed by using hexadimethrine bromide as a semi-permanent positively charged coating, making the electrolyte free of additive. Indirect UV detection at 240 nm is used because of the weak absorbing properties of most of analytes. The addition of 1% diethanolamine in standard mixtures permits to better preserve them, inhibiting potential degradation processes, especially for thiosulfate. The quantification is performed using internal standardization, by which molybdate is used as internal standard. Moreover, the use of relative migration times and the excellent repeatabilities obtained allow unambiguous identification of analytes in real samples by comparison with standard mixture. It has been shown that no significant matrix effect came from the presence of 30% diethanolamine in amine solution samples and the developed method was characterized in terms of calibration linearity and accuracy using recovery tests. In short, the developed method allows the simultaneous and rapid determination, in difficult matrices, of numerous inorganic anions and organic acids characterized by a large range of electrophoretic mobilities.  相似文献   

7.
The development of new sensitive methods for the analysis of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples is of great importance. In this work, seven NSAIDs were separated within 9 min using 15 mM sodium tetraborate (pH 9.2) containing 0.1% (w/v) hexadimethrine bromide (HDMB) and 10% (v/v) methanol. Field-amplified sample injection (FASI) was examined and found to improve the detection limits by 200-fold providing detection limits of 0.6-2.0 microg/L, but these are insufficient for the determination of NSAIDs as environmental pollutants in water samples. To improve the sensitivity further, electrokinetic supercharging (EKS) was examined. The optimum EKS method involved hydrodynamic injection leading electrolyte (100 mM NaCl, 30 s, 50 mbar), electrokinetic injection of the sample (200 s, -10 kV) and finally injection of the terminating electrolyte (100 mM 2-(cyclohexylamino) ethanesulphonic acid, CHES, 40s, 50 mbar). With this method, the sensitivity was improved by 2400-fold giving detection limits of 50-180 ng/L. The developed method was validated and then applied to the analysis of wastewater samples from a local sewage treatment plant. The detection limits were found to increase by approximately 10-fold, however, this is still lower than levels previously found in wastewater samples from European and Mediterranean cities. The proposed method has the advantage of simplicity and achieving sensitivity through high-preconcentration power without the use of off-line chromatographic sample cleanup.  相似文献   

8.
付国妮  何友昭  王晓葵  王蕾 《色谱》2007,25(2):193-196
改进的毛细管电泳-间接紫外吸收法采用了自制隔离池,以对氨基苯甲酸(PAB)为背景电解质,对茶叶中的氨基酸进行了测定。PAB能够提高分离效率,降低检出限。隔离池的使用避免了PAB的电极反应,降低了基线噪声,维持了两缓冲液池间的电流导通。研究了背景电解质的浓度、pH值以及电渗流改性剂的种类和浓度对氨基酸分离的影响。在优化的实验条件下,16种氨基酸在14 min内达到了基线分离,峰面积的相对标准偏差小于5%(n=5),检出限为1.7~4.5 μmol/L,回收率为83.0%~106%。该法快速、便捷和灵敏,已成功应用于茶叶中11种游离氨基酸的检测。  相似文献   

9.
A simple and rapid capillary electrophoresis method for low-molecular mass carboxylic acids measurement in coffee has been optimised and validated. Regarding separation conditions, phosphate concentration in the background electrolyte, surfactant type [cetyltrimethylammonium bromide (CTAB), tetradecyltri methylammonium bromide (TTAB) and hexadimethrine bromide (HDB)], percentages of organic modifier and pH were assayed. The best conditions were: 500 mM phosphate buffer at pH 6.25 with CTAB 0.5 mM. The separation was carried out with an uncoated fused-silica capillary (57 cm x 50 microm i.d.) which was operated at -10 kV potential. Detection was performed at 200 nm. In such conditions 17 short-chain organic acids: oxalic, formic, fumaric, mesaconic, succinic, maleic, malic, isocitric, citric, acetic, citraconic, glycolic, propionic, lactic, furanoic, pyroglutamic, quinic acids plus nitrate were separated, identified and measured. Validation parameters of the method allow us to consider it lineal, accurate and precise and, therefore, reliable for its employment in food composition studies or for quality control. Results in coffees with different industrial treatment allow the detection of important differences in the organic acid profile.  相似文献   

10.
Dynamic pH junction is an online focusing method in CE based on the electrophoretic mobility difference of analytes in the sample matrix and the background electrolyte. An advantage of this method over the conventional CE is that the sensitivity can be significantly improved. By injecting a long sample plug in the capillary and focusing the analytes at the pH boundary between the background electrolyte and sample matrix, the LOD can be improved by 10–100 folds. The dynamic pH junction method can be easily coupled with ESI‐MS. In this work, we used this method for the analysis of microcystins (MCs). The detection limits and dynamic ranges were studied. The separation was optimized by adjusting the injection time, and concentrations and pH values of the background electrolyte. The optimization of analyte focusing leads to enhanced detection response compared to conventional injections, achieving 200–400 fold higher averaged peak heights for four microcystin (MC) variants. More importantly, this method was successfully used for the quantitative analysis of microcystins (MCs) in crude algae samples from natural water bodies, making it promising for practical applications.  相似文献   

11.
A simple technique is described for the routine capillary electrophoretic determination of organic acids in wine samples. Several aromatic and non‐aromatic compounds, including phthalic acid, benzoic acid, sorbic acid, boric acid, and phosphate, were evaluated as background electrolytes in order to obtain the highest resolution and detection sensivity. Factors that affect capillary electrophoretic separation such as the concentration and pH of the background electrolyte (BGE), the concentration of the electroosmotic flow modifier (EOF), and methanol addition to the electrolyte were investigated systematically. Tartaric, malic, succinic, acetic, and lactic acids were determined simultaneously in approximately six minutes using an electrolyte containing 3 mM phosphate and 0.5 mM myristyltrimethylammonium bromide (MTAB) as electroosmotic flow modifier at pH 6.5. This method is quantitative, with recoveries in the 90–102% range and linear up to 50 mg L–1. The precision is better than 1% and the procedure shows the appropriate sensibility, with detection limits between 0.015 and 0.054 mg L–1. The proposed method was successfully employed for the determination of organic acids in wine samples by direct sample injection after appropriate dilution and filtration.  相似文献   

12.
A method was developed for the determination of phosphoamino acids by capillary zone electrophoresis-laser-induced fluorescence detection (argon ion laser, excitation at 488 nm and emission at 520 nm) using derivatization with N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA). Different variables affecting the derivatization (SIFA concentration, derivatization pH, reaction temperature and reaction time) and the separation (type, pH and concentration of buffer, applied voltage and injection mode) were investigated in detail. The optimized separation conditions were 40 mM boric acid buffer (pH 9.2) for background electrolyte, 25 kV for the separation voltage, 25 degrees C for the capillary temperature and 5 s at 0.5 psi for the sample injection. Under the optimal conditions, the SIFA-labeled phosphoamino acids were fully separated within 7 min. The detection limits ranged from 0.1 to 0.3 nM, which are the lowest values reported for capillary electrophoresis (CE) methods. The proposed methodology allowed the rapid, sensitive and selective determination of phosphoamino acids in hen egg yolk phosvitin by the standard addition method. The recovery of these compounds in real sample was 94.0-103.5%. The developed method surpasses previously published CE methods in terms of detection limit, separation time, stability and simplicity of the electrophoretic procedure.  相似文献   

13.
Capillary electrophoresis (CE) is a powerful technique for enantiomer separations due to its intrinsic high separation efficiencies, speed of analysis, low reagent consumption and small sample requirements. However, some chiral selectors present strong background UV absorption providing high detection limits. The present paper deals with the application of the partial-filling technique to the separation of bupivacaine enantiomers by capillary electrophoresis using human serum albumin (HSA) as chiral selector. In this procedure the cationic surfactant cetyltrimethylammonium bromide (CTAB) was used as a dinamic capillary coating in order to reduce the electro-osmotic flow and detect both bupivacaine enantiomers out of the chiral selector plug. Several experimental conditions such as CTAB concentration, pH, HSA concentration and plug length, background electrolyte concentration, temperature and voltage were studied. Under the selected conditions it is possible to detect the separated enantiomers out of the HSA plug in less than 4 min using 50 mM Tris pH 8 as background electrolyte with 50 microM CTAB, at 30 degrees C and using a separation voltage of 25 kV. The proposed methodology was then validated for analytical purposes and applied to the analysis of pharmaceutical preparations commercially available. The results obtained with the proposed methodology were in good agreement with those declared by the manufacturers. The simplicity, sample throughput, accuracy, reproducibility and low cost of the proposed method make it suitable for the control of the enantiomeric composition of bupivacaine in pharmaceuticals.  相似文献   

14.
Yang W  Zhang Z  Deng W 《Talanta》2003,59(5):951-958
A novel chemiluminescence (CL) detection scheme has been developed for detecting underivatized amino acids following capillary electrophoresis (CE) separation. This detection was based on the inhibitory effect of amino acids on the CL reaction between luminol and BrO in alkaline aqueous solution. Detection of amino acids was accomplished with a borate-based background electrolyte at pH 9.2. The luminol was used as a component of the separation carrier electrolyte. Parameters affecting CE-CL separation and detection, such as the pH value, the concentration of electrolyte and CL reagent on the resolution were optimized. The relative standard deviation for the analysis of amino acids was less than 1.5% for the migration time and 4% for the peak height. The mass limits of detection were from 7 to 144 fmol for the 7 amino acids. This method has been applied of 7 amino acids in amino acid injection.  相似文献   

15.
A capillary electrophoresis (CE)-indirect fluorescence detection method is described for the simultaneous determination of glufosinate, glyphosate and aminomethylphosphonic acid. The three analytes were separated by CE in 5 min with a 1 mM fluorescein solution at pH 9.5. Fluorescein also functioned as a background fluorophore for the indirect detection of these nonfluorescent species. Linearity of more than two orders of magnitudes was generally obtained. The concentration limits of detection were in the microM range. Precisions of migration times and peak areas were less than 1.7% and 7.4%, respectively. Quantitation of glyphosate and glufosinate in commercial herbicides is demonstrated. In addition, the applicability of the method for the analysis of ground water was examined.  相似文献   

16.
A new, simple, and rapid capillary electrophoresis (CE) method employing hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier was developed for the identification and quantitative determination of two pharmaceutically active constituents—gallic acid (GA) and salidroside (S)—in extracts of Rhodiola root and its medicinal preparation. The optimum separation was achieved at pH 11.00 with the use of 10 mM borate buffer containing 0.001% (w/v) of HDB. The applied voltage was ∼15 kV and the capillary temperature was kept constant at 25°C. m-Phthalic acid was used as an internal standard for quantification. The calibration dependences exhibited good linearity for the ratios of the concentrations of standard samples and internal standard and the ratios of the peak area of samples and internal standard over the concentration range from 24 to 1200 μg/mL for GA and 2.4 to 72 μg/mL for S. The correlation coefficients were 0.9999 and 0.9997, and the detection limits of the CE method corresponding to a signal-to-noise ratio of three were 6 and 2 μg/mL for GA and S, respectively. The relative standard deviations of the relative migration time and the relative peak area of samples were 0.5 and 4.0% for GA and 1.9 and 5.3% for S. The effects of buffer pH and the concentration of HDB on the resolution were studied systematically. The contents of these two active compounds in Rhodiola root and its preparation were successfully determined over 6 min with satisfactory repeatability and recovery. The text was submitted by the authors in English.  相似文献   

17.
《Electrophoresis》2018,39(17):2246-2252
Upconversion nanoparticles (UCNPs) are an emerging class of optical materials with high potential in bioimaging due to practically no background signal and high penetration depth. Their excellent optical properties and easy surface functionalization make them perfect for conjugation with targeting ligands. In this work, capillary electrophoretic (CE) method with laser‐induced fluorescence detection was used to investigate the behavior of carboxyl‐silica‐coated UCNPs. Folic acid, targeting folate receptor overexpressed by wide variety of cancer cells, was used for illustrative purposes and assessed by CE under optimized conditions. Peptide‐mediated bioconjugation of antibodies to UCNPs was also investigated. Despite the numerous advantages of CE, this is the first time that CE was employed for characterization of UCNPs and their bioconjugates. The separation conditions were optimized including the background electrolyte concentration and pH. The optimized electrolyte was 20 mM borate buffer with pH 8.  相似文献   

18.
Kubán P  Kubán P  Kubán V 《Electrophoresis》2003,24(12-13):1935-1943
A simple and inexpensive flow injection-capillary electrophoresis (FI-CE) system with contactless conductivity detection (CCD) for automated quantitative analysis of chloride, nitrate, and sulfate in various water samples is demonstrated. A glass bottle containing the background electrolyte that is raised above the FI-CE interface generates a pulse-free, highly reproducible flow of the electrolyte through the FI-CE interface. The system operates at a flow rate of 300 microLmin(-1) with an injection volume of only 4 microL. The repeatability of peak areas (n = 18) was better than 0.81% RSD and the sample throughput was 90 samples per hour using the background electrolyte containing 12 mM L-histidine adjusted to pH 4.00 with acetic acid. The limits of detection were better than 125 microgL(-1) and were comparable to those obtained by conventional CE systems with CCD. Various calibration methods for FI-CE system with electrokinetic injection were tested and their suitability for the analysis of anions in real samples was evaluated.  相似文献   

19.
In this study, the partial filling technique on both polycationic polymer hexadimethrine bromide (HDB) modified capillary and eCAP neutral capillary were systematically compared in order to enhance the enantioseparation ability of bromobalhimycin as CE additive. The separation conditions, such as pH, the plug length, and the concentration of bromobalhimycin, etc., were optimized in order to obtain satisfactory separations. As expected, for all tested 28 N‐benzoylated amino acids, up to five times higher enantioresolutions were obtained on the eCAP neutral capillary compared to that on the polycationic polymer hexadimethrine bromide modified capillary. Moreover, 26 of 28 tested racemic compounds were almost baseline‐ resolved without observing any interference from the front of the plug of bromobalhimycin. Although the limitation of longer running time on the neutral capillary, it allows the use of higher content of bromobalhimycin in the running buffer without any interference on the detection of analytes when enantioseparations are more difficult to obtain.  相似文献   

20.
Capillary zone electrophoresis (CZE) with indirect UV detection was developed for the simultaneous determination of inorganic anions and organic acids in environmental samples. Various aromatic acids (benzoic, phthalic, trimellitic, and pyromellitic acids) were evaluated as background electrolytes (BGEs) to give high resolution and detection sensitivity. Co-electroosmotic conditions such as the concentration of BGE, electrolyte pH, and EOF modifier were systematically investigated. Three inorganic anions and ten organic acids were determined simultaneously in 10 min using an electrolyte containing 10 mM phthalic acid, 0.5 mM myristyltrimethylammonium bromide (MTAB), and 5% methanol (MeOH) (v/v) at pH 5.60. Linear plots for the test solutes were obtained in the concentration range 0.01–1.0 mM with detection limits in the range 5–30 μM. The proposed method was successfully demonstrated for the determination of inorganic anions and organic acids in natural water, soil, and plant extracts after direct sample injection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号