首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
 A rapid less labour-intensive procedure for complete decomposition of tungsten bearing complex matrices by potassium pyrosulphate and its determination using toluene 3,4-dithiol and thiocyanate is reported. The analytical results of various standard reference materials are presented (Jasperoid GXR-1, Deposit GXR-3, copper mill head GXR-4, tin-tungsten ore IGS-26, Mo-W ore IGS-27, tungsten concentrate SRM-277, scheelite ore SRM-2430, reference tungsten ore TLG-1, CT-1, BH-1 and Mo-W ore MP-2) along with two manganese nodules (GSPN-2 and GSPN-3) recently introduced by the Chinese Academy of Geological Sciences and one Polish soil sample (SRM-2710). For most of the samples the agreement between the observed value and the published data have been found to be extremely good. Derivations have been noted in some samples where published concentrations are indicative values only, indicating that more data are still required to upgrade the status from proposed/unspecified to the certified level. Results of various statistical analyses (intermethod comparison, F-test and regression analysis) reveal that the methods are matrix dependent. Separation of tungsten from molybdenum is straightforward, hence can be used for a quality control programme and in the evaluation of reference materials. Received: 30 December 1996 / Revised: 12 March 1997 / Accepted: 15 March 1997  相似文献   

2.
A microwave digestion method for the determination of marine biological tissues has been developed to allow determination of selenium in small sample sizes (< 0.1 g). The benefits of this technique include maintaining concentrates in extracts without the subsequent over dilution encountered when using larger vessels, increased sample throughput and reduced loss of volatile material. Freeze dried biological material (< 0.1 g) and nitric acid (1 ml) were placed into 7 ml screw top Teflon vessels which are completely sealed on capping. Two 7 ml vials were placed into larger 120 ml vessels fitted with a Teflon spacer and 10 ml of distilled water. The effects of microwave power and time, and sample mass on selenium recovery from three marine standard reference materials (NIST SRM 1566a Oyster Tissue, NRCC DORM-1 Dogfish Muscle and NRCC TORT-1 Lobster Hepatopancreas) were examined. The optimum conditions: 600 W, 2 min; 0 W, 2 min; 450 W, 45 min, allowed quantitative recoveries of selenium from these and three other standard reference materials (NRCC DOLT-1 Dogfish liver, NIST RM-50 Albacore tuna and IAEA MA-A-2 fish flesh). Studies on sample mass showed that the analysis of sample masses from 0.025 to 0.1 g gave selenium concentrations within the certified range. Six species of selenium: selenite, selenate, selenomethionine, selenocysteine, selenocystamine, and trimethyl selenonium were added to oyster, dogfish, and lobster tissues. Recoveries were near quantitative for all species (94–105%) except trimethyl selenonium (90–101%).  相似文献   

3.
Rezić I  Zeiner M  Steffan I 《Talanta》2011,83(3):865-871
A simple, robust and reliable analytical procedure for the determination of 28 selected elements, namely Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, K, Hg, Mg, Mn, Mo, Na, Ni, Pb, Sc, Si, Se, Sn, Sm, Sr, Tl, V, and Zn in textile materials by inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples was optimized and validated in this work. The total amount of elements present in textile samples was determined after microwave digestion of materials in 7 mol/L nitric acid within the optimal working program: 5 min at 150 °C (power 250 W), 15 min 180 °C (300 W) and 20 min at the maximum temperature of 200 °C (350 W). For the quality control reasons, which were ascertained by analysis of the certified cotton trace elements reference material IAEA-V9, the ICP-OES method was optimized through several parameters: by comparing Meinhard and Gemcone Low Flow nebulizers efficiency, ranging nebulizer gas flows from 0.6 to 1.0 L/min, ranging sample flows from 0.8 to 1.2 mL/min, testing RF power from 1200 to 1400 W, detecting data acquisition time (read time) from 0 to 527 s, ranging washing (delay) time from 0 to 408 s, as well as by checking the occurring interferences for the optimal line selection. Validation included determination of linearity, selectivity, accuracy, reproducibility, precision and limits of detection calculated for all 28 selected elements of interest. The developed analytical procedure was successfully applied on textile fibers (cotton, flax and hemp) as well as on standard knitted textile sample materials (cotton and wool).  相似文献   

4.
In general, volatile organic compounds in ambient air are quantified by following a well‐defined standard calibration procedure using a gas‐/liquid‐phase standard. If the liquid standard is analyzed by a thermal desorption, the solvent effect is unavoidable through the alteration of breakthrough properties or retention times. To learn more about the variables of the thermal desorption‐based analysis, the effect of pre‐purge conditions was evaluated for 18 volatile organic compounds with different types of sorbent tube materials by fixing standard volume (1 μL) and flow rate (100 mL/min). The gas phase calibration was also carried out as reference for the non‐solvent effect. A single tube filled with Tenax TA exhibited the least solvent effect with the short pre‐purge (1 min), while being subject to the breakthrough at or above 10 min pre‐purge. For a three‐bed sorbent tube with Carboxen 1000, at least 10 min of pre‐purge was needed for the compounds with a retention time close to methanol (e.g., propanal). Another three‐bed tube with Carbopack X reduced the solvent effect efficiently for a short pre‐purge (2 min) without the breakthrough. As such, the solvent effect can be adjusted by the proper control of the sorbent tube application.  相似文献   

5.
For several years, microwave assisted extraction (MAE) was applied to extract organic compounds such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls, etc., from soils, sediments and standard reference materials. Very few authors applied this methodology for the extraction of PAHs from atmospheric particulate matter. In the present study, MAE of polycyclic aromatic hydrocarbons with hexane/acetone (1:1) from real atmospheric particulate samples was investigated and the effect of microwave energy and irradiation time studied. The yields of extracted compounds obtained by microwave irradiation were compared with those obtained using traditional Soxhlet extraction. MAE was evaluated using spiked real atmospheric particulate samples and two standard reference materials. Analytical determinations of PAHs were carried out by high performance liquid chromatography (HPLC) with ultraviolet and fluorescence detection. The best recoveries were achieved with a microwave energy of 400 W and an irradiation time of 20 min.  相似文献   

6.
Sandroni V  Smith CM  Donovan A 《Talanta》2003,60(4):715-723
A microwave digestion technique was developed to determine the content of nine heavy metals in sediments and soils. The digests were subsequently analysed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The metals determined were Ca, Mg, Fe, Mn, Zn, Cr, Cd, Cu, Pb and V. The digestion was achieved by using an acid mixture of HNO3, HF and distilled H2O. The experimental study was conducted using four standard reference materials (SRMs): sewage sludge (LGC6136), marine sediment (PACS-1), urban particulate matter (NIST 1648) and coal carbonisation site soil (LGC6138). Two different programs were examined to determine which was optimal for the digestion of real environmental samples. The accuracy and precision of the two digestion programs for the analysis of the SRMs were compared. From the results obtained, the microwave program providing a maximum of power of 650 W and a cycle time of 51 min resulted in the best analytical performance. The experimental results obtained were in good agreement with the certified values and demonstrated that the proposed method is precise and accurate.  相似文献   

7.
A microwave digestion procedure for asphaltite ash was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The conditions of the most effective procedure for 0.1 g asphaltite ash samples are 1 ml of HNO3 + 3 ml of HCl + 1 ml of HF + 1 ml of deionized water as acid mixture and 15 min for digestion time. The digestion was accomplished in five stages applying continuously 90% to 20% of the microwave power and 20 to 100 psi of the pressure for 10 min of total time. Concentrations of selected elements, Cr, Co, Fe, Mn, Ni and Zn were measured using inductively coupled plasma-atomic emission spectroscopy. The proposed method of digestion provided precise results with relative standard deviations generally less than 3% for investigated elements. Results for fly ash as standard reference material was in good agreement with certified values.  相似文献   

8.
A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 µL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 24-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 µL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.  相似文献   

9.
The analytical procedure for analysis of methylmercury in fish was developed. It involves microwave-assisted digestion with alkaline solution (tetramethylammonium hydroxide), addition of Cu2+, aqueous-phase derivatization of methylmercury with sodium tetrapropylborate, and subsequent extraction with n-heptane. The methylmercury derivative was desorbed in the splitless injection port of a gas chromatograph and subsequently analyzed by electron impact mass spectrometry. Optimum conditions allowed sample throughout to be controlled by the instrumental analysis time (near 7 min per sample) but not by the sample preparation step. At the power of 15-30, 45, and 60-75 W, sample preparation time is only 3.5, 2.5, and 1.5 min, respectively. The proposed method was finally validated by the analysis of three biological certified reference materials, BCR CRM 464 tuna fish, NRC DORM-2 dogfish muscle, and NRC DOLT-2 dogfish liver. The detection limit of the overall procedure was found to be 40 ng/g of biological tissue for methylmercury. The recovery of methylmercury was 91.2-95.3% for tuna, 89.3-94.7% for marlin, and 91.7-94.8% for shark, respectively. The detected and certified values of methylmercury of three biological certified reference materials were as follows: 5.34 +/- 0.30 microg/g (mean +/- S.D.) and 5.50 +/- 0.17 microg/g for CRM 464 tuna fish, 4.34 +/- 0.24 and 4.47 +/- 0.32 microg/g for NRC DORM-2 dogfish muscle, and 0.652 +/- 0.053 and 0.693 +/- 0.055 microg/g for NRC DOLT-2 dogfish liver, respectively. It indicated that the method was well available to quantify the methylmercury in fish.  相似文献   

10.
Wanekaya AK  Myung S  Sadik OA 《The Analyst》2002,127(9):1272-1276
This work describes a novel technique for the digestion of metals in solid matrices. The technique is called pressure assisted chelating extraction (PACE). In a typical procedure, a solid sample is placed in a stainless steel cell and is mixed with appropriate chelating agents. Using a programmed sequence of temperature, static time, pressure and thermal equilibration available in ASE 200, the metal is removed under moderate temperature (up to 200 degrees C) and pressure (up to 3000 psi). PACE achieves metal recovery that is equivalent to that of wet digestion techniques and also provides for a clean and safe operation by substituting the strong acids commonly used during wet digestion with chelating agents. It uses less solvents and significantly less time (minutes vs. hours) for metal digestion. PACE has been validated using certified standard reference materials (SRMs) including industrial sludge, buffalo river sediments and coal fly ash. The total time required to remove metals was approximately 20 min. Results show that the PACE system provides an ideal platform for efficient, rapid, and safe metal digestion. Good agreement between measured and reference values for Pb, Mn, and Cu were found with recoveries averaging between 80 and 101% and a relative standard deviation of less than 5%. This approach may provide an alternative digestion technique for environmental samples, alloys, biological materials and samples of geological importance. The potential advantage offered lies in non-destruction of the sample, automation and the exclusion of concentrated mineral acids during the digestion procedure.  相似文献   

11.
A microwave procedure for the digestion of the NIST 1634b reference material "residual fuel oil" in closed pressurized vessels was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The influence of sample size, reagent composition and volume, microwave power, and duration of heating on the digestion procedure was studied. Pressure and temperature inside the reaction vessels were monitored to determine the progression of the reaction and to develop optimal conditions. A nine-step heating program requiring 36.5 min with microwave power not exceeding 450 W in the pulsed mode was found suitable for the digestion of approximately 250 mg fuel oil with a mixture of nitric acid (5.0 mL) and hydrogen peroxide (2.0 mL). The reproducibility of microwave power was determined in terms of the relative standard deviations (n = 3) for temperature (2.7%) and pressure (4.9%) data. The vapor pressures obtained with 5.0 mL Milli-Q water (heated) in an 80-mL digestion vessel showed good agreement with literature data. The excess acid in the resulting digests was removed by evaporation and the concentrations of 24 elements (Ag, Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mo, Ni, Pb, Sb, Sn, Sr, Ti, Tl, V, U, and Zn) were determined in the diluted digests by inductively coupled plasma mass spectrometry (ICP-MS). The experimental results were in good agreement with the certified and recommended concentrations for eight elements (Al, As, Co, Cr, Ni, Pb, V, Zn) in solutions obtained after one digestion step. An additional digestion step, consisting of intermediate cooling and venting stages, was required for the accurate determination of Fe. No agreement was reached for Ca and Ba even after two-step digestion. The proposed method of digestion provided precise results with relative standard deviations generally less than 5% for most of the elements determined.  相似文献   

12.
A simple, robust and reliable analytical procedure for the determination of Al, Ca, Fe, K, Li, Mg, Mn, Na, Sr, Ti, and Zn in peat and plant materials by inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed. A microwave heated high pressure autoclave was used to digest powdered sample aliquots (approximately 200 mg) with different acid mixtures including nitric acid (HNO3), tetrafluoroboric acid (HBF4) and hydrogen peroxide (H2O2). The optimized acid mixture for digestion of plant and peat samples consisted of 3 mL HNO3 and 0.1 mL HBF4, in addition to H2O2 which was sub-boiled into the PTFE digestion tubes during heating of the autoclave. Using HNO3 alone, recoveries of Al and Ti were too low by 40 and 160%, respectively, because HNO3 could not fully liberate the analytes of interest from the silicate fraction of the plant and peat matrix. However, for all other elements (such as Mn, Sr, and Zn), the use of HBF4 was less critical. The accuracy of the analytical procedure developed was evaluated with peat and plant reference materials of different origin and composition. The ICP-OES instrument was optimized using solutions of plant reference materials considering RF power, nebulizer pressure, auxiliary gas flow and rinse time. Scandium was used as an online internal standard (IS) as it provided accurate results and showed less than 3% drift in sensitivity over time which was lower compared to other potential IS such as Rh (20%) and In (6%). The combination of most sensitive and less sensitive wavelengths allowed to obtain low detection limits and highest possible dynamic range. The achieved procedure detection limits ranged from 0.05 μg g−1 (Li) to 15 μg g−1 (Ca) and allowed a precise quantification of all elements. Comparative X-ray fluorescence spectrometric measurements of solid peat and plant samples generally agreed well with results obtained by digestion/ICP-OES. To overcome interferences caused by Na, K, and Li, a solution of 10 μg g−1 CsCl2 was successfully used as an ionization buffer. The good agreement between the found and certified concentrations in plant and peat reference materials indicates that the developed analytical procedure is well suited for further studies on the fate of major elements in plant and peat matrices.  相似文献   

13.
An analytical procedure fit for the simultaneous determination of copper (II), chromium(VI), thallium(I), lead(II), tin(II), antimony(III), and zinc(II) by square wave anodic stripping voltammetry (SWASV) in three interdependent environmental matrices involved in foods and food chain as meals, cereal plants and soils is described. The digestion of each matrix was carried out using a concentrated HCl-HNO3-H2SO4 (meals and cereal plants) and HCl-HNO3 (soils) acidic attack mixtures. 0.1 mol/L dibasic ammonium citrate pH 8.5 was employed as the supporting electrolyte. The voltammetric measurements were carried out using, as working electrode, a stationary hanging mercury drop electrode (HMDE) and a platinum electrode and an Ag/AgCl/KClsat electrode as auxiliary and reference electrodes, respectively. The analytical procedure was verified by the analyses of the standard reference materials: Wholemeal BCR-CRM 189, Tomato Leaves NIST-SRM 1573a and Montana Soil Moderately Elevated Traces NIST-SRM 2711. For all the elements in the certified matrix, the precision as repeatability, expressed as relative standard deviation (Sr %) was lower than 5%. The accuracy, expressed as percentage relative error (e %) was of the order of 3-7%, while the detection limits were in the range 0.015-0.103 microg/g. Once set up on the standard reference materials, the analytical procedure was transferred and applied to commercial meal samples, cereal plants and soils samples drawn in sites devoted to agricultural practice. A critical comparison with spectroscopic measurements is also discussed.  相似文献   

14.
Chatterjee A 《Talanta》2000,51(2):303-314
A microwave-assisted digestion procedure was developed in presence of concentrated nitric acid (2.0 ml) and 30% hydrogen peroxide (0.20 ml) using a closed pressurized microwave digestion system for the determination of total anionic and total cationic arsenic compounds reside in oyster tissue. At 450 W for 15 min digestion, 74% of anionic arsenic, and 31% of cationic arsenic (105% total arsenic) were retrieved. At 300 W microwave power, 68% of anionic and 30.5% of cationic arsenic (98.5% total arsenic), and 100 W, 63% of anionic and 31% of cationic arsenic (94% total arsenic) were extracted out. The methanol water mixture (9:1) was cull out, exclusively 31.6% of anionic and 29% of cationic arsenic compounds (60.6% total). The dimethylarsinoylriboside (phosphate-arsenosugar) was the predominant arsenic species, along with arsenobetaine (AB), dimethylarsinic acid (DMA), inorganic arsenic, methylarsonic acid (MA), arsenocholine (AC), trimethylarsineoxide (TMAO) and tetramethylarsonium ion (TMI). Some other arsenic compounds, those were not matched with the retention time of the available standards, were also detected. Arsenosugar was fragile and adequately transmuted to DMA (100%), AB and AC to TMAO (100%) when 450 W microwave power was applied for 15 min. The separation and quantification of arsenic compounds in the microwave digests and extracts, were carried out in anion (PRP-X100) and cation (LC-SCX) exchange columns using ICP-MS as arsenic specific detector. The procedure was also validated by determining the total cationic and total anionic arsenic compounds present in DORM 1.  相似文献   

15.
Closed-vessel microwave digestion of nine standard reference plant materials (NIST, BCR, IAEA) and a laboratory standard of plant material with different Si contents assisted by HNO3 + H2O2 (procedure A), HNO3 + H2O2 + HF + H3BO3 (procedure B) and HNO3 + H2O2 + HBF4 (procedure C) were used to determine the recovery of 36 elements by ICP-MS: Ag, Al, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, In, La, Li, Mn, Mo, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sn, Sr, Th, Tl, U, V, W, Y, Zn. Additions of HF + H3BO3 and HBF4 in procedures B and C exceeded by 10% (B1, C1) and 100% (B2, C2) the equivalent concentrations of Si in the samples determined by ICP-OES. Most recoveries of certified elements (e.g., Al*, Cu, Mo*, Rb*, Sb*, Th) decreased significantly (*p ≤ 0.05) with increasing Si content in plant reference materials digested by procedure A, while the recoveries from procedures B and C decreased insignificantly only for Mo and Sb. Digestions B and C gave significantly higher recoveries of Al, Sb, W and REEs, which were tighter to the reference values of these elements. A similar effect was found for Cu, Fe, Li, Ni, Sn, Th, Tl, V, Zn, Ba, Rb and Sr recoveries in samples with Si contents exceeding 2000 μg g−1. If the Si content in plant samples is less than 10 mg g−1, digestion of 0.5 g of plant samples through 0.05 mL of HF and 0.5 mL of 4% H3BO3 or 0.1 mL of HBF4 is recommended to get satisfactory results for most of the elements. For materials with Si content exceeding 10 mg g−1 the weight of the sample for digestion should be reduced to 0.25 g. However, the operation of potential interferences should be taken into account and eliminated through correction equations and adequate dilution of the samples.  相似文献   

16.
An existing laboratory procedure for selenium analysis using open-vessel wet digestion and liquid chromatographic fluorescence determination was modified for use with microwave digestion. The proposed microwave digestion method eliminated the hazards associated with the use of HClO4 while maintaining excellent recoveries of selenium. A 2-step HNO3/H2O2 digestion procedure was developed. Digested samples were derivatized with 2,3-diaminonaphthalene, and the resultant piazselenol complex was measured fluorometrically using a liquid chromatograph. Measured values were in agreement with 9 different certified reference materials. The detection limit for this method was 0.54 ng Se/g tissue (3 sigma), and the calibration curve remained linear (r2 = 0.9968) up to 2 microg Se/g.  相似文献   

17.
Robache A  Mathé F  Galloo JC  Guillermo R 《The Analyst》2000,125(10):1855-1859
A method was developed for the elemental analysis of size segregated particles ranging from 0.03 to 10 microns. Sampling and analysis problems are discussed in this paper. Particles were collected with a Dekati low-pressure cascade impactor. PTFE filters coated with oleic acid were used as substrate. Particles were microwave digested in closed vessels. The optimum digestion mixture was composed of HNO3 (1 mL), HF (50 microL) and H2O (1 mL). The optimal power setting and digestion time were studied in order to achieve an efficient digestion. A ca. 35 min microwave digestion cycle at a 650 W maximum power allowed complete digestion of the samples. Special emphasis was placed on the pressure in the closed vessels to avoid sample losses. Solution samples were analysed by inductively coupled plasma optical emission spectrometry using an ultrasonic nebuliser for 18 elements (Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, S, Sr, Ti, V, Zn). This procedure was tested with NIST Standard Reference Material 1648 Urban Particulate. Recoveries for certified elements ranged from 95 to 105% except for Al (90%). The influence of cascade impactor materials was investigated with 44 field samples. Strong artefacts due to contamination were shown for analysis at environmental concentrations of Al, Cr, Mn and Ni.  相似文献   

18.
The application of open vessel focused microwave acid digestion is described for the preparation of geological and environmental samples for analysis using inductively coupled plasma-mass spectrometry (ICP-MS). The method is compared to conventional closed-vessel high pressure methods which are limited in the use of HF to break down silicates. Open-vessel acid digestion more conveniently enables the use of HF to remove Si from geological and plant samples as volatile SiF4, as well as evaporation-to-dryness and sequential acid addition during the procedure. Rock reference materials (G-2 granite, MRG-1 gabbros, SY-2 syenite, JA-1 andesite, and JB-2 and SRM-688 basalts) and plant reference materials (BCR and IAEA lichens, peach leaves, apple leaves, Durham wheat flour, and pine needles) were digested with results comparable to conventional hotplate digestion. The microwave digestion method gave poor results for granitic samples containing refractory minerals, however fusion was the preferred method of preparation for these samples. Sample preparation time was reduced from several days, using conventional hotplate digestion method, to one hour per sample using our microwave method.  相似文献   

19.
Determination of Se in biological materials was attempted by microwave-induced plasma mass spectrometry (MIP-MS). (1) Serum samples were available after 10 times dilution with 0.5% nitric acid solution containing 0.1% Triton X-100. When oxygen gas was inserted into the plasma gas (nitrogen) in order to improve the combustion, the sensitivity was reduced to 45%. The detection limit of this method was 0.5 ng/mL. (2) Standard reference materials on commercial base were used to evaluate the accuracy of the Se determination by MIP-MS after microwave digestion. In samples like bovine liver and human hair with Se concentrations of more than 0.7 μg/g, the standard curve method after internal standard (IS) correction was acceptable. This procedure was unsuitable for samples with low Se concentrations such as milk powder (certified value of Se 0.11 μg/g), or plant leaf samples. (3) Instead of IS correction, the peak height of the spectrum was used for calculations from the matrix matched calibration curve. The results of all materials were close to the certified values, even at 25 ng/g. The detection limit of the MIP-MS with microwave digestion and IS correction was 0.05 ng/mL in standard solutions. The detection limit of the peak height method was 0.1 ng/mL and was estimated to be < 20 ng/g in plant materials. Received: 25 September 1998 / Revised: 15 February 1999 / Accepted: 18 February 1999  相似文献   

20.
This article describes the development by response surface methodology (RSM) of a procedure for iron, zinc and manganese determination by flame atomic absorption spectrometry (FAAS) in food samples after digestion employing a focussed microwave system. A Doehlert matrix was used to find optimal conditions for the procedure through response surface study. Three variables (irradiation power and time and composition of oxidant solution—HNO3 + H2O2) were regarded as factors in the optimization study. The working conditions were established as a compromise between optimum values found for each analyte taking into consideration the robustness of the procedure. These values were 12 min, 260 W and 42% (v/v) for irradiation time, irradiation power and percent of H2O2 in solution, respectively. The accuracy of the optimized procedure was evaluated by analysis of certified reference materials and by comparison with a well-established closed vessel microwave dissolution methodology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号