首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To investigate diffusion-weighted (DWI) and dynamic contrast-enhanced MR imaging (DCE-MRI) as early response predictors in cervical cancer patients who received concurrent chemoradiotherapy (CCRT).

Materials and methods

Sixteen patients with cervical cancer underwent DWI and DCE-MRI before CCRT (preTx), at 1 week (postT1) and 4 weeks (postT2) after initiating treatment, and 1 month after the end of treatment (postT3). At each point, apparent diffusion coefficient (ADC) and DCE-MRI parameters were measured in tumors and gluteus muscles (GM). Tumor response was correlated with imaging parameters or changes in imaging parameters at each point.

Results

At each point, ADC, Ktrans and Ve in tumors showed significant changes (P < 0.05), as compared with those of GM (P > 0.05). PostT1 tumor ADCs showed a significant correlation with tumor size response at postT2 (P = 0.041), and changes in tumor ADCs at postT1 had a significant correlation with tumor size (P = 0.04) and volume response (P = 0.003) at postT2. In tumors, preTx Ktrans and Ve showed significant correlations with tumor size at postT3 (P = 0.011) and tumor size response at postT2 (P = 0.019), respectively.

Conclusion

DWI and DCE-MRI, as early biomarkers, have the potential to evaluate therapeutic responses to CCRT in cervical cancers.  相似文献   

2.
3.
Proton NMR spectra of perchloric acid extracts of methyl cholantherene induced tumors grown in rats have been analyzed and compared with the normal and the treated tumor tissue samples. Well-resolved resonances from numerous low-molecular weight compounds including various amino acids, nucleotides, choline, creatine, phosphocreatine etc. were observed and assigned using pH titration, 2D NMR and by comparison with the spectra of model compounds. Significant differences were noticed in the spectra of the tumor and the normal tissue samples. Ratios of metabolite levels were calculated for the normal, tumor and treated tumor tissues which are shown as good markers to assess the state of the tumor and their response to treatment.  相似文献   

4.
Previous studies of renal stone disease (RSD) in Thailand indicated abnormal urinary aggregator and inhibitor composition among farmers with excessive sweat loss. Our aim was to compare the proton MR spectra obtained from the kidneys of 32 proven cases of RSD (aged 38 to 65 yrs) with nine age-matched normal control subjects. We used the STEAM sequence with TE = 15 ms and TR = 2000 ms. The spectra at 3.25, 3.6 and 3.9 ppm were analyzed. The results showed a correlation between the three peaks (p < 0.001), however, there was no significant difference between the RSD group and the normal control subjects. We therefore concluded that there was no overloading of these osmolytes among the renal stone patients.  相似文献   

5.
PURPOSE: Central neurocytomas (CNCs) are rare neuronal tumors that have a favorable prognosis and lower rate of recurrence compared with other intraventricular neoplasms. Although it may be difficult to distinguish CNC on conventional neuroimaging, typical MR spectroscopy (MRS) features have been reported. We describe the MRI and MRS features of CNC. MATERIALS AND METHODS: Eight patients with CNC were reviewed. Three patients underwent presurgical in vivo single-voxel MRS at short echo time (TE, 35 ms) and multi-voxel MR spectroscopic imaging at long TE (144 ms). The surgically resected tumor specimen of one of these patients was also studied ex vivo using high-resolution magic angle spinning (HRMAS) nuclear magnetic resonance. RESULTS: All eight tumors were located in the lateral ventricles. In six patients, CNC extended into the third ventricle, and in two patients the tumor showed further contiguous intraventricular dissemination into the fourth ventricle. In all three patients who underwent MRS, a characteristic metabolite peak was detected at 3.55 parts per million (ppm) at both long and short TE. HRMAS confirmed the presence of elevated glycine (Gly) at 3.55 ppm, without increase in the concentration of myo-inositol found at the same chemical shift. Elevated choline (at 3.2 ppm) was also seen in all three patients. CONCLUSION: On MRS, CNCs have a typical appearance with a metabolite peak at 3.55 ppm due to increased Gly, and this feature may be helpful in presurgical diagnosis. Although they are rare benign intraventricular tumors, in atypical cases, CNCs can show extensive intraventricular dissemination into the fourth ventricle.  相似文献   

6.

Background and Purpose

Human immunodeficiency virus (HIV)-associated dementia (HAD) has been extensively studied using magnetic resonance spectroscopy (MRS) at field strengths of 1.5 T. Higher magnetic field strengths (such as 3 T) allow for more reliable determination of certain compounds, such as glutamate (Glu) and glutamine (Gln). The current study was undertaken to investigate the utility of 3-T MRS for evaluating HIV+ patients with different levels of cognitive impairment with emphasis on the measurement of Glu and Glx (the sum of Glu and Gln).

Methods

Eighty-six HIV+ subjects were evaluated at 3 T using quantitative short echo time single-voxel MRS of frontal white matter (FWM) and basal ganglia (BG). Subjects were divided into three groups according to the Memorial Sloan Kettering (MSK) HIV dementia stage: 21 had normal cognition (NC) (MSK 0), 31 had mild cognitive impairment (MCI) without dementia (clinical MSK stage=0.5), and 34 had dementia (HAD) (MSK≥1). HIV+ subjects had also undergone standardized cognitive testing covering the domains of executive function, verbal memory, attention, information processing speed and motor and psychomotor speed. Between-group differences in metabolite levels in FWM and BG were evaluated using ANOVA. Pearson correlation coefficients were used to explore the associations between the Glu and Glx metabolites and neurocognitive results.

Results

FWM Glx was lower in HAD (8.1±2.1 mM) compared to both the MCI (9.17±2.1 mM) and NC groups (10.0±1.6 mM) (P=.006). FWM myo-inositol (mI) was higher in HAD (4.15±0.75 mM) compared to both MCI (3.86±0.85 mM) and NC status (3.4±0.67 mM) (P=.006). FWM Glx/creatine (Cr) was lower and FWM mI/Cr was significantly higher in the HAD compared to the MCI and NC groups (P=.01 and P=.004, respectively). BG N-acetyl aspartate (NAA) was lower in the HAD group (6.79±1.53 mM), compared to the MCI (7.5±1.06 mM) and NC (7.6±1.01 mM) groups (P=.036). Significant negative correlations were observed between Glu, Glx and NAA concentrations with Trail-Making Test B (P=.006, P=.0001 and P=.007, respectively), and significant positive correlation was found with the Digit symbol test (P=.02, P=.002 and P=.008, respectively). FWM Glx and NAA concentrations showed negative correlation with Grooved Pegboard nondominant hand (P=.02 and P=.04, respectively).

Conclusion

Patients with HAD have lower levels of Glx concentrations and Glx/Cr ratio in FWM, which was associated with impaired performance in specific cognitive domains, including executive functioning, fine motor, attention and working memory performance. Three-Tesla MRS measurements of Glx may be a useful indicator of neuronal loss/dysfunction in patients with HIV infection.  相似文献   

7.
Brain alcohol was measured in rhesus monkeys (Macaca mulatta) by proton magnetic resonance spectroscopy (MRS) following acute nasogastric alcohol administration (0.8 g/kg). Monkeys were anesthetized with ketamine and xylazine. A 1.5 T whole body imager and a 3-inch surface coil were used to acquire TE 30 and 270 ms spectra from a 7.5 cc voxel localized with a stimulated echo (STEAM) sequence. Venous blood samples were collected during spectral acquisitions for gas chromatographic determination of temporally concordant blood alcohol levels (BALs). Acute alcohol administration did not alter the resonance areas of N-acetylaspartate/N-acetyl containing compounds (NAA), choline containing compounds, or total creatine. The NAA resonance was used as an internal standard to calculate approximate brain alcohol concentrations, which averaged 27 ± 3% and 27 ± 8% of temporally concordant BALs (T2-corrected TE 30 and TE 270 ms spectra, respectively). In addition to reconfirming results from prior studies finding incomplete detection of brain alcohol with MRS, these results demonstrate the feasibility of measuring brain alcohol in anesthetized nonhuman primates to examine relationships between alcohol exposure history and MRS-visibility of brain alcohol.  相似文献   

8.
Brain abscess observed by localized proton magnetic resonance spectroscopy   总被引:3,自引:0,他引:3  
We encountered a case of brain abscess that was difficult to differentiate from glioblastoma. Localized 1H-MRS was found to be useful for obtaining information on the biochemical status of brain abscess. The peak of lipid and high residual peak of NAA (N-acetyl-aspartate) were observed in the cystic lesion of the brain abscess by 1H-MRS. The NAA/Cho (Choline-containing compounds) ratio in brain parenchyma showing an edematous lesion before therapy gradually increased with the relief of inflammation.  相似文献   

9.
We wish to report the detection of dimethyl sulfone (methylsulfonylmethane, C2H6O2S) in the brain of a normal 62-year-old male using in vivo proton magnetic resonance spectroscopy. The presence of this exogenous metabolite resulted from ingestion of a dietary supplement containing dimethyl sulfone. The concentration of this compound in the brain was measured to be 2.4 mmol, with a washout "half life" of approximately 7.5 days. The in vivo T1 and T2 relaxation times of dimethyl sulfone were measured to be 2180 ms and 385 ms, respectively. The concentration of major brain metabolites, namely N-acetylaspartate, total Creatine and Choline, and myo-Inositol were within normal limits.  相似文献   

10.
Focused pathological evaluation of axillary lymph nodes in breast cancer is gaining importance. Nuclear magnetic resonance (NMR) spectroscopy that assesses the whole of the specimen has the potential in evaluating micrometastases. The biochemical changes associated with breast cancer metastases in axillary nodes by in vitro NMR and its use in the detection of axillary metastases in a clinical setting in comparison with conventional histopathology is presented in this study. Eighty-eight lymph nodes obtained from 30 patients with breast cancer were investigated. Histopathology revealed metastases in 20 nodes from 11 patients, while in vitro NMR spectroscopy revealed metastases in 22 nodes. Out of these 22 nodes, 16 were the same, which showed metastases on histopathology, while 6 nodes have shown metastases only on in vitro magnetic resonance spectroscopy (MRS). These 6 nodes with suspicion of metastases on MRS were subjected to reevaluation with serial sectioning and immunohistochemistry, but no additional metastases were revealed. Forty metabolites could be identified from the MR spectrum of lymph nodes. The levels of the glycerophosphocholine-phosphocholine (GPC-PC), choline, lactate, alanine and uridine diphosphoglucose were elevated significantly in nodes with metastases. In addition, the intensity ratio of GPC-PC/threonine (Thr) was higher in nodes with metastases, and using this as marker, MRS detected the axillary metastases with a sensitivity, specificity and accuracy of 80%, 91% and 88%, respectively. Neoadjuvant chemotherapy (NACT) lowered the concentrations of GPC-PC and GPC-PC/Thr ratio. The accuracy of MRS in detecting metastases was 75% in patients who received NACT (n=9) as compared to 96% in those who did not (n=21). Our results demonstrate the potential of in vitro MRS in characterizing the metabolite profile of the axillary nodes with breast cancer metastases. It detected axillary metastases with reasonable accuracy and can be complementary to histopathological evaluation and immunohistochemistry.  相似文献   

11.

Objective

To determine whether metabolite ratios in multivoxel 3D proton MR spectroscopy (1H MRS) is different between low-grade and high-grade gliomas and may be useful for glioma grading.

Materials and Methods

Thirty-nine patients (23 male and 16 female; 22-75 years old; mean age, 44.92±12.65 years) suspected of having gliomas underwent 3D 1H MRS examinations. Metabolite ratios [choline (Cho)/creatine (Cr), N-acetylaspartate (NAA)/Cr and Cho/NAA] were measured. Tumor grade was determined by using the histopathologic grading. Receiver operating characteristic analysis of metabolite ratios was performed, and optimum thresholds for tumor grading were determined. The resulting sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for identifying high-grade gliomas were calculated.

Results

Diagnostic-quality 3D 1H MRS with readily quantifiable Cho, Cr and NAA peaks was obtained in 94.87% of the cases. The Cho/Cr and Cho/NAA ratios were significantly higher in high-grade than in low-grade glioma (P<.001), whereas the NAA/Cr ratios were significantly lower in high-grade than in low-grade glioma (P<.001). Receiver operating characteristic analysis demonstrated a threshold value of 2.04 for Cho/Cr ratio to provide sensitivity, specificity, PPV and NPV of 84.00%, 83.33%, 91.30% and 71.43%, respectively. Threshold value of 2.20 for Cho/NAA ratio resulted in sensitivity, specificity, PPV and NPV of 88.00%, 66.67%, 84.62% and 72.73%, respectively. Overall diagnostic accuracy was not statistically significantly different between Cho/Cr and Cho/NAA ratios (χ2=0.093, P=.76).

Conclusion

Metabolite ratios of low-grade gliomas were significantly different from high-grade gliomas. Cho/Cr and Cho/NAA ratios could have the superior diagnostic performance in predicting the glioma grade.  相似文献   

12.

Purpose

To present proton magnetic resonance spectroscopy and diffusion-weighted imaging (DWI) findings of central neurocytoma (CN).

Methods and Materials

Imaging findings of seven patients with the histopathological diagnosis of CN (five male and two female; age range, 21–28 years of age) were evaluated retrospectively. In addition to conventional magnetic resonance imaging features, we also assessed the metabolite ratios and tumor normalized apparent diffusion coefficient (NADC), which was calculated by dividing the tumor apparent diffusion coefficient (ADC) values by normal ADC. Approval from our institutional review board was obtained for this review.

Results

The tumor choline/creatine ratios were 5.17±2.38, while N-acetyl aspartate/choline and N-acetyl aspartate/creatine ratios were 0.33±0.15 and 1.84±1.38, respectively. On DWI, tumors had heterogeneous hyperintense appearances when compared with the contralateral parietal lobe white matter and tumor NADC values were 0.63±0.05.

Conclusion

Significantly increased choline/creatine and decreased N-acetyl aspartate/choline ratios with lower NADC values in CN resemble high-grade gliomas and complicate the diagnosis. Familarity its physiologic features would help to presurgical diagnosis of ventricular and exraventricular CNs.  相似文献   

13.
While the inherent low sensitivity of in vivo MR spectroscopy motivated a trend towards higher magnetic fields, B(0), it has since become apparent that this increase does not seem to translate into the anticipated improvement in spectral resolution. This is attributed to the decrease of the transverse relaxation time, T(2)*, in vivo due to macro- and mesoscopic tissue susceptibility. Using spectral contrast-to-noise ratio (SCNR) arguments, we show that if in biological systems the linewidth (on the frequency scale) increases linearly with the field, the spectral resolution (in parts per million) improves approximately as the fifth-root of B(0) for chemically shifted lines and decreases as about B(0)(4/5) (in hertz) for a structure of J-coupled multiplets. It is also shown that for any given B(0) there is a unique voxel size that is optimal in spectral resolution, linking the spectral and spatial resolutions. Since in practical applications the spatial resolution may be dictated by the target anatomy, nomograms to determine the B(0) required to achieve the desired spectral resolution at that voxel size are presented. More generally, the scaling of the nomograms to determine the achievable spectral and spatial resolutions at any given field is described.  相似文献   

14.

Purpose

To develop a post-processing, respiratory-motion correction algorithm for magnetic resonance spectroscopy (MRS) of the liver and to determine the incidence and impact of respiratory motion in liver MRS.

Materials and Methods

One hundred thirty-two subjects (27 healthy, 31 with nonalcoholic fatty liver disease and 74 HIV-infected with or without hepatitis C) were scanned with free breathing MRS at 1.5 T. Two spectral time series were acquired on an 8-ml single voxel using TR/TE=2500 ms/30 ms and (1) water suppression, 128 acquisitions, and (2) no water suppression, 8 acquisitions. Individual spectra were phased and frequency aligned to correct for intrahepatic motion. Next, water peaks more than 50% different from the median water peak area were identified and removed, and remaining spectra averaged to correct for presumed extrahepatic motion. Total CH2+CH3 lipids to unsuppressed water ratios were compared before and after corrections.

Results

Intrahepatic-motion correction increased the signal to noise ratio (S/N) in all cases (median=11-fold). Presumed extrahepatic motion was present in 41% (54/132) of the subjects. Its correction altered the lipids/water magnitude (magnitude change: median=2.6%, maximum=290%, and was >5% in 25% of these subjects). The incidence and effect of respiratory motion on lipids/water magnitude were similar among the three groups.

Conclusion

Respiratory-motion correction of free breathing liver MRS greatly increased the S/N and, in a significant number of subjects, changed the lipids/water ratios, relevant for monitoring subjects.  相似文献   

15.
This paper presents new results for the normal, malignant and benign tissues by Raman spectroscopy. To the best of our knowledge, this is one of the most statistically reliable research (321 spectra from 44 patients) on Raman spectroscopy-based diagnosis of breast cancers among the world's women population. The paper demonstrates that Raman spectroscopy is a powerful medical diagnostic tool with the key advantage in breast cancer research.  相似文献   

16.
Off-resonance or spillover irradiation and incomplete saturation can introduce significant errors in the estimates of chemical rate constants measured by saturation-transfer magnetic resonance spectroscopy (MRS). Existing methods of correction are effective only over a limited parameter range. Here, a general approach of numerically solving the Bloch-McConnell equations to calculate exchange rates, relaxation times and concentrations for the saturation-transfer experiment is investigated, but found to require more measurements and higher signal-to-noise ratios than in vivo studies can practically afford. As an alternative, correction formulae for the reaction rate are provided which account for the expected parameter ranges and limited measurements available in vivo. The correction term is a quadratic function of experimental measurements. In computer simulations, the new formulae showed negligible bias and reduced the maximum error in the rate constants by about 3-fold compared to traditional formulae, and the error scatter by about 4-fold, over a wide range of parameters for conventional saturation transfer employing progressive saturation, and for the four-angle saturation-transfer method applied to the creatine kinase (CK) reaction in the human heart at 1.5 T. In normal in vivo spectra affected by spillover, the correction increases the mean calculated forward CK reaction rate by 6-16% over traditional and prior correction formulae.  相似文献   

17.
Localized proton-stimulated echo acquisition mode (STEAM) spectroscopy was performed in seven patients with benign prostatic hyperplasia (BPH), six patients with prostate cancer, and seven healthy volunteers to determine whether citrate levels detected using a saddle-type external-body surface coil (two loops of 13 cm ×17 cm) could reliably discriminate BPH from prostatic cancer. Relative area ratios of citrate level to choline plus creatine or citrate to lipid signal were compared with postoperative pathologic histology findings. The metabolic signals were well detectable as much as the line width of water resonance was ranging from 5 to 9 hz. Average SNRs of citrate in BPH and prostate cancer were 11.4 and 1.9, respectively. The major finding was consistently lower citrate levels in prostate cancer compared with BPH and normal prostate central gland. This was significantly (p < 0.01) reflected by lower mean citrate/[creatine+choline] peak area ratio and citrate/lipid peak area ratio observed for region of cancer (0.446 ± 0.063, 0.097 ± 0.030) compared with BPH (1.458 ± 0.107, 0.786 ± 0.162) and normal central gland (1.418 ± 0.129, 0.175 ± 0.011), respectively. These studies demonstrate the potential of citrate spectrum detected by an external-body surface coil as an in vivo marker for discriminating prostate cancer from BPH.  相似文献   

18.
Water-suppressed and slice-selective proton spectra of live human brain exhibited several resonances that were tentatively assigned to metabolites such as N-acetylaspartate, glutamate, phosphocreatine and creatine, choline derivatives, and taurine. In the liver spectrum of a healthy volunteer, the major resonance was tentatively assigned to a fatty acyl methylene and the minor resonances to protons in carnitine, taurine, glutamate, and glutamine. In the spectrum of a cancerous liver, resonances in addition to those present in the normal liver were seen. Protein degradation in the liver with cancer was indicated by resonances from urea and from the ring protons in tryptophan, tyrosine, and phenylalanine. Furthermore, increased nucleic acid synthesis was indicated by resonances from nucleotide protons.  相似文献   

19.
Proton magnetic resonance spectroscopy has the potential to provide valuable information about alterations in gamma-aminobutyric acid (GABA), glutamate (Glu), and glutamine (Gln) in psychiatric and neurological disorders. In order to use this technique effectively, it is important to establish the accuracy and reproducibility of the methodology. In this study, phantoms with known metabolite concentrations were used to compare the accuracy of 2D J-resolved MRS, single-echo 30 ms PRESS, and GABA-edited MEGA-PRESS for measuring all three aforementioned neurochemicals simultaneously. The phantoms included metabolite concentrations above and below the physiological range and scans were performed at baseline, 1 week, and 1 month time-points. For GABA measurement, MEGA-PRESS proved optimal with a measured-to-target correlation of R(2)=0.999, with J-resolved providing R(2)=0.973 for GABA. All three methods proved effective in measuring Glu with R(2)=0.987 (30 ms PRESS), R(2)=0.996 (J-resolved) and R(2)=0.910 (MEGA-PRESS). J-resolved and MEGA-PRESS yielded good results for Gln measures with respective R(2)=0.855 (J-resolved) and R(2)=0.815 (MEGA-PRESS). The 30 ms PRESS method proved ineffective in measuring GABA and Gln. When measurement stability at in vivo concentration was assessed as a function of varying spectral quality, J-resolved proved the most stable and immune to signal-to-noise and linewidth fluctuation compared to MEGA-PRESS and 30 ms PRESS.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏