首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The sorption of 14 metal ions on silica gel impregnated with a mixture of Aliquat 336 and Eriochrome Blue SE was investigated. It was found that the sorption behaviour depends upon the species and the pH of the loading solution. Alkali metal ions were not retained under any of the investigated conditions. The retained metal ions can be eluted with dilute solutions of hydrochloric or perchloric acid without significant elution of the chelating reagent from the sorbent. The sorbent was used for the separation of metal ion mixtures by column — extraction chromatography and for additional purification of some salt solutions from trace amounts of Zn, Cd, Pb and Cu. The effectiveness of purification was confirmed by anodic stripping voltammetry.  相似文献   

2.
 Acid Red 88 is strongly extracted by chloroform solutions of Aliquat 336 by an ion exchange mechanism and for its reextraction from the ion pair formed, relatively high concentrations of mineral acids are required. By impregnation of silica with the ion pairs between the cation of Aliquat 336 and the anion of the dye a chelating sorbent for metal ions can be obtained. The sorbent prepared may be successfully used for separation of mixtures of various metal ions by the column extraction chromatography technique, additional purification of sodium and potassium salts from ions of heavy metals and for concentration of trace amounts of ions of various metals from aqueous solutions followed by their quantitative determination. The sorbent can be used repeatedly in the process of sorption and desorption of metal ions (especially those forming less stable complexes with the reagent) after regeneration with solutions of perchloric acid. Received January 28, 1998. Revision March 1, 1999.  相似文献   

3.
The chromatographic behavior of some alkaline-earth, transition, heavy, and rare-earth metals on a number of complexing sorbents containing surface iminodiacetic acid (IDA) functional groups is studied. The conditions under which metal retention is determined by complexation on the sorbent surface were established, and the main principles of a new variant of the liquid chromatography, i.e., high-performance chelation ion chromatography (HPCIC), are formulated. The efficiency and selectivity of separation of the metal ions are considered depending on the type of the IDA bonding, the sorbent matrix parameters, the eluent composition, and the temeprature of the chromatographic column. Under optimal conditions, the metal retention is shown to linearly correlate with the stability constants of the respective complexes in the double-logarithmic scale. The application of HPCIC to the analysis of multicomponent systems is considered.  相似文献   

4.
A silica gel sorbent loaded with sodium diethyldithiocarbamate has been developed for the preconcentration of lead, cadmium and zinc prior to their determination by flameatomic absorption spectrometry (FAAS). The sorption and desorption of the metal ions was studied under both static and dynamic conditions. The metal ions were quantitatively retained on the silica gel sorbent based on an equilibrium time of less than 1 min. In case of the batch method, the effects of pH, shaking time, amount of sorbent, and desorption time were investigated. Among the desorption agents studied, only EDTA in ammonium chloride/ammonia buffer yielded quantitative recoveries. Freundlich's sorption isotherms determined for each metal show that sufficient sorption ability is obtained. The column method allows the preconcentration of metal ions from large sample volumes (e.g. 200 mL) using a flow rate of 5 mL min–1. The influence of foreign ions present in natural waters and saline solutions was examined. The reproducibility of the total analytical method, expressed as relative standard deviation (RSD) is 1.8, 0.5 and 0.6%, for lead, cadmium and zinc, respectively.  相似文献   

5.
Savings in analysis time in capillary GC have always been an important issue for chromatographers since the introduction of capillary columns by Golay in 1958. In laboratories where gas chromatographic techniques are routinely applied as an analytical technique, every reduction of analysis time, without significant loss of resolution, can be translated into a higher sample throughput and hence reduce the laboratory operating costs. In this contribution, three different approaches for obtaining fast GC separations are investigated. First, a narrow-bore column is used under conventional GC operating conditions. Secondly, the same narrow-bore column is used under typical fast GC conditions. Here, a high oven temperature programming rate is used. The third approach uses a recent new development in GC instrumentation: Flash-2D-GC. Here the column is placed inside a metal tube, which is resistively heated. With this system, a temperature programming rate of 100°/s is possible. The results obtained with each of these three approaches are compared with results obtained on a column with conventional dimensions. This comparison takes retention times as well as plate numbers and resolution into consideration.  相似文献   

6.
The paper describes a new test designed in micellar LC (MLC) to compare the commercial C18 stationary phase properties. This test provides the total hydrophobicity, hydrophilicity, steric selectivity, hydrogen bonding, and ion‐exchange capacity properties calculation of the ODS stationary phases. Both the test compounds and chromatographic separation conditions choice for column characterization in MLC are detailed. The chromatographic performance of several stationary phases that are used in MLC was evaluated with specific chromatographic test comprising nine test compounds, possessing different physico‐chemical properties, which were injected on different supports with two micellar mobile phases: one at pH 7.0 (0.075 mol/L SDS and 1.5% v/v 1‐pentanol), and other at pH 2.7 (0.075 mol/L SDS and 1.5% v/v 1‐pentanol adjusted to pH by TFA). Fundamental column chromatographic properties were obtained under these conditions and were treated by hierarchical cluster analysis. From the results of cluster analysis, two closely related groups of columns are distinguished, and it was shown that the chosen column characteristic parameters allow characterizing both sorbent and micellar chromatographic system properties. Eleven columns were analyzed by this test, which allows a comparison of columns with the aim of the selection of suitable and analogous column for the analysis with MLC.  相似文献   

7.
Malla ME  Alvarez MB  Batistoni DA 《Talanta》2002,57(2):277-287
A chelating type ion exchange resin (Amberlite IRC-718), containing iminodiacetate groups as active sites, has been characterized regarding the sorption and subsequent elution of Cd, Zn and Pb, aiming to metal preconcentration from solution samples of different origins. The methodology developed is based on off-line operation employing mini columns made of the sorbent. The eluted metals were determined by flame atomic absorption spectrometry. The effect of column conditioning, influent pH and flow rate during the sorption step, and the nature of the acid medium employed for desorption of the retained metals were investigated. Working (breakthrough) and total capacities were measured under dynamic operating conditions and the results compared with those obtained with Chelex-100, a resin extensively employed for analytical preconcentration. Structural information on the complexation of metals by the chelating groups was obtained by Fourier Transform infrared spectrometry. The analytical response of the Amberlite sorbent was assessed for the analysis of water samples and digestates of marine sediments.  相似文献   

8.
A new flow injection (FIA) procedure for the preconcentration of cadmium in urine using multiwalled carbon nanotubes (MWCNT) as sorbent and posterior electrothermal atomization atomic absorption spectrometry (ETA-AAS) Cd determination has been developed. Cadmium was retained in a column filled with previously oxidized MWCNTs and it was quantitatively eluted with a nitric acid solution. The parameters influencing the adsorption-elution process such as pH of the sample solution, amount of sorbent and flow rates of sample as well as eluent solutions have been studied. Cd concentration in the eluent was measured by ETA-AAS under the optimized conditions obtained. The results indicated the elimination of urine matrix effect as a consequence of the preconcentration process performed. Total recovery of cadmium from urine at pH 7.2 using a column with 45 mg of MWCNTs as sorbent and employing a HNO3 0.5 mol L−1 solution for elution was attained. The detection limit obtained was 0.010 μg L−1 and the preconcentration factor achieved was 3.4. The method showed adequate precision (RSD: 3.4-9.8%) and accuracy (mean recovery: 97.4-100%). The developed method was applied for the determination of cadmium in real urine samples from healthy people (in the range of 0.14-2.94 μg L−1) with satisfactory results.  相似文献   

9.
A new type of capillary column for gas chromatography was proposed. A sorbent layer (for example, stationary liquid phase) is supported on the internal capillary surface, and the internal (interstitial) volume is packed with nonporous large particles of a sorbent (particle diameter is 0.1—0.6 of the capillary internal diameter). The external surface of the particles can also be coated with the sorbent layer (for example, stationary liquid phase). The specific separation efficiency (number of separation) on the new type column is by 1.6—2.3 times higher than that of the initial classical capillary column.  相似文献   

10.
A chelating sorbent obtained by adsorption of 1-(2-pyridylazo)-2-naphthol (PAN) on Amberlite XAD-2 was used for the preconcentration of Ga and In. The analytical characteristics of the chelating sorbent were investigated and optimun sorption conditions for these metals under dynamic conditions were established. A peristaltic pump is used to adjust the flow rate of the solution. Elements are collected from the column by using a mixture adjusted to a pH range of 4-7 and 6-12 by ammonia or ammonium chloride for Ga and In, respectively. The procedure developed was applied to the analysis of different ores.  相似文献   

11.
N. Wu  Q. Tang  Y. Shen  M. L. Lee 《Chromatographia》1999,49(7-8):431-435
Summary In this paper, practical considerations of column efficiency, separation speed, thermal stability, and column polarity of capillary columns packed with polybutadiene-coated zirconia were investigated under solvating gas chromatography (SGC) conditions using carbon dioxide as mobile phase. When compared with results obtained from conventional porous octadecyl obtained from conventional porous octadecyl bonded silica (ODS) particles, PBD-zirconia particles produced greater change in mobile phase linear velocity with pressure than conventional ODS particles under the same conditions. The maximum plate number per second (Nt) obtained with a 30 cm PBD-zirconia column was approximately 1.5 times higher than that obtained with an ODS column at 100 °C. Therefore, the PBD-zirconia phase is more suitable for fast separations than conventional ODS particles in SGC. Maximum plate numbers per meter of 76,900 and 63,300 were obtained using a 57 cm×250 μm i.d. fused silica capillary column packed with 3 μm PBD-zirconia at 50 °C and 100 °C, respectively. The PBD-zirconia phase was stable at temperatures up to 320 °C under SGC conditions using carbon dioxide as mobile phase. Polarizable aromatic compounds and low molecular weight ketones and aldehydes were eluted with symmetrical peaks from a 10 cm column packed with 3 μm PBD-zirconia. Zirconia phases with greater inertness are required for the analysis of more polar compounds by SGC.  相似文献   

12.
The simultaneous determination of two binding parameters for metal ions on an immobilized metal affinity chromatography column was performed by frontal chromatography. In this study, the binding parameters of Cu2+ to l ‐glutamic acid were measured, the metal ion‐binding characteristics of the complex ligand were evaluated. The linear correlation coefficients were all greater than 99%, and the relative standard deviations of two binding parameters were 0.58 and 0.059%, respectively. The experiments proved that the frontal chromatography method was accurate, reproducible, and could be used to determine the metal‐binding parameters of the affinity column. The effects of buffer pH, type, and concentration on binding parameters were explored by uniform design experiment. Regression, matching and residual analyses of the models were performed. Meanwhile, the optimum‐binding conditions of Cu2+ on the l ‐glutamic acid‐silica column were obtained. Under these binding conditions, observations and regression values of two parameters were similar, and the observation values were the best. The results demonstrated that high intensity metal affinity column could be effectively prepared by measuring and evaluating binding parameters using frontal chromatography combined with a uniform design experiment. The present work provided a new mode for evaluating and preparing immobilized metal affinity column with good metal‐binding behaviors.  相似文献   

13.
A new sorbent S-benzyldithiocarbazate (SBDTC) modified activated carbon (AC-SBDTC) was prepared and studied for preconcentration for trace mercury(II) prior to inductively coupled plasma atom emission spectrometry (ICP-AES). The experimental conditions were optimised with respect to different experimental parameters using both batch and column procedures in detail. The optimum pH value for the separation of Hg(II) on the new sorbent was 3, while the adsorption equilibrium was achieved in less than 5?min. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 5?mL of 0.25?mol?L?1 of HCl and 2% CS(NH2)2. Common coexisting ions did not interfere with the determination. The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 0.55?mmol?g?1. The detection limit of the present method was found to be 0.09?ng?mL?1, and the relative standard deviation (RSD) was lower than 2.0%. The procedure was validated by analysing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and preconcentration of trace Hg(II) from the natural water samples yielding 80-fold concentration factor.  相似文献   

14.
The retention of analgin, caffeine, phenobarbital, and codeine—components of the medicine Pentalgin N—on a chromatographic column filled with the Nova-Pak CN HP sorbent with modifying nitrile groups as a function of the pH of the mobile phase, the concentrations of the organic modifier acetonitrile and potassium dihydrogen phosphate in the mobile phase was studied. The optimum conditions of the separation of the components were selected.  相似文献   

15.
A comparison of different chromatographic methods is presented: column liquid chromatography (CLC), thin layer chromatography (TLC), and continuous-elution flat-bed chromatography (CEFBC), which is in fact a combination of the first two methods. In CEFBC a sample is applied to a sorbent layer in a steady flow of eluent, and the components are detected directly on the layer, or immediately upon leaving it, during the separation process. It is shown that evaluation of the separation processes in CEFBC is best accomplished in terms of the parameters applicable in CLC. The reproducibility of the analytical results obtained by CEFBC is better than in the case of TLC by a factor of 6 to 10, and approaches that known for CLC.  相似文献   

16.
《Analytical letters》2012,45(1):110-118
The new ionic liquid-modified polymer sorbent was developed by surface chemical modification of the synthesized polymer particles using ionic liquids. The obtained ionic liquid-modified polymer was successfully used as a special sorbent in a solid-phase extraction (SPE) process to isolate caffeine and theophylline from green tea. A comparison of different SPE cartridges using the blank polymer, C18, and ionic liquid-modified polymer revealed that the highest recovery was obtained using ionic liquid-modified polymer sorbent. Quantitative analysis was carried out by using a C18 column (5 µm, 150 × 4.6 mm) as an analytical column. Good linearity was obtained from 5 × 10?4 to 0.5 mg/mL (r2>0.999) for the two analytes with relative standard deviations <4.5%.  相似文献   

17.
Biomass tar mainly consists of stable aromatic compounds such as benzene and polyaromatic hydrocarbons, benzene being the biggest tar component in real biomass gasification gas. For the analysis of individual tar compounds, the solid-phase adsorption method was chosen. According to this method, tar samples are collected on a column with an amino-phase sorbent. With a high benzene concentration in biomass tar, some of the benzene will not be collected on the amino-phase sorbent. To get over this situation, we have installed another column with activated charcoal which is intended for collection of volatile organic compounds, including benzene, after the column with the amino-phase sorbent. The study of maximal adsorption amounts of various compounds on both adsorbents while testing different sampling volumes led to the conclusion that benzene is a limiting compound. The research proved that the use of two sorbents (500 mg + 100 mg) connected in series allows for assessment of tar in synthesis gas with a tar concentration up to 30-40 g m(-3), which corresponds to the requirements of most gasifiers.  相似文献   

18.
The principle of cycle repetition with reversal of two columns is extended to two-cycle circulation chromatography as a version of preparative liquid chromatography. This is regarded as an alternative to closed-loop circulation. A theory of fine separation of binary mixtures is developed taking into account the possibility of programming the length of the sorbent layer and stepwise chromatography. Theoretical analysis and calculations have shown that circulation systems with two cycles and columns filled with sorbent particles ranging from 10 to 35 m are characterized by high resolution and a relatively low pressure drop between the columns.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 9, pp. 1535–538, September, 1993.  相似文献   

19.
金属螯合亲和色谱中的疏水作用   总被引:1,自引:0,他引:1  
李蓉陈国亮  赵文明 《分析化学》2005,33(10):1376-1380
通过考察盐溶盐和盐析盐浓度对蛋白质在IDA裸柱和金属螯合柱上保留行为的影响,详细研究了金属螯合色谱中的疏水作用,疏水作用的发生、形成的条件以及不同条件下对蛋白质保留值的贡献。实验结果表明,在高浓度和低浓度的盐溶盐以及低浓度盐析盐中,蛋白质在金属螯合柱上的保留主要受静电和配位作用控制,而疏水作用对蛋白质的保留影响很小。对弱亲和性的金属螯合柱以静电作用为主,其大小可用参数Q表征;对强亲和性的IDA-Cu(Ⅱ)柱以配位作用为主。仅在高浓度的盐析盐中,金属螯合柱才呈现较强的疏水作用,支配蛋白质保留。实验证明,金属螯合色谱中疏水作用主要来自固定相间隔臂中的疏水碳链和盐析盐对蛋白质的增疏作用,利用这种疏水作用有可能改善金属螯合色谱分离的选择性。  相似文献   

20.
The characteristic kinetic and retention properties of a silica-based cyanopropylsiloxane-bonded sorbent for solid-phase extraction are described. Abraham′s solvation parameter model is used to characterize the contribution of individual intermolecular interactions to retention under liquid chromatographic and sample processing conditions with aqueous methanol mixtures as the mobile phase. The main features governing retention by the sorbent are the solute's size and hydrogen-bond basicity; interactions of a dipole type are not significant when aqueous methanol solutions are employed as the mobile phase. Compared to typical silica-based octadecylsioxane-bonded sorbents the greater difficulty of forming a cavity in the solvated cyanopropylsiloxane-bonded sorbent more than offsets the more favorable dipole-type and solute hydrogenbond base interactions of the cyanopropylsiloxane-bonded sorbent. It is shown that there are no practical circumstances for which a cyanopropylsiloxane-bonded sorbent would be more useful than a typical ODS sorbent for the isolation of organic non-electrolytes from water by solid-phase extraction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号