首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
A rapid and solvent‐free procedure for the determination of 4‐tert‐octylphenol and 4‐nonylphenol isomers in aqueous samples is described. The method involves in‐situ acetylation and microwave‐assisted headspace solid‐phase microextraction prior to their determination using gas chromatography–ion trap mass spectrometry operated in the selected ion storage mode. The dual experimental protocols to evaluate the effects of various derivatization and extraction parameters were investigated and the conditions optimized. Under optimized conditions, 300 μL of acetic anhydride mixed with 1 g of potassium hydrogencarbonate and 2 g of sodium chloride in a 20 mL aqueous sample were efficiently extracted by a 65 μm polydimethylsiloxane‐divinylbenzene fiber that was located in the headspace when the system was microwave irradiated at 80 W for 5 min. The limits of quantitation were 5 and 50 ng/L for 4‐tert‐octylphenol and 4‐nonylphenol isomers, respectively. The precision for these analytes, as indicated by relative standard deviations, were less than 8% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 to 88%. A standard addition method was used to quantitate 4‐tert‐octylphenol and 4‐nonylphenol isomers, and the concentrations ranged from 120 to 930 ng/L in various environmental water samples.  相似文献   

2.
3.
A simple and sensitive method was developed for the simultaneous separation and determination of trace earthy-musty compounds including geosmin, 2-methylisoborneol, 2-isobutyl-3-methoxypyrazine, 2-isopropyl-3-methoxypyrazine, 2,3,4-trichloroanisole, 2,4,6-trichloroanisole, and 2,3,6-trichloroanisole in water samples. This method combined headspace solid-phase microextraction (HS-SPME) with gas chromatography-mass spectrometry and used naphthalene-d(8) as internal standard. A divinylbenzene/carboxen/polydimethylsiloxane fiber exposing at 90°C for 30 min provided effective sample enrichment in HS-SPME. These compounds were separated by a DB-1701MS capillary column and detected in selected ion monitoring mode within 12 min. The method showed a good linearity from 1 to 100 ng L(-1) and detection limits within (0.25-0.61 ng L(-1)) for all compounds. Using naphthalene-d(8) as the internal standard, the intra-day relative standard deviation (RSD) was within (2.6-3.4%), while the inter-day RSD was (3.5-4.9%). Good recoveries were obtained for tap water (80.5-90.6%), river water (81.5-92.4%), and lake water (83.5-95.2%) spiked at 10 ng L(-1). Compared with other methods using HS-SPME for determination of odor compounds in water samples, this present method had more analytes, better precision, and recovery. This method was successfully applied for analysis of earthy-musty odors in water samples from different sources.  相似文献   

4.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

5.
A fast method was optimized and validated with the aim to detect cannabinoids (cannabidiol, cannabinol, and delta-9-tetrahydrocannabinol) in human head hair samples. The method was based on an initial procedure of external decontamination of hair samples (10 mg) with petroleum ether, followed by alkaline digestion and further extraction of cannabinoids by means of a headspace solid-phase microextraction technique (HS-SPME). GC-MS was used to identify and quantify the analytes in SIM mode. The LOQs and LODs obtained were 0.07 and 0.12 ng/mg, respectively, for all the studied cannabinoids. The method proved to be simple, rapid, and precise. By using the weighted least squares linear regression (weighting factor 1/x2), the accuracy of the analytical method was improved at the lower end of the calibration curve (from 0.12 to 12 ng/mg; r >0.98). Hair samples collected from eight volunteers (in-patients of a drug abuse rehabilitation clinic) were submitted to the proposed method. Detection of the drugs was observed in samples of the volunteers who reported frequent marijuana use (at least ten times a week).  相似文献   

6.
采用顶空固相微萃取与气相色谱-质谱联用技术,对八角茴香中风味物质进行了分析。选用自制聚丙烯酸树脂涂层,对样品量、萃取时间、萃取温度、解吸时间等参数进行了优化,结果表明0.10g样品在60℃水浴中顶空萃取40min,250℃下解吸2min达到最佳条件。比较了顶空固相微萃取与传统水蒸气蒸馏两种前处理方法,分析结果非常相似。该方法可用于快速分析八角茴香中的风味物质。  相似文献   

7.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

8.
In the present work, a method was developed and optimized aiming at the determination of anatoxin-a in environmental water samples. The method is based on the direct derivatization of the analyte by adding hexylchloroformate in the alkalinized sample (pH = 9.0). The derivatized anatoxin-a was extracted by a solid-phase microextraction (SPME) procedure, submersing a PDMS fiber in an amber vial for 20 min under magnetic stirring. GC-MS was used to identify and quantify the analyte in the SIM mode. Norcocaine was used as internal standard. The following ions were chosen for SIM analyses (quantification ions in italics): anatoxin-a: 191, 164, 293 and norcocaine: 195, 136, 168. The calibration curve showed linearity in the range of 2.5-200 ng/mL and the LOD was 2 ng/mL. This method of SPME and GC-MS analysis can be readily utilized to monitor anatoxin-a for water quality control.  相似文献   

9.
The possibility of quantitative analysis of aromatic hydrocarbons in oil-based asphalt release agents was investigated using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The target analytes studied were benzene, toluene, ethylbenzene, p-, m-, and o-xylene (BTEX) and 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene. Experimental parameters influencing HS-SPME efficiency were studied (equilibration time between sample and headspace and between headspace and SPME fiber, sample amount and sample matrice effects). A HS-SPME method using hexadecane as a surrogate matrice was developed. The detection limit was estimated as 0.03-0.08 ppm (w/w) for the target analytes investigated. Good linearity was observed (R2 > 0.999) for all calibration curves at high, medium and low concentration level. The repeatability of the method (RSD, relative standard deviation) was found to be less than 10% (generally less than 5%) in triplicate samples and approximately 2% at eight consecutive tests on one and the same sample. The accuracy of the method given by recovery of spiked samples was between 85 and 106% (generally between 95 and 105%). The HS-SPME method developed was applied to four commercially available asphalt release agents. External calibration and standard addition approaches were investigated regarding accuracy. The results showed that standard addition generates higher accuracy than external calibration. The contents of target aromatic hydrocarbons in the asphalt release agents studied varied greatly from approximately 0.1-700 ppm. The method described looks promising, and could be a valuable tool for determination of aromatic hydrocarbons in different types of organic matrices.  相似文献   

10.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

11.
This investigation evaluates headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to determine trace levels of organotins in water. The organotins were derivatized in situ with sodium tetraethylborate and adsorbed on a poly(dimethysiloxane) (PDMS)-coated fused silica fiber. The SPME experimental procedures to extract organotins in water were at pH 5, with extraction and derivatization simultaneously at 45 degrees C for 30 min in a 2% sodium tetraethylborate solution and a sample solution volume in the ratio of 1:1, and desorption in the splitless injection port of the GC at 260 degrees C for 2 min. Detection limits are determined to be in the low ng/L range. According to the analysis, the linearity range is from 10 to 10,000 ng/L with R.S.D. values below 12% except triphenyltin (24%). The proposed method was tested by analyzing surface seawater from the harbors on the Taiwanese coast for organotins residues. Some organotins studied were detected in the analyzed samples. Results of this study demonstrate the adequacy of the headspace SPME-GC-MS method for analyzing organotins in sea water samples.  相似文献   

12.
Tsao YC  Wang YC  Wu SF  Ding WH 《Talanta》2011,84(2):406-410
The rapid and solvent-free determination of organophosphate esters (OPEs) in aqueous samples via one-step microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) analysis is described. Tri-n-butyl phosphate (TnBP) and tris-(2-ethylhexyl) phosphate (TEHP) were selected as model compounds for the method of development and validation. The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes, in a 20 mL water sample (in a 40 mL sample bottle containing 2 g of NaCl, pH 3.0), were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 140 W for 5 min. The limits of quantification (LOQs) for TnBP and TEHP were 0.5 and 4 ng/L, respectively. Using the standard addition method, MA-HS-SPME coupled with GC-MS was utilized to determine selected OPEs in surface water and wastewater treatment plants (WWTP) influent/effluent samples. Preliminary results show that TnBP was commonly detected OPEs in these aqueous samples, the correlation coefficients (r2) of the standard addition curves were greater than 0.9822, indicating that the developed method appears to be a good alternative technique for analyzing OPEs in aqueous samples.  相似文献   

13.
A solid-phase microextraction (SPME) method has been developed for the determination of 3 chloroacetanilide herbicides in both fresh and seawater samples. The extracted sample was analyzed by gas chromatography with mass spectrometry detection (GC-MS), and parameters affecting SPME operation including fibre type, sample pH, sample temperature, mixing speed and extraction time have been evaluated and optimized. The amount of dissolved organic matter (DOM) and the salt content both affected SPME extraction efficiency, but the presence of other competitive extractants such as organochlorine pesticides (OCPs) in the matrix showed no insignificance interference. The limit of detection (LOD) for acetochlor, metolachlor and butachlor were 1.2, 1.6 and 2.7 ng L−1, respectively. The recoveries for the herbicides ranged from 79 to 102%, and the linear dynamic range was from 10 to 1000 ng L−1. The developed method has been used to monitor herbicides contaminations in coastal water samples collected around Laizhou bay and Jiaozhou bay in Shandong peninsula, China. The concentrations of acetochlor and metolachlor ranged from undetectable to 78.5 ng L−1 and undetectable to 35.6 ng L−1, respectively. Butachlor was not observed but in only one sample and the concentration is lower than the limit of quantification (LOQ). The concentrations of the three herbicides in this study are low compared to most of the other places reported.  相似文献   

14.
A suitable analytical procedure based on static headspace solid-phase microextraction (SPME) followed by thermal desorption gas chromatography-ion trap mass spectrometry detection (GC-(ITD)MS), was developed and applied for the qualitative and semi-quantitative analysis of volatile components of Portuguese Terras Madeirenses red wines. The headspace SPME method was optimised in terms of fibre coating, extraction time, and extraction temperature. The performance of three commercially available SPME fibres, viz. 100 mum polydimethylsiloxane; 85 mum polyacrylate, PA; and 50/30 mum divinylbenzene/carboxen on polydimethylsiloxane, was evaluated and compared. The highest amounts extracted, in terms of the maximum signal recorded for the total volatile composition, were obtained with a PA coating fibre at 30 degrees C during an extraction time of 60 min with a constant stirring at 750 rpm, after saturation of the sample with NaCl (30%, w/v). More than sixty volatile compounds, belonging to different biosynthetic pathways, have been identified, including fatty acid ethyl esters, higher alcohols, fatty acids, higher alcohol acetates, isoamyl esters, carbonyl compounds, and monoterpenols/C(13)-norisoprenoids.  相似文献   

15.
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.  相似文献   

16.
A new hyphenated technique couples supercritical fluid extraction in situ derivatization and on-line headspace solid-phase microextraction to gas chromatography-mass spectrometry (SFE in situ derivatization on-line HS-SPME-GC-MS) for the determination of paraben preservatives and polyphenolic antioxidants in cosmetics. The preservatives and antioxidants were extracted from the cosmetic matrices with supercritical carbon dioxide at a pressure of 13,840 kPa. The supercritical fluid extraction was performed at 55 °C for 10 min of static extraction then 15 min of dynamic extraction. The extractant subsequently was derivatized in situ with the silylation reagent N,O-bis(trimethylsilyl)trifluoroacetamide with 0.1% trimethylchlorosilane. The product was then adsorbed on a polyacrylate solid-phase microextraction (SPME) fiber in the headspace. Sea sand was used as a dispersive material in the SFE step. The analytical linear ranges for the preservatives and antioxidants were found to be from 10 to 1000 ng g−1 with RSD values below 7.8%. The detection limits ranged from 0.5 to 8.3 ng g−1. These results are better than those obtained by using only SPME or SFE for trace preservatives and antioxidants analysis in cosmetic matrices. The new method was successfully utilized to determine the amounts of preservatives and antioxidants in real cosmetics without the need for tedious pretreatments.  相似文献   

17.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

18.
Headspace single drop microextraction coupled to gas chromatography-mass spectrometry yielded a simple, fast and virtually solventless analytical protocol used for the headspace analysis of aqueous samples contaminated with methylcyclopentadienyl-manganese tricarbonyl (MMT). Initially, several experimental parameters were controlled and optimized and the optimum conditions found were 2.5 μl octane microdrop exposed for 20 min to the headspace of a 10 ml aqueous sample (15 ml vial) containing 20% (w/v) NaCl and stirred at 1250 rpm. The calculated calibration curves gave a high level of linearity for MMT with correlation coefficients >0.9995 after conducting a 3-day study. The limit of detection was calculated to be 0.21 μg l−1. The proposed method achieved an enrichment factor of the order of 2100 and a 53% recovery after extracting the spiked aqueous solution for 20 min under the optimized experimental conditions. The repeatability and intra-day reproducibility of the proposed method, expressed as relative standard deviation were 8.4 and 6.4%, respectively. Finally, analysis of spiked tap and wastewater samples revealed that matrix had little effect upon extraction.  相似文献   

19.
A novel sorbent, dihydroxylated polymethylmethacrylate (DHPMM), coated on hollow-fiber membrane, is used for the polymer-coated hollow-fiber microextraction of trace amounts of natural and synthetic estrogens, such as diethylstilbestrol, estrone, 17beta-estradiol and 17alpha-ethynylestradiol, in aqueous samples. In this procedure, estrogens were extracted using the functionalized polar DHPMM polymer with derivatization using N-methyl-N-(trimethylsilyl)trifluoroacetamide followed by gas chromatography-mass spectrometric analysis. The detection limits for estrogens in aqueous sample were between 0.03 and 0.8 ng l(-1) and the calibration curves were linear over the concentration range 0.05-10 microgl(-1) and had correlation coefficients of >0.994. The relative standard deviations (RSDs) were <15% (n = 3). This simple, accurate, sensitive and selective analytical method is applicable to the determination of trace amounts of estrogens in reservoir and potable water samples.  相似文献   

20.
A simple, economical and very effective method is demonstrated for simultaneous determination of 2,4-dichlorophenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol and pentachlorophenol, in aqueous samples, by using purge-assisted headspace solid-phase microextraction (PA/HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). In the new method, purging the sample enhances the removal of the trace chlorophenols without derivatization from the matrices to the headspace. Extraction parameters including extraction temperature, purge gas flow rate and extraction time were systematically investigated. Under optimal conditions, the relative standard deviations (RSDs) were 4-11% at 50 pg/mL and 5-14% at 5 pg/mL, respectively. The recoveries were in the range of 83-114%. Detection limits were determined at the fg level. These results indicate that PA/HS-SPME provides a significant contribution to highly efficient extraction of semi-volatile CPs, especially for pentachlorophenol, which has the smallest Henry's constant and large octanol-water partitioning coefficient. In addition, the proposed method was successfully applied to the analysis of chlorophenols in landfill leachate. New perspectives are opened for headspace extraction of relatively low vapor pressure compounds in complex matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号