1.
AOAC Official Method 996.10, Assurance Enzyme Immunoassay (EIA) for Escherichia coli O157:H7 (EHEC), was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by EIA and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) enrichment conditions and the FDA Bacteriological Analytical Manual (BAM) isolation and confirmation techniques. A total of 14 collaborators participated. Raw and cooked ground beef were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. Collaborators tested 378 test portions and controls by both the 8 h EIA and the USDA/FSIS enrichment methods, for a total of 756 test portions. Of the 378 paired test portions, 75 were positive and 212 were negative by both methods. Thirteen test portions were presumptively positive by EIA and could not be confirmed culturally; 30 were negative by EIA, but confirmed positive by culture; and 65 were negative by the culture method, but confirmed positive by the EIA method. There was no statistical difference between results obtained with the Assurance EIA for EHEC 8 h method and the culture method for raw ground beef. The Assurance EIA had a significantly higher recovery for cooked beef.  相似文献   

2.
The Visual Immunoprecipitate Assay (VIP) method for the detection of enterohemorrhagic Escherichia coli O157:H7 (VIP for EHEC) and Assurance Enzyme Immunoassay (EIA) method for the detection of EHEC (EHEC EIA) are AOAC INTERNATIONAL Official Methods 996.09 and 996.10, respectively. A minor modification to the enrichment medium used in both methods has been developed. This modification, the BioControl modified EHEC medium (BioControl mEHEC) provides a more cost-effective procedure with performance equivalent to that of the cultural method for detection of E. coli O157:H7 in beef.  相似文献   

3.
Test portions from 3 environmental surface types, representative of typical surfaces found in a food production facility, were analyzed by the Visual Immunoprecipitate assay (VIP) and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) culture method for Listeria monocytogenes and related Listeria species. In all cases, naturally contaminated environmental test samples were collected from an actual food production facility by sponge or swab. Test samples from concrete surfaces were collected by both swab and sponge; sponge test samples were collected from rubber surfaces, and swabs were used to sample steel surfaces. Test portions from each surface type were simultaneously analyzed by both methods. A total of 27 laboratories, representing government agencies as well as private industry in both the United States and Canada, participated in the study. During this study, a total of 615 test portions and controls was analyzed and confirmed, of which 227 were positive and 378 were negative by both methods. Nine test portions were positive by culture, but negative by the VIP. Five test portions were negative by culture, but positive by the VIP. Four test portions were negative by VIP and by culture, but confirmed positive when VIP enrichment broths were subcultured to selective agars. The data reported here indicate that the VIP method and the USDA/FSIS culture method are statistically equivalent for detection of L. monocytogenes and related Listeria species from environmental surfaces taken by sponges or swabs.  相似文献   

4.
Five different food types were analyzed by the Reveal for E. coli O157:H7 8-Hour Test System (Reveal 8) and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) culture method or the U.S. Department of Agriculture Food Safety Inspection Service (FSIS) culture method for the presence of E. coli O157:H7. A total of 27 laboratories representing academia and private industry in the United States and Canada participated. Food types were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. During this study, 1,110 samples and controls were analyzed by both the Reveal 8 and by BAM or FSIS by each of the collaborators (2,220 samples in total). For each set of samples, 740 were artificially inoculated with E. coli O157:H7, and 370 were uninoculated controls. The Reveal 8 detected 528 presumptive positives of which 487 were confirmed positive by the BAM culture method. In comparison, BAM and FSIS detected 489 of the 740 artificially contaminated samples as positive. In an additional in-house study performed only on chilled and frozen raw ground beef, 240 artificially inoculated samples were analyzed by both the Reveal 8 and by FSIS. The Reveal 8 detected and confirmed 104 samples as positive compared to 79 confirmed positive by FSIS.  相似文献   

5.
Reveal E. coli 2.0 is a new lateral-flow immunodiagnostic test for detection of E. coli O157:H7 and O157:NM in raw beef trim and ground beef. Compared with the original Reveal E. coli O157:H7 assay, the new test utilizes a unique antibody combination resulting in improved test specificity. The device architecture and test procedure have also been modified, and a single enrichment protocol was developed which allows the test to be performed at any point during an enrichment period of 12 to 20 h. Results of inclusivity and exclusivity testing showed that the test is specific for E. coli serotypes O157:H7 and O157:NM, with the exception of two strains of O157:H38 and one strain of O157:H43 which produced positive reactions. In internal and independent laboratory trials comparing the Reveal 2.0 method to the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of E. coli O157:H7 in 65 and 375 g raw beef trim and ground beef samples, there were no statistically significant differences in method performance with the exception of a single internal trial with 375 g ground beef samples in which the Reveal method produced significantly more positive results. There were no unconfirmed positive results by the Reveal assay, for specificity of 100%. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device incubation time or temperature. However, addition of the promoter reagent to the test sample prior to introducing the test device is essential to proper test performance.  相似文献   

6.
A collaborative study was conducted to validate new enrichment methods for the TECRA Listeria Visual Immunoassay (TLVIA). These new methods incorporate a newly formulated medium, TECRA Listeria Enrichrment Broth, which does not contain the highly toxic antifungal agent, cycloheximide. The new procedures will provide an alternative to the enrichment procedures described in AOAC Method 995.22. Three food types (raw ground beef, lettuce, and ice cream) were analyzed in the United States, and 2 food types (cooked turkey and cooked fish fillets) were analyzed in Australasia. Thirty collaborators participated in the study, 16 in Australasia and 14 in the United States. With the exception of one batch of ground beef, comparison of the proportion of positive test portions (p > or = 0.05) showed no significant difference between the TLVIA and the reference method for the 5 foods at 3 inoculation levels. For the one batch of naturally contaminated raw ground beef, the TLVIA gave significantly more confirmed positive results than the reference method.  相似文献   

7.
Test portions from 3 environmental surface types, representative of typical surfaces found in a food production facility, were analyzed by the Assurance Listeria Polyclonal Enzyme Immunoassay (EIA) and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) culture method for Listeria monocytogenes and related Listeria species. In all cases, naturally contaminated environmental test samples were collected from an actual food production facility by sponge or swab. Test samples from concrete surfaces were collected by both swab and sponge; sponge test samples were collected from rubber surfaces, and swabs were used to sample steel surfaces. Test portions from each surface type were simultaneously analyzed by both methods. A total of 23 collaborators, representing government agencies, as well as private industry in both the United States and Canada, participated in the study. During this study, a total of 550 test portions and controls was analyzed and confirmed, of which 207 were positive and 336 were negative by both methods. Six test portions were positive by culture, but negative by the EIA. Three test portions were negative by culture, but positive by the EIA. Two test portions were negative by EIA and by culture, but confirmed positive when EIA enrichment broths were subcultured to selective agars. The data reported here indicate that the Assurance Listeria EIA method and the USDA/FSIS culture method are statistically equivalent for detection of L. monocytogenes and related Listeria species from environmental surfaces taken by sponges or swabs.  相似文献   

8.
A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay. Five food types--brie cheese, vanilla ice cream, frozen green beans, frozen raw tilapia fish, and cooked roast beef--at 3 inoculation levels, were analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study, 1206 test portions were tested, of which 1170 were used in the statistical analysis. There were 433 positive by the VIDAS LIS assay and 396 positive by the standard culture methods. A Chi-square analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting average Chi square analysis, 0.42, indicated that, overall, there are no statistical differences between the VIDAS LIS assay and the standard methods at the 5% level of significance.  相似文献   

9.
The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.  相似文献   

10.
A multilaboratory collaborative study was conducted to compare the Assurance GDS for E. coli 0157:H7 method and the reference culture methods for the detection of E. coli 0157:H7 in orange juice, raw ground beef, and fresh lettuce. A separate companion assay, the Assurance GDS for Shigatoxin Genes method was also evaluated with the same test portions. Fifteen laboratories participated in the study. A Chi square analysis of each of the 3 food types at the high, low, and uninoculated control levels was performed. For all foods, the Assurance GDS for E. coli O157:H7 method and the Assurance GDS for Shigatoxin Genes method were equivalent to or better than the reference methods.  相似文献   

11.
A multilaboratory study was conducted to compare the VIDAS Listeria monocytogenes II (LMO2) immunoassay and the standard cultural methods for the detection of Listeria monocytogenes in foods. Five food types-vanilla ice cream, brie cheese, cooked roast beef, frozen green beans, and frozen tilapia fish-at 3 levels were analyzed by each method. A total of 26 laboratories representing government and industry participated. In this study, 1404 test portions were analyzed of which 1152 were used in the statistical analysis. There were 448 positive by the VIDAS LMO2 assay and 457 positive by the standard culture methods. A chi2 analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting chi2 value, 0.36, indicates that overall, there are no statistical differences between the VIDAS LMO2 assay and the standard methods at the 5% level of significance.  相似文献   

12.
Four different food types along with environmental swabs were analyzed by the Reveal for E. coli O157:H7 test (Reveal) and the Bacteriological Analytical Manual (BAM) culture method for the presence of Escherichia coli O157:H7. Twenty-seven laboratories representing academia and private industry in the United States and Canada participated. Sample types were inoculated with E. coli O157:H7 at 2 different levels. Of the 1,095 samples and controls analyzed and confirmed, 459 were positive and 557 were negative by both methods. No statistical differences (p <0.05) were observed between the Reveal and BAM methods.  相似文献   

13.
The Visual Immunoprecipitate (VIP) for the Detection of E. coli O157:H7 in Foods, AOAC Official Method 996.09, has been modified to use a simplified plastic housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Three foods were analyzed. In total, valid results were obtained from 240 samples and controls. Results showed that the VIP for E. coli O157:H7 is equivalent to the reference culture methods for the detection of E. coli O157:H7.  相似文献   

14.
A rehydratable dry-film plating method for Escherichia coli, the Petrifilm E. coli/Coliform (EC) Count Plate in foods, has been compared with the AOAC INTERNATIONAL most probable number (MPN) method. Eleven laboratories participated in the collaborative study. Three E. coli levels in 8 samples each of frozen raw ground turkey, frozen raw ground beef, and frozen cooked fish were tested in duplicate. Mean log counts for the Petrifilm plate procedure were not significantly different from those for the MPN procedure for cooked fish samples inoculated with low or high inocula levels, for samples of raw turkey inoculated at medium level, and for beef inoculated at low, medium, and high levels. Repeatability and reproducibility variances of the Petrifilm EC Plate method recorded at 24 h were as good as or better than those of the MPN method. The dry rehydratable film method for enumerating confirmed E. coli in poultry, meats, and seafood has been adopted first action by AOAC INTERNATIONAL.  相似文献   

15.
An independent laboratory study of the BAX for Screening/E. coli O157:H7 kit was conducted at the National Food Laboratory, Inc., Dublin, CA, to complete AOAC Performance Tested Method certification. The BAX system kit was compared with the BAM culture method and a modified BAM culture method for detection of E. coli O157:H7 in ground beef. The BAX system kit detected the target organism at levels approximately 10-fold lower than those that gave positive BAM results. This study validated product claims, and Performance Tested Method status was granted.  相似文献   

16.
An interlaboratory study was conducted for the validation of 3 methods for the detection of all verotoxin-producing Escherichia coli (VTEC) in foods. The methods were a multi-analyte 1-step lateral flow immunoassay (LFIA) for detection of E. coli O157 and verotoxin (VT); an enzyme-linked immunosorbent assay targeted against VT1, VT2, and VT2c (VT-ELISA); and a polymerase chain reaction (PCR) method for detection of VT genes (VT-PCR). Aliquots (25 g or 25 mL) of 4 food types (raw minced [ground] beef, unpasteurized milk, unpasteurized apple juice [cider], and salami) were individually inoculated with low numbers (<9 to 375 cells/25 g) of 6 test strains of E. coli (serogroups O26, O103, O111, O145, and O157) with differing VT-producing capabilities. Five replicates for each test strain and 5 uninoculated samples were prepared for each food type. Fourteen participating laboratories analyzed samples using the LFIA, 9 analyzed the samples by ELISA, and 9 by PCR. The LFIA for O157 and VT had a specificity (correct identification of negative samples) of 92 and 94%, respectively, and a sensitivity (correct identification of positive samples) of 94 and 55%, respectively. The VT-ELISA and VT-PCR had a specificity of 98 and 99%, respectively, and a sensitivity of 89 and 72%, respectively.  相似文献   

17.
The Tepnel Bio Kit for the detection of beef in cooked foods was assessed to determine its validity in demonstrating if food being imported into New Zealand contains beef material. The test suffered no interference from the presence of other common nonbovine species meats accepted as food within New Zealand and it detected beef in cooked samples of mixed meats when the proportion of beef in the mixture was >2 or >1%, depending on other meat species present. The documentation supplied with the kit indicates that the specific proteins it measures in cooked beef are stable to 130 degrees C. This was confirmed in the literature when the kit was used to test meat and bone meal cooked to at least 133 degrees C. However, our results showed these proteins to be much less stable when heated to elevated temperatures in moist food under pressure, and samples containing beef ceased to be positive by the immunoassay test after being autoclaved to 121 degrees C. This suggests that the test may not be able to detect even relatively high levels of beef in low-acid canned foods, which are normally retorted under pressure to approximately 121 degrees C.  相似文献   

18.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

19.
A multilaboratory study was conducted to determine the limit of detection (LOD) of Staphylococcal enterotoxins (SET) in 5 foods. Cooked chicken, ham, potato salad, pasteurized liquid whole milk, and canned mushrooms were each spiked with a different enterotoxin (A, B, C1, D, or E), and tested at 0.25 and 0.5 ng/g SET levels to determine the LOD of the assay for those foods in a collaborative study. Unspiked controls were also included. A total of 19 laboratories representing government and industry participated. In this study, 1674 test portions were analyzed, of which 1638 were used in the statistical analysis. Of the 1638 test portions used in the statistical analysis, 1104 were spiked test portions, of which 1073 were positive by the VIDAS Staph enterotoxin II (SET 2) method. The detection rates at the 0.25 ng/mL level were cooked chicken, 98.2%; ham, 99.0%; potato salad, 99.1%; liquid whole milk, 85.2%; and canned mushrooms, 100%. The detection rates at the 0.5 ng/mL level were cooked chicken, 97.4%; ham, 98.1%; potato salad, 100%; liquid whole milk, 99.0%; and canned mushrooms, 100%. The data indicate that the SET 2 method is capable of detecting SET at 0.25 ng/g in cooked chicken, ham, potato salad, and canned mushrooms and at 0.5 ng/g in pasteurized liquid whole milk.  相似文献   

20.
In a multilaboratory study, the effectiveness of an alternative method for rapid screening of Listeria species compared to traditional reference methods was demonstrated in a variety of food products. A collaborative study was conducted to compare the VIDAS Listeria species Xpress (LSX) method and the standard cultural methods for the detection of Listeria species in foods. Six food types were tested: vanilla ice cream, cheddar cheese, raw ground beef, frozen green beans, deli turkey, and cooked shrimp. Each food, inoculated with a different Listeria strain at two levels and uninoculated test portions, was analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study 1134 tests were analyzed in the statistical analysis. There were 490 positives by the VIDAS LSX method using the sample boiling step, 483 positives by the VIDAS LSX method using the Heat and Go system, and 439 positives by the standard culture methods. Overall, the Chi-square result for the VIDAS LSX method with boiling for all foods was 7.25, indicating a significant statistical difference between the VIDAS method and the standard methods at the 5% confidence. For the VIDAS LSX method with the Heat and Go system, the Chi-square result for all foods was 5.37, indicating a significant statistical difference between the VIDAS LSX assay with the Heat and Go system and the standard methods at the 5% level of significance. In both cases, the VIDAS method was more sensitive than the standard methods. The LSX method detects Listeria species in foods with negative or presumptive positive results in a minimum of 30 h compared to at least 5 days for the cultural methods. Based on the results of this collaborative study, it is recommended that the VIDAS LSX method be adopted as an AOAC Official Method for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry.  相似文献   