1.
曹军  洪芳军  郑平 《色谱》2007,25(4):482-485
毛细管电泳样品电堆积富集是一种通过缓冲溶液浓度的差异在毛细管中形成电场强度梯度,从而对样品进行浓缩的富集技术。本文在已有数学模型的基础上,对影响毛细管电堆积富集过程的因素进行了分析。计算结果发现,样品粒子表面所带的电荷电性以及带电量会影响粒子的电泳速度,进而影响富集过程;外加电势的大小会影响样品粒子到达检测窗口的迁移时间;而样品塞的初始长度则会影响样品所能达到的最大富集浓度以及达到最佳的富集效果所需要的时间。所得到的结果对样品电堆积富集技术的进一步完善具有一定的理论指导意义。  相似文献   

2.
Cao C  Zhang W  Fan L  Shao J  Li S 《Talanta》2011,84(3):651-658
The condensation of low abundance zwitterion substance, such as protein and peptide, has great significance to the study on proteomics. This paper develops the theory on design of online stacking conditions of zwitterion by a moving reaction boundary (MRB) in capillary electrophoresis (CE). This concerns the choice of running and sample buffers, velocity design of MRB, and salt effect on the stacking. The theoretical results unveil that: (1) the velocity of MRB formed with weak acidic buffer and strong alkali should be set between zero and the velocity of zwitterion in the alkali phase, or no stacking occurs; (2) if a strong alkali is used to prepare the sample, a much long front plug of strong base must be injected before the alkaline sample plug for complete stacking, whereas no such front plug is needed if a weak alkali with enough high concentration and pH value is used to prepare the sample buffer; (3) the existence of salt in sample matrix has a weak effect on the stacking of zwitterion if sample is prepared with weak alkaline buffer, while has a dramatic effect on the same stacking if with a strong base buffer. In addition, the concentration of weak alkali used for preparation of sample should be set at the point, at which the velocity of MRB is as much as possible close to that of negative zwitterion. The developed theory and its computation are quantitatively proved by the experiments of zwitterion stacking by the MRB as shown in the previous and the accompanying papers. The proposed theoretic results hold obvious significances on-column stacking of low abundance zwitterions, such as amino acid, or peptides or proteins, in CE.  相似文献   

3.
曹军  洪芳军  郑平 《色谱》2007,25(2):183-188
毛细管电泳样品电堆积富集过程可以浓缩样品组分,从而提高检测灵敏度,是一种有效的样品富集技术。本文通过合理的简化和假设,把毛细管中电堆积富集过程中所涉及的主要变量根据电势分布方程、缓冲溶液的浓度方程和样品粒子的质量传输方程进行耦合求解,建立了一个一维的数学模型,并应用有限元的方法对该模型进行了求解。计算结果给出了毛细管中缓冲溶液浓度及电场强度的分布随时间变化的过程,以及富集过程中毛细管中的电势分布曲线;得到了样品粒子浓度在电堆积富集过程和富集之后的再次扩散过程中的分布曲线以及正、负样品粒子的分离过程;最后分析了不同缓冲溶液浓度比对样品富集效果的影响。该研究为样品电堆积富集技术的进一步完善提供了一种简单可行的理论研究方法。  相似文献   

4.
Theory of field-amplified sample stacking (FASS) also called field-enhanced sample stacking is reevaluated considering the early work of Chien, Burgi and Helmer. The classical theory presented by Chien, Helmer and Burgi predicts the existence of maxima, which are ascribed to the counteracting principles of zone focusing and hydrodynamic dispersion. In contrast to their work, we here focus on cationic analytes separated in an acidic background electrolyte providing a very low electroosmotic flow velocity. Therefore, peak broadening due to differences in the local electroosmotic flow velocities in different compartments of the capillary can be regarded to be negligible. Consequently, peak broadening resulting from hydrodynamic dispersion will not be the dominant limitation of the accessible enrichment efficiency. In our experimental studies we, however, obtain an optimum value for the field enhancement factor (maximum of the enrichment efficiency, when varying the electric conductivity of the sample and the size of the sample injection plug) corresponding to a 10-fold dilution of the BGE in the sample solution. Comparing these experimental data with data modeled according to the revised theory, we show that this limitation of the loadability is caused by the unavoidable decrease of the analyte migration velocity in the BGE compartment of the capillary when injecting of a sample plug of lower electric conductivity (decrease in the local electric field strength). The additional diffusional band broadening limits the obtainable enrichment efficiency.  相似文献   

5.
A novel method for the on-column sample stacking of proteins is described. The strategy takes advantage of interactions between protein molecules and sodium dodecyl sulfate (SDS) monomers. A long plug of a protein sample (either acidic or basic) is injected into a capillary filled with a background electrolyte (BGE) containing SDS. When a potential is applied, the proteins interact with SDS monomers in the BGE to form protein-SDS complexes that migrate more slowly than the corresponding uncomplexed protein, resulting in protein stacking. Both acidic and basic proteins migrate at an almost identical electrophoretic velocity after stacking, which indicates that the protein-SDS complexes formed in the BGE zone have a similar charge/mass ratio. The mechanism of stacking was investigated using a sample consisting of a basic protein, lysozyme, and a small molecule, methylene blue. The findings clearly show that two interactions with SDS occur, a stepwise binding interaction between protein molecules and SDS monomers and an interaction in which the small molecules enter into micelles formed by SDS molecules. The method was also applied to the detection of a protein labeled with a fluorescent labeling reagent at trace levels. The labeled protein was detected even under labeling conditions where the labeling efficiency was too low to detect by short-plug injection.  相似文献   

6.
Liu S  Li Q  Chen X  Hu Z 《Electrophoresis》2002,23(19):3392-3397
A simple and rapid capillary zone electrophoresis method was developed for the separation of the main alkaloids from Sophora flavescens Ait. with the optimum buffer solution containing 110 mM NaH(2)PO(4) and 15% 2-propanol (pH 3.0). The field-amplified sample stacking (FASS) technique was applied to the on-line concentration of the alkaloids. The data presented in this work demonstrate that the use of a short water plug at the column inlet is essential for improving the reproducibility of FASS with electro-injection, and that the water plug injection time affected the sensitivity significantly. The sample concentration was further increased by about 2-3-fold by the introduction of a relatively longer water plug. With this stacking measure, the concentration sensitivity was about 3-4 orders of magnitude higher than in hydrodynamic injection.  相似文献   

7.
Zhang W  Fan L  Shao J  Li S  Li S  Cao C 《Talanta》2011,84(2):547-557
To demonstrate the theoretic method on the stacking of zwitterion with moving reaction boundary (MRB) in the accompanying paper, the relevant experiments were performed. The experimental results quantitatively show that (1) MRB velocity, including the comparisons between MRB and zwitterionic velocities, possesses key importance to the design of MRB stacking; (2) a much long front alkaline plug without sample should be injected before the sample injection for a complete stacking of zwitterion if sample buffer is prepared with strong base, conversely no such plug is needed if using a weak base as the sample buffer with proper concentration and pH value; (3) the presence of salt in MRB system holds dramatic effect on the MRB stacking if sample solution is a strong base, but has no effect if a weak alkali is used as sample solution; (4) all of the experiments of this paper, including the previous work, quantitatively manifest the theory and predictions shown in the accompanying paper. In addition, the so-called derivative MRB-induced re-stacking and transient FASI-induced re-stacking were also observed during the experiments, and the relevant mechanisms were briefly demonstrated with the results. The theory and its calculation procedures developed in the accompanying paper can be well used for the predictions to the MRB stacking of zwitterion in CE.  相似文献   

8.
JP Quirino  AT Aranas 《Electrophoresis》2012,33(14):2167-2175
In this paper, by injecting a SDS micellar plug before the sample prepared in aqueous organic solvents, we show the on-line sample preconcentration of cations via micelle to solvent stacking (MSS) using solvents of as low as 30%. This extends the choice of stacking techniques to include moderate amounts of organic solvent in the sample. The approach is akin to in-line solid phase extraction where the micellar plug acted as a transient micellar phase extractor. Basic studies were conducted (e.g. type and amount of organic solvent in the sample). The calculated sensitivity enhancement factors based on LOD obtained for the six test antipsychotic drugs were from 41 to 68. The peak signals were linear (R2 > 0.99) from 0.2 to 10.0 μg/mL. The intraday and interday reproducibility (n = 10) for migration time, peak height, and corrected peak area were from 0.2 to 13.6%. The technique was also tested on spiked wastewater sample with minimal sample treatment (i.e. dilution and centrifugation).  相似文献   

9.
Law WS  Zhao JH  Li SF 《Electrophoresis》2005,26(18):3486-3494
Field-amplified sample stacking (FASS) is used to separate basic proteins in a poly-(vinyl alcohol)-coated bubble cell capillary. To our knowledge, this is the first paper describing the on-column stacking of proteins (as cations) using FASS in bubble cell capillary. The bubble cell capillary is fabricated using a one-step method. Cetyltrimethylammonium chloride is added into the running buffer to reverse the EOF and, thus, to pump the water plug out during the sample stacking step. The effect of the water plug lengths and sample injection durations were investigated and optimized. The results obtained were compared with those for the normal capillary without bubble cell in terms of resolution and sensitivity enhancement. Under the optimal condition, this method can improve the sensitivity of the peak areas ranging from 5000- to 26 000-fold. The RSDs (n = 5) of the migration time and peak area are satisfactory (less than 0.6 and 12%, respectively). Application of the capillary electrophoresis method with bubble cell, FASS, and UV detection thereby leads to the determination of these proteins at concentrations ranging from 3 to 10 ng/mL, based on a signal-to-noise ratio of 3:1.  相似文献   

10.
Jia Z  Lee YK  Fang Q  Huie CW 《Electrophoresis》2006,27(5-6):1104-1111
A mismatch in the EOF velocities between the sample zone and running buffer region is known to generate pressure-driven, parabolic flow profile of the sample plug in electrokinetic separation systems. In the present study, video fluorescence microscopy was employed to capture real-time dynamics of the sample plug (containing fluorescein as the probe molecule) in a discontinuous conductivity system within a glass microchip, in which the sample matrix consisted of a mixture of ACN and salt (NaCl), and the running buffer contained sodium cholate (SC) micelles as the pseudo-stationary phase (i.e., performing "ACN stacking" in the mode of MEKC). Upon application of the separation voltage, the video images revealed that zone narrowing and broadening of the probe molecules occurred as the sample plug headed toward the cathode during the initial time period, probably resulting in part from the stacking/sweeping, and destacking of the SC micelles at the boundaries between the sample zone and running buffer. Interestingly, a second sample zone narrowing event can be observed as the sample plug moved further toward the cathode, which could be attributed to the sweeping of the slower moving probe molecules by the faster moving SC micelles that originated from the anode. This phenomenon was studied as a function of pH, sample plug length, as well as the concentration of organic solvent and salt in the sample matrix. The data suggested that the presence of large amounts of an organic solvent (such as ACN or methanol) and salts in the sample matrix not only induces sample dispersion due to the formation of a pressure-driven (hydrodynamic) flow, but may also lead to the formation of a double sample zone narrowing phenomenon by altering the local EOF dynamics within the separation system.  相似文献   

11.
A transient micellar phase extractor using CTAB was described for the online sample concentration of various anionic analytes (drugs and herbicides) in CE. Stacking and separation was performed at neutral pH in coelectroosmotic flow in a hexadimethrine bromide coated fused‐silica capillary. A micellar plug (e.g. 10 mM CTAB) was injected prior to hydrodynamic injection of the analytes prepared in aqueous organic solvent (e.g. with 30% ACN). In the presence of an electric field, the micelles interacted with the anions inside the capillary. This was followed by selective analyte focusing via the mechanism of micelle to solvent stacking. The micelles acted as transient extractor because the stacking ends when the injected micelles completely migrated through the boundary between the sample and micellar plug. Fundamental studies were performed (effect of surfactant concentration, etc.) and the technique yielded 13‐ to 30‐fold improvements in peak height. A stacking CE method in conjunction with liquid–liquid extraction was also tested for the detection of the herbicides fenoprop and mecoprop in fortified drinking water at analyte concentration levels relevant to Australian Drinking Water Guidelines.  相似文献   

12.
A capillary electrophoresis method with UV-absorbance detection was studied and optimized for the determination of underivatized amino acids in urine. To improve concentration sensitivity the utility of in-capillary analyte stacking via dynamic pH junction was investigated with phenylalanine (Phe) and tyrosine (Tyr) as model amino acids. Before sample injection, a plug of ammonium hydroxide solution was injected to enable analyte concentration. Samples were 1:1 (v/v) mixed with background electrolyte (1 M formic acid) prior to injection. The effect of the injected sample volume, and the injected ammonium hydroxide volume and concentration on analyte stacking and separation performance was investigated. The optimal volume of ammonium hydroxide depended on the injected sample volume. Using a dynamic pH junction good resolution (1.4) was obtained for a sample injection volume of 10% of the capillary (196 nl) with Phe and Tyr dissolved in water. Limits of detection (LODs) were 0.036 and 0.049 μM for Phe and Tyr, respectively. For urine samples, the optimized procedure comprised a 1.7-nl injection of 12.5% ammonium hydroxide, followed by a 196-nl injection of urine spiked with Phe and Tyr. Satisfactory resolution was obtained and amino acid peak widths at half height were only 1.6 s indicating efficient stacking. Calibration plots for Phe and Tyr in urine showed good linearity (R(2) > 0.96) in the concentration range 10-175 μM, and LODs for Phe and Tyr were 0.054 and 0.019 μM, respectively. RSDs for peak area and migration time for Phe and Tyr were below 7.5% and 0.75%, respectively.  相似文献   

13.
Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of detection (LODs) ranged from 0.002 to 0.03 microg ml(-1) using only the on-line preconcentration procedures without any off-line concentration of the extract. A solid-phase extraction (SPE) procedure, for previous isolation and concentration of the analytes, was used in combination with any of the proposed on-line preconcentration strategies, which achieves the determination of pesticides at limits of quantification (LOQs) lower than 0.01 mg kg(-1). The recoveries obtained by SPE in samples spiked at 0.01 mg kg(-1) were between 70 and 100%, with RSDs between 10 and 18% using SRMM. Samples of fruits and vegetables were taken from the market, extracted by the proposed procedure and analyzed with RM-MEKC with the on-line strategies.  相似文献   

14.
When using capillary electrophoresis (CE) for the analysis of biological samples, it is often necessary to employ techniques to overcome peak-broadening that results from having a high-conductivity sample matrix. To improve the concentration detection limits and separation efficiency of cationic pharmaceuticals in CE, pH-mediated acid stacking was performed to electrofocus the sample, improving separation sensitivity for the analyzed cations by 60-fold. However, this method introduces a large titrated acid plug into the capillary. To overcome the limitations this low-conductivity plug poses to stacking, the plug was removed prior to the separation step by applying reverse pressure to force it out of the anode of the capillary. Employing this technique allows for roughly twice the volume of sample to be injected. A maximum sample injection time of 240 s was attainable with baseline peak resolution compared to a maximum sample injection time of 120 s without reverse pressure, leading to a twofold decrease in the limits of detection of the analytes used. Separation efficiency overall is also improved when utilizing the reverse pressure step. For example, a 60 s sample injection time results in 94,000 theoretical plates as compared to 60,500 theoretical plates without reverse pressure. This reverse-pressure method was used for detection and quantitation of several cationic pharmaceuticals that were prepared in Ringer's solution to simulate microdialysis sampling conditions.  相似文献   

15.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

16.
Xu Y  Qin W  Lau YH  Li SF 《Electrophoresis》2005,26(18):3507-3517
This report describes a novel online field-amplified sample stacking (FASS) procedure to analyze 16 chlorinated acid herbicides. By using a poly(vinyl alcohol) (PVA)-coated capillary to reduce electroosmotic flow and introducing a methanol-water plug before sample loading, the sample injection time could be very long without loss of sample and separation efficiency. Under the optimized condition, the FASS procedure could provide great sensitivity enhancement (5000-10 000-fold) and satisfactory reproducibility (relative standard deviations of migration times less than 2.4%, relative standard deviations of peak areas less than 8.0%). Combined with cationic surfactant-assisted solid-phase extraction (CSA-SPE), the limit of detection of the herbicides ranged from 0.269 to 20.3 ppt, which are two orders lower than those of the US Environmental Protection Agency standard method 515.1. The CSA-SPE-FASS-CE method was successfully applied to the analysis of local pond water.  相似文献   

17.
T Hirokawa  H Okamoto  N Ikuta 《Electrophoresis》2001,22(16):3483-3489
Operational modes for transient isotachophoretic preconcentration capillary zone electrophoresis (tr-ITP-CZE) were studied by using 5 microM and 0.5 microM rare earth mixtures as analytes in comparison with field-enhanced sample stacking. After examination of several operational modes for tr-ITP, it was found that tr-ITP effectively occured even if both the leading electrolyte and the terminating electrolyte were injected after the sample plug. This was explained as the result of a field-enhanced stacking for both sample components and the leading and terminating ions. The observed theoretical plate numbers were 4-20 times higher than those obtained by normal stacking; and the estimated low limit of detectable concentration of rare-earth elements (REE) was ca. 0.1 microM which was 2.5 times lower compared to normal stacking. For the 0.5 microM sample, a concentration factor of 20 000 could be achieved after only tr-ITP.  相似文献   

18.
Sample stacking can occur in isoconductive buffer systems as a result of ion transport mismatches that cause changes in buffer conductivity during electrophoresis. Fluorescence imaging was used to examine this effect in the sweeping of hydrophobic dyes with sodium dodecyl sulfate (SDS) on microchips. Imaging revealed the occurrence of a stacking effect in a sodium borate buffer system in which the sample buffer and SDS-containing run buffer had the same initial conductivity. Injected sample plugs were first swept by SDS micelles and the swept band was then stacked at the trailing end of the sample zone. This effect is due to changes in conductivity at both the front and back interfaces of the injected sample plug and can be modeled by moving boundary equations. Maximum signal enhancements of 86-, 160- and 560-fold were obtained for Rhodamine 560, Rhodamine B and Rhodamine 6G, respectively, by the combination of sweeping and stacking within a 1 cm section of microchannel. Based on sample sweeping/stacking and manipulation of the electric field polarity, a method of trapping and concentrating analyte from multiple injections was also demonstrated.  相似文献   

19.
This paper describes approaches for stacking large volumes of sample solutions containing a mixture of chlorophenols and chlorophenoxyacetic acids as their anions in capillary zone electrophoresis, and compares results to standard capillary electrophoresis (CE) and normal stacking modes. In order to increase the amount of sample injected beyond the optimal conditions and maintain high resolution, the sample introduction buffer must be removed after the stacking process is completed. This is achieved by pumping the sample buffer out of the column using polarity switching. Large sample volumes are loaded by hydrodynamic injection, then stacked at the injection buffer/run electrolyte interface, followed by the removal of the large plug of low-conductivity sample matrix from the capillary column using polarity switching and finally the separation of the stacked anions in a basic buffer (pH 8.65). Around 10- and 40-fold improvement of sensitivity was achieved by normal stacking and large-volume stacking with polarity switching, respectively, when compared to the standard CE analysis. Sweeping-micellar electrokinetic capillary chromatography (MEKC) was also investigated for the purpose of comparison to the stacking technique. The method should be suitable for the analysis of these chemical compound classes in industrial chlorophenoxyacetic acid manufacture.  相似文献   

20.
During some capillary zone electrophoresis (CZE) experiments, the baseline UV absorbance signal at 200 nm “jumped” from one stable level prior to the water plug (marking the flow of neutrals) to another stable level after the water plug. The phenomenon was further examined with distilled water as the sample and with different buffers, applied potentials, and salt concentrations in the buffer. It seems that there is an “isotachophoretic effect” on top of the CZE separations when running under stacking conditions. The effect results in a higher pH value of the buffer after the water plug compared to the pH prior to the plug. The nature of the buffer, the salt concentration in the buffer, and the applied potential all affect this phenomenon.  相似文献   