首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bisphenol A (BPA) is one of the environmental endocrine-disrupting chemicals used widely in common consumer products. There is an increasing concern about human exposure to BPA, particularly in fetuses, due to the potential adverse effects related to the estrogenic activity of BPA. In assessing environmental exposure to BPA, it is essential to have a sensitive, accurate, and specific analytical method, particularly for low BPA levels in complex sample matrices. In this study, we developed and validated an accurate, sensitive, and robust liquid chromatography-mass spectrometry (LC-MS) method for determining the BPA concentrations in human amniotic fluid (AF). In this method, BPA and the internal standards (13)C(12) -BPA were extracted from 500 μL of human AF using solid-phase extraction. Calibration curves were linear over a concentration range of 0.3-100 ng/mL for BPA. The analytes were quantitatively determined using LC-MS operated in a negative electrospray ionization selected ion monitoring mode. This validated method has been used successfully in the clinical sample analysis of BPA in second-trimester AF specimens.  相似文献   

2.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

3.
An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid-liquid extraction with ter-butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25--1000 ng/mL using 200 microL plasma aliquots. The method requires only a limited volume (200 microL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel.  相似文献   

4.
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid‐phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid‐phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0–1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015–0.591 and 0.045–1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1‐monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m?3. 9,10‐Dichloroanthracene and 1‐monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water.  相似文献   

5.
Di‐(2‐ethylhexyl)phthalate (DEHP) was determined in environmental samples such as water and soil. DEHP was extracted from water samples using SPE, whereas for soils pressurized liquid extraction was applied as extraction method, using hexane/acetone (1:1, v/v) as extractant solvent. The use of HPLC coupled to MS provides the basis of the selective determination of DEHP in the analyzed samples. The extraction procedures were validated and good results were found. Recoveries were ranged from 86.0 to 99.8% with RSD lower than 18% and LODs were 0.02 mg/kg and 0.03 μg/L for soils and water, respectively. Finally, the optimized methods were applied to the analysis of real samples and DEHP was not found above the LOQ (0.05 mg/kg) in soil samples whereas it was detected in water samples at concentrations ranging between 0.19 to 0.88 μg/L.  相似文献   

6.
建立了同时测定渔业养殖水中氢化可的松、泼尼松、醋酸可的松、睾酮、甲睾酮、黄体酮及苯丙酸诺龙等7种激素残留药物的超高压液相色谱-电喷雾电离串联质谱(UPLC-ESI-MS/MS)分析方法.水样用HLB固相萃取柱净化、浓缩后,洗脱液经氮气吹干,残渣用乙腈-水(V∶V=1∶1)溶解,以乙腈和0.1%甲酸水溶液为流动相,经ZORBAXSB-C18色谱柱分离后进行LC-MS/MS多反应检测模式作定性定量分析.方法在0.5~40μggL或1~40μg/L范围具有良好的线性,相关系数大于0.997,检出限(S/N=3)为0.03~0.3μg/L,平均回收率为74.8%~113.0%,相对标准偏差为4.0%~16%.方法适用于渔业养殖水中7种激素的检测分析.  相似文献   

7.
A simple and sensitive method for the determination of organophosphate esters in water samples by mixed‐mode liquid chromatography with electrospray ionization tandem mass spectrometry coupled with solid‐phase extraction is developed. Using seven alkyl phosphates, three chlorinated alkyl phosphates, and four aryl phosphates as the targets, the developed method was systematically evaluated on the basis of the influence of the solid‐phase extraction cartridge, eluting solvent, sample‐loading volume, mobile phase condition, and the separation of reversed‐phase chromatography and mixed‐mode liquid chromatography. Under the optimal conditions, these organophosphate esters can be extracted by ENVI‐18 cartridge, eluted by 6 mL of 25% dichloromethane in acetonitrile, and then qualified and quantified by mixed‐mode liquid chromatography with tandem mass spectrometry in the multiple reaction‐monitoring mode. The application of mixed‐mode liquid chromatography endows the separation with reasonable retention for both hydrophilic and hydrophobic organophosphate esters regardless of their polarity, which is hardly achieved by reversed‐phase chromatography. Good linearity (from 0.9877 to 0.9969), low quantification limits (1–35 ng/L after extraction of 100 mL of river water), and acceptable recovery rates (58.6–116.2%, with the relative standard deviation <18.0%) were obtained. Finally, the established method was used for analyzing surface water samples, and the good applicability of this method was demonstrated.  相似文献   

8.
A sensitive and selective liquid chromatography coupled to tandem mass spectrometry (LC‐MS/MS) was developed and validated for the determination of salbutamol in human plasma and urine, and successfully applied to the pharmacokinetic study of salbutamol in Chinese healthy volunteers after inhalation of salbutamol sulfate aerosol. Salbutamol and the internal standard (IS) acetaminophen in plasma and urine were extracted with ethyl acetate, separated on a C18 reversed‐phase column, eluted with mobile phase of acetonitrile–ammonium acetate (5 m m ; 30:70, v/v), ionized by positive ion pneumatically assisted electrospray and detected in the multi‐reaction monitoring mode using precursor → product ions of m/z 240.2 → 148.1 for salbutamol and 152 → 110 for the IS. The lower limits of quantitation of salbutamol in human plasma and urine by this method were 0.02 and 1 ng/mL, respectively. The specificity, matrix effect, recovery, sensitivity, linearity, accuracy, precision and several stabilities were validated for salbutamol in human plasma and urine. In conclusion, the validation results showed that this method is robust, specific and sensitive, and can successfully fulfill the requirement of clinical pharmacokinetic study of salbutamol in healthy Chinese volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid, sensitive and selective liquid chromatography-tandem spectrometry method was developed and validated for determination of paeoniflorin in rat plasma using geniposide as the internal standard. The samples were pretreated with solid-phase extraction using Extract-Clean cartridges. Separation of paeoniflorin and IS was achieved on a reversed-phase C18 column (50x4.6 mm i.d.) with a mobile phase made up of acetonitrile and 0.05% formic acid (25:75, v/v) at a flow rate of 0.5 mL/min. Detection was carried out on a triple quadrupole tandem mass spectrometer by multiple-reaction monitoring and an electrospray ionization source was employed as the ionization source. The lower limit of quantification obtained was 4 ng/mL (n=6) using 200 microL plasma with an accuracy of -3.67% (relative error) and a precision of 4.13% (relative standard deviation). A good linearity was found in the range of 4-1000 ng/mL. The intra- and inter-day relative standard deviations in the measurement of quality control samples 10, 150 and 800 ng/mL ranged from 3.73 to 4.94% and from 4.31 to 6.56%, respectively. The accuracy was from -3.93 to -1.11% in terms of relative error. The analyte and IS were stable in the battery of stability studies. This method was successfully applied to a pharmacokinetic study of paeoniflorin after a single oral administration of 53.36 mg/kg paeoniflorin to rats.  相似文献   

10.
In the present work, we have developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the identification and quantification of vitamin B5 in human urine. Urine was spiked with vitamin B5 internal standard, hopantenic acid (HOPA), and then diluted with the LC mobile phase prior to its analysis by LC/MS. The quantification was performed in single ion monitoring mode. The calibration curve was linear (r2 = 0.999) between 0.25 to 10 microg/mL. With a limit of detection of 0.1 microg/mL the method was sensitive enough to determine low levels of vitamin B5 in urine. The overall quantitative efficiency of the method was evaluated by spiking urine samples with four different concentrations of vitamin B5; the intra-assay coefficient of variation was below 5% and the recoveries were between 96 to 108%. The results of the present study show that the proposed method is selective and sensitive enough for the quantification of vitamin B5 in urine.  相似文献   

11.
The supercritical fluid chromatography coupled with mass spectrometry (SFC‐MS) method and liquid chromatography coupled with mass spectrometry (LC‐MS) method were developed for the separation and characterization of poly (ethylene oxide) methyl glucose sesquistearate (PEO‐Glu‐sesquistearate). The products of PEO‐Glu‐sesquistearate are composed of complex oligomers. The relationship between molecular structure of these oligomers and chromatographic retention behavior in both SFC and LC were discussed and compared. As compared with LC, hydrophobic moieties of compounds favor the fast elution in SFC. The different series can be better separated by LC, while the homologues compounds in same series can be better separated by SFC, and SFC‐MS provided more comprehensive structural information. Different series such as PEO‐distearate, PEO‐stearate, PEO, PEO‐Glu‐tetrastearate, PEO‐Glu‐tristearate, PEO‐Glu‐distearate, PEO‐Glu‐stearate, and PEO‐Glu were identified by MS/MS.  相似文献   

12.
The determination of polycyclic aromatic hydrocarbons (PAHs) using high-performance liquid chromatography (HPLC) with UV and fluorescence detection has been well established. Although most of the PAHs can be detected by these methods, some environmentally important polyaromatic compounds, such as acenaphthylene, do not show fluorescence and can only be determined by UV detection at higher concentrations. A sensitive and selective determination of acenaphthylene, acenaphthene and the six PAHs listed in the TVO, the German drinking water standard, is also possible by amperometric detection following HPLC separation. The method was applied to the determination of PAHs in different water samples after solid-phase extraction (SPE). The efficiency of the amperometric determination was found to be superior to UV detection (λ = 300 nm).  相似文献   

13.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

14.
Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, < 7%), correlation coefficient (> 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.  相似文献   

15.
The molecularly imprinted SPE directly coupled to RP LC‐MS/MS method has been developed and successfully validated for the determination of six hormones in water and sediment samples. The method is based on the use the home‐made column filled with a molecularly imprinted sorbent (imprinted against estrogens) that was used under nonaqueous conditions. Thus, its high selectivity could be utilized resulting in low matrix components’ coextraction. The method showed excellent recovery (92–105%) and satisfactory sensitivity (LOQs water: 1.9–4.0 ng/L; LOQs sediment: 0.2–0.5 ng/g). The intra‐ and interprecision for water and sediment was in the range of 4.0–6.0% and 4.4–7.6%, respectively. Finally, 20 water and sediment samples collected from the Svratka river were analyzed. Only estrone was quantified in eight water samples (4.4–7.1 ng/L); no analytes were found in sediment samples.  相似文献   

16.
Atrasentan (A-147627) is an endothelin antagonist receptor being developed at Abbott Laboratories for the treatment of prostate cancer. A quick and sensitive method for the determination of atrasentan in human plasma has been developed and validated using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. A dual-column, single mass spectrometer system is used to provide a reliable and routine means to increase sample throughput. The analytical method involves liquid-liquid extraction and internal standard (A-166790). The plasma samples and internal standard are acidified with 0.3 M hydrochloric acid prior to being extracted into 1:1 (v/v) hexanes--methyl t-butyl ether. The organic extract was evaporated to dryness using heated nitrogen stream and reconstituted with mobile phase. Atrasentan and internal standard were separated with no interference in a Zorbax SB-C(18) analytical column with 2.1 x 50 mm, 5 microm, and a Zorbax C(8) guard column using a mobile phase consisting of 50:50 (v:v) acetonitrile--0.05 M ammonium acetate, pH 4.5, at a flow rate of 0.30 mL/min to provide 4 min chromatograms. For a 250 microL plasma sample volume, the limit of quantitation was approximately 0.3 ng/mL. The calibration was linear from 0.30 to 98.0 ng/mL (r(2) > 0.995). A significant advantage of the method is the ability to employ parallel HPLC separations with detection by a single MS/MS system to provide sensitivity and selectivity sufficient to achieve robust analytical results with a lower limit of quantitation of 0.30 ng/mL and high throughput.  相似文献   

17.
A sensitive and selective liquid chromatography mass spectrometry method for determination of curdione in rabbit plasma was developed. After addition of tramadol as internal standard (IS), protein precipitation by acetonitrile was used for sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 50 mm, 3.5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive‐ion mode; selective ion monitoring was used for quantification using target fragment ions m/z 237 for curdione and m/z 264 for the IS. Calibration plots were linear over the range of 20–4000 ng/mL for curdione in plasma. The lower limit of quantification for curdione was 20 ng/mL. Mean recovery of curdione from plasma was in the range 94.3–98.4%. The RSD of intra‐day and inter‐day precision were both less than 9%. This method is simple and sensitive enough to be used in pharmacokinetic research for the determination of curdione in rabbit plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
A simultaneous determination method using solid‐phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid‐phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1–74.3 and 0.5–236.6 ng/L, respectively. Accuracy and precision values were 71–120 and 1–17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water.  相似文献   

19.
A new method of flaxseed-derived lignan determination was developed using HPLC with high-resolution time-of-flight MS (TOF-MS), optimized, and compared to two existing methods (HPLC/MS/MS and GC/MS). The limits of detection (LODs) for HPLC/TOF-MS (0.002–0.043 pg) were comparable with those of the optimized and improved HPLC/MS/MS (0.001–0.015 pg), whereas the LODs for the optimized GC/MS were higher (0.02–3.0 pg, yet lower than reported before). Using the newly developed detection and separation methods, several key flaxseed sample preparation parameters (including extraction, hydrolysis, and sample purification) were evaluated resulting in the development of efficient protocol for lignan quantification from flaxseed hulls and embryos. The results confirmed the importance of quantification of both aglycones and unhydrolyzed glucosides in order to obtain the total lignan estimates.  相似文献   

20.
A highly sensitive method based on solid‐phase extraction and ultra high performance liquid chromatography with electrospray tandem mass spectrometry has been developed for simultaneous determination of five iodinated X‐ray contrast media in environmental water samples. Various solid‐phase extraction cartridges have been evaluated and a combination of LiChrolute EN and ENVI‐Carb solid phase extraction cartridges was selected for sample enrichment. The method was comprehensively validated on ground water, tap water, surface water, drinking water, and waste water by the conventional procedures: linearity, method detection limits, accuracy and precision, matrix effects. Good linearity (R2 > 0.999), low detection limits (0.4–8.1 ng/L), satisfactory recoveries (55.1–109.5%) and precision (0.8–10.0% for intra‐day precisions and 0.6–16.5% for inter‐day precisions) were obtained for all the target compounds. Iopamidol, iohexol, and diatrizoate in some matrices were affected by matrix effects, which were slightly eased by using the isotope‐labeled internal standard. The developed method was successfully applied for real samples collected in Shanghai, China, with detected concentrations up to 2200 ± 200 and 9000 ± 1000 ng/L for iohexol and iopamidol, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号